A personal welcome to you from the management and employees of Inter-M
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value,
and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete
satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
his symbol is i ntend ed t o alert t he u ser to the
T
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
presence of uninsulated “dangerous voltage” within
the product’s e nclosur e that may be of suff icient
magnitude to constitute a risk of electric shock to
persons.
AUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
C
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
EFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
R
ATTENTION : RISQUE DE CHOC ELECTRIQUE
NE PAS QUVRIR
Caution: To prevent electric shock do not use this (polarized) plug with
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette
WARNING
To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.
*CLASS 2 WIRING (Adjacent to speaker terminal): The speaker output of this apparatus can exceed 10 Watts and could be a shock injury.
Connection to speakers should be performed by a skilled person.
*Do not install this equipment in a confined space such as a book case or similar unit.
*Warning : To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases,
should not be placed on this apparatus.
*This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
To completely disconnect this apparatus from the AC mains, disconnect the power supply cord plug from the AC receptacle.
*
*
The mains plug of the power supply cord shall remain readily accessible.
CAUTION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
NOTE
*This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
This s ym bol is intende d to a lert the user to t he
presence of important operation and maintenance
(servicing) instructions in the literature accompanying
the appliance.
an exten sion cord, rece ptacl e or other outlet unless the
blades can be fully inserted to prevent blade exposure.
fiche polarisée avec un prolongateur, une prise de courant
on une autre sortie de courant, sauf si les lames peuvent
étre ins ér ées à fond sans e n la isser auc un e pa rtie à
découvert.
Pour decon ne ct er c omplete me nt l ’a ppareil du rese au
d’alimentation. deconnecter le cordon d’alimentation de la
prise murale.
La prise du reseau d’alimentation doit demeurer aisement
accessible.
Although your PA-60A/120A/240A is neither complicated nor difficult to operate, we recommend you take a
few minutes to read this brief manual and familiarize yourself with the important information regarding product
features, setup and operation.
As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.
Installation
Installation
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
S3125A
PA-60A/120A/240A
2
MIXING AMPLIFIER
Overview
Overview
PA-60A/120A/240A are designed to have higher output and a compact size by Class-D design. They are
configured with the models having respectively 60W/120W/240W of output, and can be used as High-Z
(100V/70V) and Low-Z (8/4). PA-A series are designed to allow the stable operation for voice play and
BGM application, and provide the ideal solution to various places like hospitals, restaurants, and schools.
Features
Features
- CLASS-D AMPLIFIERS HAVING 60W/120W/240W OF OUTPUT
- HIGH-Z (100V/70V) AND LOW-Z (8/4)
- MULTIPLE INPUTS (THREE MICS/LINES, TWO LINES, TWO STEREO/LINE INPUTS, TEL IN) AND A FEATURE FOR
CONTROLLING THE VOLUME OF EACH CHANNEL
- EXT IN AND MIX OUT
- DISPLAYING INPUT SIGNAL LED AND OUTPUT LED LEVEL BY CHANNEL
- TONE(BASS/TREBLE) CONTROLLING
- A SWITCH FOR SELECTING 5 SWITCHES (ZONE SELECTION SWITCH)
It is a controller to control the volume of INPUT 1 - 6. Use by controlling to desired volume.
※ Set the controllers of unused input terminals to minimum.
2. INPUT SIGNAL INDICATOR
If there is an input signal to INPUT 1 - 6, due input signal indicator lights up.
3. TONE CONTROLLER
It is a controller to control BASS (100Hz) and TREBLE (10kHz). Users can control to their desired tones.
4. MAIN VOLUME CONTROLLER
It is a controller to control the volumes of whole signals controlled by each input volume controller. When
turning clockwise, the volume increases.
5. CHIME SWITCH
It is a switch to sound 4-note scale of chime. While chiming, a chime indicator on the left side of the switch
lights up.
6. OUTPUT LEVEL INDICATOR
It is an indicator to indicate the level of the signal being printed. Output level is indicated with 3 - 4dB
interval.
7. SIREN ON/OFF SWITCH
It is a switch to turn ON/OFF the siren. When pressing once, the siren turns ON and when pressing once
again, it turns OFF. While the siren is operating, a siren indicator on the right side of the switch lights up.
8. POWER INDICATOR
It is an indicator to display the status of power. When the power switch is ON, the indicator turns on.
PA-60A/120A/240A
4
MIXING AMPLIFIER
9. AUX INPUT TERMINAL (INPUT 6)
It is an AUX input terminal of INPUT 6. Refer to the below picture for the cable needed to the terminal:
10. PROTECTION CIRCUIT INDICATOR
It is an indicator to display the operation status of protection circuit inside the device. When the indicator
turns on, the output is blocked.
11. SPEAKER SELECTION SWITCH
It is a switch to turn ON/OFF the signals printing with five speaker output terminals or to turn ON/OFF
whole output signals with an ALL switch. In the event of speaker output ON, a upper indicator of switch
lights up.
※ Turn off the selection switch for unused speaker.
12. POWER SWITCH
It is a switch to turn on/off the power.
PA-60A/120A/240A
5
MIXING AMPLIFIER
1235764
9
810111213
12345678
9
101112131415
Rear Panel
Rear Panel
1. AC POWER INPUT TERMINAL
It is a terminal to supply power to this device. The power used for this is AC 220-240V, 50/60Hz. Do not
bend by force, pull, twist, heat, or cut the power cord. It may cause a fire or electric shock by damaging the cord.
2. TEL IN VOLUME CONTROLLER
It is a controller to control the volume of TEL IN input. Use by controlling to desired volume.
3. TEL IN PRIORITY CONTROL VOLUME (TEL IN MUTE)
This is a volume that adjusts the volume of INPUT 1, CHIME, and SIREN sound when a signal is input to the
TEL IN. By using TEL IN priority adjustment volume, user can adjust the input signal to INPUT 1, CHIME, and
SIREN. By using priority adjustment volume of INPUT 1, user can adjust the volume of INPUT 2 ~ 6, EXT IN.
4. MIX OUTPUT (MIX OUT) TERMINAL
It is an output terminal to connect when recording the sound printed from this device or using other amps in
parallel. It is a balanced type and pin arrangements are +, -, G.
5. RM-05A CONNECTION TERMINAL
It is a terminal to use by connecting our RM-05A. Pin arrangement of the terminal is as follows:
Pin 1: Remote amplifier input signal hot (+)Pin 9: Remote control ground
Pin 2: Remote amplifier input signal cold (-) Pin 10: DC +24V
Pin 3: Signal groundPin 11: Remote chime
Pin 4: Remote control 1 (SP1)Pin 12: NC
Pin 5: Remote control 2 (SP2)Pin 13: NC
Pin 6: Remote control 3 (SP3)Pin 14: NC
Pin 7: Remote control 4 (SP4)Pin 15: NC
Pin 8: Remote control 5 (SP5)
PA-60A/120A/240A
6
MIXING AMPLIFIER
6. EXTERNAL MUTE SWITCH TERMINAL
It is a terminal to connect the switch when operating the degree that the sound of INPUT 1 – 6, CHIME, EXT
N are decreasing in this device. When the contact closure comes in External MUTE switch terminal, the
I
sound of INPUT 1~6, CHIME, SIREN, EXT IN decreases as much as the volume controlled with the TEL IN
priority control volume and priority control volume (PRIORITY MUTE).
7. EXTERNAL CHIME (EXT CHIME) SWITCH TERMINAL
It is a terminal to connect the switch when operating the 4-note scale chime of this device on the outside.
When the contact closure comes in external chime switch terminal, 4-note scale chime operates.
8. SPEAKER OUTPUT TERMINAL
It is a terminal to use when connecting the speaker. When connecting the speaker, use not to be in overload state.
※ You can control SP1 - 5 terminal with the speaker selection switch on the front side.
※ Be careful not to use 8/4 terminal and SP1 - 5 terminal (high-impedance speaker terminal)
simultaneously.
When connecting the speaker, connect the speaker to use to the speaker terminal on the rear panel in
accordance with the following connection after removing the power cord from the outlet.
8/4+,8/4-SP1~5•COM
High Impedance
Speaker Connection
Low Impedance
Speaker Connection
※ Caution: Be careful not to make total impedance of the speaker terminal to be lower than defined impedance
in any case. Impedance and output voltage are as the following table:
※ Caution: Select the impedance selection switch to use before connecting the speaker.
※ Caution: Be careful not to use 8/4 terminal and SP1 - 5 terminals simultaneously.
PA-60A/120A/240A
7
MIXING AMPLIFIER
XLR
1
2
3
. IMPEDANCE SELECTION SWITCH
9
It is a switch to select the impedance before connecting the speaker. Select the impedance to use among
4/8, 70V, 100V.
10. TEL IN INPUT TERMINAL
It is a terminal to use by connecting with the telephone exchange. You can broadcast directly with the
transmitter of phone.
※ When a signal is input to the TEL IN input terminal, all other input signals will be lower as set by the TEL
IN priority adjustment volume and the priority adjustment volume.
11. EXTERNAL INPUT (EXT IN) TERMINAL
It is an input terminal to connect the output terminal of the external device when extending the input of this
device. It is a balanced type and pin arrangements are +, -, and G.
12. INPUT TERMINAL OF INPUT 1 - 6
It is an input terminal of INPUT 1 - 6. INPUT 1 - 5 is configured with a balanced input circuit and INPUT 6 is
configured with a RCA jack.
1) Input terminal of INPUT 1 - 3
- PHANTOM switch: When turning the switch ON, DC 15 V of phantom power is supplied to use with
condenser mic input.
- INPUT GAIN volume: It is a volume to control GAIN of the input signal.
Do not use XLR jack and Euro Terminal of INPUT 1 - 3 simultaneously as they are connected from the
inside.
2) Input terminal of INPUT 4 - 5
They can be used with LINE input.
3) Input terminal of INPUT 6
Connect it with the audio source device having STEREO output.
* Do not use AUX input terminal of INPUT 6 on the front side and INPUT 6 terminal on the rear side
simultaneously as they are connected from the inside.
※ Refer to the following for the connection of XLR jack, Euro Terminal, and RCA jack.
Turn PHANTOM switch OFF if using the unbalanced cable.
PA-60A/120A/240A
8
MIXING AMPLIFIER
Balanced cable Unbalanced cable
13. PRIORITY CONTROL VOLUME (PRIORITY MUTE)
This is a volume that adjust the volume of INPUT 2~6 and EXT IN when the device is operated by the below
status.
1. When a signal is input to INPUT 1, or CHIME and SIREN is operated
2. When external MUTE switch is operated
3. When a signal is input to TEL IN input terminal
※ The broadcasting of INPUT 1, CHIME, and SIREN signals are printed in priority rather than INPUT 2 - 6,
Operating Temperature
Operating PowerAC 220V, 230V, 240V, 50/60 Hz
Power consumption (1/8W output)40W60W90W
Weight (set)6.25kg/13.78lb7.32kg/16.14lb9.75kg/21.5lb
Dimensions (set)420(W) x 88(H) x 318.7(D)mm/16.54(W) x 3.46(H) x 12.55(D)in
* Design and specification are subject to be changed for the improvement of product quality without pre notice.
BASS(100Hz)
TREMBLE(10KHz)
10dB
-10℃ ~ +40℃
PA-60A/120A/240A
13
MIXING AMPLIFIER
88
420
318.7
4
19
DIMENSIONS
※
14
PA-60A/120A/240A
MIXING AMPLIFIER
Service
Service
Procedures
Take steps to insure the problem is not related to operator error or other products within the system. Information
provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the
problem is related to the product contact your warranty provider as described in the warranty section of this
manual.
Schematic
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Variations and Options
Variations and Options
Variations
Products supplied through legitimate sources are compatible with local AC power requirements.
Options
No optional items are available for this product.
Warranty
Warranty
Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions
of warranty for a given product may be determined first by locating the appropriate country which the product
was purchased in, then by locating the product type.
To obtain specific warranty information and available service locations contact Inter-M directly or the
authorized Inter-M Distributor for your specific country or region.
PA-60A/120A/240A
15
NOTE
Inter-M, Ltd. (Korea) began operations in 1983.
Since then, Inter-M has grown to become one of the largest manufacturers
of professional audio and commercial sound electronics equipment in the world.
Inter-M has gained worldwide recognition for its own branded products,
as well as private label manufacturing of electronics sold under other names (OEM).
The company is no longer just a Korean company, but rather a global company
that is truly international in scope, with factories and offices in Korea and China,
and sales and marketing operations located in Japan, Europe, and the U.S.A.
With more than 850 employees around the globe,
Inter-M is well-poised for further growth and expansion.
Inter-M Americas, INC.
5666 CORPORATE AVE. CYPRESS, CA 90630
TEL : +1-714-828-2200, FAX : +1-714-828-2210
Home Page : http://www.inter-m.net, E-mail : info@inter-m.net
Inter-M Corporation
SEOUL OFFICE : 719, DOBONG-RO, DOBONG-GU, SEOUL, KOREA
TEL : +82-2-2289-8140~8, FAX : +82-2-2289-8149
Home Page : http://www.inter-m.com, E-mail : overseas@inter-m.com
MADE IN KOREA
May 2017 141847