Inter-m IMS-9000D Operating Manual

www.inter-m.com
November 2003 9007000310
IMS-9000D
Delegate Microphone
Operating
Manual
Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers
as well as private label manufacturing of electronics sold under other names (OEM). The company is no longer just a Korean company, but rather a global company
that is truly international in scope, with factories and offices in Korea and China, and sales and marketing operations located in Japan, Europe, and the U.S.A.
With more than 850 employees around the globe, Inter-M is well-poised for further growth and expansion.
INTER-M AMERICAS, INC.
1 EAST BEACON LIGHT LANE CHESTER, PA USA 19013-4409 TEL : (610) 874-8870, FAX : (610) 874-8890 Home Page : http://www.inter-m.net, E-mail : service@inter-m.net
INTER-M Corporation
SEOUL OFFICE:653-5 BANGHAK-DONG, DOBONG-KU, SEOUL, KOREA TEL : 82-2-2289-8140~8, FAX : 82-2-2289-8149 Home Page : http://www.inter-m.com, E-mail : export@inter-m.com
Welcome
Warning................................................................................1
Installation
Environment.........................................................................2
Important Safety Instructions...............................................2
Features.............................................................................4
Front & Rear Panel............................................................5
Connector PIN ...................................................................7
Applications........................................................................8
Application Models for Conference System.......................9
Specifications...................................................................10
Service
Procedures.........................................................................11
Schematic..........................................................................11
Parts List............................................................................11
Warranty ...............................................................................11
1
IMS-9000D(DELEGATE MICROPHONE)
A personal welcome to you from the management and employees of Inter-M
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance.
Caution: These servicing instructions are for use by qualified service
personnel only. To reduce the risk of electric shock, do not any perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette fiche
polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre insérées à fond sans en laisser aucune partie à découvert.
*Do not install this equipment in a confined space such as a book case or similar unit. *The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall
be placed on the apparatus.
*Worded: “WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND
MOISTURE: Unit should not be used near water(e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do not fall and liquids are not spilled into the enclosure through openings.”
3
IMS-9000D(DELEGATE MICROPHONE)
2
IMS-9000D(DELEGATE MICROPHONE)
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such environments usually include high levels of heat, dust, moisture, and vibration.
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance
with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replace­ment of the obsolete outlet.
10. Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the
manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning
storms or when unused for long periods of time.
14. Refer all servicing to qualified service
personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
S3125A
5
IMS-9000D(DELEGATE MICROPHONE)
4
IMS-9000D(DELEGATE MICROPHONE)
LED power indicator on the microphone base.
High quality gooseneck electret cardiode condenser micro­phone.
With the addition of a supplementary power supply, more microphones may be added to the system
On/Off switch allows the user to switch the microphone on or
off (for privacy)
Bright Red (ring) LED on the head of the microphone lights during use, indicating who is speaking.
Electret cardiode condenser gooseneck microphone ensures
excellent sensitivity and intelligibility
ON/OFF
(REAR)
(TOP)
(FRONT)
(SIDE)
1
2
3
4
5
6
7
8
9
–MICROPHONE STAND
–GOOSENECK MICROPHONE UNIT
-MICROPHONE STAND
-GOOSENECK MICROPHONE UNIT
VISUAL MICROPHONE JUNCTION CABLE BY LINK
5P INLINE CONNECTOR 9P D-SUB CONNECTOR
7
IMS-9000D(DELEGATE MICROPHONE)
6
IMS-9000D(DELEGATE MICROPHONE)
11
11. D-SUB CONNECTOR
To connect the controller with included junction cable.
22
22.5P RECEPTACLE
Connector to attach the gooseneck microphone to the base station.
33
33.LED LAMP
Indicates when the mic is in use.
44
44.MIC PUSH SWITCH
To turn on mic unit
55
55.WIND SCREEN
Blocks the ambient noise and protects the microphone unit.
66
66.MICROPHONE
High quality uni-directional condenser microphone.
77
77.BRIGHT RED (RING) LED
Illuminates when the microphone is active.
88
88.FLEXIBLE GOOSENECK MICROPHONE
Microphone can be positioned at the correct level for the operator.
99
99.5P PLUG
Locking plug for attachment of the gooseneck to the base station.
1
2
3
4
5
1 2
3 4 5
+
MIC SIGNAL
LED SIGNAL
COLD [SHIELD]
HOT
1 2
3 4 5
RESET SIGNAL
MIC SIGNAL
COLD
HOT
6 7
8 9
+
SHIELD
DC POWER
12345
6789
9
IMS-9000D(DELEGATE MICROPHONE)
8
IMS-9000D(DELEGATE MICROPHONE)
No. Model No. Description Application
1 IMS-9000 Microphone
Controller
2 IMS-9000C Chairman
Microphone
3 IMS-9000D Delegate
Microphone
4 IMC-04 Junction Cable
IMC-15 Junction Cable IMC-20 Junction Cable IMC-30 Junction Cable
Operates and Controls the system, supplies the chairman and delegate unit’s power and extra functions.
Used as the priority micro­phone the Chairman’s unit has control over the other microphones during use.
A basic microphone unit which can be muted by the Chairmans microphone.
9 pin D-Sub type cable used to connect the system components together, Microphone units are supplied with 4m cable as standard, 15m, 20m, and 30m cables available as an extra option.
250V T3.15AL
AC INPUT
230V/50Hz
www.inter-m.com
MODEL NO. IMS-9000
MICROPHONE CONTROLLER
VOLTAGE: AC 230V, 50Hz
130W
MADE IN KOREA
CAUTION; TO REDUCE THE
RISK OF ELECTRIC SHOCK, DO NOT
REMOVE COVER. NO USER
SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED SERVICE
PERSONNEL.
AVIS; RISQUE DE
CHOC ELECTRIQUE NE PAS OUVRIR.
CAUTION
TO REDUCE THE RISK
OF FIRE REPLACE
ONLY WITH SAME
TYPE FUSE. UTILISER UN FUSIBLE
DE RECHANG DE
MEME TYPE.
TO AC 230V 50Hz
TO MIXER LINE INPUT
OR POWER AMP
CHAIRMAN UNIT
DELEGATE UNIT
DELEGATE UNIT
DELEGATE UNIT
11
IMS-9000D(DELEGATE MICROPHONE)
10
IMS-9000D(DELEGATE MICROPHONE)
ELECTRICAL
Mic Sensitivity .....................................................-47dBV±4dB
Frequency Response........................................100Hz~16kHz
Mic Type...................................Uni-directional condenser mic
S/N..................................................................................60dB
T.H.D (at 1 kHz)..............................................Less than 0.5%
Material......................................................Die-casting & ABS
GENERAL
Power..........................................................................DC 24V
Power Consumption.....................................................100mA
Weight................................................................................1kg
Dimensions......................Stand: 110(W) x 150(H) x 48(D)mm/
....................................................4.3(W)x5.9(H)x 1.8(D)in
...................Mic: 480(H)x10(Unit)mm/ 18.8(H) x 10(Unit)in
* Specifications and design subject to change without notice.
Procedures
Ensure the problem is not related to operator error, or external system devices, Once it is certain that the problem is related to the product contact your warranty provider as described in the warranty section of this manual.
Schematic
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in, then by locating the product type. To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.
Loading...