Inter-M DPA-1200S User Manual

Operation Manual
Digital Power Amplifier
DPA-300S/600S/900S/1200S
DPA-300SO/600SO/900SO/1200SO
* Rack mount products in the Western Hemisphere(North America, South America,
and the Caribbean) do not have handles installed due to customer preference.
DIGITAL POWER AMPLIFIER
Welcome
Welcome
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
This s ym bol is intende d to a lert the user to t he
CAutION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Caution: To prevent electric shock do not use this (polarized) plug with
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do not fall and liquids are not spilled into the enclosure through openings.
*CLASS 2 WIRING (Adjacent to speaker terminal): The speaker output of this apparatus can exceed 10 Watts and could be a shock injury.
Connection to speakers should be performed by a skilled person. *Do not install this equipment in a confined space such as a book case or similar unit. *This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus. *This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the AC Cord.
*
CAutION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
NOtE *This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
presence of uninsulated “dangerous voltage” within the prod uct’s e nclosure that may be of suff icient magnitude to constitute a risk of electric shock to persons.
This s ym bol is intende d to a lert the user to t he presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance.
an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.
fiche polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre ins ér ées à fo nd sans e n laisser auc un e pa rtie à découvert.
DIGITAL POWER AMPLIFIER
Contents
Contents
Unpacking .......................................................................................................................................2
Installation
Environment....................................................................................................................................2
Important Safety Instructions.............................................................................................................2
Features............................................................................................................................................3
Front Panel ......................................................................................................................................4
Rear Panel .......................................................................................................................................5
Speaker Connection.......................................................................................................................7
Applications ....................................................................................................................................8
Block Diagram ................................................................................................................................9
Specifications ................................................................................................................................13
Service
Procedures....................................................................................................................................17
Schematic.....................................................................................................................................17
Parts List .......................................................................................................................................17
Variations and Options ...............................................................................................................17
Warranty .......................................................................................................................................17
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
1
DIGITAL POWER AMPLIFIER
Unpacking
Unpacking
Although your DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO is neither complicated nor difficult to operate, we recommend you take a few minutes to read this brief manual and familiarize yourself with the important information regarding product features, setup and operation.
As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.
Installation
Installation
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such environments usually include high levels of heat, dust, moisture, and vibration.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
S3125A
2
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
DIGITAL POWER AMPLIFIER
Features
Features
- High Performance Class-D Power PA Amplifier
High performance Class-D Power amplifiers produce 300/600/900/1200W rated power each channel.
- Emergency Power Back Up (24VDC) Capability
The unit operates on a DC24 V battery power supply for emergency back up without UPS (DPA-SO models are not included with emergency power back Up (24VDC))
- Rated Output Power Via DC Backup Supply
Output power can be maintained as AC power when 24VDC power supplied.
- Advanced Power Circuitry Design
The combination Class-D type amplification circuitry combined with SMPS creates a high efficiency amplifier offering reduced power consumption and low heat dissipation and weight.
- High Quality Sound Design
The total harmonic distortion is reduced to less than 0.03% THD, with a high signal to noise S /N ratio of over 103dB
- Advanced Protection Circuitry
Advanced protection circuitry guards against overheating, shorted outputs, DC output, overloads and mismatched power
- A Variety of operation Indicators
Signal, -10dB signal level, Clip, Protection and system power (AC, DC, STBY) indicators
- Balanced Input
This connection is used to ensure the lowest noise operation which eliminates the common noise from the cable.
- Remote Power ON/OFF
The remote power allows the amplifier to be turned on or off from a distance or other device via dry contact closure.
- PRIORITY Input
PGM is interrupted and over ridden by the Priority input, when a contact closure is received on the PRI select terminal. This is Ideal for Emergency message broadcasting applications.
Accessories
Ac Power Cord x1 3P Terminal Block x1 2P Terminal Block x1 2P Terminal Block (Ac Remote power) x1 8P Terminal Block x1 Operation Manual x1 Screws for Rack mount Bracket x4
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
3
DIGITAL POWER AMPLIFIER
DPA
DIGITAL POWER AMPLIFIER
1200S
Front Panel
Front Panel
1. SYSTEM POWER INDICATORS
When Power switch is on, AC or DC LED will illuminate depending on input Power source. When Power switch is off, STBY LED will illuminte.
NOTE: During operation of DC, amplifier is keep going to work even if the switch of power is turned off.
Power SW Power LED AC LED STBY LED DC LED
SW ON ON ON OFF OFF
AC/DC
SW OFF OFF OFF ON OFF
SW ON ON ON OFF OFF
AC only
SW OFF OFF OFF ON OFF
SW ON ON OFF OFF ON
DC only
SW OFF ON OFF OFF ON
2. SIGNAL INDICATORS
The LEDS indicate the amplifier’s output signal levels. SIG : Green, -10dB : Green, Clip : Yellow, PROTECT : Red
3. VOLUME CONTROL
Turn the volume controls clockwise to increase gain and counterclockwise to decrease gain.
4. COOLING VENTS
Air flow is front to back. DO NOT block front or rear air vents.
5. POWER SWITCH
4
Push on/off switch. When Power switch is on, BLUE LED will illuminate.
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
Rear Panel
O
UTPUT
VOLTAGE
+
-
G
P
GM INPUT
70V100V
O
UTPUT
+
-
G
1
COM
P
RIORITY
N.C
SW
INPUT
A
C INPUT
P
RIORITY
V
OLUME
MIN MAX
+
-
DC INPUT 21V-27V
MAX 60A
A
C POWER REMOTE
1 2 3 4 5 6
7 8 9
Rear Panel
DIGITAL POWER AMPLIFIER
1. AC MAINS (AC INLET)
It accepts a standard IEC mains cable, provided
2. DC INPUT TERMINAL
Emergency DC back up power (24VDC) terminal. When AC power is cut off, The unit will operate with DC power from spare battery pack. (DPA-SO models are not included with Emergency Power Back Up (24VDC))
3. AC POWER REMOTE
This terminal allows the amplifier to be turned on or off from a distance or other device.
4. COOLING VENTS
Air flow is front to back. DO NOT block front or rear air vents.
5. PRIORITY INPUT AND CONTACT CLOSURE
Each amplifier module has 2 audio inputs. The Primary program input, PGM and Priority input, PRI. The primary regular broadcast program input, PGM is interrupted and over ridden by the Priority input, PRI, when a contact closure is received on the PRI select terminal. This is Ideal for Emergency message broadcasting applications.
6. PRI VOLUME CONTROL
It controls the mute level of all other input signal when the PRI IN signal is present.
7. OUTPUT TERMINAL
Speaker Output Terminal with Euro Block.
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
5
DIGITAL POWER AMPLIFIER
8. OUTPUT VOLTAGE SELECTOR
his two-position switch is used to select a output voltage (100V or 70V).
T
9. PGM INPUT CONNECTOR
Balanced 3-pin terminal block connector accept the source input.
6
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
DIGITAL POWER AMPLIFIER
10W 10W 10W 10W
....
Speaker Connection
Speaker Connection
Before connecting speakers to the unit, be sure to disconnect the AC power cable. Make certain that the total impedance is not less than the rated impedance indicated.
Caution: 1. Make sure that the total impedance does not equal or less than the rated impedance.
Speaker Output Speaker Impedance
100V / 33.3
300W
600W
900W
1200W
2. Do not connects a speaker has lower impedance than rated impedance, It may cause the problem to unit.
3. Do not put the speaker cable close to input signal cable.
70V / 16.3
49V / 8
100V / 16.6
70V / 8.2
69.3V / 8
100V / 11.1
70V / 5.4
84.9V / 8
100V / 8.3
70V / 4.1
98V / 8
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
7
DIGITAL POWER AMPLIFIER
OUTPUT
VOLTAGE
+
-
G
P
GM INPUT
70V100V
OUTPUT
+
-
G
1
COM
P
RIORITY
N.C
SW
INPUT
AC INPUT
PRIORITY VOLUME
M
IN MAX
+
-
DC INPUT 21V-27V
MAX 60A
AC POWER REMOTE
Applications
Applications
8
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
Block Diagram
Block Diagram
DPA-300S/600S
DIGITAL POWER AMPLIFIER
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
9
DIGITAL POWER AMPLIFIER
DPA-900S/1200S
10
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
PWM
PGM+
PGM-
GND
PGM
PGM VOLUME
PRI+
PRI-
GND
PRI
COM
1
SPEAKER OUTPUT
0dB
0dB
PRI VOLUME
+12dB
+12dB
P/C
LPF 35kHz GAIN= 0/-3dB
100/70 Vrms
PROTECTION
OCP, OTP
CLIP(RED)
SIG(GRN)
-10dB(GRN)
PFC
-VA
+VA
-HV
+HV
ST-BY
MAIN
RECTIFIER
AC
SMPS
100 / 70V SWITCH
PGM/PRI TOGGLE
2nd ORDER LPF
FAN
FAN CONTROL
FAN START 65
ŭ
PROTECT MORE THAN 85ŭ
TEMPERATURE DETECTION
+HV
-HV
DIGITAL POWER AMPLIFIER
DPA-300SO/600SO
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
11
DIGITAL POWER AMPLIFIER
100 / 70V SWITCH
PGM+
PGM-
GND
PGM
PGM VOLUME
PRI+
PRI-
GND
PRI
COM
1
-10dB(GRN)
SIG(GRN)
4th ORDER LPF
SPEAKER RELAY
PROTECTION
SPEAKER OUTPUT
0dB
0dB
+12dB
+12dB
P/C
PGM/PRI TOGGLE
LPF 25kHz GAIN= 0/-3dB
OCP, OTP
100/70 Vrms
CLIP(RED)
PRI VOLUME
-VA
+VA
-HV
+HV
AC
ST-BY
MAIN
RECTIFIER
SMPS
HPF 60Hz
PWM
FAN
FAN CONTROL
FAN START 65
ŭ
PROTECT MORE THAN 85ŭ
TEMPERATURE DETECTION
+HV
-HV
DPA-900SO/1200SO
12
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
DIGITAL POWER AMPLIFIER
Specifications
Specifications
DPA-300S DPA-600S DPA-900S DPA-1200S
Rated Output Power (T.H.D 0.1%, AES17)
Peak Power 480W 680W 1050W 1260W
300W 600W 900W 1200W
Output Level/Impedance
Input Sensitivity 1V/10k T.H.D Rated Power Less than 0.1%
(AES17)
S/N (20kHz LPF) More than 103dB Frequency Response (1W, ±3dB) 50Hz ~ 20kHz 60Hz ~ 20kHz Operating Temperature -10°C ~ +40°C Operating Power 120VAC, 60Hz, 220-240VAC, 50/60Hz
Power Consumption (1/8 Power) 130W 250W Weight (SET) 6.5kg/14.3lb 6.6kg/14.6lb 7.7kg/17lb 7.7kg/17lb Dimensions (SET) 482(W)x88(H)x397(D)mm 482(W)x88(H)x450(D)mm
* Design and specification are subject to be changed for the improvement of product quality without pre notice.
1/3 Power Less than 0.03%
100V/33.3 100V/16.6 100V/11.1 100V/8.3
70V/16.3 70V/8.2 70V/5.4 70V/4.1
49V/8 69.3V/8 84.9V/8 98V/8
DC 24V
19(W)x3.5(H)x15.6(D)in 19(W)x3.5(H)x17.7(D)in
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
13
DIGITAL POWER AMPLIFIER
PA-300SO DPA-600SO DPA-900SO DPA-1200SO
D
Rated Output Power (T.H.D 0.1%, AES17)
Peak Power 480W 680W 1050W 1260W
Output Level/Impedance
Input Sensitivity 1V/10k T.H.D Rated Power Less than 0.1%
(AES17)
S/N (20kHz LPF) More than 103dB Frequency Response (1W, ±3dB) 50Hz ~ 20kHz 60Hz ~ 20kHz Operating Temperature -10°C ~ +40°C Operating Power 120VAC, 60Hz, 220-240VAC, 50/60Hz Power Consumption (1/8 Power) 130W 250W Weight (SET) 6.1kg/13.5lb 6.1kg/13.5lb 6.3kg/13.7lb 6.3kg/13.7lb Dimensions (SET) 482(W)x88(H)x397(D)mm / 19(W)x3.5(H)x15.6(D)in
* Design and specification are subject to be changed for the improvement of product quality without pre notice.
1/3 Power Less than 0.03%
300W 600W 900W 1200W
100V/33.3 100V/16.6 100V/11.1 100V/8.3
70V/16.3 70V/8.2 70V/5.4 70V/4.1
49V/8 69.3V/8 84.9V/8 98V/8
14
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
DIMENSIONS
PA-300S/600S, DPA-300SO/600SO/900SO/1200SO
D
DIGITAL POWER AMPLIFIER
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
15
DIGITAL POWER AMPLIFIER
440
420
482
88
PA-900S/1200S
D
16
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
DIGITAL POWER AMPLIFIER
Service
Service
Procedures
Take steps to insure the problem is not related to operator error or other products within the system. Information provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the problem is related to the product contact your warranty provider as described in the warranty section of this manual.
Schematic
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Variations and Options
Variations and Options
Variations
Products supplied through legitimate sources are compatible with local AC power requirements.
Options
No optional items are available for this product.
Warranty
Warranty
Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in, then by locating the product type.
To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.
DPA-300S/600S/900S/1200S, DPA-300SO/600SO/900SO/1200SO
17
Inter-M, Ltd. (Korea) began operations in 1983.
Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world.
Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).
The company is no longer just a Korean company, but rather a global company that is truly international in scope, with factories and offices in Korea and China, and sales and marketing operations located in Japan, Europe, and the U.S.A.
With more than 850 employees around the globe, Inter-M is well-poised for further growth and expansion.
Inter-M Americas, INC.
13875 ARTESIA BLVD. CERRITOS, CA 90703 USA TEL : +1-562-921-0313, FAX : +1-562-921-0370 Home Page : http://www.inter-m.net, E-mail : info@inter-m.net
Inter-M Corporation
SEOUL OFFICE:653-5 BANGHAK-DONG, DOBONG-GU, SEOUL, KOREA TEL : +82-2-2289-8140~8, FAX : +82-2-2289-8149 Home Page : http://www.inter-m.com, E-mail : overseas@inter-m.com
MADE IN KOREA
August 2013 133376
Loading...