UltraSync LTE Cellular Module Installation Sheet
Product summary
This module adds LTE cellular capability to the UltraSync SelfContained Hub to allow reporting of system events and
enhanced interactivity.
Note: This module is designed for use only with the ZW-6400
Self-Contained Hub.
Figure 1: LTE cellular module
Installing the module
To install the module:
1. Remove the cover on the back of the hub to expose the
cellular module bay.
2. Locate the 10-pin lead inside the hub and connect the LTE
Cellular Module. Take care not to crimp any wires during
installation.
PLEASE READ THE ULTRASYNC SELF-CONTAINED HUB REFERENCE GUIDE BEFORE
USING THIS PRODUCT WHICH INCLUDES IMPORTANT SAFETY AND LEGAL
INFORMATION INCLUDING WARNINGS, WARRANTY DISCLAIMERS, AND LIMITATIONS
OF LIABILITY, AND COMPLETE INSTRUCTIONS. THE REFERENCE GUIDE IS AVAILABLE
AT: http://www.interlogix.com/intrusion/product/ultrasync-selfcontained-hub
S'IL VOUS PLAÎT LIRE LE GUIDE DE REFERENCE POUR LE HUB UltraSync AVANT
D'UTILISER CE PRODUIT QUI COMPREND LA SÉCURITÉ IMPORTANT ET JURIDIQUES
INFORMATIONS, Y COMPRIS LES AVERTISSEMENTS, GARANTIE EXCLUSIONS, ET
LIMITATIONS DE RESPONSABILITÉ ET INSTRUCTIONS COMPLETES. LE GUIDE DE
RÉFÉRENCE EST DISPONIBLE AU: http://www.interlogix.com/intrusion/product/ultrasyncselfcontained-hub
Figure 2: LTE cellular module
3. The LTE Cellular module includes a built in door that
allows for the antenna(s) to exit the back of the hub.
4. Position the plastic door attached to the cellular module so
the top hooks on to the back of the hub.
5. Press down to secure the bottom of the door. The door
should click once in place.
Installing the antenna(s)
Note: The LTE Antenna is a two-in-one antenna designed to
optimize performance and simplify installation.
To install the antenna(s):
1. Connect the two antenna lead wires to the connectors
located on the cellular module plastic door. Make sure to
firmly press the lead wires into the connectors for a secure
fit.
1 / 2 P/N 466-5414 • REV B • ISS 071217
Figure 3: Installing antenna(s)
2. For applications where the hub is permanently mounted
on a wall, create a hole to allow the antenna to drop down
the wall.
3. For applications where the hub is mounted on a desktop
stand, secure the antenna in a place that cannot be easily
moved by using the included adhesive strip.
Note: Be sure to keep hub and cellular antennas away from
electrical devices such as appliances, routers, cables boxes,
as well as mirrors to optimize signal strength.
Commissioning the cellular module
To commission the module:
1. Once the cellular module is installed in the hub, it will
automatically start to try and find a cellular network.
2. When provisioning the system on the UltraSync Portal,
remember to select a Service Grade that includes Cellular.
Specifications
Voltage 5VDC (provided by panel)
Current 40 mA min / 750mA max at 9 V
External connector Two MMCX
Dimensions (W × H ×
D)
Storage temperature -34° to 60°C (-30° to 120°F)
Weight 190 g
Operating environment
Temperature
Relative humidity
97 x 31.5 x 20mm
0° to 49°C (32° to 120°F)
maximum 90% noncondensing
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This class B digital apparatus complies with Canadian ICES-3B.
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.
Caution: Any changes or modifications not expressly approved by the
party responsible for compliance to this equipment would void the
user’s authority to operate this device.
This Device complies with FCC & ISED radiation exposure limits.
This device complies with Industry Canada’s licence-exempt RSSs.
Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes :
1) l’appareil ne doit pas produire de brouillage;
2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Contact information
For contact information, go to www.utcfireandsecurity.com or
www.interlogix.com
Customer support (US)
For customer support, contact
Interlogix Technical Support
Tel +1 855 286 8889 (Option 2)
techsupport@interlogix.com
www.interlogix.com
Copyright © 2017 UTC Fire & Security. All rights reserved.
Regulatory information
Manufacturer Placed on the market by:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092,
USA.
US/C compliance FCCID: N7NHL7588
IC: 2417C-HL7588
2 / 2 P/N 466-5414 • REV B • ISS 071217