Interlogix TVN-2108S-2T Quick Start Guide

Page 1
TruVision NVR 21(S/P) Quick Start Guide
P/N
1072630F-EN REV 1.0 • ISS 09JAN15
Page 2
Copyright
Trademarks and
information
patents
Contact
© 2015 United Technologies Corporation. Interlogix is part of UTC Building & Industrial Systems, a unit of United
Technologies Corporation. All rights reserved.
Trade names used in this document may be trademarks or registered trademarks
of the manufacturers or vendors of the respective products.
www.interlogix.com or www.utcfssecurityproducts.eu
Page 3
Figure 1: Back panel connections
TVN 21(P)
TVN 21S
1. Connect to one CCTV moni tors (BNC-type connectors).
2. Connect one audio input to RCA connectors.
3. Connect to a RS-232 device.
4. Connect to a network.
5. Connect to an optional eSATA device such as SATA HDD, CD/DVD-RM.
6. Connect to a power cord.
7. Connect to speakers for audio output.
8. Connect to a VGA monitor.
TVN 21(S/P) Quick Start Guide 3 : EN
9. Connect to a HDTV. The HDMI connection supports both digital audio and video.
10. Universal Serial Bus (USB). Connect to an
additional device such as a USB mouse, CD/DVD burner or USB HDD.
11. Not used.
12. Not used.
13. Connect to a keyboard (KTD-405 shown)
14. Connect up to 16 alarm inputs.
15. Connect up to four alarm relay outputs.
16. Connect to ground.
17. 8/16 PoE ports
Page 4
Figure
For detailed information on all the button functions, please refer to the user manual.
1
2.
USB Interfaces
3
4
5.
Direction
Enter button
6.
PTZ buttons
2: Front panel controls
Name Description
. Channel buttons
. Status LEDs
. Archive button
Switch between different cameras in live, PTZ control or playback modes. Enter numerals 0 to 9 when using the virtual keyboard.
Universal Serial Bus (USB) ports for additional devices such as a USB mouse, CD/DVD burner, and USB Hard Disk Drive (HDD).
Power: A flashing green light indicates the recorder is working correctly. Red indicates a fault.
Alarm: A steady red light indicates that there is a sensor Alarm In or another alarm such as motion or tampering. A steady green light means there is no alarm.
Tx/Rx: Flashing green indicates a normal network connection. No light indicates that the recorder is not connected to any network.
HDD: HDD indicator blinks red when data is being read from or written to the HDD. A steady red light indicates an HDD exception or error.
Ready: A steady green light indicates the device is functioning properly. Archive: Blinking green indicates archiving is in progress.
Press once to enter quick archive mode. Press twice to start archiving. Indicator blinks green when data is being written to backup device.
The DIRECTION buttons are used to navigate between different fields and items in menus.
In the Playback mode, the left and right buttons are used to speed up and slow down recorded video. The up and down buttons are used to jump recorded video forwards or backwards by 30 s.
In Pause mode, the left and right buttons are used to jump recorded video forwards or backwards by one frame. The up and down buttons are used to jump recorded video forwards or backwards by one second.
In Live View mode, these buttons can be used to cycle through channels. In PTZ Control mode, it can control the movement of the PTZ camera.
The ENTER button is used to confirm selection in any of the menu modes. In Playback mode, press the button to pause the video. In single-frame Pla yback mode, pressing the button will advance the video
by a single frame.
Zoom: In live view, playback, and PTZ control modes mode, use + and – to zoom in and out. Also used to navigate within menus. See the user manual for more information.
Preset: In PTZ control mode, press Preset and a numeric button to call up a preprogrammed preset position.
EN : 4 TVN 21(S/P) Quick Start Guide
Page 5
Tour: In PTZ control mode, press Tour and a numeric button to call up
7.
IR receiver
8.
Playback buttons
earliest video file of the current camera;
mode. In playback mode, stop playing
9.
Menu and Search
10.
Front panel lock
11.
Display buttons
Package contents
The TruVision NVR 21(S/P) (model TVN 21 (S/P) is shipped with the following items:
• IR (infrared) remote control
Two AAA batteries for the remote
• AC power cords (US, Europe, UK)
• USB mouse
NVR
• CD with software and manuals
TruVision NVR 21(S/P) Quick Start
TruVision NVR 21(S/P) User Manual
TruVision Recorder Operator Guide (on
Name Description
preprogrammed shadow tours.
Receiver for IR remote control.
In video playback mode, playback a camera in reverse direction; In picture playback mode, view pictures in reverse direction.
for all cameras in the selected display
the video.
(upper left video tile if in multiview mode); In playback mode, play back a camera in the forward direction; In search mode, play back a selected video or view a snapshot; In PTZ mode, do an auto tour. See the user manual for more information.
Instantly playback the currently selected file. Default time is 1 minute. Live: Switch to live view mode. Hold for five seconds to lock or unlock the
front panel. Replay: In playback mode, start play back at the beginning of the file in the
current display mode.
buttons
Menu: Enter/exit the main menu. Search: In live view mode, enter the advanced search menu.
You can lock or unlock the front panel with a key.
Display: Toggle through the various multiviews: full, quad, 1+5, 1+7, 9, and
16.
Seq: Start/stop sequencing cameras on the current monitor. A: In live view mode, select the main monitor. B: In live view mode, select the event monitor. F1: In playback mode, click to start and stop video clipping. F2: In live view, all-day playback and playback modes press to display/hide
the time or control bar. In PTZ mode, stop all ongoing operations.
control
Guide
(on CD)
CD)
Reverse: In live view, play the
Pause: In live view mode, freeze the last image of of the live display
Play: In live view mode, play all-day playback of the current camera
Installation environment
Refer to the user manual for detailed information, but observe these important requirements:
Place the unit in a secure location.
Ensure that the unit is in a well-
ventilated area.
• Do not expose the unit to rain or moisture.
Quick install
Recommended steps for setting up the
recorder:
TVN 21(S/P) Quick Start Guide 5 : EN
Page 6
1. Connect all the devices required to the
back panel of the
recorder. See Figure 1
on page 3.
Basic connections:
Connect monitor A to the BNC, VGA or HDMI output. Connect the mouse to the USB port in the front panel.
Optional connections:
All the other connections shown are optional and depend upon installation requirements.
2. Connect the power cord to the unit and turn on the power.
3. Set up the unit with the required settings using the setup wizard.
First-time use
The recorder has an express installation wizard that lets you easily configure basic
recorder settings when first used. It
configures all cameras simultaneously. The configuration can then be customized as
required.
By default, the setup wizard will start once
the
recorder has loaded. The wizard walks
you through some of the more important settings of your
recorder. Select the
preferred language for the system and then enter the administrator password. The default admin password is 1234. It is strongly recommended that this password is
changed.
The wizard will then guide you through the menus to set the time and date, network configuration, HDD management, and recording configuration.
When all the required changes have been
entered, click Finish to exit the wizard. The
recorder is now ready to use. Recording
starts automatically.
Operating the TVN 21
There are several ways to control the unit:
Front panel
• IR remote control
Mouse
• Web browser
Front panel
The buttons on the front panel control most functions. See Figure 2 on page 4 for the locations of the controls. Refer to the user manual for a detailed description of the button functions.
IR remote control
The IR remote control buttons are similar to those on the front panel. Place the two AAA batteries in the remote control.
To connect the remote control to the
recorder, press the Device button, enter the
device address, and press Enter.
To connect the remote control to the recorder:
1. Press Menu on the front panel or right­click the mouse and select Menu. The main menu screen appears.
2. Select Display Mode Settings >
Monitor.
3. Check and remember the recorder device address value. The default value is 255. The device address is valid for all IR controls.
4. On the remote control, press the
Device button.
5. Enter the device address value. It must be the same as that on the TVN 21.
6. Press ENTER on the remote or front panel.
USB mouse
The USB mouse provided with the recorder operates all the functions of the
recorder,
unlike the front panel, which has limited functionality. The mouse lets you navigate and make changes to settings in the user interface.
Connect the mouse to the
recorder by
plugging the mouse USB connector into the USB port on the front panel. The mouse is immediately operational and the pointer
should appear.
EN : 6 TVN 21(S/P) Quick Start Guide
Page 7
Web browser control
1.
2.
3.
4.
5.
6.
7.
selected camera. The current
The TVN 21 Web browser lets you view, record, and play back videos as well as manage all aspects of the recorder from any PC with Internet access. The browser’s easy-to-use controls give you quick access
to all
recorder functions. See Figure 3 below.
of the mouse on the camera image. The shortcut pop-up toolbar appears. See Figure 4 below for a description of the functions available.
Figure 4: The mouse menu for the main monitor
To access the unit, open a web browser and enter the IP address assigned to the
recorder as a Web address. In the login
screen, enter the default user ID and
password:
• User ID: admin
Password: 1234
The default values for recorder network
settings are:
DHCP: Disabled by default.
• IP address - 192.168.1.82
• Subnet mask - 255.255.255.0
• Gateway address - 192.168.1.1
Ports:
When using the browser:
RTSP port: 554
HTTP port: 80
When using TruNav:
RTSP port: 554
Server/Client software port : 8000
Figure 3: Web browser interface
Live view mode
Live mode is the normal operating mode of the unit where you watch live pictures from the cameras.
Regularly used functions in live view can be quickly accessed by clicking the right-button
The list of commands available depends on which monitor is active; main or spot (monitor B). See Table 1 below.
Table 1: Mouse menu for monitor A (main monitor)
Name Description
Menu Enter the Main menu.
This option is not available from monitor B.
Single
camera
Multi camera Switch between the different
Previous
screen
Next screen Displays the next camera.
Start
sequence
All-day
playback
Switch to a full-screen view
for the selected camera from
the dropdown list.
multiview options from the
dropdown list.
Displays the previous camera.
Turn on sequence mode. The screen automatically sequences between cameras.
Go to Menu > Displa y Mode Settings > Layout > Dwell Time to set up.
Playback the recorded video of the selected day from the
TVN 21(S/P) Quick Start Guide 7 : EN
Page 8
Name Description
day is selected by default.
8.
9.
10.
ct Standard, Bright, Soft,
1
Power supply
Power cons (without HDD)
Operating temperature Relative humidity
Dimensions (W x
Weight
Monitor B Switch between monitors A
Advanced
search
Output mode Sele
1. Close
timebar
(main) and B (spot).
Enter the advanced video
search menu.
or Vivid mode to display.
Open/close the time bar.
Configures standard network
settings.
Configures alarm settings.
Configures PTZ settings.
Configures user settings.
Configures system settings.
Configuring the TVN 21
The recorder has an icon-driven menu structure that allows you to configure the unit’s parameters. Each command icon displays a screen that lets you edit a group of settings. Most menus are available only to system administrators.
Refer to the detailed information on configuring the unit.
To access the main menu from live view:
Press the Menu button on the remote
Right-click the mouse and select Menu
The main menu screen appears. Move the mouse over a command icon in the menu toolbar and click to select it.
Description of the command icons in the menu toolbar:
recorder user manual for
control or front panel
- Or -
from the pop-up menu.
Configures display settings.
Configures camera settings.
Provides reference information to the various toolbars and menus within the interface.
Provides access to logout, reboot and shutdown options.
Specifications
100 to 240 VAC,
umption
D x H)
≤ 8 kg (≤ 17.6 lb.)
6.3 A, 50 to 60 Hz
<= 45 W
-10 to +55 ºC (50 to 131 °F)
10 to 90%
445 × 470 × 90 mm (17.5 × 18.5 × 3.5 in.)
(without HDD)
Configures recording settings.
EN : 8 TVN 21(S/P) Quick Start Guide
Loading...