1: Back panel connections (Example: TVN 1108S/TVN 1108 shown)
1108S
1108 (EMEA onl y)
1. Connect a microphone for bi-directional audio
(not recorded).
2. Connect up to four alarm inputs
3. Connect one alarm relay output.
4. Connect to a network.
5. Power switch (on/off).
6. Embedded PoE ports to connect IP cameras
(depending on model).
Default IP address - 192.168.1.82
P/N 1073396-EN • REV B • ISS 24MAY18
8. Connect to a VGA monitor.
9. Connect to an HDTV. The HDMI connection supports both digital audio and video.
10. Connect to an optional USB 2.0 device such as a mouse, CD/DVD burner or HDD.
11. Connect to ground.
12. Connect a power cord to the recorder (included).
13. Connect to the 12 VDC PSU (included).
Download the latest recorder firmware and TruVision
Navigator software from www.interlogix.com or
www.firesecurityproducts.com
Figure
2: Front panel controls (4-channel model shown)
For detailed information on all the button
1
2
3
4
5
6
cameras
Name Description
.Channel buttonsSwitch between different cameras in live, PTZ control or playback modes.
.Display buttons
.
Menu and
Search buttons
.IR receiverReceiver for IR remote.
.Status LEDs
.
Playback
buttons
functions, please refer to the user manual.
Display: In multiview mode, toggle through the various multiviews (full, quad,
1+5, 1+7, 9 and 16).
In HDD information mode and user management mode delete a selected item. In
PTZ mode, delete a selected key point. In Log Search mode, display the details
of a log file in Log Search result.
Seq: In Live View mode, start/stop sequencing cameras on the current monitor.
Menu: Enter/exit the main menu.
Search: In live view, enter the advanced search menu.
To connect the remote control to the recorder, press the Device button, enter the
device address, and press Enter. See “IR remote control” on page 5 for more
information.
Power: A steady green light indicates the recorder is working correctly. Red
indicates a fault.
Event Alarm: A flashing red light indicates that there is a sensor Alarm In or
another alarm such as motion or tampering. No light indicates that there is no
alarm.
HDD: HDD indicator blinks red when data is being read from or written to the
HDD. A steady red light indicates an HDD exception or error.
Tx/Rx: Steady green indicates a normal network connection. No light indicates
that it is not connected to a network.
Technical Alarm: A steady red light indicates that there is a technical alarm from
the recorder. No light indicates that there is no alarm.
Reverse: In live view mode, use to play back the earliest video. In playback
mode, playback a camera in the reverse direction.
Pause: In live view, freeze the last image of the live display for all active
displayed. In playback mode, stop playback.
2 TVN 11 Quick Start Guide
Name Description
: In playback mode, start playing the current file. Starts at the beginning of
7
8
9
10
Figure
1. Pause: Freeze live image of the selected
6. PTZ Control: Enter PTZ control mode.
12. Close: Close the toolbar.
.PTZ buttons
.Direction
Enter button
.Archive button
.USB Interface
Play: In live view mode, play all day playback of the current camera (upper-left
video tile if in multiview mode). In playback mode, play back a camera in the
forward direction. In search mode, play back a selected video or view a
snapshot. In PTZ mode, do an auto tour.
Live: Switch to live view mode.
Replay
the file.
Zoom +/-: In live view mode, playback mode, and PTZ control mode use this
button to zoom in and out. Also use them to navigate within menus.
Preset: In PTZ Control mode, press Preset and a numeric button to call the
specified preset.
Also use to edit holiday mode, video search mode, HDD selection mode, user
management mode, bookmark management, and bookmark search.
Tour: In PTZ Control mode, press Tour and a numeric button to call the specified
shadow tour.
Also use to scroll between calendar months and to navigate in a text field.
The DIRECTION buttons are used to navigate between different fields and items
in menus.
The ENTER button is used to confirm selection in any of the menu modes.
Press once to enter quick archive mode. Press twice to start archiving. Indicator
blinks green when data is being written to backup device.
Universal Serial Bus (USB) port for additional devices such as a USB mouse,
CD/DVD burner, or USB Hard Disk Drive (HDD).
3. Instant Playback: Playback the recorded video from the last five minutes.
4. Audio On: Enable/disable audio output.
5. Snapshot: Capture a snapshot of a video
image.
TVN 11 Quick Start Guide 3
7. Digital Zoom: Enter digital zoommode.
8. Image Settings: Modify the image lighting levels.
9. Auxiliary Focus: Automatically focus the cameralens
10. Lens Initialization: Initialize the lens of a camera with a motorized lens
11. Stream Information: Display the real-time frame rate, bit rate, resolution and video compression.
Package contents
The TruVision NVR 11 (model TVN 11) is
shipped with the following items:
• IR (infrared) remote control (US only)
• Two AAA batteries for the remote control
(US only)
• AC power cord
• 12 VDC or 48 VDC PSU (depending on the
model)
• USB mouse
• NVR
• Rack mounts (8 and 16-channel models
only)
• TruVision NVR 11 Quick Start Guide
You can download the software and the
following manuals from our web site:
• TruVision NVR 11 User Manual
• TruVision Recorder Operator Guide
Installation environment
Refer to the user manual for detailed
information, but observe these important
requirements:
• Place the unit in a secure location.
• Ensure that the unit is in a well-ventilated
area.
• Do not expose the unit to rain or moisture.
Quick install
Recommended steps for setting up the
recorder:
1. Connect all the devices required to the
back panel of the recorder. See Figure 1
on page 1.
PoE recorder models:
Connect the IP cameras to the internal PoE
switches. Connect the recorder to the
network.
Non-PoE recorder models:
Connect the recorder to the network.
2. Connect monitor A to the VGA or HDMI output.
3. Connect the mouse to the USB port in the front panel.
4. Connect the power supplyto the unit and turn on the power.
5. Set up the unit with the required settings using the setup Wizard.
First time use
PoE recorders configure all cameras
simultaneously. When using a non-PoE
recorder, you must search for all cameras.
The configuration can then be customized as
required.
The recorder has an express installation
wizard that lets you easily configure basic
recorder settings when first used.
By default, the setup wizard will start once the
recorder has loaded. The wizard walks you
through some of the more important settings
of your recorder. Select the preferred
language for the system and then set the
administrator password. There is no default
password provided.
The wizard will then guide you through the
menus to set the time and date, network
configuration, HDD management, and
recording configuration.
When all the required changes have been
entered, click Finish to exit the wizard. The
recorder is now ready to use. Recording starts
automatically.
Operating the recorder
There are several ways to control the unit:
• Front panel control
• IR remote control
• Mouse control
• Web browser control
• Software (TruVision Navigator, TVRMobile)
Front panel
The buttons on the front panel control most
functions. See Figure 2 on page 2 for the
locations of the controls.
4 TVN 11 Quick Start Guide
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.