Interlogix TVD-5801 Installation Guide

TruVision Stainless Steel Dome Camera Installation Guide
Copyright
© 2018 United Technologies Corporat ion,
Trademarks
Trade names used in this document may be trademarks or
Manufacturer
Interlogix
Certificati on
FCC
Class A: This equipment has been tested and found to com ply with
FCC
This device complies with Part 15 of the FCC Rules. Operation is
ACMA
Notice! This is a Class A product. In a domestic envir onment this
Canada
This Class A digital apparatus complies with CAN I CES-003
European
This product and - if applicable - the supplied accessories too ar e
2012/19/EU (WEEE directive): Products marked with this symbol
Interlogix is part of UTC Climate, Controls & S ecurity, a unit of United Technologies Corporation. All ri ghts reserved.
and patents
registered trademarks of the manufactur ers or vendors of the respective products.
2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA Authorized EU manufacturing representat ive:
UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Net herlands
compli ance
compli ance
the limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interf erence when the equipment is operated in a commercial environment. Thi s equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction m anual, may cause harmful interference to radio communi cations. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required t o correct the interference at his own expense.
conditions
subject to the following two conditions: (1) This device may not cause harmf ul interference. (2) This Device must accept any interference receiv ed, including
interference that may cause undesired operati on.
product may cause radio int erference in which case the user may be required to take adequate measures.
(A)/NMB-3 (A). Cet appareil numérique de la classe A est conforme à la norme CAN ICES-003 (A)/NMB-3 (A).
Union
marked with "CE" and comply therefore with the applicabl e
directives
harmonized European standards li sted under the EMC Directive 2014/30/EU, the RoHS Directiv e 2011/65/EU.
cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, ret urn this product to your local supplier upon the purchase of equiv alent new equipment, or dispose of it at designated collection poi nts. For more information see: www.recyclethis.info.
Product
warnings
THESE PRODUCTS ARE INTENDED FOR SALE TO AND
Contact
For contact information go to: www.interl ogix.com or
and
disclaimers
INSTALLATION BY QUALIFIED PROFESSIONALS. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimer s and product safety information, please check www.firesecurityproducts.com /policy/product-warning/ or scan the QR code:
information
and manuals
www.firesecurityproducts.com To get translations for this and other product manual s go to:
www.firesecurityproducts.com

Content

Introduction 6
Product overview 6
Installation 6
Installation environment 6 Package contents 7 Camera description 9 IR illuminators 10 Alarm input and output connections 10 SD memory card installation 11
Mounting the dome camera 12 Mounting the TVJ-JBS junction box 12
Using the camera with an Interlogix NVR or Hybrid DVR or
another system 12
Using the camera with TruVision Navigator 13
Access the camera over the internet 13
Specifications 16
Pin definitions 17
Installation Guide 5

Introduction

Product overview

This is the installation guide for the TruVision Stainless Steel dome camera model:
TVD-5801 (2MPX camera, 2.8-12 mm lens)

Installation

This section provides information on how to install the cameras.

Installation environment

When installing your product, consider these factors:
Electrical: Install electrical wiring carefully. It should be
done by qualified service personnel. Always use a proper
PoE switch or a 12 VDC UL listed Class 2 or CE certified
power supply to power the camera. Do not overload the power cord or adapter.
Ventilation: Ensure that the location planned for the installation of the camera is well ventilated.
Temperature: Do not operate the camera beyond the specified temperature, humidity, or power source ratings. Humidity is below 90%. For the outdoor cameras that feature built-in heaters, the operating temperature range is -40 to 60°C (-40 to140°F)
Moisture: Do not expose the camera to rain or moisture or try to operate it in wet areas. Turn the power off
6 Installation Guide
immediately if the camera is wet and ask a qualified
DC12VIN
service person for servicing. Moisture can damage the
camera and also create the danger of electric shock.
Servicing: Do not attempt to service this camera yourself. Any attempt to dismantle or remove the covers from this product will invalidate the warranty and may also result in serious injury. Refer all servicing to qualified service personnel.
Cleaning: Do not touch the sensor modules with fingers. If cleaning is necessary, use a clean cloth with some ethanol and wipe the camera gently. If the camera will not be used for an extended period of time, put on the lens cap to protect the sensors from dirt.

Package contents

Check the package and contents for visible damage. If any components are damaged or missing, do not attempt to use the unit; contact the supplier immediately. If the unit is returned, it must be shipped back in its original packaging.
Package contents include the following:
Camera
Installation guide
Installation Guide 7
CD with configuration manual and TruVision Device Manager
Equipment disposal sheet
Battery disposal sheet
Drill template
Video test cable
Screws Drywall anchor
7.5 × 24.5 mm (4 pcs)
Torx driver
Screw
M4 × 25 mm (4 pcs)
Water joint: Provides
water resistance to network cable connector
8 Installation Guide
CAUTION: Use direct plug-in UL listed power supplies
1
2
3
4
5
6
9
DC
12VIN
7
8
10
11
12
13
use)
marked Class 2/CE certified or LPS (limited power source) of the required output rating as listed on the unit.

Camera description

Figure 1: Dome camera description and connectors
1. Bubble assembly
2. Lens
3. Dome liner
4. Rubber sealing
5. Base
6. Reset button
7. Serial port (for internal
Installation Guide 9
8. SD card slot
9. Video test port
10. Ethernet RJ45 PoE port
11. Alarm I/O
12. Audio I/O
13. 12 VDC power cable

IR illuminators

The camera’s built-in IR illumination provides high-quality video in low-light environments, even when there is no other illumination available.
You can configure the IR illumination using a web browser or a client software, such as TruVision Navigator. If the function is
enabled, the IR light is On when the camera enters night (black and white) mode. If disabled, the IR light is always Off.
The visible IR range may vary due to multiple factors such as weather, IR reflection level of objects in frame, lens
adjustment, and camera settings. Please refer to the camera datasheet for the standard IR range.
Note: Avoid installing the IR camera in close proximity to a solid object such as a tree or wall. The reflection will cause over-exposure and loss of visibility of detail in the field of view.

Alarm input and output connections

The alarm output can be used to turn on and off an external alarm device. Connect a 30 VDC/1A external power supply to the alarm output. If using an AC power supply, an external relay must be used to prevent electric shock and damage to the device. See Figure 2 below.
Figure 2: External alarm output
10 Installation Guide

SD memory card installation

To install the SD memory card in the dome camera
1. Loosen the three torx screws on the bubble assembly.
2. Insert the memory card into the SD card slot until it
clicks into place.
3. Reinstall the bubble assembly on the camera base.
Installation Guide 11

Mounting the dome camera

To mount the dome on a wall:
The TruVision Stainless Steel Dome Wall Mount (TVD-W BS, not included) is required to wall mount the dome camera.
Refer to the installation guides provided with the TVD-W BS wall mount for instructions on mounting the stainless steel dome camera to the wall.
To mount the dome on the ceiling:
The TruVision Stainless Steel Pendant Mount (TVP-PAS, not included) is required to ceiling mount the dome camera.
Refer to the installation guides provided with the TVP-PAS pendant mount for instructions on mounting the stainless steel dome camera to the ceiling.

Mounting the TVJ-JBS junction box

Refer to the installation guide provided with the TVJ-JBS junction box for instructions on mounting the camera in conjunction with the TVJ-JBS junction box.

Using the camera with an Interlogix NVR or Hybrid DVR or another system

Please refer to the NVR/DVR user manuals for instructions on connecting and operating the camera with these systems.
12 Installation Guide

Using the camera with TruVision Navigator

The camera can be connected to an Interlogix NVR, hybrid DVR, or directly to TruVision Navigator. Please refer to the user manual of TruVision Navigator and/or of the NVR or hybrid DVR for instructions.

Access the camera over the internet

Use the web browser to access and control the camera over the internet.
Note: Any changes made to the camera’s configuration only apply to this camera. Only authorized users should be able to modify camera settings.
When you first start up the camera, the Activation window appears. You must define a high-security admin password
before accessing the camera. There is no default password provided.
You can activate a password via a web browser and via TruVision Device Manager (included on the CD to find the IP
address of the camera).
To activate the camera via the web browser:
1. Power on the camera and connect the camera to the network.
2. Type the IP address into the address bar of the web browser and press Enter to enter the activation interface.
Installation Guide 13
Note:
The default IP address of the camera is
192.168.1.70.
For the camera to enable DHCP by default, you
must activate the camera via TruVision Device
Manager. Please refer to the following section, “To activate the camera via TruVision Device Manager.”
3. Type the password in the Password field.
Note: A valid password range must be between 8 and 16
characters. You can use a combination of numbers, lower
and upper case letters, and special characters : _ - , . * & @ / $ ? Space. The password must contain characters
from at least two of these groups. We also recommend
that you reset your password regularly. For high security systems, it is particularly recommended to reset the password monthly or weekly for better protection.
4. Confirm the password.
5. Click OK to save the password and enter the live view interface.
14 Installation Guide
6. Click the Configuration tab on the top of the screen and select the parameter to change.
Figure 3: Example of a configuration window
To activate the camera via TruVision Device Manager:
For instructions on how to activate the camera using TruVision
Device Manager, refer to the TruVision Device Manager User Manual. Go to www.interlogix.com/video/product/truvision-
device-manager and click Downloads.
Installation Guide 15

Specifications

Electrical
Voltage input
Power consumption
Miscellaneous
Connectors Operating temperature
Dimensions
Weight
Environmental rating
12 VDC, PoE+
Max. 16 W
Audio In/Out, Alarm In/Out, 12 VDC
165.4 × 130 mm
3.36 kg (7.41 lb.)
Power, Ethernet RJ45 PoE port
-40 to +60°C (-40 to +140°F)
(6.51 x 5.12 in.)
IP67
16 Installation Guide

Pin definitions

There are eight wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight and crossover cable connection:
Figure 4: Straight-through cable
1 White/Orange
2 Orange Orange 2
3 Whi te-Green Whi te-Green 3
4 Blue Blue 4
5 White/Blue White/Blue 5
6 Green Green 6
7 White/Brown White/Brown 7
8 Brown Brown 8
Figure 5: Cross-over cable
1 White/Orange
2 Orange Orange 2
3 Whi te-Green Whi te-Green 3
4 Blue Blue 4
5 White/Blue White/Blue 5
6 Green Green 6
7 White/Brown White/B rown 7
8 Brown Brown 8
Ensure that the connected cables have the same pin assignment and color as above before deploying them in the network.
White/Orange 1
White/Orange 1
Installation Guide 17
18 Installation Guide
Installation Guide 19
20 Installation Guide
Loading...