Interlogix TVD-2401, TVD-2403, TVD-4403, TVD-4401 Installation Manual

© 2015 United Technologies Corporation. All rights reserved. P/N 1072939-EN • REV A • ISS 26MAR15
Interlogix is part of UTC Building & Industrial Systems, a unit of United Technologies Corporation. All rights reserved.
TruVision High Definition TVI Dome Installation
Guide
Product overview
This is the Installation Guide for TruVision High Definition TVI dome TVD-2401/TVD-4401 and TVD-2403/TVD-4403. This
guide describes a standard installation.
Package contents:
Camera with power and
video output cables
3 screws and 3 anchors
for wall or ceiling
installation
Template
Installation Guide
WEEE and Battery Disposal
CD
Camera description
TVD-2401/TVD-4401
1.
Base
2.
IR LED
3.
Lens
4. Dome liner
5. Housing
6.
Power supply
7.
TVI Video output cable (grey)
TVD-2403/TVD-4403
1. Base
2. IR LED
3. Lens
4. Dome liner
5. Housing
6. Power supply
7. TVI video output cable (grey)
8. CVBS video output cable
(black)
Note:
Please check the camera output settings before setting up a system. The TVI video output can be only connected to DVR with TVI signal input. The CVBS output supports the standard monitor, test monitor, encoder and DVR.
For TVD-2403/TVD-4403, you can connect the white and black line ends of the WDR switch cable to enable the Wide Dynamic Range function. The WDR function is disabled by default. If WDR is enabled, the CVBS output will be blocked out, and only TVI output is available.
Installation
To install the camera on a ceiling:
1. Using the template, place it level against the mounting surface and mark the position of the mounting holes.
2. Following all local codes, drill and prepare the mounting holes.
Drill Template
Hole A: for cables routed through the ceiling screw hole 1: for Mounting Base
1
1
1
A
2 / 3 P/N 1072939-EN • REV A • ISS 26MAR15
3. Loosen the screws with wrech to remove the housing.
4. Securely fasten the mounting base to the mounting surface with the screws.
5. Using a 75 ohm coaxial video cable, connect the camera
TVI video output and a TVI DVR, and connect a 12 VDC power supply to the camera power cable.
6. Adjust the surveillance angle according to the figure below.
7. Re-attach the housing to the base.
Programming
Programming on TVI output:
Programming on TVI output is available for TVD-2403/TVD­4403 only.
Once the camera hardware has been installed, you can configure the camera settings on the TVI DVR.
Please select PTZ protocol as TruVision Coax and click menu button to call up the camera menu.
For more details, please see the TVI DVR user manual.
Programming on CVBS output:
Programming on CVBS output is available for TVD-2403/TVD­4403 only.
Programming on CVBS output, you need to connect a monitor and a TVS-C200 controller (purchase separately) as following system figure.
The TVS-C200 has one male BNC output and a female output. Please connect the male output to camera’s CVBS output and female output to a monitor.
Menu
Specifications
Power supply
12 VDC
Current
TVD-2401/TVD-4401:
Max. 300 mA
TVD-2403/TVD-4403:
Max.333 mA
Power consumption
TVD-2401/TVD-4401:
Max. 3.5W
TVD-2403/TVD-4403:
Max. 4W
Weight
345 g (0.76 lb.)
Dimensions (Ø × L)
111 x 82 mm (4.4 x 3.2 in. )
Regulatory information
Manufacturer
Interlogix.
2955 Red Hill Avenue, Costa Mesa, CA 92626
5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The
Netherlands
FCC compliance
Class A: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and
Loading...