Interlogix TVD-4402 User Manual

Page 1
TruVisio
Vandal Dome Installation
Guide
TVD TVD-2404/TVD-4404
P/N 1072937-EN • REV A • ISS 12MAR15
n High Definition TVI
Page 2
Content
Product overview 3 Camera description 5 Installation 7 Programming 12 Menu 15
Specifications 17 Legal and Regulatory information 18
2 Installation Guide
Page 3
Product overview
This is the Pocket Guide for TruVision High Definition TVI dome TVD-2402/TVD-4402 and TVD­2404/TVD-4404. This guide describes a standard installation.
Package contents:
Camera with power
and video output cables
Template
Installation Guide 3
4 screws and 4
anchors for wall or ceiling installation
3 screws for install
the camera to back box
Page 4
Hex wrench
Monitor output
cable
Spare rubber
knockout
There is a rubber knockout on the camera back box. This one is for future use.
CD
4 Installation Guide
Installation Guide
WEEE and Battery Disposal
Page 5
Camera description
cable (black)
5
4
6
8
1
3
2
9
7
1. Dome liner
2. Bubble
3. Lens
4. Power cable
5. CVBS video output
Installation Guide 5
6. TVI video output cable (grey)
7. Back box
8. DIP switch
9. Menu button
Page 6
Note:
Please check the camera output settings
before setting up a system. The TVI video output can be only connected to DVR with TVI signal input. The CVBS output supports
the standard monitor, test monitor, encoder and DVR.
For TVD-2402/TVD-4202, the CVBS and TVI output can not be performed at the same time, you can use the built-in DIP switch to select the camera video output.
For TVD-2404/TVD-4404, the built-in DIP
switch is used to enable/disable WDR feature, when WDR feature is enabled, the CVBS
output will be blocked out.
6 Installation Guide
Page 7
DIP switch
Installation
To install the camera on a ceiling:
1. Using the template, place it level against the mounting surface and mark the position of the mounting holes.
Installation Guide 7
Page 8
2. Following all local codes, drill and prepare the mounting holes.
3. Remove the camera from its back box.
4. Loosen the three set of screws on the edge of the bubble with the supplied hex wrench.
5. Remove the bubble and the dome liner.
6. Secure the back box to the ceiling with the supplied screws.
8 Installation Guide
Page 9
Note: Please remove the rubber knockout for cable routing outside of the camera, when required.
7. Using a 75-ohm coaxial video cable, connect
the camera TVI video output and a TVI DVR, and connect a 12 VDC or 24 VAC power
supply to the power cable.
8. Align the camera with the back box and tighten the set screws to secure the camera to the back box.
Installation Guide 9
Page 10
7. Adjust the surveillance angle:
1) View the camera image on a monitor.
2) Rotate the panning table to adjust the pan direction [0 to 355°].
3) Loosen the tilting lock screw.
4) Rotate the tilting table to adjust the tilt direction [0 to 90°].
5) Tighten the tilting lock screw.
6) Rotate the camera lens holder [0 to 355°] to adjust the lens to the surveillance angle.
10 Installation Guide
Page 11
8. Zoom and focus adjustment.
~
~
~
1) View the camera image using the monitor.
2) Loosen the zoom lever and move the screw between T (Tele) and W (Wide) to obtain the appropriate angle of view.
3) Tighten the zoom lock screw.
4) Loosen the focus lever and move the screw between F (Far) and N (Near) to obtain the optimum focus.
5) Tighten the focus lock screw.
Installation Guide 11
Page 12
Zoom
Focus
Programming
TVI
Programming on TVI output:
Once the camera hardware has been installed, you can configure the camera settings on the TVI DVR.
12 Installation Guide
Page 13
Please select PTZ protocol as TruVision Coax and
TVI
CVBS
click menu button to call up the camera menu.
For more details, please see the TVI DVR user
manual.
Programming on CVBS output:
Programming on CVBS output, you need to connect a monitor and a TVS-C200 controller (purchase separately) as following system figure.
The TVS-C200 has one male BNC output and a
female output. Please connect the male output to camera’s CVBS output and female output to a monitor.
TVD-2402/TVD-4402
Installation Guide 13
Page 14
The camera has CVBS and TVI selectable video
output. Please set the built-in DIP switch to CVBS for viewing the program on a standard monitor.
In such case, its TVI will be blocked out until you finish the settings and change DIP switch back to TVI.
TVD-2404/TVD-4404
The camera has the CVBS and TVI dual video
output. The built-in DIP switch is for WDR/CVBS selection.
Please set the built-in DIP switch to CVBS for viewing the program on a standard m onitor.
When the programing is finished, you may change the DIP to WDR to enable the WDR feature. In such case, the CVBS output will be blocked out.
If the DIP is set as CVBS, the WDR feature will be disabled, and the camera has CVBS and TVI output
available at the same time.
14 Installation Guide
Page 15
Menu
TVD-2402/TVD-4402:
Installation Guide 15
Page 16
TVD-2404/TVD-4404:
16 Installation Guide
Page 17
Specifications
Power supply
24 VAC/12 VDC
Current
Power consumption
TVD-2402/ TVD-4402:
Weight Dimensions
TVD-2402/ TVD-4402:
(net) 641 g / 1.41 lb. (without back box)
Installation Guide 17
12 VDC: Max. 300 mA 24 VAC: Max. 210 mA TVD-2404/TVD-4404: 12 VDC: Max. 375 mA 24 VAC: Max. 270 mA
12 VDC: Max. 3.5W 24 VAC: Max. 5W TVD-2404/TVD-4404: 12V DC: Max. 4.5W 24V AC: Max. 6.5W
932 g / 205 lb. (with back box)
Ø145.3 x 124.2 mm 5.72 x 4.89 in. )
Page 18
Legal and Regulatory
information
Class A: This equipment has been tested and found to comply with
erated in a commercial environment. This equipment generates,
and used in accordance with the instruction manual, may cause
Copyright:
© 2015 United Technologies Corporation,
Interlogix is part of UTC Building & Industrial Systems, a unit of
United Technologies Corporation. All rights reserved.
Trademarks and patents:
Trade names used in this document may be trademarks or
registered trademarks of the manufacturers or vendors of the respective products.
Manufacturer:
Interlogix 2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA Authorized EU manufacturing representative:
UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands
Certification:
N4131
FCC compliance: Class A
the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is op
uses, and can radiate radio frequency energy and, if not installed
18 Installation Guide
Page 19
harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ACMA compliance
Notice! This is a Class A product. In a domestic environment this
product may cause radio interference in which case the user may
be required to take adequate measures.
Canada
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme
NMB-0330 du Canada.
European Union directives:
12004/108/CE (EMC directive): Hereby, UT C Fire & Security declares
that this device is in compliance with the essential requirements and other relevant provisions of Directiv e 2004/108/EC.
Contact information:
For contact information, see www.interlogix.com or
www.utcfssecurityproducts.eu
2012/19/EU (WEEE directi ve): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return t his product to your
local supplier upon the purchase of equiv alent new equipment, or dispose of it at designated coll ection points. For more inf ormation see: www.recyclethis.info.
Installation Guide 19
Page 20
Loading...