© 2015 United Technologies Corporation. All rights reserved. P/N 1072937-EN • REV A • ISS 26MAR15
Interlogix is part of UTC Building & Industrial Systems, a unit of United Technologies Corporation. All rights reserved.
TruVision High Definition TVI Vandal Dome
Installation Guide
Product overview
This is the installation guide for TruVision High Definition TVI
dome TVD-2402/TVD-4402 and TVD-2404/TVD-4404. This
guide describes a standard installation.
Package contents:
for wall or ceiling
installation
camera to back box
Hex wrench
Monitor output cable
There is a rubber knockout on the camera
back box. This one is for future use.
• WEEE and Battery
Disposal
Camera description
1. Dome liner
2. Bubble
3. Lens
4. Power cable
5. CVBS video output cable
6. TVI video output cable
(grey)
7. Back box
8. DIP switch
9. Menu button
Note:
Please check the camera output settings before setting up a
system. The TVI video output can be only connected to DVR
with TVI signal input. The CVBS output supports the standard
monitor, test monitor, encoder and DVR.
For TVD-2402/TVD-4202, the CVBS and TVI output can not be
performed at the same time, you can use the built-in DIP
switch to select the camera video output.
For TVD-2404/TVD-4404, the built-in DIP switch is used to
enable/disable WDR feature, when WDR feature is enabled,
the CVBS output will be blocked out.
DIP switch

2 / 4 P/N 1072937-EN • REV A • ISS 26MAR15
Installation
To install the camera on a ceiling:
1. Using the template, place it level against the mounting
surface and mark the position of the mounting holes.
2. Following all local codes, drill and prepare the mounting
holes.
3. Remove the camera from its back box.
4. Loosen the three set of screws on the edge of the bubble
with the supplied hex wrench.
5. Remove the bubble and the dome liner.
6. Secure the back box to the ceiling with the supplied
screws.
Note: Please remove the rubber knockout for cable
routing outside of the camera, when required.
7. Using a 75-ohm coaxial video cable, connect the camera
TVI video output and a TVI DVR, and connect a 12 VDC
or 24 VAC power supply to the power cable.
8. Align the camera with the back box and tighten the set
screws to secure the camera to the back box.
7. Adjust the surveillance angle:
1) View the camera image on a monitor.
2) Rotate the panning table to adjust the pan direction [0
to 355°].
3) Loosen the tilting lock screw.
4) Rotate the tilting table to adjust the tilt direction [0 to
90°].
5) Tighten the tilting lock screw.
6) Rotate the camera lens holder [0 to 355°] to adjust the
lens to the surveillance angle.
8. Zoom and focus adjustment.
1) View the camera image using the monitor.
2) Loosen the zoom lever and move the screw between T
(Tele) and W (Wide) to obtain the appropriate angle of
view.
3) Tighten the zoom lock screw.
4) Loosen the focus lever and move the screw between F
(Far) and N (Near) to obtain the optimum focus.
5) Tighten the focus lock screw.
Programming
Programming on TVI output:
Once the camera hardware has been installed, you can
configure the camera settings on the TVI DVR.
Please select PTZ protocol as TruVision Coax and click menu
button to call up the camera menu.
For more details, please see the TVI DVR user manual.
Programming on CVBS output:
Programming on CVBS output, you need to connect a monitor
and a TVS-C200 controller (purchase separately) as following
system figure.
The TVS-C200 has one male BNC output and a female output.
Please connect the male output to camera’s CVBS output and
female output to a monitor.

P/N 1072937-EN • REV A • ISS 26MAR15 3 / 4
TVD-2402/TVD-4402
The camera has CVBS and TVI selectable video output.
Please set the built-in DIP switch to CVBS for viewing the
program on a standard monitor.
In such case, its TVI will be blocked out until you finish the settings and
change DIP switch back to TVI.
TVD-2404/TVD-4404
The camera has the CVBS and TVI dual video output. The
built-in DIP switch is for WDR/CVBS selection.
Please set the built-in DIP switch to CVBS for viewing the
program on a standard monitor.
When the programing is finished, you may change the DIP to
WDR to enable the WDR feature. In such case, the CVBS
output will be blocked out.
If the DIP is set as CVBS, the WDR feature will be disabled,
and the camera has CVBS and TVI output available at the
same time.
Specifications
TVD-2402/ TVD-4402:
12 VDC: Max. 300 mA
24 VAC: Max. 210 mA
TVD-2404/TVD-4404:
12 VDC: Max. 375 mA
24 VAC: Max. 270 mA
consumption TVD-2402/ TVD-4402:
12 VDC: Max. 3.5W
24 VAC: Max. 5W
TVD-2404/TVD-4404:
12V DC: Max. 4.5W
24V AC: Max. 6.5W
(net) 641 g / 1.41 lb. (without back box)
932 g / 205 lb. (with back box)
Ø145.3 x 124.2 mm
(Ø 5.72 x 4.89 in. )
Menu
TVD-2402/TVD-4402:
TVD-2404/TVD-4404:
Regulatory information
Interlogix.
2955 Red Hill Avenue, Costa Mesa, CA 92626
5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands
Class A: This equipment has been tested and
found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated in a
commercial environment. This equipment
generates, uses, and can radiate radio frequency
energy and, if not installed and used in
accordance with the instruction manual, may
cause harmful interference to radio
communi
cations. Operation of this equipment in a
residential area is likely to cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
Notice! This is a Class A product. In a domestic
environment this product may cause radio
interference in which case the user may be
required to take adequate measures.
This Class A digital apparatus complies with
Canadian ICES-003.
Cet appareil numérique de la classe A est
conforme à la norme NMB-0330 du Canada.
European Union
directives
12004/108/EC (EMC directive): Hereby, UTC Fire
& Security declares that this device is in
compliance with the essential requirements and
other relevant provisions of Directive
2004/108/EC.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info.
© 2015 United Technologies Corporation.
Interlogix is part of UTC Building & Industrial
Systems, a unit of United Technologies
Corporation. All rights reserved.

4 / 4 P/N 1072937-EN • REV A • ISS 26MAR15
The trade names used in this document may be
trademarks or registered trademarks of the
manufacturers or vendors of the respective
products.
Contact information
For contact information, see www.interlogix.com or
www.utcfssecurityproducts.eu.