Interlogix TVC-N220-1-N-R, TVC-M5220-1-N-R, TVC-M2220-1-N-R, TVC-M3220-1-N-R User Manual

TruVi s i on IP Cam Open­Standards User Manual
P/N 1076513B-EN • REV 1.0 • ISS 20MAR12
©
Interlogix, UTC
Other trade names used in this document may be trademarks or registered tradem ar k s of the manufacturers or vendors of the respectiv e product
UTC Fire & Security Ameri c as Corporation, Inc. 2955 Red Hill Avenue, Costa Mesa, CA 92626
Authorized E U manufac turing representativ e: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands
N4131
Cla ss A: the limits for a Class A digital dev ice, pursuant to part 15 of the FCC Rules. These limit s are designed to provide reasonable protection against harmful interference whe commercial env ir onm ent. This equipment generates, uses, and can radiate radio f r equenc y ener gy and, if not installed and used in accordance with the instruction manual, may cause harmful interfer enc e to radio c ommunications a residential area is li k ely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Notice!
product may cause radi o interference in which case the user may be required to take adequate measures.
This Class A digital appar atus complies with Canadian ICES Cet appareil numérique de la classe A est conforme à la norme
NMB
1 declares that t his device is in compliance with the essential requirements and other r elevant provisions of Directive 2004/108/EC
2002/96/EC (WEEE dir ec ti cannot be disposed of as unsorted municipal waste in the European Union. For proper rec y cli ng, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated co www.recyclethis.info.
For contact information www.utcfssecurityproducts.eu
www.interlogix.com/customer
2012 UTC Fire & Security. All right s reserved.
TruVision names and logos are trademarks of
Fire & Security.
s.
-5923, USA
This equipment has been tested and found to comply with
n the equipment is operat ed in a
. Operation of this equi pm ent in
This is a Class A product. In a domestic env ir onm ent this
-0330 du Canada.
2004/108/EC (EMC dir ec tive): Hereby, UTC Fire & Security
.
ve): Products marked with this symbol
llection points. For more information see:
, see www.interlogix.com or
.
-003.
Customer suppor
-support
Content
Chapter 1 Introduction 1
Product overview 1 Features 1
Chapter 2 Installation 3
Installation environment 3 Package contents 4 Cable requirements 4 Camera description 5 Connections 6 Accessing the SDHC card 7 Setting up the camera 7 Mounting the camera on a ceiling 8 Using the camera with TVR 60/ TVN 20/ TVN 40/ LNVR and other
systems 9
Using the camera with TruVision Navigator 9
Chapter 3 Network and streaming configuration 11
Checking your Web browser security level 11 Accessing the camera over the internet 13 Overview of the camera Web browser 14 Configuring the camera’s network settings 16 Information about the camera 19 Network parameters 19 Serial port settings 21
Chapter 4 Camera configuration 23
Camera parameters 23 Defining how information is displayed on screen 24 Defining the system time 25 Alarm parameters 26 Events scheduling 27 Defining recording param eters 28 Motion detection alarms 31 Adding extra on-screen text 34 Configuring the video image 34
Chapter 5 Camera management 37
User management 37 Formatting the SDHC card 39 Restoring default settings 40 Upgrading the firmw are 40 Rebooting the camera 41
TruVision IP Cam Open-Standards User Manual i
Chapter 6 Camera operation 43
Logging on and off 43 Live mode 43 Playing back recorded video 44 Searching event logs 46 Archiving recorded files 48 Using presets 49
Appendix A Specifications 51 Appendix B Pin definitions 53
Index 55
ii TruVision IP Cam Open-Standards User Manual
Chapter 1
Introduction

Product overview

This is the user manual for TruVision IP Cam Open-Standards camera models:
- TVC-N220-1-N(-P) (VGA)
- TVC-N240-1-N(-P) (4CIF WDR)
- TVC-M1220-1-N(-P) (1.3 megapixel)
- TVC-M2220-1-N(-P) (2.0 megapixel)
- TVC-M3220-1-N(-P) (3.0 megapixel)
- TVC-M5220-1-N(-P) (5.0 megapixel)

Features

This section describes the camera features.
Supports TCP/IP, HTTP, DNS, RTP/RTCP and PPPoE protocols Programming and setup through a brow s er interface Live viewing over the network 50/60 Hz selectable flicker control Mono, bi-directional audio Digital pan/tilt/zoom (PTZ) Supports remote upgrades and maintenance H.264 video compression with dual capability Supports full HD, HD, 4CIF, 2CIF, CIF and QCIF SDHC card for local storage
TruVision IP Cam Open-Standards User Manual 1
0BChapter 1: Introduction
2 TruVision IP Cam Open-Standards User Manual
Chapter 2
Installation
This chapter provides information on how to install the cameras.

Installa tion environment

When installing your product, consider these factors:
Electrical: Install electrical wiring carefully. It should be done by qualified service personnel. Always use a proper PoE switch or a 12 VDC UL listed Class 2 or CE certified power supply to power the camera. Do not overload the power cord or adapter.
Ventilation: Ensure that the location planned for the installation of the camera is well ventilated.
Temperature: Do not operate the camera beyond the specified temperature, humidity or power source ratings. The operating temperature of the camera is between -10 to +60°C (14°F to 140°F). Humidity is below 90%.
Moisture: Do not expose the camera to rain or moisture, or try to operate it in wet areas. Turn the power off immediately if the camera is wet and ask a qualified service person for servicing. Moisture can damage the camera and also create the danger of electric shock.
Servicing: Do not attempt to service this camera yourself. Any attempt to dismantle or remove the covers from this product will invalidate the warranty and may also result in serious injury. Refer all servicing to qualified service personnel.
Cleaning: Do not touch the sensor modules with fingers. If cleaning is necessary, use a clean cloth with a some ethanol and wipe the camera gently. If the camera will not be used for an extended period of time, put on the lens cap to protect the sensors from dirt.
TruVision IP Cam Open-Standards User Manual 3
1BChapter 2: Installation

Package conten ts

Check the package and contents for visible damage. If any components are damaged or missing, do not attempt to use the unit; contact the supplier immediately. If the unit is returned, it must be shipped back in its original packaging.
Package contents:
Camera
Hex wrench
C-mount adapter
Multilingual quick start gu ide
CD with user manual in several languages
CAUTION: Use direct plug-in UL listed power supplies marked Class 2/CE certified or LPS (limited power source) of the required output rating as listed on the unit.

Cable requirements

For proper operation, adhere to the following cable and power requirements for the cameras. Category 5 cabling or better is recommended. All network cabling must be installed according to applicable codes and regulations.
Table 1 below lists the requirements for the cables that connect to the camera.
Table 1: Recommended cable requirements
Requirements
For RS-485: 22 gauge (0.64 mm) shielded, two-conductor, twisted-pair
(STP) cable
75 ohm RS-59 coaxial cable with BNC ends
12 VDC cable
4 TruVision IP Cam Open-Standards User Manual
1BChapter 2: Installation
1.
2.
3.
4.
5. Auto iris lens cable. Not included.

Camera description

Figure 1: Camera dimensions
Figure 2: Side elevation of the camera
Bracket mounting holes.
Can be repositioned t o the ot her si de of t he camera.
Camera. C-mount adaptor (for C-mount lenses only). Lens (auto iris lens shown. A manual iris
has no cable.)Not included.
6. Auto iris lens connector. Video-type aut o iris lens connection:
A. Power; B. NC (no connection); C. GND; D. Video
DC-type auto iris lens connection:
A. Damping coil (-); B. Damping coil ( +); C. Driving coil (+); D. Driv ing c oil ( -)
TruVision IP Cam Open-Standards User Manual 5
1BChapter 2: Installation
Connect to ground.

Connections

A qualified service person, complying with all applicable codes, should perform all required hardware installation.
Note: Do not attempt to extend the power/data cable connection using RJ45 couplers and Cat5 cable. Only use the data cable connection provided.
Note: Use 12 VDC or PoE.
Figure 3: Wiring the camera
1. Et her net RJ45 PoE port Connect to network devices.
2. Video output Connect to a CCTV monitor.
3. Audio output Connect to an audio output . Line level, 600 Ω.
4. Audio input Connect to an audio input.
2.0 to 2.4 Vp-p, 1 kΩ.
5. Power LED Illuminated when power i s connected.
6. Power suppl y Connect +12 VDC power supply.
7. RS-485 D+, D­Connect to an RS-485 device such as a PTZ dome camera.
8. Alarm outputs Connect 1A/1B and 2A/2B to alarm output devices.
9. Alarm inputs Connect IN1/GND and IN2/GND to alarm input devices.
10. Ground
Note: The alarm output can be used to turn on and off an external alarm device.
Connect a 12 VDC/30 mA external power supply to the alarm output. See Figure 4 below.
6 TruVision IP Cam Open-Standards User Manual
1BChapter 2: Installation
SDHC card slot
Figure 4: External alarm output

Accessing the SDHC card

Insert an SDHC card up to 32GB for local storage as a backup in case the network fails, for example (see Figure 5 below). The card is not supplied with the camera.
Video and log files stored on the SDHC card can only be accessed via the Web browser. You cannot access the card using TruVision Navigator, TVR 60 or TVR 20.
Figure 5: SDHC card slot location in the cameras

Setting up the camera

Note: If the light source where the camera is installed experiences rapid, wide-
variations in lighting, the camera may not operate as intended.
To quickly put the camera into operation:
1. Connect the lens to the camera.
2. Prepare the mounting surface.
3. Mount the camera to the ceiling using the appropriate fasteners. See “Mounting the camera on a ceiling” on page 8.
TruVision IP Cam Open-Standards User Manual 7
1BChapter 2: Installation
4. Connect the cables to the camera. See “Connections” on page 6.
5. Set up the camera’s network and streaming parameters so that the camera can be controlled over the network. See Chapter 3 Network and streaming configuration” on page 11.
6. Program the camera to suit its location. See “Chapter 4 Camera configuration” on page 23.

Mounting the camera on a ceiling

Mount the camera on a ceiling. It is not recommended for mounting on a wall. When installing the camera, please use the optional mounting bracket, which is
sold separately.
To mount the camera on a ceiling:
1. Using the mounting bracket as a template, place it level against the mounting surface and mark the position of the mounting holes.
2. Following all local codes, drill and prepare the mounting holes.
3. Securely fasten the mount to the mounting surface with the appropriate fasteners.
4. If needed, seal all mounting holes so that no moisture can leak into the mounting surface.
5. Screw the camera into the mounting bracket. Ensure that the camera is firmly attached to the bracket.
6. Connect a 75 ohm coaxial video cable to the video cable, and connect a 12 VDC power supply to the power cable or use a PoE switch.
7. Adjust the camera position and angle as required.
8 TruVision IP Cam Open-Standards User Manual
1BChapter 2: Installation
8. Connect a lens to the camera. For optimal performance, use an autoiris lens.

Using the camera with TVR 60/ TVN 20/ TVN 40/ LNVR and other systems

Please refer to the head-end user manuals for instructions on connecting and operating the camera with these systems.

Using the camera with TruVision Navigator

A camera must be connected to a TVR 60/ TVN 20/ TVN 40 in order to be operated by TruVision Navigator. Please refer to the TruVision Navigator user manual for instructions on operating the camera with the TruVision Navigator.
TruVision IP Cam Open-Standards User Manual 9
Chapter 3
Net work and streaming configuration
This chapter explains how to configure the camera network settings. The cameras can be configured and controlled using an internet browser such as
Microsoft Internet Explorer (IE). The procedures described use Microsoft Internet Explorer (IE) web browser. The steps are similar with other browsers.
You must have administrator rights on your PC in order to configure the cameras over the internet.

Checking your Web browser security level

When using the Web browser interface, you can install ActiveX controls to connect and view video using Internet Explorer. However, you cannot download data, such as video and images due to the increased security measure. Consequently you should check the security level of your PC so that you are able to interact with the cameras over the Web and, if necessary, modify the Active X settings.
Configuring IE ActiveX controls
You should confirm the ActiveX settings of your Web browser.
To change the Web browser’s security level:
1. In Internet Explorer click Internet Options on the Tools menu.
2. On the Security tab, click the zone to which you want to assign a Web site under “Select a Web content zone to specify its security settings”.
3. Click Custom Level.
TruVision IP Cam Open-Standards User Manual 11
2BChapter 3: Network and streaming configuring
4. Change the ActiveX controls and plug-ins options to Enable and click OK.
- or ­Under Reset Custom Settings, click the security level for the whole zone in
the Reset To box, and select Low. Click Reset. Then click OK to the Internet Options Security tab screen.
5. Click Apply in the Internet Options Security tab screen.
12 TruVision IP Cam Open-Standards User Manual
2BChapter 3: Network and streaming configuring
Windows Vista and 7 users
Internet Explorer for Windows Vista and Windows 7 operating systems have increased security measures to protect your PC from any malicious software being installed.
To have complete functionality of the Web browser interface with Windows Vista and Windows 7, do the following:
• Run the Browser interface and the DVR player application as an administrator in your workstation
• Add the camera’s IP address to your browser’s list of trusted sites
To add the camera’s IP address to Internet Explorer’s list of trusted sites:
1. Open Internet Explorer.
2. Click Tools, and then Internet Options.
3. Click the Security tab, and then select the Trusted sites icon.
4. Click the Sites button.
5. Clear the “Require server verification (https:) for all sites in this zone box.
6. Enter the IP address in the “Add this website to the zone” field.
7. Click Add, and then click Close.
8. Click OK in the Internet Options dialog screen.
9. Connect to the camera for full browser functionality.

Accessing the camera over the internet

Use the Web browser to access and configure the camera over the internet. It is recommended that you change the administrator password once the set up
is complete. Only authorized users should be able to modify camera settings. See “User management” on page 37 for further inform at ion.
To access the camera online:
1. In the Web browser enter the camera’s IP address (default is 192.168.1.70). Use the tool, IP Finder, enclosed on the CD to find the IP address of the camera.
The Login dialog box appears. Note: Ensure that the Active X controls are enabled.
2. Enter your user name and password. User name: admin Password: 1234
Click OK. The Web browser screen appears in live mode.
TruVision IP Cam Open-Standards User Manual 13
2BChapter 3: Network and streaming configuring
Note: You can stop and start live view by clicking the Start/stop live view
button on the bottom of the screen.

Overview of the camera Web browser

The camera Web browser lets you view, record, and play back recorded videos as well as manage the camera from any PC with Internet access. The browser’s easy-to-use controls give you quick access to all camera functions. See Figure 6 on page 15.
Only one camera is accessible from a single Web browser window. If there is more than one camera connected over the network, open a separate Web browser window for each individual camera.
Note: Any changes made to the camera’s configuration only apply to this
camera. The configuration of other devices that may be connected to the camera, such as cameras or DVRs, is not changed.
14 TruVision IP Cam Open-Standards User Manual
2BChapter 3: Network and streaming configuring
when an SDHC card is inserted in the cam er a.
Figure 6: Web browser interface
Item Name Description
1. PTZ controls For future use.
2. Live view Click to view live video.
3. Playback Click to play back video.
4. Log Click to search for event logs. There are four main
informati on types: Al l, Alarm, Notificati on and Operation Note: The Playback and Log f unctions can only be used
5. Configuration Click to display the c onfiguration screen for setting up the
camera. See Figure 7 on page 17.
6. Viewer Click to view liv e or playback v ideo. Time, date and camera
name are displayed here.
7. Current user Displays current user logged on.
8. Exit Click to log out from the system . T his can be done at
anytime.
9. Full screen Click to view as full screen.
The top toolbar is not visible in full-screen mode.
10. Start/stop live view Click to start/stop live view.
11. Capture Click to take a snapshot of t he v ideo. T he snapshot will be
12. Start/stop r ec or ding Click to record live video.
TruVision IP Cam Open-Standards User Manual 15
saved to the default folder in JPEG format. See “Local configuration” on page 17 for more information.
Loading...
+ 43 hidden pages