TruVision Box Camera Outdoor Housing
with Heater (TVC-OH2-H) and Wall Mount
(TVC-M2-WM) Installation Instructions
Dimensions
:
:
ccessories:
dimensions
P/N 1073110-EN • REV C • ISS 02FEB 17 1 / 4

1/4 - 20 UNC × 10, 2 pcs
sed to attach the box camera to camera base plate.
Supported cameras
The housing can be used with the following box
cameras:
TVI/Analog Box
Came ra
TVC-4401, TVC-2401
B: 1/4 – 20 UNC × 14, 2 pcs
attach the TVC-OH2-H to the wall mount bracket
-M2-WM).
of TVC-M2-WM:
297.3 × 88 × 122.9 mm (11.7 × 3.5 × 4.8 in.)
IP Box Camera
TVC-1201, TVC-3201, TVC-1202, TVC-
3202,
TVC-5401, TVC-5402, TVC-5403
Installation
The housing is shipped with a TVC-M2-WM box
camera wall mount.
To attach a box camera to the box camera
outdoor housing (TVC-OH2-H):
Note: Prior to installing the TVC-OH2-H housing, run
the interconnect cables and mount the wall bracket
(TVC-M2-WM). Refer to the TVC-M2-WM Wall
Mount Installation Instructions.
1. Loosen the two latches located on the side of
the TVC-OH2-H to release the housing cover.
Lift the housing cover open.
2. Loosen the four camera base plate screws and
remove the base plate from the camera
housing. Attach the box camera to the base
plate, using the two A screws.
-M2-WM: 473 g (1.04 lbs.)
2 / 4 P/N 1073110-EN • REV C • ISS 02FEB 17

Note: You must install the appropriate
lens on the box camera before this step.
Please choose a lens with specifications
that are suitable for the application.
3. Install the camera and base plate assembly in
the housing. Tighten the four screws to keep
the camera assembly firmly in place.
4. Attach the housing to the TVC-M2-WM wall
mount bracket by using the two B screws.
5. Route the cables into the housing through the
cable gland.
Note: Please ensure that the power
supply is OFF during installation.
Terminals:
24 VAC output: Connect the camera
24 VAC input.
12 VDC: Connect the camera 12 VDC
power input. The positive/ negative
terminals should be distinguished.
RS-485 Port: Reserved for wiper control
(the wiper feature is not supported in this
model)
Note: 24 VAC/4 A UL listed Class 2 or
CE certified power supply is required
(purchased separately) for the device to
function properly.
The fan and heater are prewired at the
factory.
7. Connect the power and video coax cable
and/or Ethernet cable to the box camera.
Power a 12 VDC camera:
6. Connect the power supply (purchased
P/N 1073110-EN • REV C • ISS 02FEB 17 3 / 4
separately) cable to the 24 VAC input
terminals on the terminal panel.
24 VAC input

24 VAC camera power
supply
Power consumption
Environmental rating
be trademarks or registered trademarks of the
rights reserved.
Climate, Controls & Security, a unit of United
Technologies Corporation.
Power a 24 VAC camera:
3. When you have completed connecting the
cables, power on the housing, adjust the lens
to zoom and focus.
Specifications
445.3 × 169.2 × 110 mm
(17.5 × 6.7 × 4.3 in )
1900 g (4.2 lbs.)
-40 to +60 ℃ (-40 to +140 °F )
Heater on: 5 ℃ ±5 ℃
for constant temperature;
Fan on: 40 °C ±5 ℃, for heat
dissipation
supply 24 VAC 4 A. Purchased separately.
40 W max.
IP66
Legal and regulatory
information
The trade names used in this document may
manufacturers or vendors of the respective
products.
2017 United Technologies Corporation. All
Interlogix is part of UTC
Contact information
4. Close the cover of the housing and fasten the
clamps to finish the installation.
4 / 4 P/N 1073110-EN • REV C • ISS 02FEB 17
For contact information, see www.interlogix.com or
www.utcfssecurityproducts.eu.