Interlogix TruVision TVD-2401, TruVision TVD-4401, TruVision TVD-2403, TruVision TVD-4403 Installation Manual

Page 1
TruVision High
Definition TVI
Dome Installation Guide
TVD
TVD-2403/TVD-4403
P/N 1072939-EN • REV A • ISS 11MAR15
Page 2
2 Installation Guide
Content
Product overview 3 Camera description 5 Installation 8 Programming 11 Menu 13
Specifications 14 Legal and Regulatory information 15
Page 3
Installation Guide 3
Product overview
This is the Pocket Guide for TruVision High Definition TVI dome TVD-2401/TVD-4401 and TVD­2403/TVD-4403. This guide describes a standard installation.
Package contents:
Camera with power
and video output cables
3 screws and 3
anchors for wall or ceiling installation
Template
Installation Guide
Page 4
4 Installation Guide
WEEE and Battery Disposal
CD
Page 5
Installation Guide 5
Camera description
TVD-2401/TVD-4401
1. Base
2.
IR LED
3.
Lens
4. Dome liner
5. Housing
6.
Power supply
7.
TVI Video output cable (grey)
Page 6
6 Installation Guide
TVD-2403/TVD-4403
1. Base
2.
IR LED
3.
Lens
4.
Dome liner
5.
Housing
6.
Power supply
7.
TVI video output cable (grey)
8.
CVBS video output
cable (black)
Page 7
Installation Guide 7
Note:
Please check the camera output settings
before setting up a system. The TVI video output can be only connected to DVR with TVI signal input. The CVBS output supports
the standard monitor, test monitor, encoder and DVR.
For TVD-2403/TVD-4403, you can connect the white and black line ends of the WDR switch cable to enable the Wide Dynamic
Range function. The WDR function is disabled by default. If WDR is enabled, the CVBS output will be blocked out, and only
TVI output is available.
Page 8
8 Installation Guide
Installation
To install the camera on a ceiling:
1. Using the template, place it level against the mounting surface and mark the position of the mounting holes.
2. Following all local codes, drill and prepare the mounting holes.
3. Loosen the screws with wrech to remove the housing.
Drill Template
Hole A: for cables routed through the ceiling screw hole 1: for Mounting Base
1
1
1
A
Page 9
Installation Guide 9
4. Securely fasten the mounting base to the mounting surface with the screws.
5. Using a 75 ohm coaxial video cable, connect the camera TVI video output and a TVI DVR, and connect a 12 VDC power supply to the camera power cable.
Page 10
10 Installation Guide
6. Adjust the surveillance angle according to the figure below.
7. Re-attach the housing to the base.
Page 11
Installation Guide 11
Programming
Programming on TVI output:
Programming on TVI output is available for TVD­2403/TVD-4403 only.
Once the camera hardware has been installed, you can configure the camera settings on the TVI DVR.
Please select PTZ protocol as TruVision Coax and click menu button to call up the camera menu.
For more details, please see the TVI DVR user
manual.
TVI
Page 12
12 Installation Guide
Programming on CVBS output:
Programming on CVBS output is available for TVD­2403/TVD-4403 only.
Programming on CVBS output, you need to connect a monitor and a TVS-C200 controller (purchase separately) as following system figure.
The TVS-C200 has one male BNC output and a
female output. Please connect the male output to camera’s CVBS output and female output to a monitor.
TVI
CVBS
Page 13
Installation Guide 13
Menu
Page 14
14 Installation Guide
Specifications
Power supply
12 VDC
Current
TVD-2401/TVD-4401:
Max. 300 mA TVD-2403/TVD-4403: Max.333 mA
Power consumption
TVD-2401/TVD-4401:
Max. 3.5W TVD-2403/TVD-4403: Max. 4W
Weight
345 g (0.76 lb.)
Dimensions (Ø × L)
111 x 82 mm (4.4 x 3.2 in. )
Page 15
Installation Guide 15
Legal and Regulatory
information
Copyright:
© 2015 United Technologies Corporation,
Interlogix is part of UTC Building & Industrial Systems, a unit of
United Technologies Corporation. All rights reserved.
Trademarks and patents:
Trade names used in this document may be trademarks or
registered trademarks of the manufacturers or vendors of the respective products.
Manufacturer:
Interlogix 2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA
Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands
Certification:
N4131
FCC compliance: Class A
Class A: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is op
erated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause
Page 16
16 Installation Guide
harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ACMA compliance
Notice! This is a Class A product. In a domestic environment this
product may cause radio interference in which case the user may
be required to take adequate measures.
Canada
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme
NMB-0330 du Canada.
European Union directives:
12004/108/CE (EMC directive): Hereby, UTC Fire & Security declares
that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see:
www.recyclethis.info.
Contact information:
For contact information, see www.interlogix.com or www.utcfssecurityproducts.eu
Loading...