Fiber Optic
Data Transmitters and Receivers
Overview
The Enhanced Two-Way Multiprotocol data transceivers provide
two-way transmission of multiprotocol data over one or two fibers.
S711D models feature multimode operation, while S7711D models
operate over single mode fiber.
Data Translation
This equipment also features the unique data translation function
that allows input of one data format and output of a different
format. Data formats are selected during installation and can be
easily changed in the field via rotary switch.
Superior Diagnostics
The SMARTS™ diagnostic technology provides an extensive array
of system status LEDs. The integrity of the data paths can be tested
with a built-in data transmission test generator. It is not necessary
to connect to an external data device.
Enhanced
Standard Features
•
Two-way data transmission over one or two fibers
•
Single and multimode models available
•
Supports multiprotocol data formats including RS-232, TTL,
RS-422, RS-485, Manchester, Biphase, and SensorNet
•
Unique data translation function
•
User-configurable data format
•
18 dB optical budget
•
Optical AGC
•
SMARTS™ diagnostics
•
Standalone and rack configurations
Two-Way
Multiprotocol
Data
S711D and S7711D
Related Diagram
Data In/Out Data In/Out
Transceiver
Transceiver
Specifications
Data S711D (Multimode) S7711D (Single Mode)
Channels 1 duplex
Formats RS-232 (3-wire/5-wire), TTL, RS-422, RS-485 (2-wire/4-wire),
Baud Rate 250 kbps to 51 2 kbps (depending on data format)
Bit Error Rate <1.0E-9
Optical
Mode Multimode Single Mode
Optical Budget* 18 dB
Emitter LED or Laser Laser
Wavelength 850 nm and/or 1300 nm
(depending on model)
Operating Distance** Up to 15 mi (25 km)
(depending on model)
Transmitter Launch Power -10 dBm
Receiver Sensitivity -28 dBm
Gain Control Optical Automatic Gain Control (OAGC)
Electrical
Input Power 13.5 VDC regulated
Current Requirement 350 mA
Power Consumption 5 W
Power Factor 3
Protection Solid-state short circuit protection
Optional Power Supply Model 613P
Environmental
Operating Temperature -40 to 167 °F (-40 to 75 °C)
Maximum Humidity 95% relative, noncondensing
Mechanical
Dimensions (LWD, Standalone
Units)
Dimensions, Rack Units 1 slot (1.0”)
Weight Standalone 0.22 lbs (0.1 kg); Rack 0.55 lbs (0.25 kg)
Construction Polycarbonate (standalone); Aluminum (rack)
Manchester, Biphase, SensorNet
1310 nm and/or 1550 nm
(depending on model)
Up to 37 mi (60 km)
(depending on model)
5.0” x 2.8” x 1.5” (127 x 71 x 38 mm)
Optical Fiber
Ordering Information
Use the Configurators below to select the options available for these products.
* Optical Budget based on 62.5 µm fiber, for 50/125 µm fiber subtract 3 dB.