Interlogix Kalatel KA2 ProBridge Series, Kalatel CBR-PB2-KA2 Product Overview & Installation Manual

Calibur Kalatel KA2 ProBridge
Product Overview
& Installation Manual
Calibur Kalatel KA2 ProBridge 1 0150-0217B
Warning!
The lightning flash with the arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point, within an equilateral triangle, is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
!
Caution!
To prevent electric shock, do not remove cover. No user serviceable components inside. Refer servicing to qualified service personnel.
!
Caution! Electrostatic-Sensitive Device!
Use proper CMOS and MOSFET handing precautions, including approved grounded wrists straps, etc., to avoid damage to this unit or its internal components, from electric discharge.
Warning!
This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions in this manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to subpart J of part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment. This equipment has also been tested and found to comply with the requirements for a CE Class A device and TUV safety standards.
Operation of this equipment in a residential area may cause interference, in which case the user is required to take all measures that are necessary, at the user's expense, to correct the interference.
Copyright Information
Software and/or firmware is furnished to the purchaser under a license for use on a single system. Software and/or firmware included with this equipment are the sole proprietary property of, confidential to, and copyrighted by Kalatel, Corvallis, Oregon, USA. The software/firmware are not to be copied or disclosed in any manner without the express written consent of Kalatel.
All information and specifications furnished by Kalatel are believed to be accurate and reliable. No responsibility is assumed by Kalatel for neither its use nor any infringements of rights of third parties that may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Kalatel.
The CALIBUR brand name and product model numbers are the property of Kalatel. COPYRIGHT, 2002: The contents of this manual may not be copied or reproduced in any
manner or form without the prior written consent of Kalatel.
Calibur Kalatel KA2 ProBridge 2 0150-0217B
1 KA2 ProBridge ............................................................... 4
1.1 Kalatel KA2 ProBridge Description.....................................................4
1.2 Compatibility.....................................................................................4
1.3 Installation Environment ....................................................................4
1.4 Power...............................................................................................5
1.5 Installation Steps Summary...............................................................6
1.6 Connection Diagrams........................................................................7
2 Cable Specifications...................................................... 8
3 Troubleshooting............................................................. 9
4 Unit Settings ................................................................ 10
4.1 Configuring ProBridge Jumpers.......................................................10
5 Specifications .............................................................. 12
6 Appendix ...................................................................... 13
6.1 RS-485 Addressing and Connections ..............................................13
7 Using Calibur Keypads ................................................ 16
8 Warranty and Service .................................................. 17
8.1 Factory Service...............................................................................17
8.2 Warranty.........................................................................................17
Calibur Kalatel KA2 ProBridge 3 0150-0217B
1 KA2 ProBridge
1.1 Kalatel KA2 ProBridge Description
The Kalatel CBR-PB2-KA2 is a specific ProBridge unit for interfacing the DVMRe family of digital video multiplex/recorders to Kalatel PTZ Cyberdomes where local keyboard control is not already provided via a CBR-KB3 or KTD-405 keypad.
The CBR-PB2-KA2 combines into a single unit the services of both a CBR-PB2­KAL and a KTD-410 previously required for all Cyberdome installations. Due to all services being provided via a single unit this new configuration is less expensive and easier to install.
1.2 Compatibility
The CBR-PB2-KA2 is compatible with all Calibur by Kalatel systems equipped with RS-485 network capabilities except installations with a CBR-KB1 Keypad.
Compatible units include the Calibur DVMRe digital video units and various Calibur Multiplexer models. Please check the specifications of the particular Calibur product for RS-485 network support.
Kalatel Components:
(1) CBR-PB2-KA2 ProBridge. This product includes:
(1) CBR-PB2-KA2 ProBridge unit.
(1) P/N 4310-0034: RJ45 to RJ45 cable. Connects the ProBridge to
RS-485 Network. This cable is 6’ in length.
(1) P/N 4310-0032A Cable from PB2 to Receiver/Dome
(1) P/N 4010-0007: 12VDC 120VAC Power Supply or
(1) P/N 4010-0008: 12VDC 220VAC Power Supply.
(1) P/N 0150-0217A: Product Overview and Installation Manual.
1.3 Installation Environment
Power: Ensure that the installation site’s AC power is stable and within the rated voltage of the external power supply. If the site’s AC power is likely to have spikes or dips, use power line conditioning or an Uninterruptible Power Supply.
Temperature: Observe the unit’s ambient temperature specifications when choosing a location for the unit. Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail. Do not install this unit on top of other hot equipment.
Moisture: Do not expose the unit to rain or moisture. Moisture can damage internal components. Do not install this unit near sources of water.
RS485 Limitations: Total length of the RS-485 network is limited to 3000’.
Calibur Kalatel KA2 ProBridge 4 0150-0217B
1.4 Power
The ProBridge is furnished with a power supply (110 or 240 VAC). Do not use any other power supply with this product. The manufacturer accepts no responsibility for damage caused by the use of any other power supply.
Make sure installation is complete and all connections are made before applying power to the unit.
4310-0007 120VAC Power Supply
Power Supply Input
Voltage: 120 Volt AC Tolerance: ±10% Frequency: 60 Hz
Power Supply Output
Voltage: 12 Volt DC Current: 110mA Power: 1.3 Watts Connector: 2.1mm female barrel. Center Positive
4310-0008 220VAC Power Supply
Power Supply Input
Voltage: 220 Volt AC Tolerance: ±10% Frequency: 50 Hz
Power Supply Output
Voltage: 12 Volt DC Current: 110mA Power: 1.3 Watts Connector: 2.1mm female barrel. Center Positive
Calibur Kalatel KA2 ProBridge 5 0150-0217B
1.5 Installation Steps Summary
Carefully and completely read the manuals for each piece of equipment before attempting to install and connect this equipment.
Before you start connecting telemetry and other optional accessory equipment to your system, make sure that all, power, video, VCR, and monitor connections are completed, and everything is working correctly.
Wire the telemetry equipment according to that unit’s installation instruction. Use the internal diagnostic testing capabilities of the telemetry receiver to verify that the power and connections to the lens and motors are correct, and function properly.
Using the Diagram on the following page, connect the equipment in the following order:
1. Connect the CBR-PB2-KA2 to the Calibur unit (Multiplexer, DVMRe, Triplex) via RS-485 port using the RJ-45 to RJ-45 cable. The maximum total distance allowed on the RS-485 data line (without signal amplification or modems) is 3,000 feet (1,000 meters). A 100-ohm terminator is required at each end of the RS-485 line.
2. Supply power to the Calibur unit first and the CBR-PB2-KA2 second using the supplied AC to 12 VDC adapter. Via the Setup Menus for the Calibur unit set the RS-485 network address to the appropriate number (see the Appendix for RS-485 addressing).
3. Using the provided Cable connect from the ProBridge RCVR/DRVR port to the Kalatel PTZ Interface card provided with the Cyberdome. See the receiver's (PTZ) installation manual for more detailed wiring instructions.
4. Set the ID addresses for the Receivers and Domes according to the table later in this manual.
5. Via a networked connected PC with WaveReader software, connect to the DVMRe unit and confirm proper control and operation of the PTZ unit.
Calibur Kalatel KA2 ProBridge 6 0150-0217B
DVMRe Triplex
4310-0034B Cable
4310-0032A Cable
Kalatel CyberDome
Kalatel Interface
*
*
Verify connections for the
specific multiplexer used.
1.6 Connection Diagrams
This drawing depicts one Cyberdome connected via an RS485/422 network to a Calibur Triplex unit that provides remote PTZ control over Ethernet via WaveReader software.
Connector Card
MUX/DVMR RCVR/DVR
Kalatel KA2
ProBridge
If remote PTZ control over Ethernet is to be provided with DVMRe
NOTE
NOTE
Calibur Kalatel KA2 ProBridge 7 0150-0217B
Multiplexed Digital Recorder, one CBR-PB2-PTZ ProBridge unit is required in addition to the CBR-PB2-KA2 unit referenced within this document.
If remote PTZ control over Ethernet is to be provided with a DVMRe Triplex Digital Recording unit, only the CBR-PB2-KA2 ProBridge unit referenced in this document is required.
2 Cable Specifications
Pin 1: Orange/White
Flying
Leads
Connector
ProBridge to Calibur Unit Cable (RS-485)
Part Number : 4310-0034B Communication Type: RS-485 Connector Type: RJ-45 ,RJ-45 Cable Required: 5 Foot RJ-45 to RJ-45
Triplex RS485 Cable (Supplied). Connects ProBridge to Triplex.
RJ-45 Connector RJ-45 Connector
ProBridge Unit to Dome/PTZ Receiver (RS-485)
Part Number : 4310-0032A Cable Communication Type: RS-485 Connector Type: RJ45, Terminals Cable Required: 6 Foot RJ45 to Flying
Leads RS422 Cable (Supplied). Connects ProBridge to J-Box
Pin 8: Brown Pin 7: Brown/White Pin 6: Green Pin 5: Blue/White Pin 4: Blue Pin 3: Green/White Pin 2: Orange Pin 1: Orange/White
RJ-45 RJ45
Connector Connector
Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1
RJ-45
Do Not Connect
Do Not Connect
Black
Red
Pin 8: Brown Pin 7: Brown/White Pin 6: Green Pin 5: Blue/White Pin 4: Blue Pin 3: Green/White Pin 2: Orange
Calibur Kalatel KA2 ProBridge 8 0150-0217B
RJ-45 Connector Flying Leads
3 Troubleshooting
If you are unable to verify control of the PTZ camera, please do the following:
1. Check that each device is properly powered.
2. Check that all cables and cable connections are correct
3. If the interface still does not work correctly contact Tech Support.
Calibur Kalatel KA2 ProBridge 9 0150-0217B
4 Unit Settings
4.1 Configuring ProBridge Jumpers
The unit ships from the factory with the correct settings for most applications and should not require the installer to open the unit and change the jumper settings. However, for trouble shooting purposes we have included the default jumper settings.
Opening The ProBridge
Place the ProBridge unit face down. Using a small Phillips screwdriver, carefully remove the screws located near each corner of the unit. Once the screws have been removed, lift the cover to detach.
Identifying The Jumpers
With the cover removed, orient the unit as shown here. There are two sets of configurable jumpers. One set, located on the left side of the board, controls how the unit communicates (JP2, JP3, JP4 and JP5). The other set, located at the bottom of the board (P6, twelve pin header) determines specific configuration elements for equipment interfacing.
ProBridge Circuit Board
Calibur Kalatel KA2 ProBridge 10 0150-0217B
s Preset 01 on
Default Jumper Settings
The default jumper settings are listed below:
PIN # DEFAULT STATUS
JP2 RS485 Position JP3 RS485 Position JP4 RS485 Position
JP5 RS485 Position P6 Pin 1 Installed P6 Pin 2 Installed P6 Pin 3 Not Installed P6 Pin 4 Not Installed P6 Pin 5 Not Installed P6 Pin 6 Not Installed P6 Pin 7 Not Installed P6 Pin 8 Not Installed P6 Pin 9 Not Installed
P6 Pin 10 Not Installed P6 Pin 11 Not Installed P6 Pin 12 See Bulleted items
No Jumper Installed: Straight Preset Mapping, i.e. Preset 1 i
Dome.
Jumper Installed: Offset Preset Mapping, i.e. Preset1 is Preset 00 on Dome.
Calibur Kalatel KA2 ProBridge 11 0150-0217B
5 Specifications
Physical
Housing Plastic enclosure. Dimensions
(W x L x H) Nominal Weight 4.8 oz (136 g) Shipping Weight 1 lb (453 g) packaged, including
Color Light gray.
Temperature Relative Humidity 90%, non-condensing.
1.5 x 4.4 x 3.3 in. (38 x 112 x 84 mm)
the external AC power supply and manual.
Environmental
0 to 40 °C, operating.
Electrical
AC Power External AC power supply included. Voltage Range: 110 to 240 VAC + 10% Current: 200 mA DC Power DC jack, positive center. Power Supply Voltage: 12 VDC Current: 110 mA Power: 1.3 W
All specifications are subject to change without notice. Kalatel
NOTE
believes that all specifications are correct, however no liability is assumed for omissions or errors.
Calibur Kalatel KA2 ProBridge 12 0150-0217B
6 Appendix
6.1 RS-485 Addressing and Connections
The Kalatel ProBridge (CBR-PB2) is not an addressable device
NOTE
Each camera input, whether a fixed camera or a Pan/Tilt/Zoom (P/T/Z) unit, is connected to a Calibur unit input. The Calibur unit has an RS-485 network address, and so does the P/T/Z camera receiver. This address determines when the telemetry receiver responds to commands sent over the RS-485 data line. Consult the PTZ installation manual for specific instructions on setting these addresses.
NOTE
and requires no user settings. The device simply acts as an interpreter, translating the remote telemetry commands into a format useable by the P/T/Z controller.
The CBR-PB2-KA2 can be used in conjunction with multiple Calibur units, multiple Cyberdomes (or Receiver/Drivers) with one or more keypads controlling the domes and the Calibur units. Since the ProBridge unit is a terminated device, care should be used when using this unit in a mixed application. The ProBridge (CBR-PB2-KA2 must be on the end of the RS-485 line. Please contact Kalatel Technical Support for design assistance.
The Calibur addresses are set in the range from 1 to 512, as are camera numbers connected to the Calibur unit. The receiver’s address range is from 0 to
511. The setting of the telemetry receiver’s address can easily be determined using the following table:
Calibur Kalatel KA2 ProBridge 13 0150-0217B
Calibur Unit
Address
01 1-32 00-31 02 33-64 32-63 03 65-96 64-95 04 97-128 96-127 05 129-160 128-159 06 161-192 160-191 07 193-224 192-223 08 225-256 224-255
: : :
16 481-512 480-511
Camera Range
Receiver Address
Range
When more than eight Calibur units are installed, use the following formula:
Telemetry Receiver Address = 32 x (Multiplexer ID - 1) + Camera Number - 1
In other words, telemetry receiver units connected to the inputs of the first Calibur have addresses of 0 to 31. The receivers connected to the second Calibur have addresses of 32 to 63, and so forth.
The RS-485 network is a multi-drop wiring configuration of maximum length 3,000 feet (1000 meters). RJ-45 cable and RJ-45 connectors are used for most hookups (see the installation/connection diagram). Some equipment manufactured by Kalatel may use flying leads, terminal blocks, or other types of connections.
Most units have looping RS-485 network connectors. Either socket can be used. Do not use third-party RS-485 equipment without first consulting Kalatel Technical Support for information on compatibility with other Kalatel equipment.
RS-485 Wire Specification
#24 AWG, twisted pair with shield (2-wire). Less than 16 pF per foot, nominal. Less than 25 ohms per 100 foot, nominal. 2-wire: Belden 9842 4-wire: Belden 9844
Calibur Kalatel KA2 ProBridge 14 0150-0217B
CALIBUR UNIT RS485 ADDRESSES
1 2 3 4 5 6 7 16 1 0 32 64 96 128 160 192 480 2 1 33 65 97 129 161 193 481 3 2 34 66 98 130 162 194 482 4 3 35 67 99 131 163 195 483 5 4 36 68 100 132 164 196 484 6 5 37 69 101 133 165 197 485 7 6 38 70 102 134 166 198 486 8 7 39 71 103 135 167 199 487 9 8 40 72 104 136 168 200 488
10 9 41 73 105 137 169 201 489 11 10 42 74 106 138 170 202 490 12 11 43 75 107 139 171 203 491 13 12 44 76 108 140 172 204 492 14 13 45 77 109 141 173 205 493 15 14 46 78 110 142 174 206 494 16 15 47 79 111 143 175 207 495 17 16 48 80 112 144 176 208 496 18 17 49 81 113 145 177 209 497 19 18 50 82 114 146 178 210 498 20 19 51 83 115 147 179 211 499 21 20 52 84 116 148 180 212 500
CAMERA INPUT NUMBER ON CALIBUR UNIT
22 21 53 85 117 149 181 213 501 23 22 54 86 118 150 182 214 502 24 23 55 87 119 151 183 215 503 25 24 56 88 120 152 184 216 504 26 25 57 89 121 153 185 217 505 27 26 58 90 122 154 186 218 506 28 27 59 91 123 155 187 219 507 29 28 60 92 124 156 188 220 508 30 29 61 93 125 157 189 221 509 31 30 62 94 126 158 190 222 510 32 31 63 95 127 159 191 223 511
CyberDome Addressing
Camera Inputs 17-32 are not available on DVMRe and DVMRe
NOTE
Calibur Kalatel KA2 ProBridge 15 0150-0217B
Triplex units. Dome addresses, for those inputs are not useable.
Using Calibur Keypads
Keyboards (CBR-KB3/J and KTD-405) are typically used to provide initial configuration of the Kalatel PTZ unit for setting PTZ addresses and presets. Please refer to the installation manual for the respective keyboard for setup and use with Kalatel PTZ units.
In some specific cases keyboards may be used in conjunction with
NOTE
the CBR-PB2-KA2 units where multiple Calibur units are being controlled via one or more local Keyboard. Available keyboards are only involved when an RS-485 is configured with CBR-KB2/J, CBR-KB3/J and KTD-405 Keyboards. Please contact Technical Support for additional instructions concerning these special installations.
Calibur Kalatel KA2 ProBridge 16 0150-0217B
7 Warranty and Service
7.1 Factory Service
If the unit requires factory service, contact the dealer who supplied the unit to you for the correct procedures on returning the unit to the factory or the nearest factory service center.
If the dealer is not available, contact the manufacturer of the unit as detailed below and request a Return Material Authorization number (RMA). The unit’s serial number must be provided before an RMA number can be issued. Units returned to the factory for service must have freight and insurance prepaid, and must show the RMA number clearly on all shipping documents. The failure symptoms must be clearly described by the operator and enclosed with the unit together with a copy of the original supplier’s invoice. Failure to comply with these instructions will delay service of the unit, and may result in the unit not being accepted by the Repair Center.
Factory Address
Kalatel Attention: Repair Center 3197-C Airport Loop Drive Costa Mesa, CA 92626 United States of America Telephone: 800-343-3358 (7:00 AM to 4:30 PM, Pacific Time) In Oregon: 541-754-9133 Fax: 541-754-7162 (24 hours a day)
For warranty information, see the following page.
7.2 Warranty
Kalatel warrants all of its equipment for three years from the date of purchase. This warranty covers any defects in materials and workmanship. Equipment failures that are due to improper installation, modification, abuse, or acts of nature will not be covered by this warranty. The repair department will evaluate all equipment returned for repair to determine warranty coverage. The Tech Support Manager will resolve any questions that may arise during evaluation to make a final determination.
Note: The three-year warranty does not apply to the following produc ts:
MobileView® and the monitor CRT, which carry a 12-month warranty from the date of purchase.
The warranty specifically covers any defects in material and workmanship and does not cover equipment that has been abused, damaged, or modified.
For all warranty repairs, Kalatel will cover all costs, including parts, labor, and shipping. Repaired equipment will be returned via the same method of shipment in which it was received. If a customer requests a faster return shipment, the difference will be charged.
For all non-warranty repairs, the customer will be billed for parts, labor, and shipping. Labor will be billed in half-hour increments.
Calibur Kalatel KA2 ProBridge 17 0150-0217B
Note: Customers requesting an estimate prior to repair will be notified by phone. If they cannot be reached, they will be notified by fax. If we are unable to reach the contact person for repair authorization after one phone attempt and two fax attempts, the equipment will be returned without being repaired. We will hold equipment no longer than two weeks.
Advance Replacement Policy
When an advance replacement is required, we will send the customer replacement equipment from our stock and receive the returned product in exchange. The received equipment will be evaluated and the repair department will determine whether it is a warranty replacement. If it is non-warranty, see our repair policy above for details. The following guidelines will be used for all advance replacements:
Fewer than 45 days from purchase, Kalatel will replace the product with new equipment.
From 45 days to 1 year from purchase, Kalatel will replace the product with refurbished equipment.
From 1 year to 3 years from purchase, the product must be sent in for repair. Advance replacements will be sent for a fee of $100.
If you have questions about this policy, please contact Kalatel’s RMA Department at 800-469-1676.