GE-DS-82 and GE-DS-82PoE Managed Switch
Installation Sheet
Package Contents
Thank you for purchasing the Interlogix 8-Port Fast Ethernet + 2-Port Gigabit
TP/SFP Combo Managed PoE Switch.
The following Managed Switch model numbers are covered in this sheet:
• GE-DS-82
• GE-DS-82-PoE
Open the b
contain the following items:
• The Managed Switch x1
• User manual CD x1
• This Installation Sheet x1
• RS-232 cable x1
• Rubber feet x 4
• Two rack-mounting brackets with attachment screws x1
• Power Cord x1
If any item is found missing or damaged, please contact your local reseller
for replacement.
© 2010 UTC Fire & Security.
All rights reserved.
P/N 1069669-EN • REV 1.01 •
ISS 19AUG10 1 of 11
ox of the Managed Switch and carefully unpack it. The box should
System Requirements
Your switch is designed to operate with a variety of platforms, operating
systems and network cards. Actual performance will depend on a
combination of these components. Differences in performance can occur
depending on the versions and types of platforms, operating system and
network cards used.
The minimum system requirements are:
• Clients running Windows 98/ME, NT4.0, 2000/XP, Vista, MAC OS9 or
later, Linux, UNIX or other platform compatible with TCP/IP protocols.
• Workstation installed with an Ethernet NIC (Network interface Card)
• Serial Port connection (Terminal)
• Above PC with COM Port (DB-9)
• Ethernet Port connection
• Network cables - Use standard network (UTP) cables with RJ45
connectors.
• Above PC installed with WEB Browser and JAVA runtime
environment Plug-in
Note: We recommend using Windows XP or Windows 7 with Internet
Explorer 6.0 or above for access to the switch management setup.
2 of 11 P/N 1069669-EN • REV 1.01 • ISS 19AUG10
Terminal Setup
There are three ways to access and setup your switch. They are:
• RS-232 console
• Telnet
• Web Browser
RS-232 console
To configure the system, connect a serial cable to a COM port on a PC or
notebook computer and to the serial (console) port of the GE-DS-82
Managed Switch. The console port of the Managed Switch is DCE already,
so that you can connect the console port directly through PC without the
need of Null Modem.
Figure 1: Terminal setup diagram
PC / Workstation with terminal
emulation software
Serial port Serial port 115200,8,n,1
Managed switch
A terminal program is required to make the software connection to the GEDS-82 and the GE-DS-82-PoE Managed Switch. Window’s Hyper Terminal
program is a good choice. The Hyper Terminal program can be accessed
from the Start menu.
1. Click START, then Programs/ Accessories and then Hyper Terminal.
2. When the COM1 Properties window appears, configure the COM port
with the following parameters and then click the OK button.
• Baud : 57600
• Parity : None
• Data bits : 8
• Stop bits : 1
• Flow Control : None
P/N 1069669-EN • REV 1.01 • ISS 19AUG10 3 of 11
2: The COM1 properties window
Figure
Logon to the Console
Once the terminal has connected to the device, Supply power to the GE-DS82 and the GE-DS-82-PoE Managed Switch, the terminal will display that it is
running testing procedures.
The following message asks for the login username and password. The
factory default password for the login screen is:
• Username: admin
• Password: admin
4 of 11 P/N 1069669-EN • REV 1.01 • ISS 19AUG10