Interlogix DE7200 User Manual

DE7100-EE
DE7200-M DE7100-ME DE7100-SE DE7100-MM DE7100-MS DE7100-SS
DE7200-S
DE7200-MM
DE7200-SS
DE7200-MS
IFS EtherNav Installation & Operation Instructions
P/N 1062843 • REV B • ISS 01AUG11
10 / 100
MIDI Switch Off
(All Electrical Ports)
10 / 100
MIDI Switch On
(All Electrical Ports)
LOSS OF SIGNAL
Transmit + (Pin 1) Transmit - (Pin 2)
Receive + (Pin 3) Receive - (Pin 6)
NOTE: Pins 4, 5, 7, 8 are not used.
Receive + (Pin 1) Receive - (Pin 2)
Transmit + (Pin 3) Transmit - (Pin 6)
NOTE: Pins 4, 5, 7, 8 are not used.
On LOS A
Off LOS A
Fiber Port A
LOSS OF SIGNAL
Fiber Port B
FIBER LINK
CONTA
CTS
(All Optical Ports)
CONTACT CLOSURE
FOR LOS
On LOS B
CONTACT CLOSURE
FOR LOS
3
2
1
NO
CONTA
CT CLOSURE
Off LOS B
NO
CONTA
Normal Open
COM
Normal Closed
CT CLOSURE
DE7100 SERIES
D
A
H
E
F
ACFiber port A
Fiber port B
B
C
B
C
I
D
G
Link Speed (Channels A&B)
D
Simplex/Duplex (Channels A&B) Power connection
E
Power
F
LOS A&B switch MDI On/Off
G
Fiber link contacts connection
H
I
Port connection
GRN = 100 RED or OFF = 10
GRN or YEL = DUPLEX OFF = SIMPLEX
LED illuminates with fiber connection
DE7200-M
OPTICAL ETHERNET
MEDIA CONVERTER
10/100TX
10/100TX
Multimode fiber optic cable
LNK ACT
TX
100FX
RX
TX
A
100FX
RX
LNK ACT
International
Fiber
ifs
DE7100-MS
3 PORT ETHERNET SWITCH
Systems
Incorporated
CONTACT CLOSURE
MDI - 3
LOS B - 1
POWER
CONTACT CLOSURE
NC - 2
NO - 3
COM - 2
NC - 1
OFF
POWER
+ 12 VDC - 1
10/100TX
NO - 3
COM - 2
NC - 1
- 2
10/100TX
Singlemode fiber optic cable
TX
B
100FX
RX
LNK ACT
TX
100FX
RX
International
Fiber
ifs
OPTICAL ETHERNET
MEDIA CONVERTER
ifs
Systems
Incorporated
DE7200-S
International
Fiber
Systems
Incorporated
MDI - 3 LOS A - 2 LOS B - 1
POWER
CONTACT CLOSURE
MDI - 3
LOS B - 1
POWER
NC - 2
OFF
POWER
+ 12 VDC - 1
10/100TX
NO - 3
COM - 2
NC - 1
OFF
POWER
+ 12 VDC - 1
- 2
10/100TX
- 2
IF YOUR POWER OUTLET DOES NOT HAVE A CONNECTION TO GROUND:
For proper installation the DE7100-XX stand alone units must be attached to earth ground. Ordinarily, this is accomplished through the power supply. If your power outlet does not have a ground prong then a wire must be attached from the power connector to ground. Connect the green wire included, from ground to the power connector as shown below.
GREEN WIRE
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation.
Changes or modifications not expressly approved by International Fiber Systems, Inc. could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to cor­rect the
interference at his own expense.
CLASS 1 LASER PRODUCT
(For purposes of IEC 60825-1)
Complies with FDA Performance Standard for Laser Products
Title 21
Code of Federal Regulations
Subchapter J
Comprehensive Lifetime Warranty
(a) Seller warrants to the original End User that products and any services furnished hereunder will be free from defects in material and workmanship as of the date of delivery, and will conform to Seller’s published technical specications. The foregoing shall apply only to failures to meet said warranties which appear within that period of time during which the Products are installed in their original installation for the original End User and operator of such Products; provided, however, that in the event of product discontin­uance, warranty support is limited to ve (5) years from the announcement of discontinuance. Notwithstanding the preceding sentence, the duration of the warranty period for manufactured by Seller (e.g., ber optic cabling, test equipment, power supplies or batteries) shall be the warranty period oered by the original manufacturer, if any.
(b) The conditions of any tests shall be mutually agreed upon and Seller shall be notied of, and may be represented at, all tests that may be made. The warranties and remedies set forth herein are conditioned upon (a) proper storage, installation, use and mainte­nance, and conformance with Seller and (b) Buyer promptly notifying Seller of any defects and, if required, promptly making the product available for correction.
(c) If any product or service fails to meet the foregoing warranties, Seller shall thereupon correct any such failure either at its option,
any applicable recommendations of
products not
(i) by repairing any defective or damaged product or parts of the products, or (ii) by making available any necessary repaired or replacement products or parts thereof. Any repaired or replacement part or product shall be warranted for the remaining period of the original Warranty Period. Seller shall pay, or credit Buyer for, the cost of freight for all return shipments of products or parts to Buyer. Where a failure cannot be corrected by Seller's reasonable eorts, the parties will negotiate an equitable adjustment in price.
(d) The preceding paragraph sets forth the exclusive remedies for claims based on defect in or failure of products or services, whether the claim is in contract, indemnity, warranty, tort (including Seller's negligence), strict liability or otherwise and however instituted. Upon the expiration of the warranty period,
liability shall terminate and BUYER shall have a reason-
all such able time, within thirty days after the warranty period, to give written notice of any defects which appeared during the warranty period. The foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, implied or statutory. NO IMPLIED OR STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. Seller does not warrant any products or services of others which BUYER has designated.
Contacting us
For help installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, contact us during business hours (Monday through Friday, excluding holidays, between 5 a.m. and 5 p.m. Pacific Time).
Sales and support contact information
North America
Toll-free: 855.286.8889 in the US, including Alaska and Hawaii; Puerto Rico; Canada.
Outside the toll-free area: 503.885.5700.
E-mail: techsupport@interlogix.com
Europe
Australia
Select Contact Us at www.utcfssecurityproducts.eu
security.tech.support@interlogix.com.au
Note: Be ready at the equipment before calling.
Online
Another great resource for assistance with your Interlogix product is our online publication library. To access the library, go to our website at the following location:
http://www.interlogix.com/transmission
1
1. Many Interlogix documents are provided as PDFs (portable document format). To read these documents, you will need Adobe Reader, which can be downloaded free from Adobe’s website at www.adobe.com.
Product Disassembly Instructions for WEEE
Per European Directive 2002/95/EC Waste Electrical and
Electronic Equipment
Required Tools:
One number 2 Phillips (crosstip) screwdriver. One number 2 flat screwdriver.
For the enclosed box version:
1. Locate and remove box cover securement screws. Usually, but not limited to, at least 4 screws.
2. Lift off box top cover.
3. Locate and remove securement screws for printed circuit board.
4. If there are multiple boards to the assembly, continue removing securement screws until none are left.
5. Lift off printed circuit board.
6. Disassembly of box version of product is complete.
Copyright © 2011 UTC Fire & Security. All rights reserved.
r
Trademarks and
patents
Manufacture
Certification
ACMA compliance Notice! This
Canada This Class A digital apparatus complies with Canadian ICES-003.
European Union
directives
Interlogix and IFS names and logos are trademarks of
UTC Fire & Security. Other trade names used in this document may be trademarks or
registered trademarks of the manufacturers or vendors of the respective products.
UTC Fire & Security Americas Corporation, Inc.
2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA Authorized EU manufacturing representative:
UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands
N4131
product may cause radio interference in which case the user may be required to take adequate measures.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
2004/108/EC (EMC directive): Hereby, UTC Fire & Security
decla
res that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC.
is a Class A product. In a domestic environment this
Canada.
2002/96/EC (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info.
Contact information For contact information, see www.interlogix.com.
Loading...