Interlogix AV-TS7 Installation

Advisor TouchScreen Installation Sheet
EN
CNF
PR
Figure 1. Advisor TouchScreen
Figure 2. Connecting the Ethernet Cable from Advisor Panel to Advisor TouchScreen
Figure 3. Connecting the Power Supply
Figure 4. Wall Mount Bracket
`
Figure 5. Tabletop Stand Installation
With End User Quick Guide Tear-Out Sheet
P/N 466-4414 • REV E 18NOV15 1 / 8
English: Installation Sheet
Description
The Advisor™ family of life-safety protection and comfort management systems detects situations and provides control and information to home and small business owners.
This document provides instructions on installing and programming the Advisor TouchScreen 7” (P/N AV-TS7) for use with an AdvisorOne panel. Note: Contact Interlogix Technical Support for other Advisor panels.
The Advisor TouchScreen extends the control and accessibility of an Advisor panel. Up to 32 (subject to change) Advisor TouchScreens can be used in an installation. When a TouchScreen is enrolled with an Advisor panel, the TouchScreen can control the system, including the panel and other TouchScreens.
Preparation and Installation
The installation procedure is a two-part process. First, the Advisor TouchScreen is enrolled into the panel via a temporary CAT5 cable connection at the Advisor panel. When enrolled, the Advisor TouchScreen is disconnected, moved, and mounted into its permanent location, and its communication re-established.
Temporarily Connecting/Enrollment of the Advisor TouchScreen to the Advisor Panel
1. Do not remove the film cover from the touch screen until installation is complete.
2. Temporarily place the Advisor TouchScreen (A in Figure 1) close to the Advisor panel (B in Figure 2).
3. Locate the LAN port (C in Figure 2) on the Advisor panel and plug the provided CAT5 cable (D in Figure 2) into it.
4. Locate the Ethernet LAN port on the Advisor TouchScreen and plug the other end of the CAT5 cable (E in Figure 2) into it.
5. Configure the power supply by connecting the end of the supplied wire that has a dashed marking to the + terminal on the DC
output of the power supply (F, G in Figure 3). Connect the other wire that has no marking to the - terminal on the DC output.
Note: It is important that polarity is observed. Ensure consistency by wiring + to + and - to -. Failure to observe polarity may result in damage.
6. Connect the power supply plug to the power jack into the Advisor TouchScreen (H, I, and J in Figure 3). Plug in the power supply.
7. With power supplied, the Advisor TouchScreen will display a screen similar to the one shown (Note: The exact screen content may be different). If no screen appears, refer to Troubleshooting on page 4.
Note: Learning procedures vary by Advisor panel type. Follow the instructions for the specific panel the TouchScreen is being enrolled with.
For Enrollment with an AdvisorOne Panel:
8. On the AdvisorOne panel, press the Settings icon on the lower left of the main screen. 8-1. On the AdvisorOne panel, press CONFIGURATION to enter programming. 8-2. Enter the Installer or dealer access code. 8-3. From the Configuration & Programming screen, press DEVICES. 8-4. From the Devices screen, press EDIT next to IP Devices. 8-5. From the IP Devices screen, press LEARN to initiate TouchScreen learning.
Note: It takes from 15 - 60 seconds to detect and configure the TouchScreen.
8-6. Press EDIT next to the name of the TouchScreen. The default name is Wireless Touch Screen.
2 / 8 Advisor Touchscreen Installation Sheet
8-7. Optionally edit any of the following on the TouchScreen Properties screen:
Option
Description
Name
Press the field next to Name to enter the desired name for the TouchScreen. Press DONE to save the name.
CAR
Code Access Required. When enabled, a passcode is required for any access. In less secure areas, like a garage, enable this setting. For more secure areas, this setting can be disabled.
Partitions
Press the icon next to Partitions to edit the partitions that can access this TouchScreen.
Installation
Action
Note
US
1. On the new power supply, knock out the screw hole in the securement tab.
2. Plug the power supply into the outlet and secure with the supplied screw.
Canada
Plug the power supply into the outlet.
Do not use the securement tab and screw.
All Other Installations
Follow regional requirements.
8-8. Press SAVE to save the settings. 8-9. If successful, proceed to the mounting stage. If the TouchScreen configuration is unsuccessful, the Failed to add device
message will display. Reset the TouchScreen and refer to Troubleshooting on page 4.
For Enrollement in other Advisor Panels: Contact Interlogix Technical Support.
Moving the TouchScreen to its Permanent Mounting Location
9. Remove power from the Advisor TouchScreen and disconnect the CAT5 Ethernet cable from the Advisor panel and the Advisor TouchScreen.
10. Move the Advisor TouchScreen to its permanent mounting location, taking into account the following:
Place the Advisor TouchScreen in a frequently used area, such as a hallway or entryway.
Place the Advisor TouchScreen within reach of a power outlet or PoE switch (Power over Ethernet). The Advisor TouchScreen may be powered using the 8-foot power cord, a 25-foot power cord (not included), or power over Ethernet (PoE).
Place the Advisor TouchScreen so that the wired/wireless communication can be established. For wired installations using
CAT5 Ethernet cable, place the Advisor TouchScreen within 295 feet of the Advisor panel (maximum). For WiFi, place the Advisor TouchScreen within approximately 100 feet of the Advisor panel.
11 Mount the Advisor TouchScreen.
For Mounting on a Wall with the Mounting Bracket:
11-1. Run all necessary power and Ethernet connections to the desired TouchScreen location. Before drilling holes, be
aware of any electrical wiring at the location. 11-2. Hold the bracket against the wall and mark the four mounting hole locations with a pencil (K in Figure 4). 11-3. Drill the four mounting holes. Insert the provided drywall anchors if no studs are present. Note: Use a Ø 1/8” pilot hole for the screw going into the wall stud. Use a Ø 3/16” pilot hole for the wall anchor. 11-4. Secure the mounting bracket using the four mounting screws (provided) to the four mounting locations on the wall
marked in step 12-3. Do not tighten the screws at this time. 11-5. Level the mounting bracket and secure the four mounting screws. 11-6. Connect the power plug and Ethernet CAT5 (if used) to the TouchScreen. If outside the wall, route through channel. 11-7. Attach the Advisor TouchScreen to the mounting bracket that is secured to the wall, making sure the tabs on the
mounting bracket engage the holes on the Advisor TouchScreen. Ensure that the TouchScreen is secure. 11-8. Supply permanent power to the Advisor TouchScreen as noted in the table below.
Advisor Touchscreen Installation Sheet 3 / 8
Loading...
+ 5 hidden pages