GE
Fiber Optic
Security
Overview
The 515PS1 Internal Rack Power Supply is designed to provide
power to a 517R1 Card Cage Rack. The unit provides a single 13.5
VDC output operating at 6 amps. The power supply accepts an AC
input voltage from 100 to 240 VAC, 60/50 Hz. A second power supply can be installed in the 515R1 Rack to provide redundancy.
Alarm Features
A fiber-fail alarm is built into the 515PS1 power supply and is functional when the card cage rack is populated with receiver cards. The
alarm activates when the optical signal input to any receiver card
is lost. The alarm activates a buzzer built into the unit, illuminates
a front panel LED, and relay contacts with connections on the back
panel. The relay output can be connected to a remote device such
as a lamp or buzzer, relay contacts are normally open (NO) dry
contacts.
Front Panel Controls and Indicators
The 515PS1 front panel contains DC power and Alarm LED indicators as well a a MUTE switch. The MUTE switch is used to disable the
fiber-fail alarm.
Accessories
Power Supply Redundancy
The 515PS1 Internal Rack Power Supply is supplied with the 515R1
Card Cage Rack. If power redundancy is required, a second 515PS1
can be installed in the card cage rack. If the primary unit fails, switchover to the redundant power supply is automatic.
Standard Features
•
110 to 240 VAC, 60/50 Hz input
•
13.5 VDC output at 6 amps (Power Factor 48)
•
Supplied with 515R1 Card Cage Rack
•
Can be provided as redundant supply with automatic switchover
•
Fiber fail and power fail alarms
•
Front panel indicator and MUTE switch
•
Dry contact or 14 VDC alarm output
•
AC power cord supplied
Internal Rack
Power Supply
515PS1
GE
Security
U.S.
T (561) 998-6100
T 888-GE-SECURITY
888-(437-3287)
F 561 998 6224
Canada
T 519 376 2430
F 519 376 7258
Asia
T 852-2907-8108
F 852-2142-5063
Australia
T 61-3-9239-1200
F 61-3-9239-1299
Europe
T 44-113-238-1668
F 44-113-253-8121
Latin America
T 305-593-4301
F 305-593-4300
www.gesecurity.com
© 2005 General Electric Company
All Rights Reserved
Specifications
Electrical
Input Voltage 100 to 240 VAC, 60/50 Hz
Input Current 0.99 A @ 115 VAC; 0.49 A @ 230 VAC
Power Consumption 113 VA @ 115 VAC
Power Dissipation 28 W @ 115 VAC
Output Voltage 13.5 VDC
Output Current 6 A
Power Factor 48
Fuse Rating 2.0 A, 250 V, slow-blow
Fuse Size 5 x 20 mm, located in pull-out tray on back panel
Connectors
Power Input Recessed IEC 320 3-pin male (cable supplied)
Alarm Output 5-pin detachable screw terminal
Mechanical
Length 9.9” (251 mm)
Width 2.0” (51 mm)
Height 5.25” (133 mm)
Weight 1.9 lbs (0.87 kg)
Construction Aluminum
Finish Black semigloss paint
Mounting Two captive screws
Environmental
Operating Temperature -40 to 167 °F (-40 to 75 °C)
Maximum Humidity 95% relative, noncondensing
Related Diagram
Ordering Information
Use the model number below when ordering this product.
As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications, visit GESecurity online at www.GESecurity.com or contact your GE Security sales representative.
515PS1-2006-09-2