Interlogix 1078CT User Manual

1078CT Series
Magnetic Contacts
3/4" Diameter Steel Door
Gap distance Closed loop
In Steel In Wood
3/8" 7/8" 1078CT 3/4" 2" 1078CTW 5/8" R1078CT
Color
Quantity
White Mahogany Grey
brown
10
U
¤
L
C
US
LISTED
0
4618807027
5
1078CT Series 3/4" Diameter Steel Door with Terminals
0.89"
2.26 cm
1.63"
4.13 cm
1.81"
4.60 cm
0.63"
1.59 cm
0.50"
1.27 cm
Magnet
Part No. 1840
(included)
Magnetic Contacts Installation Instructions
For 1078CT
1. Drill 3/4" diameter and 1 5/8" deep holes for contacts and 3/4" diameter and 1 1/2" deep holes for magnets. Hole saw arbors available from Sentrol.
2. Strip wire from security system loop, insert into terminal block and tighten. T est for continuity .
3. Lightly coat the contact and magnet with RTV mounting compound (Sentrol part number
1905) and insert into respective holes.
1078CT
1.63"
4.13 cm
0.94"
2.36 cm
1.56"
3.96 cm
Magnet
Part No. 1929
(included)
0.38"
0.95 cm
1.91 cm
0.75"
For R1078CT
1. Drill 3/4" diameter and 1 5/8" deep hole for contact. The 1840 Magnet is designed to be mounted in the top channel of a metal entry/exit
R1078CT
1.63"
4.13 cm
door. The magnet can be rot ated to accommodate either wide or narrow top channels.
2. Clean top channel of door.
0.94"
2.36 cm
3. Position magnet opposite switch in top of door channel.
4. Lightly coat the contact and magnet with RTV mounting compound (Sentrol par number 1905) and mount into respective locations.
UL Specifications **European Union Specifications: 48 VAC/DC Max., 0.5 Amp
Part Loop Electrical Gap Distance
Number Type Configuration In Wood In Steel
1078CT Closed N.O. 7/8" 3/8"
1078CTW Closed N.O. 2" 3/4"
R1078CT Closed N.O. N/A 5/8"
**FORM A (1078CT , 1078CTW, R1078CT)
Vol tage: 100 V AC/DC Max Current: 0.5 A Max Power: 7.5 W Max
*Gap Specifications are nominal and may vary
±20% due to temperature. Gap Specifications
are for switch to make. Break distance is approximately 1.1 to 1.5 times make.
ULC Specifications
All Contact s: 30 VDC, 50 ma max. Gap Specifications:*
See UL Gap Specifications
13960 Rev C 11/01
Loading...