Interacter ICS 12/25A, ICS 24/25A, ICS 36/20A, ICS 48/20A, PS 12/5, PS 12/10, PS 24/5, PS 24/8, LS 6/6, LS 12/2, LS 12/6, LS 24/3, LS 24/5, LS 36/3, LS 48/5, EX 24/3 Owner's Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
BATTERY CHARGER
OWNER'S MANUAL
INTERACTER
II MODELS
PROFESSIONAL, LINEAGE, EX and INDUSTRIAL/ COMMERCIAL SERIES
6, 8, 12, 16, 24,36 and 48 Volt
---- CAUTION ----
READ THIS MANUAL CAREFULLY FOR
RULES OF SAFE OPERATION AND
PROPER USE OF THE CHARGER
*** SAVE THESE INSTRUCTIONS ***
IMPORTANT SAFETY INSTRUCTIONS
Interacter offers a range of high performance Battery Chargers fo ruse in demanding applications, featuring a
patented
The
models provides fast charging and optimal timing over a wide range of battery sizes and depths of discharge.
microprocessor system that out-performs all industry standard chargers in the same price range.
THREE STAGE Constant Current, Constant Voltage, Proportionally timed system used in all Interacter
STANDARD FEATURES OF ALL INTERACTER CHARGERS:
HIGH ENERGY RETURN, FAST CHARGING
CONSTANT CURRENT FIRST STAGE
DUAL VOLTAGE LIMIT (CYCLIC/ STANDBY)
PROPORTIONAL TIMED CYCLIC CHARGE STAGE
CONSTANT VOLTAGE FLOAT STANDBY
AUTOMATIC SAFETY OVERRIDE TIMER
START DELAY ON BATTERY CONNECT
SHORT AND REVERSE CONNECTION SHUTDOWN
RUGGED SCR PHASE CONTROL
MAINS ZERO-CROSSING BATTERY SENSING
LINEAGE SERIES (LS) MODELS are the most cost effective series and are available for 6, 12, 24, 36, and 48 volt batteries
rated at up to 6 amps.
EX SERIES (EX) Utilizes the LS controls in a more compact and wall mountable package.
PROFESSIONAL SERIES (PS) MODELS are available for 12 and 24 volt batteries, rated at up to 10 Amps. In addition to the
above features, they include Temperature Compensation, an LED Ladder Amp Meter, an 80% charging indicator and an
internal preset “Battery Type” switch allowing the unit to be easily configured for use with Gel Cell, Sealed Lead Acid or
Liquid Electrolyte batteries.
INDUSTRIAL/ COMMERCIAL SERIES (ICS) MODELS are heavy duty chargers available for 12,24,36, or 48 volt batteries
ratedat up to 25 Amps. The ICS models provide all the same features as the PS models together with higher current ratings.
INDUSTRIAL/ COMMERCIAL SERIES
12,24,36,& 48 VOLT
SPECIFICATIONS
PROFESSIONAL SERIES
12 & 24 VOLT
SPECIFICATIONS
MODEL ICS 12/25A
INPUT: 117 Volts AC 60Hz, 480 VA
OUTPUT: 12 Volts DC, 25 Amps
MODEL ICS 24/25A
INPUT: 117 Volts AC 60Hz, 900 VA
OUTPUT: 24 Volts DC, 25 Amps
MODEL ICS 36/20A
INPUT: 117 Volts AC 60Hz, 1120 VA
OUTPUT: 36 Volts DC, 20 Amps
MODEL ICS 48/20A
INPUT: 117 Volts AC 60Hz, 1500 VA
OUTPUT: 48 Volts DC, 20 Amps
Optional Export AC Input Ratings
100v-50Hz AC Input (Japan)
115/ 230v -50Hz AC Input (Europe) (CE)
Full Wave Phase Controlled Rectification
CONTROL:
Voltage limit:
Normal Mode 2.42 V/Cell
Gel-Cell Mode 2.33 V/Cell
Liquid Electrolyte Mode 2.62 V/Cell
Current limited to AMP rating MEAN DC.
Automatic timer starts when first stage voltage
limit reached. Proportional CV stage
timer - t/2+1 hour.
Constant voltage 2.3 V/Cell after timeout, with
Temperature Compenation.
PROTECTION:
Electronic reverse polarity. Short circuit shutdown
and current limit.
Combined Circuit Breaker and power switch on
front panel.
BATTERY TYPE & RATING (See Page 11 BTS)
ICS chargersare for use with Lead Acid Batteries of
Minimum capacity 50 AH, Gel Cell, Absorbed
Electrolyte or Liquid Electrolyte types by using the
BTS (Battery Type Switch)
DIMENSIONS: (Inches)
12.0 " WIDE, 7.0" FRONT TO BACK, 7.0" HIGH
CONFORMS
TO
U.L. 1236
MODEL PS 12/5
INPUT: 117 Volts AC 60Hz, 110 VA
OUTPUT: 5 Amps DC 12 Volts
MODEL PS 12/10
INPUT: 117 Volts AC 60Hz, 220 VA
OUTPUT: 10 Amps DC 12 Volts
MODEL PS 24/5
INPUT: 117 Volts AC 60Hz, 200 VA
OUTPUT: 5 Amps DC 24 Volts
MODEL PS 24/8
INPUT: 117 Volts AC 60Hz, 320 VA
OUTPUT: 8 Amps DC 24 Volts
Optional Export AC Input Ratings
100v-50Hz AC Input (Japan)
115/ 230v -50Hz AC Input (Europe)
Full Wave Phase Controlled Rectification
CONTROL:
Voltage limit:
Normal Mode 2.42 V/Cell
Gel-Cell Mode 2.33 V/Cell
Liquid Electrolyte Mode 2.62 V/Cell
Current limited to AMP rating MEAN DC.
Automatic timer starts when first stage voltage limit
reached. Proportional CV stage timer - t/2+1 hour.
Constant voltage 2.3 V/Cell after timeout, with
Temperature Compensation.
PROTECTION:
Electronic reverse polarity. Short circuit
shutdown.
and current limit.
AC Input fuse in AC Input connector
BATTERY TYPE & RATING (See Page 11 BTS)
PS chargers are for use with Lead Acid Batteries, Gel
Cell Absorbed Electrolyte or Liquid Electrolyte types by
using the BTS (Battery Type Switch)
DIMENSIONS: (Inches)
6.5" WIDE, 6.0" FRONT TO BACK, 5.25" HIGH
2
LINEAGE and EX SERIES
SPECIFICATIONS
MODEL: LS 6/6, LS 12/2, LS 12/6, LS 24/3
LS 24/5, LS 36/3, LS 48/5, EX 24/3
Full Wave Phase Controlled Rectification
IMPORTANT SAFETY
INSTRUCTIONS
1. IMPORTANT SAVE THESE INSTRUCTIONS-- This
manual contains important safety and operating
instructions for all INTERACTER battery chargers.
CONTROL:
Voltage limited to 2.4 Volts/Cell
Current limited to AMP rating Mean D.C.
Finish voltage 2.3 Volts/Cell
Proportional Timed Cyclic Charge Stage
Flashing Yellow LED-to Show 80% State of
Charge
PROTECTION:
Electronic reverse polarity
Short circuit shutdown
Low voltage start
Optional: Temperature compensation
DIMENSIONS: Lineage Series
6.5" WIDE, 6.0" FRONT TO BACK, 5.25" HIGH
DIMENSIONS: EX Series
3.5 WIDE, 3.25 FRONT TO BACK, 6.0 HIGH
LISTED
CONFORMS TO
U.L. 1236
2. Before using this battery charger, read all
instructions and cautionary markings on (1) the battery
charger, (2) the battery, (3) product using the battery.
3.CAUTION--To reduce risk of injury, charge only lead
acid, maintenance free or flooded lead acid type
rechargable batteries. Other types of batteries may
burst causing personal injury and damage.
4. Do not expose charger to rain or snow.
5. Use of an attachment not recommended or sold by
the battery charger manufacturer may result in a risk of
fire, electric shock or injury to person.
6. To reduce risk of damage to electric plug and cord,
pull by plug rather than cord when disconnecting
charger.
7. Make sure cord is located so that it will not be
stepped on, tripped over or otherwise subjected to
damage or stress.
8. An extension cord should not be used unless
absolutely necessary. Use of improper extension cord
could result in risk of fire and electrical shock. If an
extension cord must be used, make sure:
a.That pins on plug of the extension cord are the
same number, size and shape as those of the
plug on the charger.
b. That the extension cord is properly wired
3
c. That the wire size is large enough for the A/C ampere
rating of the charger as specified in the table below:
LENGTH OF CORD (feet)
AWG Wire Size
9. Do not operate charger with damaged cord or plug.
REPLACE THEM IMMEDIATELY.
2550100150
1818 16 14
PERSONAL PRECAUTIONS
1. Someone should be within range of your voice or
close enough to come to your aid when you work
near a lead-acid battery.
10. Do not operate charger if it has received a sharp blow,
been dropped or otherwise damaged in any way; return it to
a qualified service source.
11. Do not disassemble charger; Take it to a qualified
service source when repair or service is required. Incorrect
reassembly may result in a risk of electrical shock or fire.
12. To reduce risk of electrical shock, unplug charger from
outlet before attempting any maintenance or cleaning.
WARNING
RISK OF EXPLOSIVE GASES
1. WORKING IN VICINITY OF A LEAD-ACID BATTERY IS
DANGEROUS. BATTERIES GENERATE EXPLOSIVE
GASES DURING NORMAL BATTERY OPERATION. FOR
THIS REASON, IT IS OF THE UTMOST IMPORTANCE
THAT EACH TIME BEFORE USING YOUR CHARGER,
YOU READ THIS MANUAL AND FOLLOW THE
INSTRUCTIONS EXACTLY.
2. To reduce risk of battery explosion, follow these directions
and those published by the battery manufacturer and the
manufacturer of any equipment you intend to use in vicinity
of the battery. Review cautionary marking on these products
and on engine.
2. Have plenty of fresh water and soap nearby in
case battery acid contacts skin, clothing or eyes.
3. Wear complete eye protection and clothing
protection. Avoid touching eyes while working near
battery.
4. If battery acid contacts skin or clothing, wash
immediately with soap and water. If acid enters
eyes, immediately flood eyes with running cold
water for at least 10 minutes and get medical
attention immediately.
5. NEVER smoke or allow a spark or flame in the
vicinity of battery or engine.
6. Be extra cautious to reduce risk of dropping a
metal tool onto battery. It might spark or short-circuit
battery or other electrical part that may cause
explosion.
7. Remove personal metal items such as rings,
bracelets. necklaces, and watches when working
with a lead acid battery. A lead acid battery can
produce a short circuit current high enough to weld a
ring or the like to metal. causing a severe burn.
8. Use charger for charging a LEAD-ACID
BATTERY ONLY. Do not use battery charger for
charging dry-cell batteries that are commonly used
with home appliances. These batteries may burst
and cause injury to persons and damage to
property.
9. NEVER charge a frozen battery.
4