Interacter ICS 12/25A, ICS 24/25A, ICS 36/20A, ICS 48/20A, PS 12/5 Owner's Manual

...
BATTERY CHARGER
OWNER'S MANUAL
INTERACTER
II MODELS
PROFESSIONAL, LINEAGE, EX and INDUSTRIAL/ COMMERCIAL SERIES
6, 8, 12, 16, 24,36 and 48 Volt
---- CAUTION ----
READ THIS MANUAL CAREFULLY FOR
PROPER USE OF THE CHARGER
*** SAVE THESE INSTRUCTIONS ***
IMPORTANT SAFETY INSTRUCTIONS
Interacter offers a range of high performance Battery Chargers fo ruse in demanding applications, featuring a
patented
The models provides fast charging and optimal timing over a wide range of battery sizes and depths of discharge.
microprocessor system that out-performs all industry standard chargers in the same price range.
THREE STAGE Constant Current, Constant Voltage, Proportionally timed system used in all Interacter
STANDARD FEATURES OF ALL INTERACTER CHARGERS:
HIGH ENERGY RETURN, FAST CHARGINGCONSTANT CURRENT FIRST STAGEDUAL VOLTAGE LIMIT (CYCLIC/ STANDBY)PROPORTIONAL TIMED CYCLIC CHARGE STAGECONSTANT VOLTAGE FLOAT STANDBYAUTOMATIC SAFETY OVERRIDE TIMERSTART DELAY ON BATTERY CONNECTSHORT AND REVERSE CONNECTION SHUTDOWNRUGGED SCR PHASE CONTROLMAINS ZERO-CROSSING BATTERY SENSING
LINEAGE SERIES (LS) MODELS are the most cost effective series and are available for 6, 12, 24, 36, and 48 volt batteries rated at up to 6 amps.
EX SERIES (EX) Utilizes the LS controls in a more compact and wall mountable package. PROFESSIONAL SERIES (PS) MODELS are available for 12 and 24 volt batteries, rated at up to 10 Amps. In addition to the
above features, they include Temperature Compensation, an LED Ladder Amp Meter, an 80% charging indicator and an internal preset “Battery Type” switch allowing the unit to be easily configured for use with Gel Cell, Sealed Lead Acid or Liquid Electrolyte batteries.
INDUSTRIAL/ COMMERCIAL SERIES (ICS) MODELS are heavy duty chargers available for 12,24,36, or 48 volt batteries ratedat up to 25 Amps. The ICS models provide all the same features as the PS models together with higher current ratings.
INDUSTRIAL/ COMMERCIAL SERIES
12,24,36,& 48 VOLT
SPECIFICATIONS
PROFESSIONAL SERIES
12 & 24 VOLT
SPECIFICATIONS
MODEL ICS 12/25A INPUT: 117 Volts AC 60Hz, 480 VA OUTPUT: 12 Volts DC, 25 Amps
MODEL ICS 24/25A INPUT: 117 Volts AC 60Hz, 900 VA OUTPUT: 24 Volts DC, 25 Amps
MODEL ICS 36/20A INPUT: 117 Volts AC 60Hz, 1120 VA OUTPUT: 36 Volts DC, 20 Amps
MODEL ICS 48/20A INPUT: 117 Volts AC 60Hz, 1500 VA OUTPUT: 48 Volts DC, 20 Amps
Optional Export AC Input Ratings 100v-50Hz AC Input (Japan) 115/ 230v -50Hz AC Input (Europe) (CE) Full Wave Phase Controlled Rectification CONTROL: Voltage limit: Normal Mode 2.42 V/Cell Gel-Cell Mode 2.33 V/Cell Liquid Electrolyte Mode 2.62 V/Cell Current limited to AMP rating MEAN DC. Automatic timer starts when first stage voltage limit reached. Proportional CV stage timer - t/2+1 hour. Constant voltage 2.3 V/Cell after timeout, with Temperature Compenation. PROTECTION: Electronic reverse polarity. Short circuit shutdown and current limit. Combined Circuit Breaker and power switch on front panel. BATTERY TYPE & RATING (See Page 11 BTS) ICS chargersare for use with Lead Acid Batteries of Minimum capacity 50 AH, Gel Cell, Absorbed Electrolyte or Liquid Electrolyte types by using the BTS (Battery Type Switch)
DIMENSIONS: (Inches)
12.0 " WIDE, 7.0" FRONT TO BACK, 7.0" HIGH
CONFORMS
TO
U.L. 1236
MODEL PS 12/5 INPUT: 117 Volts AC 60Hz, 110 VA OUTPUT: 5 Amps DC 12 Volts
MODEL PS 12/10 INPUT: 117 Volts AC 60Hz, 220 VA OUTPUT: 10 Amps DC 12 Volts
MODEL PS 24/5 INPUT: 117 Volts AC 60Hz, 200 VA OUTPUT: 5 Amps DC 24 Volts
MODEL PS 24/8 INPUT: 117 Volts AC 60Hz, 320 VA OUTPUT: 8 Amps DC 24 Volts
Optional Export AC Input Ratings 100v-50Hz AC Input (Japan) 115/ 230v -50Hz AC Input (Europe)
Full Wave Phase Controlled Rectification CONTROL:
Voltage limit: Normal Mode 2.42 V/Cell Gel-Cell Mode 2.33 V/Cell Liquid Electrolyte Mode 2.62 V/Cell
Current limited to AMP rating MEAN DC. Automatic timer starts when first stage voltage limit
reached. Proportional CV stage timer - t/2+1 hour. Constant voltage 2.3 V/Cell after timeout, with
Temperature Compensation. PROTECTION: Electronic reverse polarity. Short circuit shutdown. and current limit. AC Input fuse in AC Input connector
BATTERY TYPE & RATING (See Page 11 BTS) PS chargers are for use with Lead Acid Batteries, Gel Cell Absorbed Electrolyte or Liquid Electrolyte types by using the BTS (Battery Type Switch)
DIMENSIONS: (Inches)
6.5" WIDE, 6.0" FRONT TO BACK, 5.25" HIGH
2
LINEAGE and EX SERIES
SPECIFICATIONS
MODEL: LS 6/6, LS 12/2, LS 12/6, LS 24/3 LS 24/5, LS 36/3, LS 48/5, EX 24/3
Full Wave Phase Controlled Rectification
IMPORTANT SAFETY
INSTRUCTIONS
1. IMPORTANT SAVE THESE INSTRUCTIONS-- This manual contains important safety and operating instructions for all INTERACTER battery chargers.
CONTROL: Voltage limited to 2.4 Volts/Cell
Current limited to AMP rating Mean D.C. Finish voltage 2.3 Volts/Cell Proportional Timed Cyclic Charge Stage Flashing Yellow LED-to Show 80% State of Charge
PROTECTION: Electronic reverse polarity
Short circuit shutdown Low voltage start Optional: Temperature compensation
DIMENSIONS: Lineage Series
6.5" WIDE, 6.0" FRONT TO BACK, 5.25" HIGH
DIMENSIONS: EX Series
3.5 WIDE, 3.25 FRONT TO BACK, 6.0 HIGH
LISTED
CONFORMS TO U.L. 1236
2. Before using this battery charger, read all instructions and cautionary markings on (1) the battery charger, (2) the battery, (3) product using the battery.
3.CAUTION--To reduce risk of injury, charge only lead acid, maintenance free or flooded lead acid type rechargable batteries. Other types of batteries may burst causing personal injury and damage.
4. Do not expose charger to rain or snow.
5. Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire, electric shock or injury to person.
6. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when disconnecting charger.
7. Make sure cord is located so that it will not be stepped on, tripped over or otherwise subjected to damage or stress.
8. An extension cord should not be used unless absolutely necessary. Use of improper extension cord could result in risk of fire and electrical shock. If an extension cord must be used, make sure:
a. That pins on plug of the extension cord are the
same number, size and shape as those of the plug on the charger.
b. That the extension cord is properly wired
3
c. That the wire size is large enough for the A/C ampere rating of the charger as specified in the table below:
LENGTH OF CORD (feet) AWG Wire Size
9. Do not operate charger with damaged cord or plug. REPLACE THEM IMMEDIATELY.
25 50 100 150 18 18 16 14
PERSONAL PRECAUTIONS
1. Someone should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery.
10. Do not operate charger if it has received a sharp blow, been dropped or otherwise damaged in any way; return it to a qualified service source.
11. Do not disassemble charger; Take it to a qualified service source when repair or service is required. Incorrect reassembly may result in a risk of electrical shock or fire.
12. To reduce risk of electrical shock, unplug charger from outlet before attempting any maintenance or cleaning.
WARNING
RISK OF EXPLOSIVE GASES
1. WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF THE UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY.
2. To reduce risk of battery explosion, follow these directions and those published by the battery manufacturer and the manufacturer of any equipment you intend to use in vicinity of the battery. Review cautionary marking on these products and on engine.
2. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.
3. Wear complete eye protection and clothing protection. Avoid touching eyes while working near battery.
4. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eyes, immediately flood eyes with running cold water for at least 10 minutes and get medical attention immediately.
5. NEVER smoke or allow a spark or flame in the vicinity of battery or engine.
6. Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit battery or other electrical part that may cause explosion.
7. Remove personal metal items such as rings, bracelets. necklaces, and watches when working with a lead acid battery. A lead acid battery can produce a short circuit current high enough to weld a ring or the like to metal. causing a severe burn.
8. Use charger for charging a LEAD-ACID BATTERY ONLY. Do not use battery charger for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to persons and damage to property.
9. NEVER charge a frozen battery.
4