According to the European WEEE directive, electrical and
electronic equipment must not be disposed with consumers waste.
Its components must be recycled or disposed apart from each other.
Otherwise contaminative and hazardous substances can pollute
our environment.
You as a consumer are committed by law to dispose electrical and electronic
devices to the producer, the dealer, or public collecting points at the end of the
devices lifetime for free. Particulars are regulated in national right. The symbol
on the product, in the user's manual, or at the packaging alludes to these
terms. With this kind of waste separation, application, and waste disposal of
used devices you achieve an important share to environmental protection.
1.0 Safety Instruction
Put the Device always on a stable and straight Surface. In case
of falling it can be damaged.
Don’t place the Device into direct Sunlight or in Places with high
Temperature. This can damage the Device or shorten his
average useful Life.
Don’t place it in the near of Heat Sources, like Radiators or other
heat producing Devices.
Don’t expose the Device to Rain, Water, Wetness or high Humidit y.
Don’t place it in the Bathroom or the Kitchen in the near of a Sink.
Avoid the direct Contact with Water.
Don’t try to open the Device.
Prior to the first use of our product make a backup of your data.
We are not liable for any loss of data, unless you can accuse us
intention or gross negligence.
In any case, liability for loss of data is limited to the effort that is
necessary to restore from existing backup copies.
Please read the Manual and Safety Instructions before using the
product for the first time. Otherwise damage can be the result.
1
Page 3
2.0 Introduction
Lan tester can easily read the correct pin configuration of
10Base-T cable, 10Base-2 cable, RJ45/RJ11 modular cables,
258A, TIA-568A/568B and Token Ring cable etc. by comparing
one transmitting end to the corresponding receiving end. With the
remote kit it can test cable installed far away either on wall plate
or patch panel. It is easy to verify the cable continuity, open, short
and cross-connect. Lt’s affordable, so you can benefit the most.
2.1 Specification
x Test the correct pin configuration of 10Base-T, 10Base-2
Ethernet cable, RJ45/RJ11 modular cables, 258A, TIA
568A/568B and Token Ring Cable etc.
x Easy to read cable status and verify cable continuity, open
short and miswire.
x With remote kit, it can remotely test cable far away either on
wall plate or patch panel.
x Test the grounding
x With auto or manual scan
x Operates with 9 Volt block battery (not included)
2.2 Package Contents
x 1 x Main Tester Unit
x 1 x Remote Unit
x 2 x BNC Adapter Cables
x 1 x BNC Male/Male Adapter
x 3 x RJ45 to RJ11 Adapters
x 1 x User Manual
2
Page 4
2.3 Product Profile:
6
5
7
11
Main Unit Remote Unit
1. RJ45 JACK
2. RJ45 JACK
3. LED DISPLAY FOR SOURCING END (JACK l)
4. LED DISPLAY FOR RECEIVING END (JACK 2)
5. POWER SWITCH
6. LED SCANNING MODE SWITCH
7. TEST SWITCH FOR MANUAL SCAN
8. RJ45 JACK
9. LED DISPLAY FOR RECEIVING END (SAME AS JACK 2)
10. GROUND LED FOR RECEIVING END
11. BATTERY COMPARTMENT (9V)
2
1
3
4
3
8
9
10
Page 5
3.0 OPERATION
3.1 Loopback Test
10Base-T Cable Test
1. Plug one end of tested cable on sourcing of RJ45 jack
(Marked with‘Ÿ') and another end of tested cable on
remaining receiving RJ 45 jack.
2. Slide power switch on, the upper row LEDs will start to scan
in sequence if the Auto/Manual switch is set on Auto mode, or
the LED will light on pin 1 if the Auto/Manual switch is set on
Manual mode.
Note: You have to make sure the battery power is sufficient. If
battery fails to the power, the LEDs will be dimmed or
hold up or no light, and the test result will be incorrect.
3. Choose the Auto/Manual switch to be Auto scan mode or
Manual scan mode by pressing the Auto/Manual switch.
4. In this moment the corresponding LED indicators of another
row of LED will light up simutaneousIy.
5. Read out the result of LED display. It tells you the pin
configuration status of the tested cable. If you fail to read the
result in the first run of LED scan, you may read it again in the
the test switch one by one until you read the result out.
Loopback
Tes t
4
Page 6
Modular Cable test
Please follow up the procedures of
10Base-T Cable Test.
However, the LED display should be
read as the right picture.
10Base-2 Cable Test
1. Plug the two attached BNC adaptor cables on both RJ45
jacks, then connect the tested cable both ends on BNC
adaptor cables.
2. As to the remaining procedures, you may refer to 10Base-T
cable test from step 1.2. to 1.5.
Note:
1). The center pin of BNC should be read on LED 1 and
shielding pin of BNC should be read on LED 2.
BNC CENTER PIN
BNC SHIELDING
2). As the 10Base-2 cable has only two wires, we suggest you
to read the result of LED scan by manual mode.
5
Page 7
3.2 Remote Test
1. Plug one end of tested cable on the sourcing RJ45 jack
(Marked with‘Ÿ') of master unit and another end on the
receiving RJ45 jack of remote unit. If the t ested cable has
already installed on the patch panel or wall plate, you may use
the adaptor cable to solve the connector gender problem.
Patch Panel Wall Plate
2. Now, set the Auto/manual switch on Auto mode if you work
test alone.
3. Read the test result from LED display on remote unit.
Note: The LED display on remote unit was scanned in
6
sequence corresponding to the sourcing end of master
unit.
Page 8
4.0 Test Result
1ˊContinuity˖ Pin 2 is continued
2. Open: Pin 2 is opened
3. Short: Pin 2 and Pin 3 are shorted
4. Miswire: Pin 3 and Pin 6 are miswired
5.0 Warning
This tester is not intended for use on powered circuits.
x
Attaching this tester to a powered circuit can result in
damage to the tester or injury to the user.
x lf you will not use the tester for a long time, take off the
According to the European WEEE directive,
electrical and electronic equipment must be
disposed with consumers waste. Its components
must be recycled or disposed apart from each
other. Otherwise contaminative and hazardous
substances can pollute our environment.
You as consumer are committed by law to
dispose electrical and electronic devices to
producer, the dealer, or public collecting points
at the end of the devices lifetime for free.
Particulars are regulated in national right. The
symbol on the product, in the user’s manual, or
at the packaging alludes to these terms. With
this kind of waste separation, application, and
waste disposal of used devices you achieve an
important share to environment protection.
1.0 Safety Instruction
Put the Devices always on a stable and straight
Surface. In case of falling it can be damaged.
Don’t place the Device into direct Sunlight or in
Places with high Temperature. This can damage
the Device or shorten his average useful life.
Don’t place it in the near of Heat Sources, like
Radiators or other heat producing Devices.
Don’t expose the Device to Rain, Water, Wetness
or high Humidity.
Don’t place it in the Bathroom or the Kitchen in
the near of a Sink.
Avoid the direct Contact with Water.
Don’t try to open the Device.
1
Congratulations to the Purchase of POE Test!
Please read the Manual and Safety Instruction
before using the product for the first time.
Otherwise damage can be the result.
2.0 Introduction
POE Test is made for measuring the power mode
of the POE equipment.
There are two connections: A class connection
(End-span) and B class connection (Middlespan). Both can be displayed through the LED
lights accurately and safely with the help of POE
Test. In short, it can efficiently avoid the damage
of the equipments caused by the type of power
mode with the POE Test.
2.1 Specification
POE Test is applied to the standard equipment of
IEEE 802.3af and IEEE 802.3at (POE Plus).
Operating Voltage 24V AC/DC^60V AC/DC
Operating Current <10mA
Insulation Voltage >1500VAC
2.2 Package Contents
1x Main Tester Unit
1x Test Cable
2x User Manual
2.3 Product Profile
4
2
3
1
Page 11
3.0 Operation
3.1 RJ45 Cable Test
1
4
1 Connect one end of RJ45 Cable with
RJ45 Jack of POE Test. Inset another end
into the port of POE equipment.
2 Power the POE equipment and switch
on the device.
3 Confirm whether the POE equipment works.
4
5 The lights of Typ A or Typ B lighting
up or flashing means ok.
4
Wait for 5 seconds’ introspection.
2
1
23
Alternative A
A class connection (End-Span).
Pin 1,2,3,6 powers.
Alternative B
B class connection (Mid-Span).
Pin 4,5,7,8 powers.