Intelix ASW-WP User Manual

HW Version
FW Version
Notes
1.0
6.0
Production Release
1.0
7.4
The audio receivers that were having issues decoding the
rectified.
1.0
8.0
VGA Audio should work with all displays, audio receivers
1080p timing information
Hardware/Firmware Version Log
Product: ASW-WP
Manufacturer: Intelix
VGA audio should now decode (this is yet to be verified).
When the unit powers up from Standby using a VGA
laptop, the signal is transmitted on the CAT5.
HDMI Sources will drop the Video Signal when the unit
goes into Standby or is powered down
Faster Switching and response time to the user.
• The timers are more reliable.
The wakeup time from an HDMI source will take about 3
seconds.
EDID will be read properly every time by the source on
unit power up, on Wakeup from standby and on unplugging and plugging in of the source cable.
The unit will not go to standby, ever, based on No
Activity. It will still go to standby within 30 minutes of no signal detection.
HDMI will wake up the unit even when a VGA source is
plugged in.
If there is no monitor connected in EDID pass through
mode, the sources will read a default resolution of 1024x768.
When the unit wakes up from Standby it will switch over
to the input that resulted in the wake up.
The VGA signal will not drop out when the HDMI signal is
removed.
Occasional issue where VGA image is shifted to the left is
and projectors. The issue was in the audio infoframe information being sent to the sink device.
All Displays will display the proper resolution when
presenting a 1080p picture from the VGA input. The issue was the use of 1080i timing instead of the proper
HW Version
FW Version
Notes
1.0
8.0
If the ASW-WP powers up while no display is connected,
the factory.
in EDID pass through mode, it will automatically set its internal EDID to 1080p instead of the previous 1024x768 60Hz.
HDCP Compliance should always be in the ON state from
Loading...