Inteli Power 9100 PD9130, PD9140A, PD9145A, PD9155, PD9160A Owner's Manual

...
PD9130, PD9140A, PD9145A, PD9155, PD9160A, PD9180
OWNERS MANUAL
PROGRESSIVE DYNAMICS, INC.
POWER CONVERTER LIMITED WARRANTY
I. LIMITED WARRANTY: Progressive Dynamics, Inc. warrants its power converter to be free from defects in
material or workmanship under normal use and service; and limits the remedies to repair or replacement.
II. DURATION: This warranty shall extend for a period of two years from the original date of purchase, and is
III. WARRANTY EXCLUSIONS: This warranty specifically does not apply to:
A.Any power converter which has been repaired or altered in any way by an unauthorized person or
service station; B.Damage caused by excessive input voltage, misuse, negligence or accident; or an external force; C.Any power converter installed in a vehicle used for commercial purposes; D.Any power converter which has been connected, installed or adjusted or used other than in
accordance with the instructions furnished, or has had the serial number altered, defaced or removed; E.Cost of all services performed in removing and re-installing the power converter; and F.ANY LOST PROFITS, LOST SAVINGS, LOSS OF USE OF ENJOYMENT OR OTHER
INCIDENTAL DAMAGES ARISING OUT OF THE USE OF, OR INABILITY TO USE, THE
PRODUCT. THIS INCLUDES DAMAGES TO PROPERTY AND, TO THE EXTENT
PERMITTED BY LAW, DAMAGES FOR PERSONAL INJURY. THIS WARRANTY IS IN LIEU
OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.
V. CLAIM PROCEDURE: Upon discovery of any defect, Progressive Dynamics, Inc. shall be supplied the
following information by mail, telephone or fax, at the address listed below:
A.Name and address of the claimant; B.Name and model of the power converter; C.Name, year and model of the recreational vehicle in which the power converter was installed; D.Date of purchase; and E.Complete description of the claimed defect.
Upon determination that a warranty claim exists (a defect in material or workmanship occurring under normal use and service,) the power converter shall be shipped postage prepaid to Progressive Dynamics, Inc. together with proof of purchase. The power converter will be repaired or replaced and returned postage prepaid.
Progressive Dynamics Inc.
507 Industrial Rd.
Marshall, MI 49068
269.781.4241 Fax 269.781.7802
GENERAL INFORMATION
The INTELI-POWER 9100 series 120 VAC to 12 VDC power converters are state-of-the-art electronic converter / battery chargers. The INTELI-POWER 9100's are UL and CUL (Canadian) listed.
Their compact size and quiet operation gives greater flexibility in selecting the mounting location for either OEM installation or after market replacement.
All INTELI-POWER 9100 series converters incorporate the Total Charging Management System (TCMS) interface. The TCMS interface connects the converter to optional devices that can automatically control the output voltage of the converter thereby controlling the charge rate to the batteries.
The converter has been designed and tested to provide maintenance free operation. The INTELI-POWER 9100 line of power converters have undergone tens of thousands of hours of strenuous engineering testing to insure years of trouble free operation.
GENERAL OPERATION
The INTELI-POWER series will supply "clean" nominal 13.6 VDC power from input voltages that range from 90-130 VAC.
Operates With or Without a Battery Connected, the output of the INTELI-POWER 9100 converters are a regulated, filtered D.C. voltage that can power sensitive electronics without the need for a battery or other filtering.
NOTE At normal input voltages the full load rated capacity is available. At input voltages less than 105 VAC the converter may not supply full rated output capacity.
The full rated load (either 30,40,45, 55, 60 or 80 amps) is available for load, battery charging or both. When functioning as a regulated battery charger the INTELI-POWER 9100 converters have nominal voltage output of 13.6 VDC. The system was designed to sense voltage on the battery and will taper the charging current as the battery becomes charged. When the INTELI-POWER 9100 senses the battery is at full charge it will provide a trickle charge to maintain a full charge condition.
CAUTION IT IS IMPORTANT THAT THE FLUID LEVEL OF ANY CONNECTED BATTERIES BE CHECKED ON A REGULAR BASIS. ALL BATTERIES WILL “GAS” AND LOSE SOME FLUIDS WHEN CONTINUOUSLY CONNECTED TO ANY CHARGING SOURCE.
When the vehicle is to be stored for extended periods of time it is recommended that the batteries be disconnected, unless one of the optional devices are attached to the TCMS interface (see the owners manual for that device for more information). Re-connect once a month to maintain a full charge.
FEATURES
INTELLIGENT ... The INTELI-POWER 9100 thinks for
itself, by monitoring and sensing the load and ambient conditions.
MULTIPLE BATTERY CHARGING ... INTELI-POWER 9100 has the capability of charging multiple batteries at the same time! They can even charge a combination of different capacity batteries.
GFCI PROTECTION ... INTELI-POWER 9100 has the LOWEST ground fault leakage. With this unit, the user can confidently utilize the RV's AC outlets without being concerned about a ground fault interruption of the facilities power source.
REVERSE BATTERY PROTECTION CIRCUIT ... If a battery is accidentally hooked up backwards, the converter will be protected. The PD9130 has one 30 AMP ATC automotive style fuse. Models PD9160A, PD9155, PD9145A and PD9140A have two 30 AMP ATC automotive style fuses. Model PD9180 has three 30 AMP ATC automotive style fuses mounted externally that will blow if a reverse battery condition should occur. Note: if the unit has accessories plugged into the TCMS interface the TCMS plug must be removed to provide clearance to replace the fuses.
CAUTION
IF THE REVERSE BATTERY PROTECTION FUSES ARE BLOWN DURING INSTALLATION, CHECK TO SEE THAT THE BATTERY HAS BEEN CONNECTED PROPERLY BEFORE REPLACING THE FUSES. REPLACE THE FUSES ONLY WITH THE SAME TYPE AND RATING AS THE ORIGINAL FUSES. USING OTHER FUSES COULD RESULT IN THE CONVERTER BEING DAMAGED, VEHICLE DAMAGE, INJURY OR OTHER CONSEQUENCES (SEE WARRANTY).
SHORT CIRCUIT PROTECTION ... The "smart" converter, INTELI-POWER 9100, senses, within millionths of a second, if the output terminals have been shorted. If this condition should occur the converter first limits the current. Should the condition continue to exist the converter then reduces the current output, within thousandths of a second. The INTELI-POWER 9100 was designed to protect itself. Once the "short circuit" has been corrected the INTELI-POWER 9100 will automatically return to normal operating conditions.
THERMAL PROTECTION ... If a over temperature condition should occur due to air flow obstruction or improper installation the INTELI-POWER 9100 senses the condition and decreases power output until the unit returns to normal operating temperature. Full output capacity will return as the unit cools down.
IGNITION PROTECTION ... All INTELI-POWER 9100 series converters are ignition protected.
INTERNAL COMPONENT COOLING ... The system is so efficient that if demand is less than 20% of the rated capacity, the auxiliary cooling fan will NOT activate. This means that at night when the power demand is reduced the fan may not come on at all. The location of the fan allows for the maximum cooling of both the case and components.
OVERVOLTAGE PROTECTION ... If the Input Voltage exceeds a preset limit the converter will shut-down to prevent damage. The unit will return to normal operation when the voltage returns to normal
INSTALLATION INSTRUCTIONS
Horizontal mounting of the INTELI-POWER 9100, is recommended although it can be mounted in any position that provides unobstructed ventilation to the fan and vent holes. Secure the converter firmly to the mounting surface using standard fasteners.
The OEM should test the INTELI-POWER 9100 under full load conditions in its intended mounting location. This will insure that there is sufficient unobstructed ventilation to the converter allowing it to operate at its maximum rated load. Failure to provide adequate ventilation to the converter will cause the converter to cycle on and off as it responds to ambient conditions.
! ATTENTION !
USE A 5/32" HEX DRIVER TO TIGHTEN THE OUTPUT SCREWS. DO NOT EXCEED 50 IN-LB TORQUE. PD9160 AND PD9180 USE A SLOTTED SCREWDRIVER TO TIGHTEN THE OUTPUT SCREWS
THE OUTPUT TERMINALS ARE RATED FOR 2 TO 14 GA. COPPER OR ALUMINUM WIRE.
THE INTELI-POWER 9100 CONVERTERS ARE NOT WEATHER TIGHT OR DESIGNED FOR WET LOCATION MOUNTING. THEY MUST BE PROTECTED FROM DIRECT CONTACT WITH WATER.
THE INTELI-POWER 9100 CONVERTERS ARE NOT DESIGNED FOR ZERO CLEARANCE COMPARTMENTS.
DURING THE MANUFACTURING PROCESS AVOID THE INTRODUCTION OF FOREIGN MATERIALS INTO THE CASE AS THIS COULD CAUSE A MALFUNCTION OF THE CONVERTER.
TROUBLE SHOOTING GUIDE
PROBLEM POSSIBLE CAUSES ACTION
1. No Output120 VAC supply not connectedConnect power supply Check AC distribution panel for proper operation
External Fuses BlownCheck for Reverse Polarity
Replace Fuses with same type and rating
Short CircuitTrace RV Circuits for possible fault Unit has shutdown due to overheatingCheck air flow
Allow unit to cool
Unit has shutdown due to over voltageCheck input voltage (Also see Item 5 below)Converter will shut down if the input voltage exceeds 132
Volts Correct Input Voltage
2. External Fuses
Blown
3. Converter cycles on
& off
4. Low OutputExcessive Load for ConverterReduce load requirements or Install Larger Converter
5. Intermittent or no
Output on Generator, works on Shore Power
Reverse Battery Hook UpCorrect Hook up and replace Fuses with same type and
rating
Compartment gets too hotCheck air flow to the converter
Improve Ventilation to the compartment
Input Voltage not between 105-130 VAC Bad Battery Cell(s)Replace Battery Unit has shutdown due to over voltage.Add another load to the generator, this may reduce the
Some generators exhibit excessive voltage spikes on the AC power output, this may cause the over voltage protection to shut the unit down
Correct input supply voltage
“spikes” to an acceptable level
Contact generator manufacturer for possible defect in the generator
Do not replace the converter unless the following checks have been performed:
1.Loosen the screw on the positive terminal and disconnect the positive wire. Read the converter output voltage using a DC voltmeter. If the voltage is above 13 volts, the converter is working properly.
2.If the converter output is zero volts, use an AC voltmeter to check for proper voltage at the 120 VAC outlet that the converter is plugged into. This voltage should be between 105 and 130 volts.
3.Check the fuses located at the front of the converter. These fuses will only blow if the battery or DC output leads were connected in reverse, even for a moment. Replace the fuses and repeat step 1.
NOTE: When replacing fuse(s) the TCMS plug must be removed to provide clearance for fuse replacement.
PD9130
INPUT/OUTPUT SPECIFICATIONS
PD9140A
PD9145A
Input: 105-130 VAC 60 Hz
500 Watts
Output: 13.6 VDC, 30 Amps
Dimensions: 4.5H x 7L x 7.25W
Weight: 4lbs
PD9155
Input: 105-130 VAC 60 Hz
900 Watts
Output: 13.6 VDC, 55 Amps
Dimensions: 4.5H x 10L x 7.25W
Weight: 5.4lbs
Input: 105-130 VAC 60 Hz
600 Watts
Output: 13.6 VDC, 40 Amps
Dimensions: 4.5H x 8.625L x 7.25W
Weight: 4.5lbs
PD9160A
Input: 105-130 VAC 60 Hz
1000 Watts
Output: 13.6 VDC, 60 Amps
Dimensions: 3.6H x 9.15L x 9W
Weight: 5.8lbs
Input: 105-130 VAC 60 Hz
725 Watts
Output: 13.6 VDC, 45 Amps
Dimensions: 4.5H x 8.625L x 7.25W
Weight: 4.5lbs
PD9180
Input: 105-130 VAC 60 Hz
1300 Watts
Output: 13.6 VDC, 80 Amps
Dimensions: 3.6H x 11.65L x 9W
Weight: 7.5lbs
CAUTION RISK OF FIRE:
Chassis bonding wire must be a separate wire ran directly to chassis from the Grounding Lug provided on the side of the converter. DO NOT connect Output negative to chassis using the same wire.
109205 REV L 10/02