INTELCO INTD1001/1, INTD1001/2, INTD1001/8, INTD1001/S, INTD1001/E8 Reference Manual

...
www.intelco.com.gr
INTD1001
Metal Keypad for access control
INTD1001 Keylock
Please read the instructions carefully in order to get
all of the benefits of this device.
Page 3 Features - Specifications
Page 4 Wiring
Page 5 Operation
Page 6-7 Programming
Page 8 Buzzer Sounds
Reference Manual
Rev. 1.00 January 2015
INTELCO ELECTRONICS 2 ISO9001/2008 Rev. 1.00 January 2015
The dial keypad INTD1001, with its multitude of different functions which are inte­grated in its program, can be used in elevators for access control to private floors, such as office buildings and apartments.
The device INTD1001 is offered in a range of models to cover the needs of the customer at the lowest possible cost. Model series: INTD1001 / 1: One Relay command. INTD1001 / 2: Two Relay commands. INTD1001 / 4: Four Relay command. INTD1001 / 8: Eight Relay commands. INTD1001 / S: With one Relay and serial communication with extension device. INTD1001 / E8: Extension device 8 Relays with serial communications.
General Description:
Dear customer, Thank you for choosing one of INTELCO Electronics products. Intelco Electronics is studying and producing products the last 30 years, always applying the latest developments, in the international market of electronic and lifts. Intelco Electronics with continuous presence in international exhibitions, promotes its prod­ucts in the international market having stable network customers in most countries of the European Union. People of INTELCO thank you and will always be there for any technical support.
INTELCO ELECTRONICS 3 ISO9001/2008 Rev. 1.00 January 2015
Specifications:
Up to 8 on board Relays acting like simple buttons.
3--Lever Security control of device.
Security 3 digit User password for each relay.
Time lock / unlock delay for each relay.
Latch mode supported for each relay.
False password “Detect and Lock” function.
Features:
Power supply
12 to 24 V DC/AC
Power consumption
0.3mA with 8 relay enabled
Security Levels
User Password
Admin Password
Supervisor Password
Extras
One On board Buzzer.
Operation temperature
0-80°C
Operation humidity
10-80% (non condensing)
Dimensions (External)
80.7 x 70.2 x 42 mm (H x W x D)
Weight (Total/w Battery)
255g
INTELCO ELECTRONICS 4 ISO9001/2008 Rev. 1.00 January 2015
Schematic 1
Connect power supply (12-24V AC/DC) and outputs from relays to control panel and then power on. (see Schematic 1)
After Keylock is properly powered you will here a short sound (500ms) and then device is ready to use.
Wiring Connection:
Power Supply
CAUTION : Absolute maximum current for every relay are: 3A - 120VAC / 3A - 24VDC / 1A - 125V~.
Buzzer
Outputs
relay to control panel
INTELCO ELECTRONICS 5 ISO9001/2008 Rev. 1.00 January 2015
Keylock device is real-time monitoring its keypad and is ready to act individual for every onboard relay, according pressed combination of keys and according the programming codes. (see “Programming” section)
Every Key (1-8) on the keypad is refer to one relay at the bottom side of the device according the onboard printed number.
Each onboard relay has 2 working mode:
Act as Unprotected Relay :
At factory reset every Relay(1-8) act like Unprotected Relay , so by pressing one Key(1-8) then the corresponding relay will be armed. Leaving the pressed key(1-8) will release the relay too.
Act as Password Protected Relay:
After programming and enable one of Relay(1-8) working as Password Protected Relay then any action referred to this Key it will requires 3-digit code in order to take effect, in any other case action will be rejected.
Working a Relay as Password Protected Relay means that, number of relay followed by 3-digit code is requested to by pressed, in order to arm this Relay.
At this working mode each relay has some extra features:
Latch Mode Off (Timer Mode)
Latch Mode On
Activating a Password Protected Relay with “653” password set, requires the above combination of Key to be pressed.
Operation:
CAUTION : Absolute maximum current for every relay are: 3A - 120VAC / 3A - 24VDC / 1A - 125V~.
2 653
Relay
Current User password
of Relay
INTELCO ELECTRONICS 6 ISO9001/2008 Rev. 1.00 January 2015
Programming:
In this section demonstrate full functionality of Password Protected Relay working mode.
By enable password at any relay Password Protected Relay function is activated. Disable the last password has been set on a relay will Disable the Password Protected Relay function and Unprotected Relay function will be enabled.
Enable Password:
While desired relay password is disabled, set “000” as User / Old password (Factory preset password) and set any desired password at User / New password (Ex. “653”).
Note: Factory preset User password is “000”
Disable Password:
While desired relay password is enable, place the User / Old password and set “000” (Factory preset password) as User / New password, in order to disable the password.
Note: Factory preset User password is “000”
02 000 653
User / Old
password
User / New
password
Relay
02 653 000
User / Old
password
User / New
password
Relay
Programming User Password
INTELCO ELECTRONICS 7 ISO9001/2008 Rev. 1.00 January 2015
Change Password:
While password is enabled at one relay, user can change the password that has been set on this relay, to a new one.
Note: Change password works only in relay with password enabled before.
02 653 877
User / Old
password
User / New
password
Relay
Programming Latch Mode
Programming latch mode requires selected relay being in Password Protected Relay function.
Every Password Protected Relay act in 2 ways, Latch Off (Timer) / Latch On :
Latch Off (Timer):
In this mode, activating any relay (E.g. 2) will arm the Relay for selected period of time between 1-98 seconds and after that time, Relay will be released.
Caution: Factory preset Latch mode is Off and preset Delay Time is 2 seconds.
02 15 877
Delay
Time
Relay Current User password
of Relay
INTELCO ELECTRONICS 8 ISO9001/2008 Rev. 1.00 January 2015
Latch On:
In this mode, activating any relay (E.g. 2) will arm the Relay and hold its state until Relay has been deactivated ( by pressing the same sequence of keys as on activation), when Relay will be released.
Caution: Factory preset Latch mode is Off and preset Delay Time is 2 seconds.
02 99 877
Latch On
code
Relay Current User password
of Relay
Buzzer Sounds:
Buzzer helps the human interacts with the device in order to understand the process has been made in every step of the programming mode.
These Buzzer sounds sequence are explained at table below:
Description On Off Loop
USER / ADMIN AUTHORIZED
Accepted Instruction
250ms 0ms 1
Rejected Instruction
250ms 0ms 1
Program sequence
completed
250ms 250ms 2
Timeout Sequence
500ms 0ms 1
02 99 877
Instruction
Program sequence
Example:
INTELCO ELECTRONICS 9 ISO9001/2008 Rev. 1.00 January 2015
Programming Administrator Function
In this section demonstrate full functionality of programming Administrator Function.
Installer of Keylock is considered as Administrator of the device. Administrator can edit his own password. Furthermore administrator has some extra authority on the device which is the ability to disable User/s password/s, one by one or all together. This operation called Reset of User Password.
Change Administrator Password:
While device is powered up administrator can handle is password according the below way.
Note: Factory preset Admin password is “0000”
0000 3546
Admin / Old
password
Admin / New
password
Reset User Password:
In order to make this actions, administrator has to set the Admin password before. This way ensure that only unique administrator of current Keylock device can handle the users passwords.
Administrator can reset users password with 2 ways:
One-By-One:
Reset any password refers to Password Protected Relay.
All Together:
Reset all passwords refers to Password Protected Relays.
3546 02
Current Admin
password
Relay to
Reset
3546 99
Current Admin
password
Reset All
passwords
INTELCO ELECTRONICS 10 ISO9001/2008 Rev. 1.00 January 2015
Supervisor Password
If there is no possibility of using the admin password you should contact your retailer. The retailer will ask the Serial Number of the device, which will be used, after identification of the owner, in an algorithm that will generate Supervisor Password.
Programming Supervisor Password:
While device is powered up Supervisor password must be typed according the below way.
After code typed well device will response with 5 short buzzer sounds (150 ms pause between each other)
There is always the possibility to return the device to the factory for reprogramming the factory settings (Factory Reset).
XXXX
Retailer given
number