Please read carefully the instructions in order to
get all the benefits of this device.
INTD0909
www.pelekis.tech
Rev. 1.01 March 2016
Page 2
General Description:
The GSM gateway INTD0909 is an electronic device which can be used as a
stand alone voice & data communication gateway for almost any remote use. It is
specially
designed for elevator installations and combined with INTD0900, it unlocks many
features for reliable, robust and secure emergency GSM/Phone line calls.
The GSM gateway INTD0909 operates with 230V AC mains input or from a
backup battery (SLA type) 6,3V. If mains power fails, it switches to backup battery
operation and it can fully operate for up to 6 hour. The device does real time
battery charging/conditioning/maintaining and RF antenna signal strength
monitoring.
Combined with our external I/O expansion card, the INTD0909 can be transformed as an Input/output wireless remote monitoring and controlling device!
Caution : The installation and settings of the device, must be done by a qualified
person.
Specifications:
Power supply
On board battery type
Battery charger type
Power consumption
Network bands
Phone Line connection
230V AC 50Hz
Sealed Lead Acid GEL type 6V/1.3Ah
Trickle charging with MCU monitoring
3.5W continuous, all features on, all led on
GSM 850/900/1800/1900MHz
Standard RJ-45 jack
Ext. Line connection
SIM card type
On board connectivity
Operation temperature
Operation humidity
Dimensions (External)
Weight (Total/w Battery)
INTELCO ELECTRONICS 2 ISO9001/2015 Rev. 1.01 March 2016
0-60°C
10-80% (non condensing)
60 x 210 x 145 mm (H x W x D)
1Kg
Page 3
Wiring-Connection:
Connect the antenna at the terminal to the side of the box. Make sure for good
locking
Connect at the terminal PHONE of the device the telephone which will be used
(simple telephone or emergency telephone).
Install the SIM Card to SIM holder. Make sure that you have deactivated the
PIN number first.
Connect the 2 cables (Black and Red) to the right poles of the battery.
Connect the power cable to the terminal and plug it to the 230V AC.
Make a short circuit at the jumper “RESET” beside of the terminal BAT.
Fuse
Power
Outputs
Inputs
N
NC
L
R1
R1
C1
R2
C2
R1
C1
R2
C2
AC
Battery (6,3V)
RESET
INTELPHONE
External
INTELCO ELECTRONICS 3 ISO9001/2015 Rev. 1.01 March 2016
Line
Battery
Network
signal
strength
Net Status
LED Indication
SIM Card
Page 4
Quick-Start Setup:
STEP 1
In order to startup the GSM Gateway device, please power up the device and then
short RESET pins by placing the RESET jumper. At startup of the device one short
buzz sound.
STEP 2
Device makes a quick check on AC power supply. If there is no AC power, device
will start up, powered from Battery if connected and it is good charged. While device performs the action above all onboard leds are keep blinking every 500 ms .
STEP 3
After 4-5 sec device will start seeking for network to connect according to provider
of the applied SIM card and while this action S1,S2 and S3 leds are blinking and
Network led is blinking every 500 ms indicating that no network found till now. If
Network can not be found in a specific period of time, device timeout the process.
If Network did not found, device will work with “NO SIM Card detect” and can only
make outgoings call to (112) . If Network is approached device will work with “SIM Card detect” and fully functional.
STEP 4
When S1,S2 and S3 leds stop blinking and Network led blink every 3 seconds then
onboard buzzer will buzz 2 times with short pause between.
Double buzzing sound let the user know that the startup process is just finished and
device is READY FOR USE, with every feature available to the user according the
status of network connection.
Limited Voice Ready ( International Emergency Number (112))
Battery check
INTELCO ELECTRONICS 4 ISO9001/2015 Rev. 1.01 March 2016
Page 5
LEDs Indication
AC Led
LED status Description
ON
OFF
LED status Description
ON
OFF
Blink* (2 on / 4 off)
Blink* (0,5 on / 0,5 off)
AC power presents
AC power does not presents
LINE Led
Hook off
Hook on
Ringing
Connection established
NET Led
LED status Description
Blink* (0,5 on / 0,5 off)
Blink* (0,5 on / 3 off)
BAT Leds
LED status Description
ON
Blink* (3 on / 1 off) Battery over 70%.
Blink* (1 on / 3 off)
Network disconnected
Network connected
Battery is full charged
Battery over 50%
OFF
Signal Leds
LED status
S1 S2 S3
0 0 0
1 0 0
1 1 0
1 1 1 Signal < - 51dBm (Excellent)
Signal not Detectable or < -115dBm
Signal < - 91dBm (Weak)
Signal < - 71dBm (Good)
Description
Battery not connected
*Blink is in seconds.
INTELCO ELECTRONICS 5 ISO9001/2015 Rev. 1.01 March 2016
Page 6
SMS Programming Table
Command Description Edit - Delete Ask
USER AUTHORIZED
#0000#1#...n...,_,...n2..,...n3…*
1
2
Calling number (4)
Example : n =00302102323345
#0000#2#6974587393*
Low battery call number
Delete : #0000#2#_*
#0000#1#?
#0000#2#?
3
4
5
6
7
8
20
21
22
User password
Buzzer function
Missed call function
Ask monitor
Outputs-Relays
R1
R2
R1,R2
Inputs-Optocouplers
ADMIN AUTHORIZED
Admin password
Auto-run number
Voice function
#0000#3#1E5D*
#0000#4#0*(OFF)
#0000#4#1* (ON)
#0000#5#0*(OFF)
#0000#5#1* (ON)
-
#0000#7#R1=1✶ ,R1=0✶
#0000#7#R2=1✶ ,R2=0✶
#0000#7#R1=0,R2=0✶
#0000#7#R1=1,R2=1✶
#0000#8#0*(AUTO OFF)
#0000#8#1*(AUTO ON)
#1111#20#1E5D*
#1111#21#6974587393*
Delete : #1111#21#_*
#1111#22#0* (OFF)
#1111#22#1* (ON)
-
#0000#4#?
#0000#5#?
#0000#6#?
#0000#7#?
#0000#8#?
-
#1111#21#?
-
23
24
Ask IMEI
#1111#24#0* (OFF)
SIM Card notifications
#1111#24#1* (ON)
-
#1111#23#?
-
Note:
‘ _ ’ : Variable reset to 0, delete.
‘ * ’ : Save or Act on variable.
‘ ? ’ : Ask the content of variable.
‘ # ’ : Change parameter field.
‘ , ’ : Change scope of variable if more than one Ex.(#0000#7#R1=1,r8:0,r7=0,r1=0* )
INTELCO ELECTRONICS 6 ISO9001/2015 Rev. 1.01 March 2016
Page 7
Extra Information
For any extra information about installation or the operation mode of the device,
please refer to the GSM Reference Manual which is uploaded at our website.
Technical Support
For technical support of this product, please refer to the local distributor
or contact Intelco Electronics.