Operating: -1,000 to 10,000 ft
Non-Operating: -1,000 to 40,000 ft
Product Ecological Compliance
RoHS
5
7
)
Performance values vary by capacity and form factor
1.
2. Performance specifications apply to both compressible and incompressible data
3. MB/s = 1,000,000 bytes/second
4. 4KB = 4,096 bytes; 8 KB = 8,192 bytes
5. 1PB = 10
6. Please contact your Intel representative for details on the non-operating temperature range
7. Airflow out of server through PCIe Card Slot
15
Bytes
Order Number: 332164-003US
Ordering Information
Contact your local Intel sales representative for ordering information.
Intel® Solid-State Drive DC P3500 Series
Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the
absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future
definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
The information here is subject to change without notice. Do not finalize a design with this information.
Tests document performance of components on a particular test, in specific systems. Differences in hardware, software, or
configuration will affect actual performance. Consult other sources of information to evaluate performance as you consider
your purchase.
All documented endurance test results are obtained in compliance with JESD218 Standards; refer to individual sub-sections
within this document for specific methodologies. See www.jedec.org for detailed definitions of JESD218 Standards.
The products described in this document may contain design defects or errors known as errata which may cause the product to
deviate from published specifications. Current characterized errata are available on request.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.
This document contains information on products in the design phase of development.
Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be
obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature.htm
Intel and the Intel logo are trademarks of Intel Corporation in the U.S. and other countries.
*Other names and brands may be claimed as the property of others.
2.7 Temperature Sensor .......................................................................................................................................................................... 15
2.8 Power Loss Capacitor Test ............................................................................................................................................................ 16
2.9 Hot Plug Support .................................................................................................................................................................................. 16
2.10 Out of Band Management (SMBUS) ....................................................................................................................................... 16
2.11 Variable Sector Size Support ....................................................................................................................................................... 16
3 Mechanical Information ................................................................................................................................................................... 17
4 Pin and Signal Descriptions .......................................................................................................................................................... 19
4.1 Pin Signal Definitions ........................................................................................................................................................................ 19
5.5 Temperature Statistics ..................................................................................................................................................................... 27
5.6 Drive Marketing Name Log ........................................................................................................................................................... 27
5.7 SET Feature Identifiers .................................................................................................................................................................... 28
6 NVMe Driver Support ........................................................................................................................................................................ 30
7 Certifications and Declarations .................................................................................................................................................. 31
Appendix A IDENTIFY Data Structure ......................................................................................................................................... 32
Appendix B Vital Data Structure...................................................................................................................................................... 40
Appendix C Out of Band Temperature Sensor Read Out ............................................................................................... 41
Appendix D Appendix D PCIe ID ...................................................................................................................................................... 42
Appendix E Appendix E SCSI Command Translation ....................................................................................................... 43
Appendix F Appendix F Add-in Card LED Decoder ............................................................................................................. 44
May 2015 Product Specification
332164-003US 3
Intel® Solid-State Drive DC P3500 Series
Figures
Figure 3-1Intel SSD DC P3500 Series SFF Dimensions ........................................................................................................................ 17
Figure 3-2Intel SSD DC P3500 Series PCIe Dimensions ...................................................................................................................... 18
Table 1: Standard Information Referenced in this Document ........................................................................................... 7
Table 2: Glossary of Terms and Acronyms .................................................................................................................................. 8
Table 3: User Addressable Sectors ................................................................................................................................................. 9
Table 4: Random Read/Write Input/Output Operations Per Second (IOPS) ............................................................... 9
Table 5: Random Read/Write IOPS Consistency ................................................................................................................... 10
Table 6: Sequential Read and Write Bandwidth .................................................................................................................... 10
Table 8: Quality of Service ............................................................................................................................................................... 11
Table 9: Operating Voltage .............................................................................................................................................................. 11
Table 10: Power Consumption ......................................................................................................................................................... 12
Table 30: Power State Descriptor .................................................................................................................................................... 36
Table 32: LBA Format Data Structure ............................................................................................................................................ 39
Table 33: Vital Product Data Structure (VPD) ............................................................................................................................ 40
Table 34: Capability List Pointer (Out of Band Temperature Sensor) ............................................................................ 40
Table 35: Register 0x05 read out format ..................................................................................................................................... 41
Table 36: PCIe ID ..................................................................................................................................................................................... 42
Table 37: LED Functionality ............................................................................................................................................................... 44
Product Specification May 2015
4 332164-003US
Intel® Solid-State Drive DC P3500 Series
Revision
Number
Description
Revision Date
001
Initial release
March 2015
002
Updated Table 3: User Addressable Sectors – Unformatted Capacity
April 2015
003
Table 9: Min Off time changed from 500 ms to 3 seconds and
Clarified Slew Rate Specifications
Removed inaccurate 2.5-inch Form Factor Pin Locations illustration
May 2015
Revision History
§
May 2015 Product Specification
332164-003US 5
Intel® Solid-State Drive DC P3500 Series
1 Overview
This document describes the specifications and capabilities of the Intel® Solid State Drive (SSD)
DC P3500 Series.
The Intel SSD DC P3500 Series is a PCIe Gen3 SSD architected with the new high performance controller interface NVMe (Non-Volatile Memory express) delivering leading performance, low latency and QoS (Quality of Service).
Matching the performance with world-class reliability and endurance, Intel SSD DC P3500 Series offer a range of
capacity – 400GB, 1.2TB, and 2TB in both AIC (Add-In card) and 2.5-inch form factor.
With PCIe* Gen3 support and NVMe queuing interface, the Intel SSD DC P3500 Series delivers excellent sequential
read performance of up to 2.7 GB/s and sequential write speeds of up to 1800MB/s. Intel SSD DC P3500 Series
delivers very high random read IOPS of 440K and random write IOPS of 68K for 4KB operations. Taking advantage
of the direct path from the storage to the CPU by means of NVMe, Intel SSD DC P3500 Series exhibits low latency
of less than 18 μs for sequential access to the SSD.
The 2.5-inch Intel SSD DC P3500 Series takes advantage of the 8639 connector and provides
hot-pluggable removal and insertion providing in-service replacement options.
Intel SSD DC P3500 Series includes these key features:
Consistently High IOPS and throughput
Sustained low latency
Variable Sector Size and End-to-End data-path protection
Enhanced power-loss data protection
Power loss protection capacitor self-test
Out of band management
Thermal throttling and monitoring
Product Specification May 2015
6 332164-003US
Intel® Solid-State Drive DC P3500 Series
Date
Title
Location
Jan 2013
Enterprise SSD Form Factor Version 1.0a
http://www.ssdformfactor.org
Feb 2012
NVMe Revision 1.0c
http://www.nvmexpress.org
Nov 2010
PCIe* Base Specification Revision 3.0
http://pcisig.com
July 2012
Solid-State Drive (SSD) Requirements and Endurance
Test Method (JESD219)
http://qdms.intel.com/
Click Search MDDS Database and
search for material description
datasheet
1995
1996
1995
1995
1997
1994
International Electrotechnical Commission EN 61000
4-2 (Electrostatic discharge immunity test)
4-3 (Radiated, radio-frequency, electromagnetic field
immunity test)
4-4 (Electrical fast transient/burst immunity test)
4-5 (Surge immunity test)
4-6 (Immunity to conducted disturbances, induced by
radio- frequency fields)
4-11 (Voltage Variations, voltage dips, short interruptions
and voltage variations immunity tests)
http://www.iec.ch/
1995
ENV 50204
(Radiated electromagnetic field from digital radio
telephones)
http://www.dbicorporation.com/
radimmun.htm/
1.1 References
Table 1: Standard Information Referenced in this Document
May 2015 Product Specification
332164-003US 7
Term
Definition
ATA
Advanced Technology Attachment
CRC
Cyclic Redundancy Check
DAS
Device Activity Signal
DMA
Direct Memory Access
ECC
Error Correction Code
EEPROM
Electrically Erasable Programmable Read Only Memory
EXT
Extended
FPDMA
First Party Direct Memory Access
GB
Gigabyte
Note: The total usable capacity of the SSD may be less than the total physical capacity
because a small portion of the capacity is used for NAND flash management and
maintenance purposes.
Gb
Gigabit
HDD
Hard Disk Drive
HET
High Endurance Technology
KB
Kilobyte
I/O
Input/Output
IOPS
Input/Output Operations Per Second
ISO
International Standards Organization
LBA
Logical Block Address
MB
Megabyte (1,000,000 bytes)
MLC
Multi-level Cell
MTBF
Mean Time Between Failures
NOP
No Operation
NVMe
Non-Volatile Memory Express
PB
Petabyte
PCB
Printed Circuit Board
RDT
Reliability Demonstration Test
RMS
Root Mean Square
SSD
Solid-State Drive
TB
Terabyte
TYP
Typical
UBER
Uncorrectable Bit Error Rate
VPD
Vital Product Data
1.2 Terms and Acronyms
Table 2: Glossary of Terms and Acronyms
Intel® Solid-State Drive DC P3500 Series
§
Product Specification May 2015
8 332164-003US
Intel® Solid-State Drive DC P3500 Series
Intel SSD DC P3500 Series
Unformatted Capacity
(Total User Addressable Sectors in LBA Mode)
400GB
781,422,768
1.2TB
2,344,225,968
2TB
3,907,029,168
Specification1
Unit
Intel SSD DC P3500 Series
400GB
1.2TB
2TB
Random 4KB 70/30
Read/Write (up to)2
IOPS
65,000
65,000
80,000
Random 8KB 70/30
Read/Write (up to)2
IOPS
35,000
35,000
40,000
Random 4KB Read (up to)
IOPS
420,000
420,000
430,000
Random 4KB Write (up to)
IOPS
23,000
23,000
28,000
Random 8KB Read (up to)
IOPS
220,000
250,000
250,000
Random 8KB Write (up to)
IOPS
10,000
10,000
14,000
2 Product Specifications
2.1 Capacity
Table 3: User Addressable Sectors
NOTES:
1.1 GB = 1,000,000,000 bytes; 1 sector = 512 bytes or 520 bytes or 528 bytes LBA count shown represents total
user storage capacity and will remain the same throughout the life of the drive.
2.The total usable capacity of the SSD may be less than the total physical capacity because a small portion
of the capacity is used for NAND media management and maintenance. IDEMA or JEDEC standard is used.
2.2 Performance
Table 4: Random Read/Write Input/Output Operations Per Second (IOPS)
NOTES:
1.Performance measured using IOMeter* on Intel provided Windows Server 2012R2 driver with Queue Depth 128
(QD=32, workers=4). Measurements are performed on a full Logical Block Address (LBA) span of the drive. Power
mode set at 25W.
2. 4KB = 4,096 bytes
3. 8KB = 8,192 bytes
May 2015 Product Specification
332164-003US 9
Intel® Solid-State Drive DC P3500 Series
Specification1
Unit
Intel SSD DC P3500 Series
400GB
1.2TB
2TB
Random 4KB Read (up to)2
%
90
88
88
Random 4KB Write (up to)
%
90
90
90
Random 8KB Read (up to)3
%
90
88
85
Random 8KB Write (up to)
%
90
90
90
Specification
Unit
Intel SSD DC P3500 Series
400GB
1.2TB
2TB
Sequential Read1
MB/s
2,200
2,600
2,700
Sequential Write1
MB/s
1,000
1,200
1,800
Specification
Intel SSD DC P3500 Series
Latenct1 (TYP)
Read Sequential/Random
Write Sequential/Random
Power on to PCIe Config Ready
2
Power on to Controller Ready
3
20/120µs
20/30µs
2.0 sec
10.0 sec (TYP)
Table 5: Random Read/Write IOPS Consistency
NOTES:
1.Performance consistency measured using IOMeter* based on Random 4KB QD=128 (QD=32, workers=4) workload,
measured as (IOPS in the 99.9th percentile slowest 1-second interval)/(average IOPS during the test). Measurements
are performed on a full Logical Block Address (LBA) span of the drive once the workload has reached steady state but
including all background activities required for normal operation and data reliability
2. 4KB = 4,096 bytes
3. 8KB = 8,192 bytes
Table 6: Sequential Read and Write Bandwidth
Note:
Performance measured using IOMeter* with 64 KB (65,536 bytes) of transfer size with Queue
Depth 128. Power mode set at 25W.
Table 7: Latency
NOTES:
1. Latency measured using 4 KB (4,096 bytes) transfer size with Queue Depth equal to 1 using Windows Server 2012R2
2. Power On To Ready time measured from de-assertion of PCIe* reset to PCIe Config Ready state.
3. Power On to Controller ready signifies when drive can begin receiving PCIe commands from host based on a single
Product Specification May 2015
10 332164-003US
driver. Power mode set at 25W.
#PERESET. For power on from unsafe shutdown, power on to controller ready can take up to 20 seconds.
Intel® Solid-State Drive DC P3500 Series
Specification
Unit
Intel SSD DC P3500 Series
QD=1
QD=128
Quality of Service
1,2
(99%)
Reads
ms
0.150 (400GB)
0.120 (1.2TB and 2TB)
1.5 (400GB)
0.75 (1.2TB and 2TB)
Writes
ms
0.120 (400GB)
0.100 (1.2TB and 2TB)
18
Quality of Service
1, 2
(99.99%)
Reads
ms
4 5 Writes
ms
4
30
Electrical Characteristics
Intel SSD DC P3500 Series
3.3V Operating Characteristics: (Add-in Card only)
Operating Voltage range
Rise Slew Rate (Max/Min)
Fall Slew Rate (Max/Min)1
Noise level
Min Off time2
Inrush Current (Typical Peak)
3
Max Average Current
3.3 V (±10%)
66/3300 V/s
0.66/3300 V/s
300 mV pp 10Hz – 100 KHz
50 mV pp 100KHz – 20 MHz
3 seconds
1.5 A
3.0 A
12V Operating Characteristics:
Operating Voltage range
Rise Slew Rate (Max/Min)
Fall Slew Rate (Max/Min)1
Noise level
Min Off time2
Inrush Current (Typical Peak)
3
Max Average Current
12 V (+10%/-20%)
240/12000 V/s
2.4/12000 V/s
1000 mV pp 10Hz – 100 KHz
100 mV pp 100KHz – 20 MHz
3 seconds
1.5 A
2.1 A/ 2.45 A (Add-in Card/2.5” FF)
Table 8: Quality of Service
NOTES:
1.Device measured using IOMeter. Quality of Service measured using 4KB (4,096 bytes) transfer size on a random
workload on a full Logical Block Address (LBA) span of the driveonce the workload has reached steady state but
including all background activities required for normal operation and data reliability.
2.Based on Random 4KB QD=1,128 workloads, measured as the time taken for 99.0(or 99.99) percentile of commands
to finish the round-trip from host to drive and back to host.
2.3 Electrical Characteristics
Table 9: Operating Voltage
May 2015 Product Specification
332164-003US 11
Intel® Solid-State Drive DC P3500 Series
Electrical Characteristics
Intel SSD DC P3500 Series
3.3Vaux Operating Characteristics4:
Operating Voltage range
Rise Slew Rate (Max/Min)
Fall Slew Rate (Max/Min)1
Noise level
Max Current
3.3 V (±9%)
66/3300 V/s
0.66/3300 V/s
300 mV pp 10Hz – 100 KHz
50 mV pp 100KHz – 20 MHz
20mA/1mA (AIC/2.5” FF)
Specification
Unit
Intel SSD DC P3500 Series
400GB
1.2TB
2TB
Active Write - Average 1
W
12
15
20
Active Read - Average 2
W 9 9
10
Idle
W 4 4
4
NOTES:
1.Fall time needs to be equal or better than minimum in order to guarantee full functionality of enhanced power loss
management.
2. The drive must be powered off for at least 3 seconds before powering on.
3. Measured during initial power supply application. Typically this will be seen within 2 seconds of initial power up. Inrush
specified for 12V and 3.3V supply, not the 3.3V Aux.
4.3.3V aux is optional, not needed for power up or functionality. 3.3Vaux is needed for accessing VPD page by means of
SMBUS for both form factors.
Table 10: Power Consumption
NOTES:
1.The workload equates 128KB (131,072 bytes) Queue Depth equal to 128 sequential writes. Average
power is measured using scope trigger over a 100 ms sample period
Uncorrectable bit error rate will not exceed one sector in
the specified number of bits read. In the unlikely event of
a non-recoverable read error, the SSD will report it as a
read failure to the host; the sector in error is considered
corrupt and is not returned to the host.
< 1 sector per 1017 bits read
Mean Time Between Failures (MTBF)
Mean Time Between Failures is estimated based on
Telcordia* methodology and demonstrated through
Reliability Demonstration Test (RDT).
2 million hours
Data Retention
The time period for retaining data in the NAND at
maximum rated endurance.
3 months power-off retention once SSD
reaches rated write endurance at 40° C
Endurance Rating
The number of drive writes such that the SSD meets the
requirements according to the JESD218 standard.
Endurance rating verification is defined to establish UBER
<1E-16 at 60% upper confidence limit.
400GB: 219 TBW
1.2TB: 657 TBW
2.0TB: 1095 TBW
(0.3 drive writes/day*)
2.6 Reliability Specifications
Intel SSD DC P3500 Series meets or exceeds SSD endurance and data retention requirements as specified in the
JESD218 standard. Reliability specifications are listed in Table 15.
Table 15: Reliability Specifications
Note: Terabytes Written (TBW). Refer to JESD218 standard table 1 for UBER, FFR and other Enterprise SSD
requirements.
2.7 Temperature Sensor
The Intel SSD DC P3500 Series has an internal temperature sensor with an accuracy of +/-2° C over a range
of -10° C to +85° C which can be monitored using NVMe Health Log.
For more information on sensor reading see SMART attributes section. In addition, drive will provide out of band
access to temperature by means of SMBUS. The sensor has an accuracy of +/- 3° C over a range of -20° C to 125° C.
SMBUS temperature sensor will not be reported in NVMe Health Log.
May 2015 Product Specification
332164-003US 15
Intel® Solid-State Drive DC P3500 Series
2.8 Power Loss Capacitor Test
The Intel SSD DC P3500 Series supports testing of the power loss capacitor, which can be monitored using SMART
attribute critical warning in log page identifier 02h, byte 0, bit 4.
2.9 Hot Plug Support
2.5-inch form factor will support surprise hot plug feature in capable platforms and OSs. Intel SSD
DC P3500 Series supports orderly hot insertion and removal and surprise hot insertion by means of presence
detect and link-up detect. On surprise hot removal during IOs, Intel SSD DC P3500 Series will enable the integrity
of already committed data on the media and commit acknowledged writes to the media.
2.10 Out of Band Management (SMBUS)
Intel SSD DC P3500 Series provides out of band management by means of SMBUS interface. This requires 3.3V
Auxiliary voltage. SMBUS accesses a VPD page as listed in Appendix B through address 0X53.
Temperature sensor is accessed through address 0x1B. For temperature sensor access, temperature can be read by
the BMC (base) using Read Temperature Data Register (0x05) by means of SMBUS 0x1B. Bits [11:0] return raw
ambient temperature.
Host may also see 0x66 address in a bus scan. This is only used for write protecting the EEPROM during
manufacturing.
Note: In certain tools the address for the VPD and temperature sensor will appear as 0xA6 and 0x36 respectively,
due to bit shift.
2.11 Variable Sector Size Support
Intel SSD DC P3500 Series supports 512, 520, 528, 4096, 4104, 4160 and 4224 bytes of sector size. Intel SSD DC
P3500 Series will also support DIF as specified in NVMe 1.0 specification. 520 and 4104 Byte sector sizes can
support PI (protection information) which is 8 Byte long.
In terms of protection information action (PRACT), bit 29 of DWORD12 in READ/WRITE command should not be
equal to 1. Device only supports PRACT=0, implying protection information is passed to the SSD and checked by
the SSD.
§
Product Specification May 2015
16 332164-003US
Intel® Solid-State Drive DC P3500 Series
X – Length
Y – Width
Z – Height
100.45 Max
69.85 +/- 0.25
15.0 +0/-0.5
3 Mechanical Information
Figures 3-1 and 3-2 show the physical package information for the Intel SSD DC P3500 Series in the 2.5-inch form
factors. All dimensions are in millimeters.
Figure 3-1 Intel SSD DC P3500 Series SFF Dimensions
Note: Length does not include 0.3 connector protrusion
May 2015 Product Specification
332164-003US 17
Figure 3-2 Intel SSD DC P3500 Series PCIe Dimensions
Intel® Solid-State Drive DC P3500 Series
§
Product Specification May 2015
18 332164-003US
Intel® Solid-State Drive DC P3500 Series
Pin
Name
Description
Pin
Name
Description
S1
GND
Ground
E7
REFCLK0+
Reference clock port 0
S2 Not used (SATA/SAS)
E8
REFCLK0-
Reference clock port 0
S3 Not used (SATA/SAS)
E9
GND
Ground
S4
GND
Ground
E10
PETp0
Transmitter differential pair, Lane 0
S5 Not used (SATA/SAS)
E11
PETn0
Transmitter differential pair, Lane 0
S6 Not used (SATA/SAS)
E12
GND
Ground
S7
GND
Ground
E13
PERn0
Receiver differential pair, Lane 0
E1
REFCLK1+
Reference clock port 1
(not used)
E14
PERp0
Receiver differential pair, Lane 0
E2
REFCLK1-
Reference clock port 1
(not used)
E15
GND
Ground
E3
3.3Vaux
3.3V auxiliary power
E16
RSVD
Reserved
E4
PERST1#
Fundamental reset port 1
(not used)
S8
GND
Ground
E5
PERST0#
Fundamental reset port 0
S9 Not used (SATAe/SAS)
E6
RSVD
Reserved
S10 Not used (SATAe/SAS)
P1 Not used (SATAe/SAS)
S11
GND
Ground
P2 Not used (SATAe/SAS)
S12 Not used (SATAe/SAS)
P3 Not used (SATAe)
S13 Not used (SATAe/SAS)
P4
IfDet_N
Interface detect (drive
type)
S14
GND
Ground
P5
GND
Ground
S15
RSVD
Reserved
P6
GND
Ground
S16
GND
Ground
P7 Not used (SATA/SAS)
S17
PETp1
Transmitter differential pair, Lane 1
P8 Not used (SATA/SAS)
S18
PETn1
Transmitter differential pair, Lane 1
P9 Not used (SATA/SAS)
S19
GND
Ground
P10
PRSNT_N
Presence detect
S20
PERn1
Receiver differential pair, Lane 1
4 Pin and Signal Descriptions
4.1 Pin Signal Definitions
Table 16: Pin Definition for 2.5-inch Form Factor (8639 connector specification)
May 2015 Product Specification
332164-003US 19
Intel® Solid-State Drive DC P3500 Series
Pin
Name
Description
Pin
Name
Description
(also used for drive type)
P11
Activity
Activity signal from the
drive
S21
PERp1
Receiver differential pair, Lane 1
P12
Hot-Plug
Ground
S22
GND
Ground
P13
+12V_pre
12V power
S23
PETp2
Transmitter differential pair, Lane 2
P14
+12V
12V power
S24
PETn2
Transmitter differential pair, Lane 2
P15
+12V
12V power
S25
GND
Ground
S26
PERn2
Receiver differential pair, Lane 2
S27
PERp2
Receiver differential pair, Lane 2
S28
GND
Ground
E17
PETp3
Transmitter differential pair, Lane 3
E18
PETn3
Transmitter differential pair, Lane 3
E19
GND
Ground
E20
PERn3
Receiver differential pair, Lane 3
E21
PERp3
Receiver differential pair, Lane 3
E22
GND
Ground
E23
SMCLK
SMBus clock
E24
SMDAT
SMBus data
E25
DualPortEn_N
Dual port enable
NOTES:
SMCLK and SMDAT routes to an internal EEPROM which contains Vital Product Data (VPD).
PRSNT_N is kept open by the P3500 Series.
IfDet_N is grounded by P3500 Series.
DualPortEn_N pin should be left un-connected or un-driven by the system to enable single port operation with
all 4 lanes. If un-connected, P3500 Series will pull it high. However, if the pin is asserted by the system (driven
low by storage backplane), then P3500 Series will be configured as x2 lanes.
Transmit differential pair lanes have 22nF of AC coupling capacitance.
P11 is used for activity. When idle, logic level is low (LED Solid On). During IO activity and formatting,
pin toggles 250msec high, 250msec low signal.
P3500 Series only uses REFCLK0+ and REFCLK0- as reference clock pair.
P3500 Series only uses PERST0# as a fundamental reset.
3.3Vaux is only needed during SMBUS access to the VPDROM.
Product Specification May 2015
20 332164-003US
Intel® Solid-State Drive DC P3500 Series
Side B
Side A
Pin
Name
Description
Name
Description
1
+12V
12V power
PRSNT1#
Hot-Plug presence detect
2
+12V
12V power
+12V
12V power
3
+12V
12V power
+12V
12V power
4
GND
Ground
GND
Ground
5
SMCLK
SMBus(System Management Bus) clock
JTAG2
TCK (Test Clock), clock input for
JTAG interface
6
SMDAT
SMBus (System Management Bus) data
JTAG3
TDI (Test Data Input)
7
GND
Ground / UART_HOST
JTAG4
TDO (Test Data Output)
8
+3.3V
3.3V power
JTAG5
TMS (Test Mode Select)
9
JTAG1
TRST# (Test Reset) resets the JTAG
interface
+3.3V
3.3V power
10
3.3Vaux
3.3V auxiliary power
+3.3V
3.3V power
11
WAKE#
Signal for Link reactivation
PERST#
Fundamental reset
Mechanical Key
12
RSVD
Reserved
GND
Ground
13
GND
Ground
REFCLK+
Reference clock (differentialpair)
14
PETp0
Transmitter differential pair, Lane 0
REFCLK-
Reference clock (differentialpair)
15
PETn0
Transmitter differential pair, Lane 0
GND
Ground
16
GND
Ground
PERp0
Receiver differential pair, Lane 0
17
PRSNT2#
Hot-Plug presence detect
PERn0
Receiver differential pair, Lane 0
18
GND
Ground
GND
Ground
End of the x1 Connector
19
PETp1
Transmitter differential pair, Lane 1
RSVD
Reserved
20
PETn1
Transmitter differential pair, Lane 1
GND
Ground
21
GND
Ground
PERp1
Receiver differential pair, Lane 1
22
GND
Ground
PERn1
Receiver differential pair, Lane 1
23
PETp2
Transmitter differential pair, Lane 2
GND
Ground
24
PETn2
Transmitter differential pair, Lane 2
GND
Ground
25
GND
Ground
PERp2
Receiver differential pair, Lane 2
26
GND
Ground
PERn2
Receiver differential pair, Lane 2
27
PETp3
Transmitter differential pair, Lane 3
GND
Ground
28
PETn3
Transmitter differential pair, Lane 3
GND
Ground
Table 17: Pin Definition for Add-In Card (Half Height Half Length) Form Factor
May 2015 Product Specification
332164-003US 21
Intel® Solid-State Drive DC P3500 Series
Side B
Side A
Pin
Name
Description
Name
Description
29
GND
Ground
PERp3
Receiver differential pair, Lane 3
30
RSVD
Reserved
PERn3
Receiver differential pair, Lane 3
31
PRSNT2#
Hot-Plug presence detect
GND
Ground
32
GND
Ground
RSVD
Reserved
End of the x4 Connector
NOTES:
All pins are numbered in ascending order from the left to the right, with side A on the top of the centerline and
side B on the bottom of the centerline, use the reference drawing in Fig2, with the logo visible.
The PCI Express interface pins PETpx, PETnx, PERpx, and PERnx are named with the following convention: “PE”
stands for PCI Express high speed, “T” for Transmitter, “R” for Receiver, “p” for positive (+) and “n” for negative (-).
The sequential mating for Hot-Plug is accomplished by staggering the edge fingers on the add-in card.
§
Product Specification May 2015
22 332164-003US
Intel® Solid-State Drive DC P3500 Series
5 Supported Command Sets
Intel SSD DC P3500 Series supports all mandatory Admin and I/O commands defined in NVMe
(Non-Volatile Memory Express) revision 1.0.
5.1 NVMe Admin Command Set
The Intel SSD DC P3500 Series supports all mandatory NVMe commands, which are:
Delete I/O Submission Queue
Delete I/O Completion Queue
Create I/O Submission Queue
Create I/O Completion Queue
Get Log Page
Identify
Abort
SET Features
GET Features
Asynchronous Event Notification
Intel SSD DC P3500 Series also supports the following optional I/O commands defined in NVMe revision 1.0:
Firmware Activate
Firmware Image Download
Format NVM
Note: See Appendix A, “Identify Controller Data Structure” for details on commands and capabilities.
5.2 NVMe I/O Command Set
Intel SSD DC P3500 Series supports all the mandatory NVMe I/O command set defined in NVMe 1.0 specification,
which are:
Flush
Write
Read
Additionally, the following optional commands are supported:
Table 18 lists the SMART attributes supported by the Intel SSD DC P3500 Series in accordance with NVMe 1.0
specification.
Table 18: SMART Attributes (Log Identifier 02h)
Product Specification May 2015
24 332164-003US
Intel® Solid-State Drive DC P3500 Series
Byte
# of Bytes
Attribute
Description
32
16
Data Units Read (in LBAs)
Contains the number of 512 byte data units the
host has read from the controller; this value
does not include metadata. This value is
reported in thousands (i.e., a value of 1
corresponds to 1000 units of 512 bytes read)
and is rounded up. When the LBA size is a value
other than 512 bytes, the controller shall
convert the amount of data read to 512 byte
units.
48
16
Data Units Write (in LBAs)
Contains the number of 512 byte data units the
host has written to the controller; this value
does not include metadata. This value is
reported in thousands (i.e., a value of 1
corresponds to 1000 units of 512 bytes written)
and is rounded up. When the LBA size is a value
other than 512 bytes, the controller shall
convert the amount of data written to 512 byte
units. For the NVM command set, logical blocks
written as part of Write operations shall be
included in this value. Write Uncorrectable
commands shall not impact this value.
64
16
Host Read Commands
Contains the number of read commands issued
to the controller.
80
16
Host Write Commands
Contains the number of write commands issued
to the controller.
96
16
Controller Busy Time (in minutes)
Contains the amount of time the controller is
busy with I/O commands. The controller is busy
when there is a command outstanding to an I/O
Queue (specifically, a command was issued by
way of an I/O Submission Queue Tail doorbell
write and
the corresponding completion queue entry has
not been posted yet to the associated I/O
Completion Queue). This value is reported in
minutes.
112
16
Power Cycles
Contains the number of power cycles.
128
16
Power On Hours
Contains the number of power-on hours. This
does not include time that the controller was
powered and in a low power state condition.
144
16
Unsafe shutdowns
Contains the number of unsafe shutdowns. This
count is incremented when a shutdown
notification (CC.SHN) is not received prior to
loss of power.
160
16
Media Errors
Contains the number of occurrences where the
controller detected an unrecovered data
integrity error. Errors such as uncorrectable
ECC, CRC checksum failure, or LBA tag
mismatch are included in this field.
176
16
Number of Error Information Log Entries
Contains the number of Error Information log
entries over the life of the controller.
May 2015 Product Specification
332164-003US 25
Byte
# of Bytes
Attribute
Description
0
1
AB (Program Fail Count)
Raw value:
Shows total count of program fails.
Normalized value:
Beginning at 100, shows the percent
remaining of allowable program fails.
3
1
Normalized Value
5
6
Current Raw Value
12
1
AC (Erase Fail Count)
Raw value:
Shows total count of erase fails.
Normalized value:
Beginning at 100, shows the percent
remaining of allowable erase fails.
15
1
Normalized Value
17
6
Current Raw Value
24
1
AD (Wear Leveling Count)
Raw value:
Bytes 1-0: Min. erase cycle
Bytes 3-2: Max. erase cycle
Bytes 5-4: Avg. erase cycles
Normalized value: decrements from
100 to 0
27
1
Normalized Value
29
6
Current Raw Value
36
1
B8 (End to End Error Detection Count)
Raw value:
Reports number of End-to-End
detected and corrected errors by
hardware.
Normalized value: always 100
39
1
Normalized Value
41
6
Current Raw Value
48
1
C7 (CRC Error Count)
Raw value:
Shows total number of PCIe Interface
CRC errors encountered, as specified
in PCIe Link Performance Counter
Parameter for “Bad TLP”.
Normalized value: always 100
51
1
Normalized Value
53
6
Current Raw Value
60
1
E2 (Timed Workload, Media Wear)
Raw value:
Measures the wear seen by the SSD
(since reset of the workload timer,
attribute E4h), as a percentage of the
maximum rated cycles. Divide the raw
value by 1024 to derive the
percentage with 3 decimal points.
Normalized value: always 100
63
1
Normalized Value
65
6
Current Raw Value
72
1
E3 (Timed Workload, Host Reads %)
Raw value:
Shows the percentage of I/O
operations that are read operations
(since reset of the workload timer,
attribute E4h). Reported as integer
percentage from 0 to 100.
Normalized value: always 100
75
1
Normalized Value
77
6
Current Raw Value
84
1
E4 (Timed Workload, Timer)
Raw value:
Measures the elapsed time (number
of minutes since starting this
workload timer).
In addition to the SMART attribute structure, features pertaining to the operation and health of the Intel SSD DC
P3500 Series can be reported to the host on request through the Get Features command. Intel SSD DC P3500
Series can change settings using SET Features on the following items as defined in NVMe 1.0 specification.
The following table describes the NVMe* Driver Support for Intel SSD DC P3500 Series. The support includes
releasing and validating NVMe drivers for certain operating systems and validating functionality for open source
drive, inbox or native drivers for select operating systems.
Table 27: NVMe Driver Support
NOTES:
1. With Intel provided driver, full product specification is guaranteed, booting is only supported for 64bit OS
2. With open source non-Intel driver, compatibility and functionality is validated
§
Product Specification May 2015
30 332164-003US
Intel® Solid-State Drive DC P3500 Series
Certification
Description
CE Compliant
European Economic Area (EEA): Compliance with the essential requirements of EC
Council Directives Low Voltage Directive (LVD) 2006/95/EC, EMC Directive
2004/108/EC and Directive 2011/65/EU.
UL Recognized
Certified Underwriters Laboratories, Inc. Bi-National Component Recognition; UL
60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology
Equipment - Safety - Part 1: General Requirements)
C-Tick Compliant
Compliance with the Australia/New Zealand Standard AS/NZS3548 and
Electromagnetic Compatibility (EMC) Framework requirements of the Australian
Communication Authority (ACA).
BSMI Compliant
Compliance to the Taiwan EMC standard CNS 13438: Information technology
equipment - Radio disturbance Characteristics - limits and methods of measurement,
as amended on June 1, 2006,
is harmonized with CISPR 22: 2005.04.
KCC
Compliance with paragraph 1 of Article 11 of the Electromagnetic Compatibility
Control Regulation and meets the Electromagnetic Compatibility (EMC) Framework
requirements of the Radio Research Laboratory (RRL) Ministry of Information and
Communication Republic of Korea.
VCCI
Voluntary Control Council for Interface to cope with disturbance problems caused by
personal computers or facsimile.
Microsoft WHCK
Microsoft Windows Hardware Certification Kit
RoHS Compliant
Restriction of Hazardous Substance Directive
WEEE
Directive on Waste Electrical and Electronic Equipment
7 Certifications and Declarations
Table 28: Device Certifications and Declarations
§
May 2015 Product Specification
332164-003US 31
Intel® Solid-State Drive DC P3500 Series
Bytes
F = Fixed
V = Variable
X = Both
Default
Value
Interpretation
Description
1-0 F
8086h
Contains the company vendor
identifier that is assigned by the
PCI SIG
PCI Vendor ID (VID)
3-2 F
8086h
Contains the company vendor
identifier that is assigned by the
PCI SIG for subsystem
PCI Subsystem Vendor ID (SSVID)
23-4 V
varies
Contains the serial number for
the NVM subsystem
Serial Number (SN)
63-24 V
varies
Contains the serial number for
the NVM subsystem that is
assigned by the vendor as an
ASCII string
Model Number (MN)
71-64 V
varies
Contains the currently active
firmware revision for the NVM
subsystem
Firmware Revision (FR)
72 F 0h
Recommended Arbitration Burst
size equals 1
Recommended Arbitration Burst (RAB)
75-73 F
5CD2E4h
Contains the Organization
Unique Identifier (OUI) for the
controller vendor
IEEE OUI Identifier (IEEE)
76 X 0h
No of multiple PCI Express*
interfaces connected to the host,
bit 0 determines multiple
interface
Multi-Interface Capabilities (MIC)
77 F 05h
Supports MDTS of 128K
Maximum Data Transfer Size (MDTS)
255-78
Reserved
257-256 F
07h
Supports Security Send/Receive,
Format NVM and Firmware
Activate/Download
Optional Admin Command Support
(OACS)
258 F 03h
Supports up to 3 concurrently
outstanding abort commands
Abort Command Limit (ACL)
259 F 03h
Supports up to 3 concurrently
outstanding asynchronous event
requests
Asynchronous Event Request Limit (AERL)
260 X 03h
Single slot
Read/write capable
Firmware Updates (FRMW)
Appendix A IDENTIFY Data Structure
Table 29: Identify Controller
Product Specification May 2015
32 332164-003US
Intel® Solid-State Drive DC P3500 Series
Bytes
F = Fixed
V = Variable
X = Both
Default
Value
Interpretation
Description
261 X 0h
SMART/Health Log Support per
drive not per namespace
Log Page Attributes (LPA)
262 F 3Fh
Number of Error Information log
entries equals 64
Error Log Page Entries (ELPE)
263 F 0h
Number of NVM Express power
states equal 1
Number of Power States Support (NPSS)
264 F 0h
Configuration settings for Admin
Vendor Specific command
handling
Admin Vendor Specific Command
Configuration (AVSCC)
511-265
Reserved
512 F 66h
Required and max submission
queue entry size is 64 Byte
Submission Queue Entry Size (SQES)
513 F 44h
Required and max submission
queue entry size is 16 Byte
Completion Queue Entry Size (CQES)
515-514
Reserved
519-516
F
01h
Supports single namespace
Number of Namespaces (NN)
521-520
F
06h
Supports Dataset Management
and Write Uncorrectable
optional NVMe commands.
Optional NVMe Command Support
(ONCS)
523-522 F 0h
Fused commands not supported
Fused Operation Support (FUSES)
524 F 07h
Supports Crypto Erase and
format of entire drive, not per
namespace
Format NVM Attributes (FNA):
525 F 0h
Volatile write cache is not
present
Volatile Write Cache (VWC)
527-526 F 0h
Atomic write size for controller
during normal equals to 512B
Atomic Write Unit Normal (AWUN)
529-528 F 0h
Indicates the atomic write size
for the controller during a power
fail condition equals 512B
Atomic Write Unit Power Fail (AWUPF)
530 X 0h
Not Supported
NVM Vendor Specific Command
Configuration (NVSCC)
703-531
Reserved
2047-704
Reserved
2079-
2048
V
Indicates the characteristics of
power state 0
Power State 0 Descriptor (PSD0)
2111-
2080
V
Indicates the characteristics of
power state 1
Power State 1 Descriptor (PSD1)
May 2015 Product Specification
332164-003US 33
Intel® Solid-State Drive DC P3500 Series
Bytes
F = Fixed
V = Variable
X = Both
Default
Value
Interpretation
Description
2143-
2112
V
Indicates the characteristics of
power state 2
Power State 2 Descriptor (PSD2)
2175-
2144
V
Indicates the characteristics of
power state 3
Power State 3 Descriptor (PSD3)
2207-
2176
V
Indicates the characteristics of
power state 4
Power State 4 Descriptor (PSD4)
2239-
2208
V
Indicates the characteristics of
power state 5
Power State 5 Descriptor (PSD5)
2271-
2240
V
Indicates the characteristics of
power state 6
Power State 6 Descriptor (PSD6)
2303-
2272
V
Indicates the characteristics of
power state 7
Power State 7 Descriptor (PSD7)
2335-
2304
V
Indicates the characteristics of
power state 8
Power State 8 Descriptor (PSD8)
2367-
2336
V
Indicates the characteristics of
power state 9
Power State 9 Descriptor (PSD9)
2399-
2368
V
Indicates the characteristics of
power state 10
Power State 10 Descriptor (PSD10)
2431-
2400
V
Indicates the characteristics of
power state 11
Power State 11 Descriptor (PSD11)
2463-
2432
V
Indicates the characteristics of
power state 12
Power State 12 Descriptor (PSD12)
2495-
2464
V
Indicates the characteristics of
power state 13
Power State 13 Descriptor (PSD13)
2527-
2496
V
Indicates the characteristics of
power state 14
Power State 14 Descriptor (PSD14)
2559-
2528
V
Indicates the characteristics of
power state 15
Power State 15 Descriptor (PSD15)
2591-
2560
V
Indicates the characteristics of
power state 16
Power State 16 Descriptor (PSD16)
2623-
2592
V
Indicates the characteristics of
power state 17
Power State 17 Descriptor (PSD17)
2655-
2624
V
Indicates the characteristics of
power state 18
Power State 18 Descriptor (PSD18)
2687-
2656
V
Indicates the characteristics of
power state 19
Power State 19 Descriptor (PSD19)
2719-
2688
V
Indicates the characteristics of
power state 20
Power State 20 Descriptor (PSD20)
2751-
2720
V
Indicates the characteristics of
power state 21
Power State 21 Descriptor (PSD21)
Product Specification May 2015
34 332164-003US
Intel® Solid-State Drive DC P3500 Series
Bytes
F = Fixed
V = Variable
X = Both
Default
Value
Interpretation
Description
2783-
2752
V
Indicates the characteristics of
power state 22
Power State 22 Descriptor (PSD22)
2815-
2784
V
Indicates the characteristics of
power state 23
Power State 23 Descriptor (PSD23)
2847-
2816
V
Indicates the characteristics of
power state 24
Power State 24 Descriptor (PSD24)
2879-
2848
V
Indicates the characteristics of
power state 25
Power State 25 Descriptor (PSD25)
2911-
2880
V
Indicates the characteristics of
power state 26
Power State 26 Descriptor (PSD26)
2943-
2912
V
Indicates the characteristics of
power state 27
Power State 27 Descriptor (PSD27)
2975-
2944
V
Indicates the characteristics of
power state 28
Power State 28 Descriptor (PSD28)
3007-
2976
V
Indicates the characteristics of
power state 29
Power State 29 Descriptor (PSD29)
3039-
3008
V
Indicates the characteristics of
power state 30
Power State 30 Descriptor (PSD30)
3071-
3040
V
Indicates the characteristics of
power state 31
Power State 31 Descriptor (PSD31)
3075 F 05h
Data striped at 128 KB, value
shown is reported as 2^
(CAP.MPSMIN)
Internal stripe size
3095-
3076
V
Varies
Shows healthy status or error
code
Health indicator
3096
V
Varies
Reads current negotiated PCIe*
link speed, as reported by PXLS
register (PXCAP + 12h), bits[3:0]
Current PCIe* Link Speed field (CLS)
3097
V
Varies
Reads current negotiated PCIe*
Link Width as reported by PXLS
register (PXCAP + 12h), bits[9:4]
Negotiated Link Width (NLW)
3107-
3100
V
Varies
Bootloader Version
Bootloader Version reported by the drive
3109-
3108
F
0x8086
Company Vendor Identifier
Vendor identifier assigned by PCI-SIG
(Intel)
3111-
3110
F
0x0953
Device Identifier
Device identifier assigned by PCI-SIG
(Intel)
4095-
3112
V
NA
Range of bytes is allocated for
vendor specific usage
Vendor Specific (VS)
NOTES:
F = Fixed. The content of the word is fixed and does not change. For removable media devices, these values may change when
media is removed or changed.
V = Variable. The state of at least one bit in a word is variable and may change depending on the state of the device or the
commands executed by the device.
X = F or V. The content of the word may be fixed or variable.
May 2015 Product Specification
332164-003US 35
Bytes
F = Fixed
V = Variable
X = Both
Default
Value
Interpretation
Description
255-125
Reserved
124-120 F
0h
Indicates the relative write
latency associated with this
power state
Relative Write Latency (RWL)
119-117
Reserved
116-112 F 0h
Indicates the relative write
throughput associated with this
power state
Relative Write Throughput (RWT)
111-109
Reserved
108-104 F 0h
Indicates the relative read
latency associated with this
power state
Relative Read Latency (RRL)
103-101
Reserved
100-96 F 0h
Indicates the relative read
throughput associated with this
power state.
Relative Read Throughput (RRT)
95-64 F 0h
Indicates the maximum exit
latency in microseconds
associated with exiting this
power state.
Exit Latency (EXLAT)
63-32 F 0h
Indicates the maximum entry
latency in microseconds
associated with entering this
power state
Entry Latency (ENLAT)
31-16
Reserved
15-00
F
09C4h
Indicates the maximum power
consumed by the NVM
subsystem in this power state.
The power in Watts is equal to
the value in this field multiplied
by 0.01
Maximum Power (MP)
Table 30: Power State Descriptor
Intel® Solid-State Drive DC P3500 Series
NOTES:
F = Fixed. The content of the word is fixed and does not change. For removable media devices, these values may change when
media is removed or changed.
V = Variable. The state of at least one bit in a word is variable and may change depending on the state of the device or the
commands executed by the device.
X = F or V. The content of the word may be fixed or variable.
Product Specification May 2015
36 332164-003US
Intel® Solid-State Drive DC P3500 Series
Bytes
F = Fixed
V = Variable
X = Both
Default
Value
Interpretation
Description
7-0 V varies
Indicates the total size of the
namespace in logical blocks.
Namespace Size (NSZE)
15-8 V varies
Indicates the maximum number
of logical blocks that may be
allocated in the namespace at any
point in time
Namespace Capacity (NCAP)
23-16
V
varies
Indicates the current number of
logical blocks allocated in the
namespace
Namespace Utilization (NUSE)
24 F 00h
Indicates thin provisioning is not
supported
Namespace Features (NSFEAT)
25 F 06h
Defines the number of supported
LBA size and metadata size
combinations supported by the
namespace
Number of LBA Formats (NLBAF)
26 V 00h
Indicates metadata transferred
with the extended data LBA or in
separate buffer
Formatted LBA Size (FLBAS)
27 F 03h
Indicates support for metadata
transferred with the extended
data LBA and in separate buffer –
both are supported
Metadata Capabilities (MC)
28 V 11h
Indicates PI supports Type 1,2,3
with PI transferred as the first 8
bytes
End-to-end Data Protection Capabilities
(DPC)
29 X 00h
Indicates type settings for the
namespace
End-to-end Data Protection Type Settings
(DPS)
127-30
Reserved
131-128
V
MS:0,
LBADS:9,
RP:2
Indicates the LBA format 0 that is
supported by the controller
LBA Format 0 Support (LBAF0)
135-132
V
MS:8,
LBADS:9,
RP:2
Indicates the LBA format 1 that is
supported by the controller
LBA Format 1 Support (LBAF1)
139-136
V
MS:16,
LBADS:9,
RP:2
Indicates the LBA format 2 that is
supported by the controller
LBA Format 2 Support (LBAF2)
143-140
V
MS:0,
LBADS:12,
RP:0
Indicates the LBA format 3 that is
supported by the controller
LBA Format 3 Support (LBAF3)
Table 31: Identify Namespace
May 2015 Product Specification
332164-003US 37
Intel® Solid-State Drive DC P3500 Series
Bytes
F = Fixed
V = Variable
X = Both
Default
Value
Interpretation
Description
147-144
V
MS:8,
LBADS:12,
RP:0
Indicates the LBA format 4 that is
supported by the controller
LBA Format 4 Support (LBAF4)
151-148
V
MS:64,
LBADS:12,
RP:0
Indicates the LBA format 5 that is
supported by the controller
LBA Format 5 Support (LBAF5)
155-152
V
MS:128,
LBADS:12,
RP:0
Indicates the LBA format 6 that is
supported by the controller
LBA Format 6 Support (LBAF6)
159-156
Not
supported
Indicates the LBA format 7 that is
supported by the controller
LBA Format 7 Support (LBAF7)
163-160
Not
supported
Indicates the LBA format 8 that is
supported by the controller
LBA Format 8 Support (LBAF8)
167-164
Not
supported
Indicates the LBA format 9 that is
supported by the controller
LBA Format 9 Support (LBAF9)
171-168
Not
supported
Indicates the LBA format 10 that
is supported by the controller
LBA Format 10 Support (LBAF10)
175-172
Not
supported
Indicates the LBA format 11 that
is supported by the controller
LBA Format 11 Support (LBAF11)
179-176
Not
supported
Indicates the LBA format 12 that
is supported by the controller
LBA Format 12 Support (LBAF12)
183-180
Not
supported
Indicates the LBA format 13 that
is supported by the controller
LBA Format 13 Support (LBAF13)
187-184
Not
supported
Indicates the LBA format 14 that
is supported by the controller
LBA Format 14 Support (LBAF14)
191-188
Not
supported
Indicates the LBA format 15 that
is supported by the controller
LBA Format 15 Support (LBAF15)
383-192
Not
supported
Reserved
4095-384
Not
supported
Range of bytes is allocated for
vendor specific usage
Vendor Specific (VS)
NOTES:
F = Fixed. The content of the word is fixed and does not change. For removable media devices, these values may change when
media is removed or changed.
V = Variable. The state of at least one bit in a word is variable and may change depending on the state of the device or the
commands executed by the device.
X = F or V. The content of the word may be fixed or variable
Product Specification May 2015
38 332164-003US
Intel® Solid-State Drive DC P3500 Series
Bytes
F = Fixed
V = Variable
X = Both
Default
Value
Interpretation
Description
31-26
Reserved
25-24
V
Varies (2,0)
Relative Performance ranging
from “best” to “degraded”
Relative Performance (RP)
23-16
V
Varies (9
and 12)
Indicates the LBA data size
supported. The value is reported
in terms of a power of two (2^n)
LBA Data Size (LBADS)
15-00
V
Varies (0, 8,
16,64, 128)
Indicates the number of
metadata bytes provided per LBA
based on the LBA Data Size
indicated.
Metadata Size (MS)
Table 32: LBA Format Data Structure
NOTES:
F = Fixed. The content of the word is fixed and does not change. For removable media devices, these values may change when
media is removed or changed.
V = Variable. The state of at least one bit in a word is variable and may change depending on the state of the device or the
commands executed by the device.
X = F or V. The content of the word may be fixed or variable.
§
May 2015 Product Specification
332164-003US 39
Intel® Solid-State Drive DC P3500 Series
Address
# Bytes
Function
Programming
Value
Byte
Description
0
3
Class Code
02h
0
Device type and Programming Interface
08h 1 01h
2
3 2
ID
86h
3
PCI-SIG Vendor ID
80h
4
5
20
Varies
5-24
Serial Number
25 40
Varies
25-64
Model Number
65
1
PCIe Port0
Capabilities
03h
65
Maximum Link Speed
66 1 04h
66
Maximum Link Width
67
1
PCIe Port1
Capabilities
03h
67
Maximum Link Speed
68 1 04h
68
Maximum Link Width
69
1
Initial Power
Requirements
0Ah
69
12V Power rail initial power requirement
(W)
70
2
Reserved
00h
70-71
72
1
Maximum
Power
Requirements
19h
72
12V Power rail maximum power
requirement (W)
73
2
Reserved
00h
73-74
75
2
Capability List
Pointer
50h
75
16b address pointer to start of
capability list
Addr (Hex)
00
01
02
03
04
05
06
07
08
09 A B
50
A2
00
00
00
00
36
00
00
varies
varies
varies
varies
Description
Capability ID
(temp)
Next
Capability
(none)
Sensor
Type
SMBUS
address
Reserved
Warning
Threshold
Over
Temperature
Appendix B Vital Data Structure
Table 33: Vital Product Data Structure (VPD)
Table 34: Capability List Pointer (Out of Band Temperature Sensor)
Product Specification May 2015
40 332164-003US
§
Intel® Solid-State Drive DC P3500 Series
Binary
Hex
Temperature
1 1100 1001 0000
1C90
-55° C
1 1100 1110 0000
1CE0
-50° C
1 1110 0111 0000
1E70
-25° C
1 1111 1111 1111
1FFFF
-0.0625° C
0 0000 0000 0000
000
0° C
0 0000 0000 0001
001
0.0625° C
0 0001 1001 0000
190
25° C
0 0011 0010 0000
320
50° C
0 0111 1101 0000
7D0
55° C
Appendix C Out of Band Temperature
Sensor Read Out
Register 0x05 on address 0x1B contains the temperature information for the latest readout. Measured temperature
is captured by bit 12 to bit 0. Data format is two’s complement. Bit12 represents sign value, bit11 presents 128° C
and bit0 represents 0.0625° C. Following table gives an example of the read out.
Table 35: Register 0x05 read out format
May 2015 Product Specification
332164-003US 41
§
Intel® Solid-State Drive DC P3500 Series
ID Name
Description
Add-in
Card
2.5” FF
PCIe
Register
Location
Identify
Controller
Location
Vital Product Data
Location
Vendor ID (VID)
Vendor ID assigned
by PCI-SIG
0x8086
0x8086
PCI Header
Offset 00h
(bits 15:00)
Bytes 01:00h
Address 3, (size 2B)
Device ID (DID)
Device ID assigned
by vendor
0x0953
0x0953
PCI Header
Offset 00h
(bits 31:16)
NA
NA
Subsystem
Vendor ID
Indicates Subsystem vendor ID
0x8086
0x8086
PCI Header
Offset 2Ch
(bits 15:00)
Bytes 03:02h
NA
Subsystem ID
Sub-system
identifier
0x3704
0x3705
PCI Header
Offset 2Ch
(bits 31:16)
NA
NA
Appendix D Appendix D PCIe ID
Table 36: PCIe ID
§
Product Specification May 2015
42 332164-003US
Intel® Solid-State Drive DC P3500 Series
Appendix E Appendix E SCSI Command
Translation
Following SCSI commands are supported:
Read 6,10,12,16
Inquiry
Mode Sense 6,10
Mode Select 6.10
Log Sense
Read Capacity 10,16
Report LUNs
Request Sense
Start Stop Unit
Test Unit Ready
Write Buffer
Unmap
Note: Refer to NVM Express: SCSI translation reference doc under nvmexpress.org
§
May 2015 Product Specification
332164-003US 43
Intel® Solid-State Drive DC P3500 Series
LED
Description
Blink Behavior
LED 1( Amber)
Shows IO activity
Blinks at the rate of
250msec high, 250msec
low with IO activity
LED 2 (Red)
Drive fail indicator
Solid red if drive is in
disabled logical mode
LED 3 (Yellow)
Drive pre-fail indicator
Solid yellow if any of the
critical warnings in log
page 0x02 is triggered
LED 4 (Green)
Drive health indicator
Solid green when drive is
healthy
Appendix F Appendix F Add-in Card LED
Decoder
Table 37: LED Functionality
Figure A-1 LED Location
Note: 2.5-inch Form factor does not contain LEDs.
§
Product Specification May 2015
44 332164-003US
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.