Intel SR1550AL, SR1550ALSAS User Manual

4.64 Mb
Loading...

Intel® Server System SR1550AL/

SR1550ALSAS User’s Guide

A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products

Intel Order Number D31972-002

Disclaimer

Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.

Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.

Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

* Other names and brands may be claimed as the property of others.

Copyright © 2006, Intel Corporation. All Rights Reserved

ii

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

iii

§

iv

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Preface

About this Manual

Thank you for purchasing and using the Intel® Server System SR1550AL.

This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and step by step instructions on how to add and replace components on the server system. For the latest version of this manual, see http:// support.intel.com/support/motherboards/server/chassis/SR1550/.

Manual Organization

Chapter 1 provides a list of reference resources. In this chapter you will find a list of technical documents that give additional details on the Intel® Server System SR1550AL, and the location where they can be found.

Chapter 2 provides a brief overview of the server system. In this chapter, you will find a list of the server system features, illustrations of the product, and product diagrams to help you identify components and their locations.

Chapter 3 provides instructions on using the utilities that are shipped with the board or that may be required to update the system. This includes how to navigate through the BIOS Setup screens, how to perform a BIOS update, and how to reset the password or CMOS. Information about the specific BIOS settings and screens is available in the Intel® 5000 Series Chipsets Server Board Family Datasheet. See “Server System References” for a link to the Intel® 5000 Series Chipsets Server Board Family Datasheet.

Chapter 4 provides instructions on adding and replacing components. Use this chapter for step-by-step instructions and diagrams for installing or replacing components such as the fans, power supply, drives, and other components.

At the back of this manual, you will find technical specifications, regulatory information, "getting help" information, and the warranty.

Product Contents

The Intel® Server System SR1550AL ships with the Intel® Server Board S5000PAL. For further information, see the Intel® Server Board S5000PAL User’s Guide.

Intel® Server System SR1550AL Contents

Your Intel® Server System SR1550AL ships with the following items:

Intel® Server Board S5000PAL, installed in the server system

One 650 W power supply module, installed in the server system

A box of hardware components, referred to below as the "hardware box"

Full and low profile riser, installed in the server system

Optical drive tray assembly

Bridge board, installed in the server system

Fan cable, installed in the server system

Chassis intrusion switch, integrated into the server system riser

Attention document, in the server system product box

Quick Start User's Guide, in the server system product box

Two screws for installing the optical drive component, in the hardware box

Rack handles, in the hardware box

USB cable

Peripheral bay filler panel, installed in the server system

Mini control panel, installed in the server system

Active or passive mid-plane, installed in the server system

vi

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Safety Information

Important Safety Instructions

Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm.

Wichtige Sicherheitshinweise

Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel® Deployment Toolkit 2.0 CD oder unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.

Consignes de sécurité

Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel® Deployment Toolkit 2.0 CD ou bien rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.

Instrucciones de seguridad importantes

Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel® Deployment Toolkit 2.0 CD y/o en http://support.intel.com/ support/motherboards/server/sb/cs-010770.htm.

/ http://support.intel.com/support/motherboards/server/sb/CS-010770.htm Intel Server Boards and Server Chassis Safety Information Intel

viii

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Warnings

Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.

System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.

Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.

Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.

ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.

Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board.

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

ix

x

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

List of Figures

Figure 1. Intel® Integrated Server System SR1550AL ..............................................................

3

Figure 2. ChassisComponents ..................................................................................................

6

Figure 3. Server Board Connector and Component Locations .................................................

7

Figure 4. BIOS Select Jumper...................................................................................................

8

Figure 5. Recovery Jumpers .....................................................................................................

9

Figure 6. Light Guided Diagnostic LEDs .................................................................................

10

Figure 7. Back Panel Connectors............................................................................................

11

Figure 8. Passive SATA Mid-Plane Components....................................................................

13

Figure 9. Active SAS/SATA Mid-Plane Components ..............................................................

14

Figure 10. Mini Control Panel..................................................................................................

15

Figure 11. Standard Control Panel..........................................................................................

17

Figure 12. Intel® Local Control Panel......................................................................................

18

Figure 13. Front Panel Features and Peripherals ...................................................................

19

Figure 14. Front Bezel Supporting the Standard Control Panel ..............................................

24

Figure 15. Front Bezel Supporting the Intel® Local Control Panel ..........................................

24

Figure 16. Front Bezel Supporting the Mini Control Panel ......................................................

25

Figure 17. Removing the Front Bezel......................................................................................

25

Figure 18. Installing the Front Bezel........................................................................................

26

Figure 19. Removing the Server System Cover......................................................................

27

Figure 20. Installing the Server System Cover........................................................................

27

Figure 21. Removing the Processor Air Duct ..........................................................................

28

Figure 22. Removing the Processor 2 Air Dam (Optional - only if two processors are installed).

29

 

Figure 23. Installing the Processor Air Duct ............................................................................

29

Figure 24. Installing the Memory .............................................................................................

30

Figure 25. Lifting the Processor Socket Handle ......................................................................

32

Figure 26. Installing the Processor..........................................................................................

32

Figure 27. Removing the Socket Cover ..................................................................................

33

Figure 28. Installing the Heat Sink ..........................................................................................

33

Figure 29. Removing Hot-swap Disk Carrier from the Server System ....................................

35

Figure 30. Installing Hard Drive into Carrier ............................................................................

36

Figure 31. Install Drive Assemby into the Server System .......................................................

36

Figure 32. Installing the Interposer Board to the Optical Drive................................................

38

Figure 33. Installing an Optical Drive Assembly into the Server System ................................

39

Figure 34. Removing the Slimline Optical Drive Assembly from the Server System ..............

40

Figure 35. Removing PCI Riser Assembly from the Server System .......................................

41

Figure 36. Installing PCI Riser Assembly into the Server System...........................................

42

Figure 37. Removing the PCIe* Riser Card from the Server System......................................

44

Figure 38. Installing the PCI-X* Riser Card into the Server System .......................................

45

Figure 39. Installing an Add-In Card........................................................................................

46

Figure 40. Removing an Add-In Card......................................................................................

47

Figure 41. Installing the I/O Expansion Module(s) to the Server Board ..................................

48

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

xi

Figure 42.

Removing the I/O Expansion Module(s) from the Server Board............................

49

Figure 43.

Installing the Intel® RMM and the Intel® RMM NIC Module to the Server System

50

Figure 44. Removing the Intel® RMM and the Intel® RMM NIC Module from the Server System 51

Figure 45. Removing the Mid-plane from the Server System .................................................

53

Figure 46. Installing the Mid-plane Board into the Server System..........................................

54

Figure 47. Installing the RAID Activation Key and the RAID Mini DIMM ................................

55

Figure 48. Removing the Intel® Integrated RAID Activation Key and the RAID Mini DIMM ...

56

Figure 49. Installing the RAID Battery Backup Unit ................................................................

57

Figure 50. Removing the RAID Battery Backup Unit ..............................................................

58

Figure 51. Installing the Server Board ....................................................................................

59

Figure 52. Removing the Server Board ..................................................................................

61

Figure 53. Replacing the Backup Battery ...............................................................................

63

Figure 54. Removing Power Supply Filler Panel from the Server System..............................

64

Figure 55. Removing Power Supply Module from the Server System....................................

65

Figure 56. Installing Power Supply Module into the Server System .......................................

65

Figure 57. Removing the Power Distribution Board Cover .....................................................

66

Figure 58. Installing the Power Distribution Board Cover .......................................................

67

Figure 59. Removing Mini Control Panel Module from the Server System.............................

68

Figure 60. Installing Control Panel Module into the Server System........................................

69

Figure 61. Installing Mini Control Panel Filler into the Server System ....................................

69

Figure 62. Removing the Standard Control Panel from the Server System ...........................

70

Figure 63. Removing Mini Control Panel Filler from the Server System.................................

71

Figure 64. Installing Mini Control Panel into the Server System.............................................

71

Figure 65. Removing a System Fan .......................................................................................

72

Figure 66. Installing a System Fan .........................................................................................

73

Figure 67. Removing the Fan Pack ........................................................................................

74

Figure 68. Installing the Fan Pack ..........................................................................................

75

Figure 69. Installing the Rack Handle .....................................................................................

76

Figure 70. Removing the Rack Handle ...................................................................................

77

Figure 71. Clear Password Jumper ........................................................................................

83

Figure 72. Clear CMOS Jumper .............................................................................................

84

Figure 73. System Cable Routing ...........................................................................................

85

Figure 74. SATA Cable Installation.........................................................................................

86

Figure 75. Diagnostic LED Placement Diagram ...................................................................

106

xii

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Table of Contents

Preface .........................................................................................................................

v

About this Manual ..................................................................................................................

v

Manual Organization ..............................................................................................................

v

Product Contents ..................................................................................................................

vi

Intel® Server System SR1550AL Contents ..................................................................

vi

Safety Information ....................................................................................................

vii

Important Safety Instructions ...............................................................................................

vii

Wichtige Sicherheitshinweise ..............................................................................................

vii

Consignes de sécurité .........................................................................................................

vii

Instrucciones de seguridad importantes ..............................................................................

vii

Chapter 1: Server System References .....................................................................

1

Chapter 2: Server System Features ..........................................................................

3

Chassis Component Identification .........................................................................................

6

Internal Components .....................................................................................................

6

Configuration Jumpers ...........................................................................................................

8

RAID Support .......................................................................................................................

12

Mini Control Panel .......................................................................................................

15

Standard Control Panel ...............................................................................................

16

Intel® Local Control Panel ...........................................................................................

17

Bezels ..........................................................................................................................

18

Front Panel Features and Peripheral Devices .....................................................................

19

Hard Disk Drives ..........................................................................................................

19

Slimline Optical Drive Carrier ......................................................................................

19

Advanced Management Options .........................................................................................

20

Intel® Remote Management Module ...........................................................................

20

Chapter 3: Hardware Installations and Upgrades .................................................

21

Before You Begin .................................................................................................................

21

Tools and Supplies Needed ........................................................................................

21

System References .....................................................................................................

21

Removing and Installing from a Rack ..................................................................................

21

Fixed Bracket Rack Mount Removal ...........................................................................

21

Fixed Bracket Rack Mount Installation ........................................................................

22

Basic Rail Rack Mount Removal .................................................................................

23

Basic Rail Rack Mount Installation ..............................................................................

23

Tool-less Rail Rack Mount Servicing ...........................................................................

24

Removing and Installing the Front Bezel .............................................................................

24

Removing the Front Bezel ...........................................................................................

25

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

xiii

Installing the Front Bezel .............................................................................................

26

Removing and Installing the Chassis Cover ........................................................................

26

Removing the Chassis Cover ......................................................................................

26

Installing the Server System Cover .............................................................................

27

Removing and Installing the Processor Air Duct .................................................................

28

Removing the Processor Air Duct ...............................................................................

28

Installing the Processor Air Duct .................................................................................

29

Installing and Removing Memory ........................................................................................

30

Installing DIMMs ..........................................................................................................

30

Removing DIMMs ........................................................................................................

31

Installing the Processor ...............................................................................................

32

Installing the Heat Sink(s) ...........................................................................................

33

Removing a Processor ................................................................................................

34

Installing and Removing a Hot-swap Hard Drive .................................................................

34

Installing a SAS/SATA Hot-swap Hard Disk Drive ......................................................

35

Removing a SAS/SATA Hot-swap Hard Disk Drive ....................................................

37

Installing or Removing a Slimline Optical Drive or Internal USB Floppy .............................

37

Installing a Slimline Optical Drive or Internal USB Floppy ..........................................

38

Removing a Slimline Optical Drive or Internal USB Floppy ........................................

39

Installing and Removing the PCI Riser Assembly ...............................................................

40

Removing the PCI Riser Assembly .............................................................................

40

Installing the PCI Riser Assembly ...............................................................................

41

Replacing the PCI Express* Riser Card with the PCI-X* Riser Card ..................................

43

Removing the PCI Express* Riser Card .....................................................................

43

Installing the PCI-X* Riser Card ..................................................................................

45

Installing and Removing a PCI Add-in Card ........................................................................

46

Installing a PCI Add-in Card ........................................................................................

46

Removing a PCI Add-in Card ......................................................................................

47

Installing and Removing the I/O Expansion Module(s) .......................................................

48

Installing the I/O Expansion Module(s) .......................................................................

48

Removing the I/O Expansion Module(s) .....................................................................

49

Installing and Removing the Intel® Remote Management Module and the Intel® RMM NIC

..

50

 

Installing the Intel® RMM and Intel® RMM NIC ...........................................................

50

Removing the Intel® RMM and Intel® RMM NIC .........................................................

51

Replacing the Mid-plane Board ...........................................................................................

52

Removing the Mid-plane Board ...................................................................................

52

Installing the Mid-plane Board .....................................................................................

53

Installing and Removing the Intel® Integrated RAID Activation Key and the RAID Mini DIMM

55

 

Installing the Intel® Integrated RAID Activation Key and the RAID Mini DIMM ...........

55

Removing the Intel® Integrated RAID Activation Key and the RAID Mini DIMM .........

56

Installing and Removing the RAID Battery Backup Unit (BBU) ...........................................

57

Installing the RAID Battery Backup Unit ......................................................................

57

xiv

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Removing the RAID Battery Backup Unit ....................................................................

58

Installing and Removing the Server Board ..........................................................................

59

Installing the Server Board ..........................................................................................

59

Removing the Server Board ........................................................................................

60

Replacing the Backup Battery .............................................................................................

62

Replacing or Adding a Power Supply ..................................................................................

64

Replacing the Power Distribution Module ............................................................................

66

Replacing the Control Panel ................................................................................................

68

Reinstalling the Mini Control Panel ......................................................................................

70

Reinstalling the Mini Control Panel ..............................................................................

70

Removing and Installing the Fan Pack ................................................................................

73

Removing the Fan Pack ..............................................................................................

73

Installing the Fan Pack ................................................................................................

75

Installing and Removing the Rack Handles .........................................................................

76

Installing the Rack Handles .........................................................................................

76

Removing the Rack Handles .......................................................................................

76

Chapter 4: Server Utilities ........................................................................................

79

Using the BIOS Setup Utility ................................................................................................

79

Starting Setup ..............................................................................................................

79

If You Cannot Access Setup ........................................................................................

79

Setup Menus ...............................................................................................................

79

Upgrading the BIOS .............................................................................................................

81

Preparing for the Upgrade ...........................................................................................

81

Upgrading the BIOS ....................................................................................................

82

Clearing the Password .........................................................................................................

82

Clearing the CMOS ..............................................................................................................

83

Appendix A: Technical Reference ..........................................................................

85

Cable Routing ......................................................................................................................

85

750W Single Power Supply Input Voltages .........................................................................

86

750W Single Power Supply Output Voltages ......................................................................

87

System Environmental Specifications ..................................................................................

88

Appendix B: Troubleshooting .................................................................................

89

Resetting the System ...........................................................................................................

89

Problems following Initial System Installation ......................................................................

90

First Steps Checklist ....................................................................................................

90

Hardware Diagnostic Testing ...............................................................................................

91

Verifying Proper Operation of Key System Lights .......................................................

91

Confirming Loading of the Operating System ..............................................................

91

Specific Problems and Corrective Actions ...........................................................................

92

Power Light Does Not Light .........................................................................................

92

No Characters Appear on Screen ...............................................................................

93

Characters Are Distorted or Incorrect ..........................................................................

93

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

xv

System Cooling Fans Do Not Rotate Properly ............................................................

94

Drive Activity Light Does Not Light ..............................................................................

94

CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light ..............................

94

Cannot Connect to a Server ........................................................................................

95

Problems with Network ...............................................................................................

95

System Boots when Installing PCI Card .....................................................................

96

Problems with Newly Installed Application Software ...................................................

96

Problems with Application Software that Ran Correctly Earlier ..................................

96

Devices are not Recognized under Device Manager (Microsoft* Windows* Operating

System) ...........................................................................................................

97

Hard Drive(s) are not Recognized ...............................................................................

97

Bootable CD-ROM Disk Is Not Detected ....................................................................

97

LED Information ..........................................................................................................

98

BIOS POST Beep Codes ............................................................................................

98

Appendix C: Intel® Server Issue Report Form .....................................................

101

Appendix D: LED Decoder .....................................................................................

105

Appendix E: Getting Help .......................................................................................

111

World Wide Web ...............................................................................................................

111

Telephone .........................................................................................................................

111

Appendix F: Regulatory and Compliance Information ........................................

115

Product Regulatory Compliance ........................................................................................

115

Product Safety Compliance .......................................................................................

115

Product EMC Compliance - Class A Compliance .....................................................

116

Certifications / Registrations / Declarations ..............................................................

117

Product Regulatory Compliance Markings ................................................................

117

Electromagnetic Compatibility Notices ..............................................................................

118

FCC Verification Statement (USA) ............................................................................

118

Industry Canada (ICES-003) .....................................................................................

119

Europe (CE Declaration of Conformity) .....................................................................

120

VCCI (Japan) ............................................................................................................

120

BSMI (Taiwan) ..........................................................................................................

120

Korean Compliance (RRL) ........................................................................................

120

CNCA (CCC-China) ..................................................................................................

121

Regulated Specified Components .............................................................................

121

Restriction of Hazardous Substances (RoHS) Compliance ..............................................

122

End-of-Life / Product Recycling .........................................................................................

122

Appendix G: Warranty ............................................................................................

123

Limited Warranty for Intel® Chassis Subassembly Products ............................................

123

Appendix H: Installation/Assembly Safety Instructions .....................................

127

English ...............................................................................................................................

127

Deutsch .............................................................................................................................

129

xvi

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Français .............................................................................................................................

131

Español ..............................................................................................................................

133

Italiano ...............................................................................................................................

136

Appendix I: Safety Information .............................................................................

139

English ...............................................................................................................................

139

Server Safety Information ..........................................................................................

139

Safety Warnings and Cautions ..................................................................................

139

Intended Application Uses .........................................................................................

140

Site Selection .............................................................................................................

140

Equipment Handling Practices ..................................................................................

140

Power and Electrical Warnings ..................................................................................

141

System Access Warnings ..........................................................................................

142

Rack Mount Warnings ...............................................................................................

142

Electrostatic Discharge (ESD) ...................................................................................

143

Other Hazards ...........................................................................................................

143

Deutsch ..............................................................................................................................

144

Sicherheitshinweise für den Server ...........................................................................

144

Sicherheitshinweise und Vorsichtsmaßnahmen ........................................................

144

Zielbenutzer der Anwendung .....................................................................................

145

Standortauswahl ........................................................................................................

145

Handhabung von Geräten .........................................................................................

145

Warnungen zu Netzspannung und Elektrizität ..........................................................

146

Warnhinweise für den Systemzugang .......................................................................

147

Warnhinweise für Racks ............................................................................................

147

Elektrostatische Entladungen (ESD) .........................................................................

148

Andere Gefahren .......................................................................................................

148

Français .............................................................................................................................

149

Consignes de securite sur le serveur ........................................................................

149

Séurité: avertissements et mises en garde ...............................................................

149

Domaines d’utilisation prévus ....................................................................................

150

Sélection d’un emplacement .....................................................................................

150

Pratiques de manipulation de l’équipement ...............................................................

151

Alimentation et avertissements en matiére d’électricité .............................................

151

Avertissements sur le cordon d’alimentation .............................................................

152

Avertissements sur l’accés au systéme .....................................................................

152

Avertissements sur le montage en rack ....................................................................

153

Décharges électrostatiques (ESD) ............................................................................

154

Autres risques ............................................................................................................

154

Périphériques laser ....................................................................................................

155

Español ..............................................................................................................................

155

Información de seguridad del servidor ......................................................................

155

Advertencias y precauciones sobre seguridad ..........................................................

155

Aplicaciones y usos previstos ....................................................................................

156

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

xvii

Seleccién de la ubicación ..........................................................................................

156

Manipulacién del equipo ...........................................................................................

157

Advertencias de alimentacién y eléctricas ................................................................

157

Advertencias sobre el cable de alimentación ............................................................

157

Advertencias el acceso al sistema ............................................................................

158

Advertencias sobre el montaje en bastidor ...............................................................

159

Descarga electrostática (ESD) ..................................................................................

159

Otros riesgos .............................................................................................................

160

xviii

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

List of Tables

Table 1. Server System References .........................................................................................

1

Table 2. Intel® Server System SR1550AL Feature Summary ...................................................

4

Table 3. NIC LED Descriptions ...............................................................................................

12

Table 4. Setup Menu Key Use ................................................................................................

80

Table 5. Power Supply Output Capability ................................................................................

87

Table 6.

System Environmental Specifications .......................................................................

88

Table 7.

Resetting the System ................................................................................................

89

Table 8.

LED Information ........................................................................................................

98

Table 9.

POST Error Beep Codes ...........................................................................................

98

Table 10.

Error Beep Codes Generated by Intel® Remote Management Module ..................

99

Table 11. POST Progress Code LED Example .....................................................................

105

Table 12.

Diagnostic LED POST Code Decoder ...................................................................

106

Table 13.

Product Regulatory Compliance Markings ............................................................

117

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

xix

xx

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

1 Server System References

If you need more information about this product or information about the accessories that can be used with this server chassis, use the following resources.

Table 1. Server System References

For this information or

Use this Document or Software

software

 

 

 

For in-depth technical

Intel® Server Chassis SR1550 Technical Product Specification

information about the

Found at:

server chassis, including

 

sub-system overviews

http://support.intel.com/support/motherboards/server/chassis/

and mechanical drawings

SR1550/

 

 

For in-depth technical

Intel® Server Board S5000PAL Technical Product Specification

information about the

Found:

server board, including

 

board layout, connector

http://support.intel.com/support/motherboards/server/S5000PAL/

pin-outs, timing

 

information, mechanical

 

drawings and LED

 

information

 

 

 

For basic BIOS settings

Intel® 5000 Series Chipsets Server Board Family Datasheet

and chipset information

Found:

 

 

http://support.intel.com/support/motherboards/server/S5000PAL/

 

 

For in-depth BIOS

Intel® S5000 Server Board Family Server BIOS External Product

information

Specification

 

Found: available to order by contacting your Intel field

 

representative; Intel reference number 19953

 

 

For in-depth firmware

ESB2 Baseboard Management Controller Core External Product

information on the

Specification for the Intel® S5000 Server Board Family

Baseboard Management

Found: available to order by contacting your Intel field

Controller (BMC)

representative; Intel reference number 19692.

 

 

 

For in-depth information

Intel® I/O Acceleration Technology Improves Intel Server Platform

on Intel® I/O Acceleration

Network Performance, Reliability, and Efficiency whitepaper

Technology

Found: available from your Intel field representative

 

 

 

If you just received this

Intel® Integrated Server System SR1550AL Quick Start User's

product and need to

Guide

install it

Found: in the product box

 

 

 

For virtual system tours

A link to the SMaRT Tool is available under "Other Resources" at

and interactive repair

the right side of the screen at

information

http://support.intel.com/support/motherboards/server/chassis/

 

 

SR1550

 

 

Table 1. Server System References

For this information or

Use this Document or Software

software

 

 

 

Accessories or other Intel

Spares and Configuration Guide

server products

Found: available from your Intel field representative or on the

 

 

Server Configurator Tool at http://indigo.intel.com/

 

serverconfiguratortool/default.aspx

 

 

Hardware (peripheral

Tested HardwareOperating Systems List

boards, adapter cards)

Found:

and operating systems

 

that have been tested with

http://support.intel.com/support/motherboards/server/S5000PAL/

this product

 

 

 

To make sure your system

Power Budget Tool

falls within the allowed

Found:

power budget

 

 

http://support.intel.com/support/motherboards/server/S5000PAL/

 

 

For software to manage

Intel® System Management Software

your Intel® server

Found:

 

 

http://support.intel.com/support/motherboards/server/S5000PAL/

 

 

For diagnostics test

Diagnostics

software

Found:

 

 

http://support.intel.com/support/motherboards/server/S5000PAL/

 

 

2

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

2 Server System Features

This chapter briefly describes the main features of the server system. This chapter provides a illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system.

TP02211

Figure 1. Intel® Integrated Server System SR1550AL

Table 2 summarizes the features of the server system.

Table 2. Intel® Server System SR1550AL Feature Summary

Feature

Description

 

 

Dimensions

1.700 inches (43.2mm) high

 

16.930 inches (430.0mm) wide

 

25.76 inches (654.4mm) deep

 

37pounds (16.8 kg) - base chassis weight

 

 

Server Board

Intel® Server Board S5000PAL

 

 

Processor

Support for up to two Dual-Core Intel® Xeon® processors 5000

 

sequence

 

 

Memory

Eight DIMM slots supporting stacked DDR2 533/667 MHz

 

FBDIMM memory

 

Support for up to 32 GB DDR2 533/667 MHz FBDIMM memory

 

 

Chipset

Intel® 5000P chipset, consisting of:

 

Intel® 5000P Memory Controller Hub (MCH)

 

Intel® 6321ESB I/O Controller Hub

Peripheral Interfaces

External connections:

 

Stacked PS/2* ports for keyboard and mouse

 

RJ45 Serial B port

 

Two RJ45 NIC connectors for 10/100/1000 Mb connections

 

Two USB 2.0 ports

 

Internal connections:

 

One USB port header, which supports two USB 2.0 ports

 

One DH10 Serial A header

 

Six Serial ATA 150 connectors with integrated RAID 0/1

 

support

 

One ATA-100 44-pin connector for optical drive support

 

SSI-compliant 24-pin control panel header

 

SSI-compliant 24-pin main power connector, supporting the

 

ATX-12V standard on the first 20 pins

 

 

I/O Controll

National Semiconductor* PC87427 controller

 

 

Video

On-board ATI* ES1000 video controller with 16 MB DDR SDRAM

 

 

LAN

Intel® 82563EB dual port controller for 10/100/1000 Mbit/sec

 

Ethernet LAN connectivity

 

 

Expansion Capabilities

One low profile riser slot supporting 1U PCI Express* riser

 

cards

 

One full height riser slot supporting 1U PCI-X* and PCI

 

Express* riser cards

 

 

Hard Drives

Up to eight 2.5 inch hot-swap SATA / SAS drives

 

 

4

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Table 2. Intel® Server System SR1550AL Feature Summary

Feature

Description

 

 

Peripherals

Slimline bay for IDE optical drive PCI riser card bracket

Control Panel (dependent

Standard control panel

on option selected)

Intel® Local Control Panel

 

Mini control panel

 

 

LEDs and displays

With standard control panel:

(dependent on option

NIC1 Activity

selected)

NIC2 Activity

 

 

Power / Sleep

 

System Status

 

System Identification

 

Hard Drive Activity

 

With Intel® Local Control Panel:

 

NIC1 Activity

 

NIC2 Activity

 

Power / Sleep

 

System Status

 

System Identification

 

Hard Drive Activity

 

LCD Display

 

 

Power Supply

Up to two 650W power supply modules

 

 

 

Fans

Six 4-pin fan headers supporting two processor fans, and four

 

 

system fans

 

Dedicated non-redundant power supply fan (one per module)

 

 

 

USB

One front panel USB port

 

One internal USB header providing two USB ports

 

 

System Management

Intel® System Management Software

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

5

Chassis Component Identification

This section helps you identify the components of your server system. If you are near the system, you can also use the Quick Reference Label provided on the inside of the chassis cover to assist in identifying components.

Internal Components

 

F

 

G

E

H

I

 

D

C

B

A

J

K

P

L

 

M

 

N

 

O

TP02212

A.

Rack Handle

I.

PCI Riser Assembly

 

 

 

 

B.

Slimline Optical Drive Bay (Optical Drive

J.

Processor Air Duct

 

Shown)

 

 

 

 

 

 

C.

SR1550ALSAS RAID Battery Pack

K.

Fan Assembly

 

(Optional)

 

 

 

 

 

 

D.

Power Distribution Board

L.

Bridge Board

 

 

 

 

E.

Power Supply Air Duct

M.

Mid-plane Board (Active Shown)

 

 

 

 

F.

Power Supply Filler (Second Power Supply

N.

Mini Control Panel Bay

 

if Installed)

 

 

 

 

 

 

G.

Power Supply Module

O.

Rack Handle

 

 

 

 

H.

Server Board

P.

Hard Drive Bays

 

 

 

 

Figure 2. ChassisComponents

6

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Server Board Connector and Component

Locations

 

 

 

A

B C D E F

G H I

 

 

 

 

QQ

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

PP

 

 

 

 

 

 

 

 

 

 

 

 

K

 

 

OO

 

 

 

 

L

 

 

NN

 

 

 

 

 

 

 

MM

 

 

 

 

 

 

 

LL

 

 

 

 

M

 

 

KK

 

 

 

 

 

 

 

 

 

 

 

 

 

JJ

 

 

 

 

 

 

 

II

 

 

 

 

N

 

 

HH

 

 

 

 

 

 

 

 

 

 

 

 

 

GG

 

 

 

 

 

 

 

FF

 

 

 

 

 

 

 

EE

 

 

 

 

 

 

 

DD

 

 

 

 

O

 

 

CC

 

 

 

 

 

 

 

BB

 

 

 

 

P

 

 

AA

 

 

 

 

 

 

 

 

 

 

 

 

 

Z

 

 

 

 

Q

 

 

 

Y X

W V U T S

R

 

 

 

 

 

 

 

 

TP02071

 

Figure 3. Server Board Connector and Component Locations

A. BIOS Bank Select Jumper

B. Intel® 6321ESB IO Controller Hub

C. I/O Expansion Module Connector

D. POST Code Diagnostic LEDs

E. Intel® Adaptive Slot - Full Height

F. PCI Express* Riser Slot - Low

 

 

 

 

 

 

 

Profile

G.

System Identification LED - Blue

H. Back Panel I/O Ports

 

I.

Status LED - Green/Amber

J. Serial B Configuration Jumper

K. System Fan 4 Header

 

L.

System Fan 3Header

M.

DIMM Sockets

N.

Intel® 5000P MCH

 

O.

Processor 1 Socket

P.

Processor 2 Socket

Q. Processor Fan 1 Header

 

R. Voltage Regulator Heat Sink

S. Processor Fan 2 Header

T.

Bridge Board Connector

 

U. ATA-100 Optical Drive Connector

 

 

 

 

 

 

 

(Power + IO)

V. System Fan 2 Header

W.

CPU Power Connector

 

X.

Main Power Connector

Y.

Battery

Z.

Power Supply Management

AA. Dual Port USB 2.0 Header

 

 

 

Connector

 

 

 

BB. System Fan 1 Header

CC. 24-pin SSI Control Panel

 

DD. SATA Port 0

 

 

 

Connector

 

 

 

EE. SATA Port 1

FF.

SATA Port 2

 

GG. SATA Port 3

HH. SATA Port 4

II.

SATA Port 5

 

JJ. SATA SW RAID 5 Activation Key

 

 

 

 

 

 

 

Connector

KK. Intel® Remote Management

LL.

System Recovery Jumpers

MM. Chassis Intrusion Switch Header

 

Module (RMM) Connector

 

 

 

 

 

 

NN.

3-pin IPMB Header

OO. Intel® Local Control Panel Header

PP.

Serial A Header

QQ. Intel® RMM NIC Connector

 

 

 

 

 

 

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

7

Configuration Jumpers

BIOS Select

J3H1

1-2: Force

Lower Bank

3

2-3: Normal Operation (Default)

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TP02087

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jumper Name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jumper Purpose

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIOS Select

If pins 1-2 are jumpered, the BIOS in the lower bank will be selected

 

on the next reset. These pins should be jumpered on 2-3 for normal

 

operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4. BIOS Select Jumper

8

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

 

 

BMC Force

 

 

Update Mode

2

 

Disable

Password

2

 

Enable

3

Reset

3

 

J1D2

 

J1D1

2

Clear 3 CMOS

J1D3

TP02080

Jumper Name

Jumper Purpose

 

 

CMOS Clear

If pins 2-3 are jumpered, the CMOS settings will be cleared on the

 

next reset. These pins should be jumpered on 1-2 for normal

 

operation.

 

 

Password Clear

If pins 2-3 are jumpered, administrator and user passwords will be

 

cleared on the next reset. These pins should be jumpered on 1-2 for

 

normal operation.

 

 

BMC Force Update Mode

If pins 2-3 are jumpered, BMC Force Update Mode is enabled.

 

These pins should be jumpered on 1-2 for normal operation.

 

 

 

Figure 5. Recovery Jumpers

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

9

Intel® Light Guided Diagnostics

The server board contains diagnostic LEDs to help you identify failed and failing components, and to help you identify the server from among several servers. Except for the ID LED, the status LED, and the 5V standby LED, the LEDs turn on (amber) only if a failure occurs.

N

A

 

 

 

B

 

 

 

 

 

 

C

 

 

 

 

POST

Code LEDs

D

E

F

G

 

H

 

I

J

 

K

 

 

 

DIMM A1

DIMM A2

DIMM B1

DIMM B2

DIMM C1

DIMM C2

DIMM D1

DIMM D2

L

M

Light Guided

Diagnostics

Legend

A through N

A.POST Code LEDs

B.ID LED

C.Status LED

D.DIMM A1 Fault

E.DIMM A2 Fault

F.DIMM B1 Fault

G.DIMM B2 Fault

H.DIMM C1 Fault

I.DIMM C2 Fault

J.DIMM D1 Fault

K.DIMM D2 Fault

L.CPU 1 Fault

M.CPU 2 Fault

N.5V Standby

CPU 2

CPU 1

Socket

Socket

AF000644

Figure 6. Light Guided Diagnostic LEDs

10

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Back Panel Connectors

A B C D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

M L K

J

I H

G

 

 

F

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TP02216

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.

Mouse

 

 

 

 

 

 

 

 

 

 

B.

Low Profile PCI Express* Add-in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Card Slot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C.

Full Height PCI Add-in Card Slot

D.

Power Supply Module 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E.

Power Supply Module 2 (Filler Panel

F.

Intel® Remote Management Module

 

 

 

 

 

 

 

Shown)

 

 

 

 

 

 

 

 

 

 

 

 

NIC (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G.

I/O Expansion Module (Optional)

H.

USB Port 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I.

USB Port 6

 

 

 

 

 

 

 

 

 

 

J.

Video

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.

NIC 2 (10/100/1000 Mb)

L. NIC 1 (10/100/1000 Mb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M.

RJ45 Serial B Connector

N.

Keyboard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 7. Back Panel Connectors

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

11

The NIC LEDs at the right and left of each NIC provide the following information.

Table 3. NIC LED Descriptions

LED

LED State

Description

 

 

 

Left

Off

No network connection

 

 

 

 

Solid Amber

Network connection in place

 

 

 

 

Blinking Amber

Transmit/receive activity

 

 

 

Right

Off

10 Mbps connection (if left LED is on or blinking)

 

 

 

 

Solid Amber

100 Mbps connection

 

 

 

 

Solid Green

1000 Mbps connection

 

 

 

RAID Support

The Intel® Server System SR1550AL provides an embedded SATA controller that supports both 1.5 and 3.0 Gbps data transfer rates. The Intel® Server System SR1550ALSAS provides SAS and SATA support. Both systems can be configured for RAID 0, 1, and 10.

The Intel® Server System SR1550AL can be configured for SW RAID 5 by using the Intel® RAID Activation Key AXXRAKSW5 accessory.

For information on configuring RAID, see the RAID software user’s guide that is included on the Intel® Server Deployment Toolkit 2.0 CD.

12

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

SAS/SATA Mid-Planes

The mid-plane serves as the primary interface between the server board, the hot-swap backplane, and the control panel. Two midplanes are offered for this system: a passive SATA only, and an active SAS/SATA. The following diagrams show the location for each connector found on the mid-planes.

B

A

I

H

C

D

3

2

0

1

 

 

 

7

6

5

 

4

 

 

F

G

E

TP02269

A.

Fan 2 Power

F.

Fan 6 Power

 

 

 

 

B.

Fan 1 Power

G.

HBA I2C Connector

 

 

 

 

C.

Thumbscrew

H.

Fan 4 Power

 

 

 

 

D.

Bridge Board Connector

I.

Fan 3 Power

 

 

 

 

E.

Mid-plane Power

 

 

 

 

 

 

Figure 8. Passive SATA Mid-Plane Components

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

13

 

B

C

A

 

 

D

 

 

E

F

 

K

 

 

 

J

I

 

 

 

 

G

 

 

 

H

 

 

 

TP02268

A.

Fan 2 Power

G.

RAID Battery Backup Unit Connector

B.

Fan 1 Power

H.

Mid-plane Power

C.

RAID Activation Key Connector

I.

Thumbscrew

D.

Bridge Board Connector

J.

Fan 4 Power

E.

Fan 6 Power

K.

Fan 3 Power

F.

Mini-DIMM Connector

 

 

Figure 9. Active SAS/SATA Mid-Plane Components

.

14

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Front of Server System

Mini Control Panel

The diagram below shows the features available on the mini control panel. The mini control panel is one of three required control options that can be selected. The other options are the standard control panel or the Intel® Local Control Panel. For instructions on installing the control panel, see “Replacing the Control Panel”.

A B C D

G F E

TP02215

Callout

Feature

Function

 

 

 

A.

System Identification

Solid blue indicates system identification is active.

 

LED

No light indicates system identification is not activated.

 

 

 

 

 

B.

System Status LED

Solid green indicates normal operation.

 

 

Blinking green indicates degraded performance.

 

 

Solid amber indicates a critical or non-recoverable condition.

 

 

Blinking amber indicates a non-critical condition.

 

 

No light indicates POST is running or the system is off.

 

 

 

C.

Power/Sleep LED

Continuous green light indicates the system has power applied to

 

 

it.

 

 

Blinking green indicates the system is in S1 sleep state.

 

 

No light indicates the power is off / is in ACPI S4 or S5 state.

 

 

 

D.

Power/Sleep Button

Powers on/off the system.

 

 

Puts the system in an ACPI sleep state.

 

 

 

E.

NMI Button

Puts the server in a halt-state for diagnostic purposes

 

 

 

F.

System Identification

Turns on/off the system identification LED.

 

Button

 

 

 

 

G.

USB 2.0 Port

Allows you to attach a USB component to the front of the system.

 

 

 

Figure 10. Mini Control Panel

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

15

Standard Control Panel

The diagram below shows the features available on the standard control panel. The standard control panel is one of two required control options that can be selected. The other option is the Intel® Local Control Panel. For instructions on installing the standard control panel, see “Replacing the Control Panel”.

A B C D E F G

H

I

 

 

L

K

J

 

 

 

 

TP02213

 

 

 

 

 

Callout

Feature

 

 

Function

 

 

 

A.

NIC 2 Activity LED

Continuous green light indicates a link between the system and

B.

NIC 1 Activity LED

the network to which it is connected.

 

 

 

 

Blinking green light indicates network activity.

 

 

 

 

 

C.

Power/Sleep Button

Powers on/off the system.

 

 

Puts the system in an ACPI sleep state.

 

 

 

D.

Power/Sleep LED

Continuous green light indicates the system has power applied to

 

 

it.

 

 

 

 

Blinking green indicates the system is in S1 sleep state.

 

 

No light indicates the power is off / is in ACPI S4 or S5 state.

 

 

 

E.

Hard Disk Drive

Random blinking green light indicates hard disk drive activity (SAS

 

Activity LED

or SATA).

 

 

 

 

No light indicates no hard disk drive activity.

 

 

 

F.

System Status LED

Solid green indicates normal operation.

 

 

Blinking green indicates degraded performance.

 

 

Solid amber indicates a critical or non-recoverable condition.

 

 

Blinking amber indicates a non-critical condition.

 

 

No light indicates POST is running or the system is off.

 

 

 

G.

System Identification

Solid blue indicates system identification is active.

 

LED

No light indicates system identification is not activated.

 

 

 

 

 

H.

System Identification

Turns on/off the system identification LED.

 

Button

 

 

 

 

 

 

I.

Reset Button

Reboots and initializes the system.

 

 

 

 

 

16

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Callout

Feature

 

Function

 

 

 

 

J.

USB 2.0 Port

 

Allows you to attach a USB component to the front of the chassis.

 

 

 

 

K.

NMI Button

 

Puts the server in a halt-state for diagnostic purposes.

 

 

 

 

L.

Video Port

 

Allows you to attach a video monitor to the front of the chassis.

 

 

 

The front and rear video ports cannot be used at the same time.

 

 

 

 

 

 

Figure 11. Standard Control Panel

Intel® Local Control Panel

The diagram below shows the features available on the Intel® Local Control Panel. The Intel® Local Control Panel is one of two required control options that can be selected. The other option is the standard control panel. For instructions on installing the standard control panel, see “Replacing the Control Panel”.

 

A

B

 

 

C

 

 

D

 

 

E

 

 

F

 

O

N M L K J I H G

 

 

TP02214

Callout

Feature

Function

A.

USB 2.0 Port

Allows you to attach a USB component to the front of the chassis.

B.

LCD Display

Screen on which system information is displayed.

C.

Menu Control Button,

Scroll up one option at a time.

 

Scroll Up

 

D.

Menu Control Button,

Scroll down one option at a time.

 

Scroll Down

 

E.

Menu Control Button,

Move to the previous option.

 

Scroll Left

 

F.

Menu Control Button,

Select option.

 

Enter

 

G.

System Identification

Solid blue indicates system identification is active.

 

LED

No light indicates system identification is not activated.

 

 

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

17

Callout

Feature

Function

 

 

 

H.

Power/Sleep LED

Continuous green light indicates the system has power applied to

 

 

it.

 

 

Blinking green indicates the system is in S1 sleep state.

 

 

No light indicates the power is off / is in ACPI S4 or S5 state.

 

 

 

I.

Power/Sleep Button

Powers on/off the system.

 

 

Puts the system in an ACPI sleep state.

 

 

 

J.

System Status LED

Solid green indicates normal operation.

 

 

Blinking green indicates degraded performance.

 

 

Solid amber indicates a critical or non-recoverable condition.

 

 

Blinking amber indicates a non-critical condition.

 

 

No light indicates POST is running or the system is off.

 

 

 

K.

NIC 2 Activity LED

Continuous green light indicates a link between the system and

L.

NIC 1 Activity LED

the network to which it is connected.

 

 

Blinking green light indicates network activity.

 

 

 

 

 

M.

Hard Disk Activity

Random blinking green light indicates hard disk drive activity

 

LED

(SAS or SATA).

 

 

No light indicates no hard disk drive activity.

 

 

 

N.

Reset Button

Reboots and initializes the system.

 

 

 

O.

USB 2.0 Port

Allows you to attach a USB component to the front of the system.

 

 

 

Figure 12. Intel® Local Control Panel

Bezels

The optional front bezels provide a snap-on design that allows for maximum airflow through the server chassis. Two bezels are available. One fits a system that has the standard control panel installed. The other is used for a chassis with the other Intel® Local Control Panel. Each bezel provides a lock to secure the hard drive and optical drive area. For instructions on installing either of the front bezels, see “Installing the Front Bezel”.

The order numbers for the bezels are:

ADWBEZBLACK: Black bezel for use with the standard control panel.

ADWLCDBEZEL: Black bezel for use with the Intel® Local Control Panel.

18

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

Front Panel Features and Peripheral Devices

The server system provides locations and hardware for installing hard drives, a USB floppy drive, CD-ROM drive, or DVD-ROM drive. The drives must be purchased separately. The following figure shows the available options.

A B C A

D

TP02217

.

A.Rack Handles

B.Slimline Optical Drive

C.Mini Control Panel Bay

D.Hard Disk Drive Bays (Optional HDD Carriers shown)

Figure 13. Front Panel Features and Peripherals

Hard Disk Drives

The server system supports 2.5 inch SAS or Serial ATA (SATA) hot-swap drives. With the mini control panel, the system can support up to eight 2.5 inch hard drives. With the standard control panel or the Intel® Local Control Panel, the system can support up to six 2.5 inch hard drives.

For instructions on installing hard drives, see “Installing and Removing a Hot-swap Hard Drive”.

Note: Drives can consume up to 17 watts of power each. Drives must be specified to run at a maximum ambient temperature of 45C.

Note: The Intel® Server System SR1550AL does not support all SAS or Serial ATA (SATA) hard drives. See “Server System References” for an Internet link to a list of supported hardware.

Slimline Optical Drive Carrier

The slimline optical drive carrier can be used with an optional optical drive. One slimline carrier is included with your server system; the optical drive must be purchased separately. You cannot install both an optical drive and a USB floppy drive.

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

19

The slimline optical drive carrier can be inserted or removed only when system power is turned off. Drives in the optical drive carrier are NOT hot swappable. For installation instructions on installing an optical drive, see “Installing or Removing a Slimline Optical Drive or Internal USB Floppy”.

To use one of the drives provided by Intel, use the following order codes:

Slimline CD-ROM Drive: AXXSCD

Slimline DVD/CDR Drive: AXXDVDCDR

Note: The Intel® Server System SR1550AL does not support all slimline optical drives. See “Server System References” for an Internet link to a list of supported hardware. Intel provides accessory kits for these drives.

Advanced Management Options

Intel® Remote Management Module

The Intel® Remote Management Module is available to provide advanced system management features.

For installation instructions on installing the Intel® Remote Management Module, see the instructions provided with the management module.

20

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

3Hardware Installations and Upgrades

Before You Begin

Before working with your server product, pay close attention to the “Safety Information” at the beginning of this manual.

Tools and Supplies Needed

Phillips* (cross head) screwdriver (#1 bit and #2 bit)

Needle nosed pliers

Antistatic wrist strap and conductive foam pad (recommended)

System References

All references to left, right, front, top, and bottom assume the reader is facing the front of the server system as it would be positioned for normal operation.

Removing and Installing from a Rack

Three Intel® rack options are available to install the Intel® Server System SR1550AL in a rack. The options are the fixed bracket kit, the basic rail kit, and the tool-less rail kit. Only the tool-less rail kit allows you to service the server system while installed in a rack. The other rack options require the system to be removed from the rack before servicing.

Note: Follow all safety guidelines while removing a system from a rack to avoid injury.

Fixed Bracket Rack Mount Removal

1. Disconnect all cables from the back of the system.

Note: Remember to use the system LED to properly identify the system you are servicing.

2. Remove screws from the brackets and remove the system from the rack.

Fixed Bracket Rack Mount Installation

1.Fully extend a rail assembly; the finger tab for the extension lock is revealed.

2.Press the finger tab and slide the inside rail from the middle rail until it completely separates.

Note: The middle rail and outer rail cannot be separated.

3.Position an inside rail along one side of the chassis with the finger tab facing outward and located closer to the rear of the chassis.

4.Align the holes in the rail with the tabs on the chassis and place the rail against the chassis.

5.Slide the rail as far as it will go toward the front of the chassis to engage the tabs.

6.Fasten the rail to the chassis using one screw at the front of the chassis.

7.In the same manner, attach the other inside rail to the other side of the chassis

8.Using two screws, attach one nut bar to the inside of the rack post. Do not completely tighten the screws; leave them loose enough to allow insertion of the brackets in the next step.

9.Insert the slotted foot of a rail bracket between each nut bar and post.

10.Align the face of the bracket foot with the inside edge of the rack post and firmly tighten the screws.

11.Repeat steps 8 to 10 above to install the other 3 brackets (2 front & 2 back). Ensure all brackets are at the same height on the rack.

12.Position a rail assembly (middle and outer rails) with its black plastic end caps toward the rear of the rack and its outer rail closest to the brackets.

13.Align the front screw hole in the outer rail with the threaded hole nearest the front of the front bracket and fit the rail assembly into the front and rear brackets.

14.Slide the middle rail toward the front until the access hole in the middle rail is aligned with the front screw hole in the outer rail.

15.Insert screw through the access hole and loosely attach the outer rail to the front bracket.

16.In a similar manner to steps 13 through 15, install a screw through a slot in the outer rail and into the rear-most threaded hole in the front bracket. Firmly tighten this screw.

17.Firmly tighten the front screw installed loosely in step 15.

18.In the same manner, attach the other rail assembly to the other side.

19.Slide the middle rail toward the front until the rear bracket area is accessible.

20.Attach the rear end of the outer rail to the rear bracket with at least one screw. If possible, attach at two places.

21.In the same manner, attach the other rail assembly to the other side.

22

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

22.Fully extend the left and right rails until the extension locks have engaged and the rails will not push back in. The rail system is now ready to receive the chassis.

Caution: Lifting and placing the chassis in the rails is a two-person job. If needed, use an appropriate lifting device.

23.With the chassis front facing you, lift the chassis and carefully insert the rails attached to the chassis in the extended rails.

24.Slide the chassis toward the rear of the cabinet until the rails lock together.

25.Depress and hold down the finger tabs on both extension locks while sliding the chassis toward the rear.

26.Slide the chassis all the way into the rack until the chassis handles are against the front posts.

Basic Rail Rack Mount Removal

1. Disconnect all cables from the back of the system.

Note: Remember to use the system LED to properly identify the system you are servicing.

2.Pull system from rack until brackets are fully extended.

3.Push in both clips on the brackets and slide the system forward until the inner rail separates from the outer rail.

4.Remove and service the system.

Basic Rail Rack Mount Installation

1.Extend the inner rail until it locks.

2.Depress the spring safety lock to release the inner rail.

3.Remove the inner rail from the rail assembly.

4.Attach the outer rail slides to the rack posts using two #10-32 x 1/2 screws at the front posts, and two #10-32 x 1/2 screws at the rear posts.

Note: The rail flanges mount to the inside of each post.

5.Insert the inner rails over the server chassis sidewall studs.

6.Slide the inner rails toward the front of the server chassis.

7.Secure the inner rails with one #6-32 x 1/4 screw for each rail.

8.Align the inner rails (attached to the server chassis) with the outer rail assemblies (attached to the rack).

9.Engage the matching rails and slide the server chassis into the rack until the two safety stops lock into position.

10.Depress the two safety locks (one on each side).

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

23

11.Slide the server chassis all the way into the rack.

12.Use the rack screws (#10-32 x 3/4) to secure the chassis and rack handles into the rack.

Tool-less Rail Rack Mount Servicing

1.To service the system, pull the system out from the rack.

2.Disconnect the power cable(s) and proceed with servicing the system.

3.When the servicing is completed, re-connect the power cable(s).

4.Pull up on the green tabs on each rail and slide the system back into the rack.

Note: Beware of cables when re-installing the system into the rack so that the cables do not get pulled or interfered with.

Removing and Installing the Front Bezel

The front bezels are available as optional accessories for the Intel® Server System SR1550AL. Two front bezel options are available. One is used for the standard control panel and the other is used with the Intel® Local Control Panel. See the diagrams below to identify your front bezel. Note the orientation in the figures below - the control panel is at the right. If you are installing a bezel on your server system, make sure you position it as shown.

TP02220

Figure 14. Front Bezel Supporting the Standard Control Panel

TP02221

Figure 15. Front Bezel Supporting the Intel® Local Control Panel

24

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

TP02222

Figure 16. Front Bezel Supporting the Mini Control Panel

Removing the Front Bezel

Use the steps below if your system includes a front bezel.

1.Unlock the bezel (if locked).

2.Disconnect any cables attached to the control panel.

3.Pull the bezel from the server system.

TP02224

Figure 17. Removing the Front Bezel

Intel® Server System SR1550AL/SR1550ALSAS User’s Guide

25

Installing the Front Bezel

Use the steps below if your system includes either the standard front bezel or the front bezel for the Intel® Local Control Panel. The front bezel is optional.

1.At each end of the bezel, line up the center notch on the bezel with the center guide on the rack handles.

2.Push the bezel onto the front of the server system until it clicks into place.

3.Connect any necessary cables to the front control panel area at the right side of the server system.

TP02223

Figure 18. Installing the Front Bezel

Removing and Installing the Chassis Cover

Removing the Chassis Cover

The server system must be operated with the chassis cover in place to ensure proper cooling. You will need to remove the top cover to add or replace components inside of the server. Before removing the chassis cover, power down the server and unplug all peripheral devices and the AC power cable.

Note: A nonskid surface or a stop behind the server system may be needed to prevent the server system from sliding on your work surface.

1.Observe the safety and ESD precautions at the beginning of this book. See "“Safety Information”.

2.Turn off all peripheral devices connected to the server. Turn off the server.

3.Disconnect the AC power cord.

4.Remove the security screw if it is installed. See letter "A" in the figure below.