Intel I210-T1 User Manual

PRODUCT BRIEF Intel® Ethernet Server Adapter I210
Network Connectivity
Intel® Ethernet Server Adapter I210
Single-Port Gigabit Ethernet server adapter designed for entry-level servers and Audio-Video applications.
KEY FE ATURES
• Low-halogen1 single-port PCI-Express* 10/100/1000 Ethernet adapter
• Innovative power management features including Energy Efcient Ethernet (EEE),
DMA Coalescing, ultra-compact design, and a unique ventilated bracket for increased
efciency and reduced power consumption
• IEEE 802.1Qav Audio-Video-Bridging (AVB) for tightly controlled media stream syn-
chronization, buffering, and reservation
• High-performing design supporting PCI Express* Gen 2.1 2.5GT/s
• Reliable and proven Gigabit Ethernet technology from Intel Corporation
Overview
The new Intel® Ethernet Server Adapter I210 builds on Intel’s history of excellence in Ethernet products. Intel continues its market leadership with this newest gen­eration PCIe* GbE network adapter. Based on the Intel® Ethernet Controller I210, this adapter represents the next step in the Gigabit Ethernet (GbE) networking evolu­tion for the enterprise and data center offering Audio-Video-Bridging (AVB) sup­port, along with power management tech-
nologies such as Energy Efcient Ethernet
(EEE) and DMA Coalescing (DMAC).
Audio-Video Bridging (AVB)
The Intel® Ethernet Server Adapter I210 supports IEEE 802.1Qav Audio-Video Bridging (AVB) for customers requiring tightly controlled media stream synchro­nization, buffering, and reservation. The
802.1Qav is part of the AVB specication
that provides a way to guarantee bounded latency and latency variation for time
sensitive trafc and includes:
• Timing and Synchronization for time­specic applications (802.1AS) Stream
Reservation (SR) protocol to guarantee the resources needed for Audio/Video (AV) streams (802.1Qat)
• Forwarding and queueing enhancements
for time sensitive streams (802.1Qav).
Performance Optimization
The Intel® Ethernet Server Adapter I210 contains four transmit and four receive queues. These queues offer Error Correct­ing Memory (ECC) protection for improved
data reliability. The adapter efciently
manages packets with minimum latency by combining parallel and pipelined logic architectures optimized for these inde­pendent transmit and receive queues. These queues, combined with Receive Side Scaling (RSS) and Message Signal Interrupt Extension (MSI-X) support, optimize the performance on servers with multi-core processors.
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
Normal Power EEE Enabled
0.81 Watts
0.45 Watts
Power Savings w/EEE
Energy Efficient Ethernet Power Savings.
No Coalescing. As shown by the red line,
components have less time between DMA calls to reach and stay in lower power.
Power Management Technologies
Today, companies everywhere are looking for ways to decrease energy consumption across the enterprise to reduce costs and environmental impact, while at the same time solving increasingly important power density challenges. That’s why Intel has introduced new, advanced Power Man­agement Technologies (PMTs that enable
enterprises to congure power options on
the adapter and more effectively manage power consumption.
Energy Efficient Ethernet (EEE)
The Intel Ethernet Server Adapter I210 family supports the IEEE802.3az Energy
Efcient Ethernet (EEE) standard so that,
during periods of low network activity, EEE reduces the power consumption of an Ethernet connection by negotiating with a compliant EEE switch port to transition to
a low power idle (LPI) state.
This reduces the controller power to ap-
proximately 50% of its normal operating
power, saving power on the network port and the switch port. When increased net-
work trafc is detected, the controller and
the switch quickly come back to full power
to handle the increased network trafc.
EEE is supported for both 1000BASE-T and 100BASE-TX.
Based on the congurable DMAC settings,
incoming packets are buffered momen­tarily before any DMA calls are made. This enables the controller to intelligently identify opportunities to batch multiple packets together so that when compo­nents are wakened from lower power
states they can efciently handle the
batched packets at the same time. This enables platform components to remain in lower power states longer, which can dramatically reduce platform energy consumption. DMAC synchronizes DMA calls across all controller ports to ensure maximum power savings.
Environmentally Friendly Design
The Intel® Ethernet Server Adapter I210
Family is low halogen1 and completely
lead-free to reduce the potential for environmental impact. This, in combination with power management technologies, a unique ventilated bracket, and space­saving design make this adapter an ideal solution for compact workstations and entry-level servers.
With Coalescing. With more time between DMA calls, components can reach lower power states and remain in them longer
2
DMA Coalescing
Another power management technology that can reduce power on the server plat­form is DMA Coalescing (DMAC). Typically, when a packet arrives at the adapter, a DMA request is initiated in order to place the packet into host (or server) memory. This transaction wakes up the processor, memory, and other system components from a lower power state in order to perform the tasks required to handle the incoming packet.
General Features
Features Benefits
Intel® Ethernet Controller I210 With PCI Express* v2.1 Support
Low Halogen
Low profile single-port copper adapter • Compact design for high-density servers
Ships with full-height bracket installed; low-profile bracket included in package. Single-screw mount.
Ventilated bracket • Maximize airflow and cooling
1
• Industry-leading integrated MAC/PHY PCIe Gen2 GbE controller
• 2.5 GT/s support for x1 width (Lane)
• Leadership in an environmentally friendly ecosystem
• Streamlines installation
Ethernet Features
Features Benefits
Audio-Video Bridging (AVB) Support (802.1Qav) • Dedicated Tx and Rx Queues for AVB traffic
• Supports Forwarding and Queuing Enhancements for Time-Sensitive Streams
• Supports Time-based transmission
IEEE* 802.3* auto-negotiaton • Automatic link configuration for speed duplex and flow control
1 Gb/s Ethernet IEEE 802.3, 802.3u, 802.3ab PHY specifications compliant
Integrated PHY for 10/100/1000 Mb/s for multi­speed, full, and half-duplex
IEEE 802.3x and IEEE 802.3z compliant flow control support with software-controllable Rx thresholds and Tx pause frames
Automatic cross-over detection function (MDI/ MDI-X)
IEEE 1588 protocol and 802.1AS implementation • Time-stamping and synchronization of time sensitive applications
• Robust operation over installed base of Cat 5 twisted-pair cabling
• Smaller footprint and lower power dissipation compared to multiple discrete MAC and PHYs
• Local control of network congestion levels
• Frame loss reduced from receive overruns
• The PHY automatically detects which application is being used and configures itself accordingly
• Distribute common time to media devices
3
Power Management and Efciency Features
Features Benefits
IEEE 802.3az - Energy Efficient Ethernet (EEE) • Power consumption by the PHY is reduced by approximately 50%; link transitions to low power Idle (LPI)
DMA Coalescing • Reduces platform power consumption by coalescing, aligning, and synchronizing DMA
Smart Power Down (SPD) at S0 no link /Sx no link • PHY powers down circuits and clocks that are not required for detection of link activity
Active State Power Management (ASPM) • Optionality Compliance bit enables ASPM or runs ASPM compliance tests to support entry to L0s
LAN disable function • Option to disable the LAN Port and/or PCIe Function. Disabling just the PCIe function but keeping the
Full wake up support::
• Advanced Power Management (APM) Support– [formerly Wake on LAN]
• Advanced Configuration and Power Interface
(ACPI) specification v2.0c
• Magic Packet* wake-up enable with unique MAC
address
ACPI register set and power down functionality sup­porting D0 and D3 states
MAC Power Management controls • Power management controls in the MAC /PHY enable the device to enter a low-power state
Low Power Link Up - Link Speed Control • Enables a link to come up at the lowest possible speed in cases where power is more important than
Power Management Protocol Offload (Proxying) • Avoid spurious wake up events and reduce system power consumption when the device is in D3 low
state as defined in the IEEE 802.3az (EEE) standard
• Enables synchronizing port activity and power management of memory, CPU and RC internal circuitry
LAN port that resides on it fully active (for manageability purposes and BMC pass-through traffic).
• APM - Designed to receive a broadcast or unicast packet with an explicit data pattern (Magic Packet) and assert a signal to wake up the system
• ACPI - PCIe power management based wake-up that can generate system wake-up events from a num­ber of sources
• A power-managed link speed control lowers link speed (and power) when highest link performance is not requireds
performance
power state and system in in S3 or S4 low power states
Stateless Ofoads and Performance Features
Features Benefits
TCP/UDP, IPv4 checksum offloads (Rx/ Tx/Large­send); Extended Tx descriptors)
IPv6 support for IP/TCP and IP/UDP receive check­sum offload
Transmit Segmentation Offloading (TSO) (IPv4, IPv6) • Increased throughput and lower processor usage
Interrupt throttling control • Limits maximum interrupt rate and improves CPU usage
Legacy and Message Signal Interrupt (MSI) • Interrupt mapping.
Message Signal Interrupt Extension (MSI-X) • Dynamic allocation of up to 5 vectors per port
Intelligent interrupt generation • Enhanced software device driver performance
Receive Side Scaling (RSS) for Windows* • Up to four queues per port
Scalable I/O for Linux environments (IPv4, IPv6, TCP/ UDP)
Support for packets up to 9.5 KB ( Jumbo Frames) • Enables faster and more accurate throughput of data
Low Latency Interrupts • Based on the sensitivity of the incoming data, the controller can bypass the automatic moderation of
Header/packet data split in receive • Helps the driver to focus on the relevant part of the packet without the need to parse it
PCIe v2.1 TLP Processing Hint Requester • Provides hints on a per transaction basis to facilitate optimized processing of
Descriptor ring management hardware for Transmit and Receive
• More offload capabilities and improved CPU usage
• Checksum and segmentation capability extended to new standard packet type
• Improved CPU usage
• Improves the system performance related to handling of network data on multiprocessor systems
time intervals between the interrupts
• Optimized descriptor fetch and write-back for efficient system memory and PCIe bandwidth usage
4
Remote Boot Option Features
Features Benefits
Preboot eXecution Environment (PXE) flash inter­face support)
Intel® iSCSI Remote Boot for Windows, Linux, and VMware
Intel Boot Agent software--Linux* boot via PXE or BOOTP, Windows* Deployment Services, or UEFI
Descriptor ring management hardware for Transmit and Receive
• Enables system boot up via the EFI (32 bit and 64 bit)
• Flash interface for PXE 2.1 option ROM
• Enables system boot up via iSCSI
• Provides additional network management capability
• Enables networked computer to boot using a program code image supplied by a remote server• Complies with the Pre-boot eXecution Environment (PXE) Version 2.1 Specification
• Optimized descriptor fetch and write-back for efficient system memory and PCIe bandwidth usage
Managebility Features
Features Benefits
DMTF Network Controller Sideband Interface (NC-SI) Pass-through
Intel® System Management Bus (SMBus) Pass-through
Management Component Transport Protocol (MCTP) over SMBus and PCIe
OS2BMC Traffic support • Transmission and reception of traffic internally to communicate between the OS and local BMC
Private OS2BMC Traffic Flow • BMC may have its own private connection to the network controller and network flows are blocked
Firmware Based Thermal Management • Can be programmed via the BMC to initiate Thermal actions and report thermal occurrences
IEEE 802.3 MII Management Interface • Enables the MAC and software to monitor and control the state of the PHY
MAC/PHY Control and Status • Enhanced control capabilities through PHY reset, link status, duplex indication, and MAC Dx power state
Watchdog timer • Defined by the FLASHT register to minimize Flash updates
Extended error reporting • Messaging support to communicate multiple types/severity of errors
Controller Memory Protection • Main internal memories are protected by error correcting code (ECC ) or parity bits
Vital Product Data (VPD) Support • Support for VPD memory area
• Supports pass through traffic between BMC and Controller’s LAN functions
• Meets RMII Spec, Rev. 1.2 as a PHY-side devi
• Enables BMC to configure the Controller’s filters and management related capabilities.
• Used for baseboard management controller (BMC) communication between add-in devices
5
Specications
Connector • RJ-45 (Copper)
IEEE standard/network topology • EEE 802.3/10BASE-T, 100BASE-TX, 1000BASE-T
Cabling • Category-3 or higher for 10BASE-T operation
• Category-5 or higher for 100BASE-TX operation
• Category-5e or higher for 1000BASE-T operation
Data rate supported per port • 10/100/1000 Mbps copper
Bus Type • PCI Express* 2.1 (2.5GT/s)
Bus Width • 1-lane PCI Express; operable in x1 or greater slots
Interrupt levels • INTA, INTB, INTC, INTD, MSI, MSI-X
Hardware certifications • FCC B, UL CE, VCCI, BSMI, C TICK, KCC
Controller - processor • Intel® Ethernet Controller I210
Power consumption (active-typical) • 0.81 W
Operating temperature • 0 oC to 55 oC (32 oF to 131oF)
Storage temperature • -40 oC to 70 oC (-40 oF to 158 oF)
Storage humidity • 90% non-condensing relative humidity at 35 oC
Connect speed LED Indicators • Link/Activity LED: off = No Link; on = Link; Blinking = Activity
• Speed LED: Not illuminated = 10Mb/s; green = 100Mb/s; amber = 1 Gb/s
Physical Dimensons
Length 6.7 cm ( 2.64 inches)
(Bracket) Width 1.8 cm ( 0.709 inches)
Full-height end bracket 12.07 cm ( 4.755 inches)
Low-profile end bracket 8 cm (3.15 inches)
Intel Backing
Limited Lifetime Warranty
90-Day, money-back guarantee (U.S. and Canada)
Product Codes
Intel® Ethernet Server Adapter I210
I210 T1 Single Pack
I210T 1B LK Bulk Pack – Order 5, Get 5
6
Operation System/Architecture Support
Operating System IA32 X64
Windows XP Professional x64 Edition SP2
Windows XP Professional SP3
Windows Vista SP2
Windows 7 SP1
Windows Server 2003 SP2
Windows Server 2008 SP2
Windows Server 2008 SP2 Core
Windows Server 2008 SP2 (w/ Hyper-V role)
Hyper-V Server 2008 SP2 (stand-alone version)
Windows Server 2008 R2 SP1
Windows Server 2008 R2 SP1 Core
Windows Server 2008 R2 SP1 (w/ Hyper-V role)
Hyper-V Server 2008 R2 SP1 (stand-alone version)
WinPE 1.6 (2003 PE)
WinPE 2.1 (2008 PE)
WinPE 3.0 (2008 R2 PE)
Windows CE 6 (based on NDIS5.x)
Windows CE 7/WEC7 (based on NDIS6.x)
Windows Embedded Standard 7
Linux Stable Kernel version 2.6/3.x
Linux RHEL 5.8
Linux RHEL 6.2
Linux SLES 10 SP4
Linux SLES 11 SP2
FreeBSD 9
DOS NDIS
DOS ODI
EFI 1.1
UEFI 2.1
UEFI 2.3
VMware ESXi 5.0
VMware ESX M/N.next 3 (GA TBD)
Xen Key: ·=affected; Blank=not affected or OS not available on specied architecture
1-Minimal Validation 2- VMware ESX drivers are not included on the SW Release CDs; they are only available from VMware’s web
3-SR-IOV validation only
1
2
3
site and they are released on a separate sc
· ·
· ·
· ·
·
·
·
·
·
·
· ·
· ·
·
· ·
· ·
· ·
· ·
· ·
· ·
· ·
·
·
·
·
·
7
Customer Support
Intel® Customer Support Services offers a broad selection of programs including phone support and warranty service. For more infor­mation, Contact us at:
support.intel.com/support/go/network/
(Service and availability may vary by country.)
For Product Information
To speak to a customer service representative regarding Intel products, please call 1-800-538-3373 (U.S. and Canada) or visit:
support.intel.com/support/go/network/contact.htm
For the telephone number in your area. For additional product information on Intel Networking Connectivity products, visit:
www.intel.com/go/ethernet
For more information on Intel® Ethernet Server Adapter I210, visit www.intel.com/go/ethernet
1Low Halog en--Appl ies only to brominate d and chlor inated ame retard ants (BFRs/CFRs) and PVC in th e nal product. Intel co mponents as well as purc hased components on the nish ed assembly meet JS -709A requirement s, and the PCB/
Substr ate meet IEC 61249-2-21 requir ements. The replac ement of halogenat ed ame retardants an d/or PVC may not be better for the environme nt.
INFOR MATION IN THI S DOCUM ENT IS PROVIDED IN CONNECTION WI TH INTEL PRODUCTS. NO LICENSE , EXPRES S OR IMPLI ED, BY ESTOPPEL OR OTH ERWISE, TO ANY INTEL LECTUAL PROPERT Y RIGHTS IS G RANTED
BY THIS DOCU MENT. EXCEPT AS PROVIDED IN INTEL’S TERMS AN D CONDIT IONS OF SALE FOR SUCH PRO DUCTS, INTEL ASS UMES NO LIABILIT Y WHATSOEVER AN D INTEL DISCLAIM S ANY EXPRESS OR IM PLIED WARANT Y,
RELATIN G TO SALE AND/ OR USE OF INTEL PRODUC TS INCLUDING LIA BILITY OR WARR ANTIES RELATIN G TO FITNESS FOR A PARTI CULAR PURPO SE, MERCHANTABI LITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT
OR OTHER INT ELLECTUAL PROPER TY RIGHT.
A “Missi on Critical App lication” is any appli cation in which failure of the Intel Pr oduct could resul t, directly or indirectly, in pers onal injury or death. SHOULD YOU PURCHASE OR US E INTEL’S PRODU CTS FOR ANY SUCH MISSI ON
CRITIC AL APPLICATION, YOU SH ALL INDEMNIF Y AND HOLD INTEL AN D ITS SUBSI DIARIES, SUB CONTRACTORS A ND AFFILIATES, AND THE DIRECTORS , OFFICERS, AND EMPLOYE ES OF EACH, HA RMLESS AGAINS T ALL
CLAI MS COSTS, DAMAGES, A ND EXPENSES AND REASONAB LE ATTORNEYS’ FEES ARISING OUT OF, DIRECT LY OR INDIRECT LY, ANY CLA IM OF PRODUCT LIABILITY, PERSON AL INJURY, OR DEATH ARISI NG IN ANY WAY
OUT OF SUCH MISSION CR ITICAL APPLICATION, WHET HER OR NOT INTEL OR ITS SUBC ONTRACTOR WAS NEG LIGENT IN THE DESIG N, MANUFACTURE, OR WARNIN G OF THE INTEL PRODUCT OR AN Y OF ITS PARTS.
Intel may make ch anges to specic ations and product de scriptions at any tim e, withou t notice. De signers must not rely on the absence or characte ristics of any featur es or instructions
marked “reserve d” or “undened”. Intel reserve s these for fu ture denition and sh all have no responsibi lity whatsoever fo r conic ts or incompatibi lities arising fr om future changes to
them. The information here is subj ect to change without notice. Do not n alize a design with this in formation.
The produ cts described in th is document may conta in design defects or er rors known as errat a which may cau se the product to deviate from publis hed specicat ions. Current
charac terized errata ar e availabl e on request .
Contac t your loca l Intel sales ofce or you r distrib utor to obtain the latest sp ecication s and before pl acing your product or der.
Copies of documents that have an order num ber and are reference d in this docu ment, or other Intel lite rature, may be obtained by calling 1-800- 548-4725, or go to:
http://ww w.intel.com/design/literature.htm
Intel and the In tel logo are register ed trademarks of Inte l Corporation in the U.S. and other cou ntries.
Copyri ght © 2012 Intel Cor poration. All rights reser ved.
*Other na mes and brands may be claim ed as the property of others. Prin ted in USA 1212/LH/S U/PDF Please Recy cle 328083- 001US