Intel AXX6DRV3GEXP, AXX4DRV3G, AXX6DRV3G, AXX4DRV3GEXP Installation Manual

Drive Cage Upgrade Kit Installation Guide: Intel® Server Chassis SC5400
Order Number: D38448-002
This document provides instructions for installing the following accessory kits:
AXX4DRV3GEXP
AXX6DRV3GEXP
Disclaimer
Information in this document is provided in connection with Intel
®
products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel
product could create a situation where personal injury or death may occur. Intel may make changes to specifications
and product descriptions at any time, without notice.
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
*
Other names and brands may be claimed as the property of others.
Copyright © 2005-2006 Intel Corporation. All Rights Reserved.
ii Important Safety Instructions
Important Safety Instructions
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions. See Intel Server Boards and Server Chassis Safety Information at
http://support.intel.com/support/motherboards/server/safecert.htm
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel­Serverplatinen und -Servergehäusen unter
http://support.intel.com/support/motherboards/server/safecert.htm
重要安全指导
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或
http://support.intel.com/support/motherboards/server/safecert.htm
and Server Chassis Safety Information
服务器主板与服务器机箱安全信息》)。
(《Intel
.
.
上的
Intel Server Boards
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction.Consultez Intel Server Boards and Server Chassis Safety Information rendez-vous sur le site
http://support.intel.com/support/motherboards/server/safecert.htm
.
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en
http://support.intel.com/support/motherboards/server/safecert.htm
.
Important Safety Instructions iii
Warnings and Cautions
These warnings and cautions apply whenever you remove the access cover to access components inside the server. Only a technically qualified person should integrate and configure the server.
WARNINGS
The power button on the front panel DOES NOT turn off the AC power. To remove power from server, you must unplug the AC power cord from the wall outlet or the chassis.
Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cords, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing should be done by technically qualified personnel.
CAUTIONS
ESD can damage disk drives, boards, and other parts. Perform all procedures in this document only at an ESD workstation. If one is not available, provide ESD protection by wearing an anti-static wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. Do not touch the connector contacts. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
For proper cooling and airflow, always install the access cover before turning on the server. Operating it without the cover in place can damage system parts.
iv Warnings and Cautions
Contents
Before You Begin ................................................................................................ 1
About the Drive Cage Upgrade Kits ........................................................................................ 1
Kit Contents Lists .................................................................................................................... 2
Tools and Supplies Needed....................................................................................................4
How to use this Guide............................................................................................................. 4
Intel® Server Chassis SC5400 Installation ....................................................... 5
Remove the Access Cover...................................................................................................... 5
Remove the Bezel Assembly .................................................................................................. 6
Remove Hot Swap Fans ......................................................................................................... 7
Four-drive Upgrade Drive Cage Installation............................................................................ 8
Make Backplane Cable Connections: ................................................................................... 10
For a four-drive expander backplane connect the following cables: ............................ 10
For a four-drive non-expander backplane connect the following cables: ..................... 11
For a four-drive SAS hot swap drive cage installation: ................................................ 12
Six-drive Upgrade Drive Cage Installation ............................................................................ 13
Make Backplane Cable Connections: ................................................................................... 15
Make Server Board/RAID Controller Card Connections .......................................................18
Reinstall Hot Swap Fans.......................................................................................................18
Install Hot Swap Hard Drives ................................................................................................ 19
Install Fixed Hard Drives.......................................................................................................19
Replace Bezel Assembly ......................................................................................................19
Replace Access Cover.......................................................................................................... 21
Contents v
Figures
Figure 1. Removing Access Cover.......................................................................................... 5
Figure 2. Removing Bezel Assembly ...................................................................................... 6
Figure 3. Removing Hot Swap Fans from Chassis .................................................................7
Figure 4. Removing Grill .........................................................................................................8
Figure 5. Installing Drive Cage into Chassis ........................................................................... 9
Figure 6. Making Four-drive Expander Fixed Drive Cage Cable Connections .....................10
Figure 7. Making Four-drive Non-expander Fixed Drive Cage Cable Connections .............. 11
Figure 8. Removing Six-drive Fixed Drive Cage from Chassis ............................................. 13
Figure 9. Installing Six-drive Hot Swap Drive Cage into Chassis.......................................... 14
Figure 10. Layout of Cable Connectors on the Backplane.................................................... 15
Figure 11. Making Six-drive SAS Hot Swap Drive Cage Backplane Cable Connections
Figure 12. Making Six-drive Non-expander SAS Hot Swap Drive Cage Backplane Cable
Connections ................................................................................................................. 17
Figure 13. Reinstalling Hot Swap Fans.................................................................................18
Figure 14. Reinstalling Bezel Assembly................................................................................ 19
Figure 15. Replacing Access Cover...................................................................................... 21
vi Contents
Before You Begin
Before removing the access cover for any reason, observe these safety guidelines.
1. Turn off any peripheral devices connected to the server.
2. Turn off the server by pressing the power button on the front of the chassis.
3. Unplug the AC power cord from the chassis or wall outlet.
4. Label and disconnect all peripheral cables connected to I/O connectors or ports on the back of
the chassis.
5. Label and disconnect all telecommunication lines connected to I/O connectors or ports on the
back of the chassis.
6. Provide electrostatic discharge (ESD) protection by wearing an anti-static wrist strap attached
to a chassis ground—any unpainted metal surface—when handling components.
About the Drive Cage Upgrade Kits
Four- and six-drive cage upgrade kits allow you to install various hard drive solutions for the following Intel
Intel Intel Intel
NOTE
®
Server Chassis:
®
Server Chassis SC5400
®
Server Chassis SC5400 LX
®
Server Chassis SC5400 Base Redundant Power (BRP)
Refer to your server board documentation to determine SAS/SATA support for your server system.
If you want to use your SAS/SATA drives for a RAID configuration, you may need to install a SAS/SATA RAID add-in card. Refer to your server board documentation and/or your SAS/SATA RAID card documentation for additional installation instructions and requirements.
Before You Begin 1
Kit Contents Lists
Each upgrade kit contains different items. See the following for a list of contents for each upgrade kit.
Four-drive Fixed Drive Cage Upgrade Kit (AXX4FIXDB)
Item Quantity
Drive cage assembly 1
Fixed drive rails (pre-installed in drive cage) 8
This manual 1
Four-drive SAS Drive Cage Upgrade Kit (AXX4DRV3G)
Item Quantity
Drive cage assembly 1
SAS hot swap drive carriers (pre-installed in drive cage) 4
SAS/SATA connection ID label 1
SAS/SATA cable assembly 1
IPMB cable 1
SES cable 1
SGPIO cable 1
This manual 1
Four-drive SAS Drive Cage (Expander) Upgrade Kit (AXX4DRV3GEXP)
Item Quantity
Drive cage assembly 1
SAS hot swap drive carriers (pre-installed in drive cage) 4
SAS connection ID label 1
SAS cable assembly 1
IPMB cable 1
This manual 1
Six-drive SAS Drive Cage Upgrade Kit (AXX6DVR3G) 1
Item Quantity
Drive cage assembly 1
SAS hot swap drive carriers (pre-installed in drive cage) 6
SAS/SATA connection ID label 1
SAS/SATA cable assembly 1
IPMB cable 1
SES cable 1
SGPIO cable 1
This manual 1
2 Before You Begin
Six-drive SATA Drive Cage (Expander) Upgrade Kit (AXX6DVR3GEXP) 1
Item Quantity
Drive cage assembly 1
SAS/SATA hot swap drive carriers (pre-installed in drive cage) 6
SAS connection ID label 1
SAS cable assembly 1
IPMB cable 1
This manual 1
Before You Begin 3
Loading...
+ 18 hidden pages