Intek ELT-20F Installation Manual

INSTALLATION AND OPERATION
MANUAL
SELF-GENERATING STEAM FULL JACKETED TILTING
FLOOR MOUNTED KETTLES
MODELS: ELT-20F
ELT-30F ELT-40F ELT-60F
70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9
TELEPHONE: (416) 746-2358, FAX: (416) 746-8324
PART NUMBER 10170R1 1 2009-11-26
PRINTED IN CANADA
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM FULL JACKETED
TILTING FLOOR MOUNTED KETTLES, MODELS ELT-20F, ELT-30F, ELT-40F, ELT-60F
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.
Adequate clearances must be maintained for servicing and proper operation.
Intended for commercial use only. Not for household use.
This manual should be retained for future reference.
PART NUMBER 10170R1 2 2009-11-26
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM FULL JACKETED
TILTING FLOOR MOUNTED KETTLES, MODELS ELT-20F, ELT-30F, ELT-40F, ELT-60F
TABLE OF CONTENTS
DESCRIPTION PAGE
Important Notes for Installation and Operation .....................................2
1.0 Service Connections ....................................................4
2.0 Installation Instructions ...................................................5
3.0 Introduction ............................................................7
4.0 Operation Instructions ...................................................9
5.0 Cleaning Instructions ...................................................11
6.0 General Maintenance ...................................................14
7.0 Troubleshooting ......................................................17
Appendix A, Material Safety Data Sheet ........................................18
PART NUMBER 10170R1 3 2009-11-26
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM FULL JACKETED
TILTING FLOOR MOUNTED KETTLES, MODELS ELT-20F, ELT-30F, ELT-40F, ELT-60F
1.0 SERVICE CONNECTIONS
PART NUMBER 10170R1 4 2009-11-26
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM FULL JACKETED
TILTING FLOOR MOUNTED KETTLES, MODELS ELT-20F, ELT-30F, ELT-40F, ELT-60F
2.0 INSTALLATION INSTRUCTIONS
UNPACKING
Immediately after unpacking, check for possible shipping damage. If the kettle is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
Before installing, verify that the electrical service agrees with the specifications on the rating plate located on the right side of the tilt console. If the supply and equipment requirements do not agree, contact your dealer or Crown Food Service Equipment Ltd.
Select a location with drainage directly below the tangent draw-off. Allow sufficient rear clearance from wall for kettle cover to lift upright freely and completely without obstructions.
INSTALLATION
1. The kettle must be installed in accordance with:
1. State and/or local codes.
2. In the USA, the National Electrical code, ANSI/NFPA-70 (latest edition). In Canada, the Canadian Electrical Code, Part 1, CSA Standard C22.1 (latest edition).
2. Set the kettle in the installation location.
3. With the kettle in the upright position, place a carpenter’s level on top of the kettle and turn the adjustable feet to level kettle side-to-side and front to back.
4. Mark hole locations on floor through anchoring holes provided in flanged adjustable feet.
5. Remove kettle and drill holes in locations marked on the floor (see installation diagram). Insert proper anchoring devices to accommodate 5/16" size lag bolts (not supplied).
6. Reposition kettle. Re-level kettle by making necessary adjustments on flanged feet.
7. Bolt down kettle and seal with Silastic or other equivalent sealing compound. Sealant must be applied not only to bolt heads but also around flanges or pedestal base making contact with floor surface to fulfill NSF requirements. Wipe off excess sealant immediately.
PART NUMBER 10170R1 5 2009-11-26
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM FULL JACKETED
TILTING FLOOR MOUNTED KETTLES, MODELS ELT-20F, ELT-30F, ELT-40F, ELT-60F
2.0 INSTALLATION INSTRUCTIONS (Continued)
WARNING: Disconnect the electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit.
ELECTRICAL CONNECTIONS
A Control Box with power supply equivalent to electrical rating of the kettle should be located conveniently nearby.
Remove the wiring compartment cover and make electrical connections per wiring diagram located inside the control housing cover panel. A waterproof electrical connection from power supply to rear of control housing must be provided.
Kettle must be grounded in accordance with requirements of the National Electrical Code or applicable local codes.
Ground kettle to terminal provided in control housing. Once proper connections are made, replace wiring compartment cover, turn power ON and
check for proper operation.
SERVICE CONNECTIONS
All internal wiring for the kettle is complete. If faucet is provided connect water supply and check for proper operation.
INSTALLATION CODES AND STANDARDS
Your electric tilting kettle must be installed in accordance with:
1. Provincial and local codes, or in the absence of local codes, with: C.S.A. C22.1 Canadian Electrical Code, Part 1, or in the U.S.A., the National Electrical Code ANSI/NFPA-70 (latest edition).
2. ANSI NFPA Standard #96, “Vapor Removal from Cooking Equipment,” (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA,
02269.
PART NUMBER 10170R1 6 2009-11-26
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM FULL JACKETED
TILTING FLOOR MOUNTED KETTLES, MODELS ELT-20F, ELT-30F, ELT-40F, ELT-60F
3.0 INTRODUCTION
DESCRIPTION
All electrically powered kettles described and referred to in this manual are pressure vessels of a double-wall construction forming a sealed jacket (chamber) enveloping the kettle bowl surface.
The kettle bowl is the container for the food product which ideally should be a liquid or semi­liquid consistency to achieve complete contact with the bowl surface. Food products will fully absorb the heat transmitted through that surface from the pressurized steam generated in the kettle jacket.
The jacket is intended to function as a self contained sealed chamber with a permanent solution of water and antifreeze sufficient not only to immerse and thereby protect replaceable electric heating elements, but also provide the steam source during the steam generating process.
The heating elements are thermostatically controlled to provide precise temperatures throughout the range from slow simmer to rolling boil.
All tilting kettles are intended to be permanently floor mounted on legs with adjustable flanged feet.
A sealed stainless steel tilt mechanism permits the kettle to tilt forward a full 90º for complete emptying. The tilting mechanism is self locking for positive stop action.
CAPACITIES
All models are suffixed with either - 20F, - 30F, - 40F or -60F to indicate the capacity of that kettle in US gallons. Thus an ELT-40F indicates a full jacketed electrically powered steam kettle mounted on legs with a capacity of 40 US gallons.
PART NUMBER 10170R1 7 2009-11-26
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM FULL JACKETED
TILTING FLOOR MOUNTED KETTLES, MODELS ELT-20F, ELT-30F, ELT-40F, ELT-60F
FUNCTIONING MODE
All electrically powered self-generating, steam jacketed kettles, consist of a jacket containing a permanent solution of distilled water sufficient to completely immerse and protect replaceable electric heating elements.
To minimize tampering, the Safety Valve is plumbed toward the rear of the kettle jacket. Should any component malfunction and cause the pressure in the jacket to reach the rated pressure of the kettle, this protective device will open automatically and release excessive pressurized steam.
When the Power Switch is turned ON and the Temperature Control (Thermostat) Knob dialed, the TEMPERATURE pilot light will light and contactors will close to allow power to the elements. Steam generation will commence and continue until the preselected temperature is reached, at which point the contactors open, cutting off power to heating the elements. The TEMPERATURE pilot light will then extinguish. When the temperature of the water in the jacket drops slightly, the cycle will repeat itself thus making it possible to maintain any selected precise cooking mode temperature.
The temperature required for the cooking process to function adequately must be greater than the boiling point of the liquid food product. Further, the higher the temperature, the greater the steam pressure attained in the jacket and consequently the quicker the cooking process. For example, steam pressurized at 30 p.s.i. attains a temperature of 274º Fahrenheit.
Since air is an unsuitable media through which heat may be transferred, it has been removed from the kettle jacket during testing at the factory. The Pressure Gauge should indicate vacuum in the jacket in green zone on the gauge (approximately 20 - 25 inches Hg) when the kettle is cold or has been inoperative for some time. The kettle jacket is intended to function at all times as a completely sealed self-contained chamber and it is especially advisable not to trip the safety relief valve during inoperative periods since this will break the vacuum seal and allow air to enter the kettle jacket.
The Temperature Controls (thermostats) used in these kettles have been calibrated to prevent the heating elements from generating steam pressure that would exceed the rated working pressure of the kettle. In the unlikely event that the Temperature Control fails and the heating elements remain energized, the Safety Valve will blow and release the excessive pressure and steam from the jacket, consequently lowering the water level in the jacket. The Safety Probe sensing depletion of the water level in the kettle jacket will not only activate the LOW WATER level indicator pilot light, but also signal the Liquid Level Control to switch off power and de­energize the circuit to the heating elements (preventing element burn outs) until the water level is adequately replenished.
PART NUMBER 10170R1 8 2009-11-26
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM FULL JACKETED
TILTING FLOOR MOUNTED KETTLES, MODELS ELT-20F, ELT-30F, ELT-40F, ELT-60F
4.0 OPERATION INSTRUCTIONS
WARNING: The kettle and its parts are hot. Use care when operating, cleaning and servicing the kettle.
Ensure that the external electrical service to kettle is on. Check pressure gauge for correct cold kettle reading. Reading should be in the green area of
the gauge indicating 25 - 30 In. Hg (630 - 730 mm Hg) of vacuum. If reading is not low enough, follow VENTING procedure in Troubleshooting section prior to using kettle.
Place power switch to ON position. Preheat kettle by placing thermostat knob at ‘10' and wait until TEMPERATURE light goes off.
NOTE: Preheating should not be used when cooking milk and egg food products which adhere to hot cooking surfaces. These foods should be placed into kettle before heating has begun.
Add food to be cooked into kettle.
PART NUMBER 10170R1 9 2009-11-26