Integrated Engineering
Smart ID Reader Family
Model Desfire
FCC ID P4ESMARTPROX11
Specifications
Typical read range with an ISO Card
SmartID/EM4102 5 - 10 cm
SmartID/ Hitag1&2 5 - 10 cm
SmartID/ISO14443 2 - 5 cm
SmartID/ISO15693 5 - 15 cm
Power Supply
4.75 – 12.25 Volt DC
Current requirements
Average 50 mA
Peak 160 mA
Interface
Inputs EMC Prot. 10Kohm pull-ups
Outputs EMC Prot. open drain 0.5 A/max
Dimensions
142 x 46 x 25 mm
Material
SB housing with polyurethan potting
Operating temperature
-20° to 60° C
Certifications
EN50022, CE, FCC
Cable Distance
25 meter. Recommended cable 8 x 0.35 conductor
stranded overall shield or equivalent.
The Smart ID Reader has a slim door style mountable
design to match any decor. The buried LED’s and
buzzer allow the Smart ID Readers to be mounted
indoors and out. The Smart ID Reader accepts 4.75 to
12.25 Volts DC. The output formats like clock-anddata magstripe (ABA / ISO7811), Wiegand and a
number of other formats are determined by the
personalization of the card and are emitted without
customizing the Reader. The 5 Volt DC capability
allows the replacement of older reader systems
without rewiring or pulling new cables. The Smart ID
Reader offers high reliability, consistent read
characteristics and low power consumption.
Within the Smart ID Proximity Reader Family also
models with a RS232/RS422/RS485 interface are
available for read and write operations.
The Smart ID Reader Family supports both the
125KHz and 13.56MHz technologies. Different
models are available for EM4002, EM4050, HiTAG1
and 2, Mifare and I•Code silicon. Standard
capabilities include Host system controlled red and
green LED’s and a buzzer. The Smart ID Reader can
be mounted on any surface without relevant
performance degradation. For mounting to a metal
wall a spacer is advised.
Our commitment is to bring non-propriety, open Radio
Frequent Identification (RFID) systems to the market
demonstrated with the Smart ID Reader Family.
Features
Mullion mounting
The Smart ID Readers can be mounted on a door
mullion.
Optional there is a mounting kit available in case the
small Smart ID reader will be mounted over a wall box
(mounting US back box, vertical 84 milimeter,
mounting European back box, horizontal 60
millimeter).
Indications
When a proximity card is decoded successfully the
with the card associated code is send to the Host
system and the buzzer sounds a short 3KHz beep.
Both LED’s and the buzzer are also controllable by
the Host system.
Connections
The Smart ID Reader Family has a flexible and
reliable connector interface. The space for the cable
and the connector within the Smart ID housing can be
poured with silicone to withstand harsh environmental
conditions.
Interface Coding
The Smart ID Reader Family can operate with any
facility, system or card coding scheme. The output
format, contents and length are determined by the
personalization of the card. Output formats like
magstripe, Wiegand and several others are available.
Security
Depending on the model and the silicon used the
Smart ID Reader Family offers high security challenge
response schemes to protect the RFID air interface
against simulations of cards.
Ref: V4.3 - 24/03/2004

Parts List
1) Reader 4.75-12.25 VDC qty 1
2) Terminal Connector 8 pins qty 1
3) Mounting cover qty 1
4) Mounting cap qty 1
5) Installation sheet qty 1
6) Mounting kit / back plate (optional) qty 1
7) Cable, 8 x 0.35 conductor as required
Installation instruction
1) Determine an appropriate position for the
Reader and drill two holes for mounting the
reader to the surface (see diagram). Do not
mount the readers less than 20 cm from each
other. Make sure that enough room to connect
the cable is allowed. Protect the cable against
sharp edges and any damage from chaffing.
2) Remove the Terminal Connector 8 pins from the
back of the Reader. Use a small flat head
screwdriver to loosen off all of the terminals.
The end of the cable should be prepared by
cutting it back to expose the wires and each end
should be twisted to eliminate any loose or
frayed wires.
3) The wires should then be connected to the
Reader inline with the Connector Assignments.
4) After wiring the reader and the Host system the
Reader is ready to be tested. Apply power and
present a Card to the Reader. The green LED
should flash and the buzzer should beep
indicating a read. If the Host system is
connected to the red and green LED inputs
these should follow the functionality of the Host
system.
5) The Reader should now be secured to the
surface using the appropriate screws. Mount the
black cover (sticker) and mount the cap over the
mounting hole.
Mullion Mounting
Connector Assignments
Wiegand / Clock and Data
SmartID/EM4102
SmartID/Hitag1&2
SmartID/DESFire
SmartID/ISO14443-3
SmartID/ISO14443-3/pin
SmartID/ISO14443/SNR
SmartID/ISO15693/SNR
1 ! Green LED input 5 ! Buzzer input
2 ! Red LED input 6 NC
3 " Data / D1 7 ! Ground
4 " Clock / D0 8 ! Power
RS232
SmartID/Hitag1&2/RW
SmartID/DESFire/RO
SmartID/ISO14443-3/Sect/RS
SmartID/ISO14443/SNR/RS
SmartID/ISO15693/SNR/RS
1 ! Green LED input 5 ! Do not connect
2 ! Red LED input 6 ! RS232 RXD
3 " Do not connect 7 ! Ground
4 " RS232 TXD 8 ! Power
RS422
SmartID/ISO14443-3/Sect
SmartID/ISO14443/SNR/RS
SmartID/ISO15693/SNR/RS
1 ! Green LED input 5 ! RS422 RXA
2 ! Red LED input 6 ! RS422 RXB
3 " RS422 TXA 7 ! Ground
4 " RS422 TXB 8 ! Power
Other FCC ID's are:
• Hitag1&2: Smart ID/Hitag1&2
PX007Z/HX " P4EHPROX-02
• ISO14443: Smart ID/ ISO14443/SNR
PX007Z/XXSNR " P4EI-MSNRPOX-02
• ISO 14443-3: Smart ID/ISO14443-3/Sect
PX007Z/MF " P4EMPROX-03
Consult your National Authority if any
authorization is needed for this product.
This device complies with Part 15 of the FCC
Rules. Operation is subject to
conditions:
1) that this device does not cause harmful
interference, and
2) that this device must accept any interference
received, including interference that may cause
undesired operation.
Integrated Engineering
Amsterdam
The Netherlands
Phone: +31 20 4620755
Fax: +31 20 4620756
Email: info@ieprox.com
WWW: http://www.ieprox.com
the following two