PRT-PXS16-PCB
Protege Standard 16 PGM Output Expander
Quick Start Guide
1. Introduction
Thank you for purchasing the Protege Standard 16 PGM Output
Expander by Integrated Control Technology. The Protege Standard
16 PGM Output Expander provides the control of 16 low current open
collector Outputs.
When receiving the Protege Standard 16 PGM Output Expander you
should find the kit contains the items listed below. The kit type is
clearly labelled on the packaging and will tell you what your kit
contains. Please note that if you do not have the correct contents
contact your distributor immediately.
Protege Standard 16 PGM Output Expander
y
Protege Standard 16 PGM Output Expander Quick Start Guide
y
4x Nylon Spacers
y
For more information on the Protege Standard 16 PGM Output
Expander and other Integrated Control Technology products please
login to www.incontrol.co.nz.
2. Configuration
The Standard 16 PGM Output Expander must be configured with an
address before it will communicate with the Protege System.
3. Device Address
The switch positions 1 to 7 select the device address from 1 to 128.
When setting an address the Standard 16 PGM Output Expander
must be powered down and restarted for the new address to take
affect.
When changing the address the Standard 16 PGM Output Expander
will automatically default the internal configuration and require a
network update. See the Protege System reference manual for
information on performing a module update.
ONOFF
1 ADDRESS 1
2 ADDRESS 2
3 ADDRESS 4
4 ADDRESS 8
5
6 ADDRESS 32
7 ADDRESS 64
8DEFAULT/RUN
ADDRESS 16
ONOFF
1 ADDRESS 1
2 ADDRESS 2
3 ADDRESS 4
4 ADDRESS 8
5
6 ADDRESS 32
7 ADDRESS 64
8 DEFAULT/RUN
ADDRESS 16
Configuration Switch Settings
The configuration switch image on the right shows the
address setting for device address 008. The configuration
switch on the left shows address 001 (Default).
4. Encrypted Module Network
Support for up to 128 PGM expanders per system controller is
provided. The Protege System uses a high speed encrypted RS-485
communication interface.
Module or Controller Supply
Power to Networked Devices
+AUX-
NAN+ N- NB
NAN+ N- NB
Standard Communication Connection
NAN+ N- NB
Next modules
on network
5. End of Line Termination (EOL)
The end of line (EOL) jumper should be ON when the Standard 16
PGM Output Expander is located at the start or end of the module
network.
EOL OFF EOL ON
EOL Jumper
6. Zone Input
The Standard 16 PGM Output Expander does not have any provision
for interfacing to zone input devices. For expansion of zone inputs in
the Protege System refer to the PRT-ZXS16 and PRT-ZX16
installation manuals.
7. Trouble Zone Input
Trouble zones are used to monitor the status of the Standard 16 PGM
Output Expander and in most cases not physically connected to the
an external zone. An example is trouble zone 8 is the communication
trouble zone, this will open when the Standard 16 PGM Output
Expander is removed from the system or has lost communication.
Trouble Zone Function
PXXXX:01 Tamper Input. Normally Closed Contact.
PXXXX:02 Power Fault. Power to the Standard 16 PGM
PXXXX:03 Reserved
PXXXX:04 Reserved
PXXXX:05 Reserved
PXXXX:06 Reserved
PXXXX:07 Reserved
PXXXX:08 Device Communication. The Standard 16 PGM
Output Expander is below 10.5VDC.
Output Expander has lost communications and is
no longer online with the Protege SE Integrated
System Controller.

8. Programmable Output
A PGM is a programmable output that can be activated and
deactivated based on specific events or functions within the Protege
System. The primary function of the Standard 16 PGM Output
Expander is to activate any one of the 16 onboard PGM Outputs.
PGM Function
PXXXX:01 P1 Open Collector PGM Output
PXXXX:02 P2 Open Collector PGM Output
PXXXX:03 P3 Open Collector PGM Output
PXXXX:04 P4 Open Collector PGM Output
PXXXX:05 P5 Open Collector PGM Output
PXXXX:06 P6 Open Collector PGM Output
PXXXX:07 P7 Open Collector PGM Output
PXXXX:08 P8 Open Collector PGM Output
PXXXX:09 P9 Open Collector PGM Output
PXXXX:10 P10 Open Collector PGM Output
PXXXX:11 P11 Open Collector PGM Output
PXXXX:12 P12 Open Collector PGM Output
PXXXX:13 P13 Open Collector PGM Output
PXXXX:14 P14 Open Collector PGM Output
PXXXX:15 P15 Open Collector PGM Output
PXXXX:16 P16 Open Collector PGM Output
9. Error Messages
When the Standard 16 PGM Output Expander is powered up and
starts communicating with the controller it is possible that the
Standard 16 PGM Output Expander can be denied access to the
module network. This is a normal part of the Protege System.
In normal operation the status indicator will flash rapidly while it is
attempting to contact the controller. When it is online it will turn flash
at one second intervals. When an error occurs the status indicator will
FLASH with the error code number. The error code number is shown
with a 250ms ON and OFF period (duty cycle) with a delay of 1.5
seconds between each display cycle.
Flash Error Description
1 Internal Error
An internal error has occurred on the Standard 16 PGM
Output Expander. Please contact your distributor.
2 Version Error
The version of the Standard 16 PGM Output Expander is
not correct for the system controller. The firmware must be
updated. Please contact your distributor.
3 Address Too High
The address of the Standard 16 PGM Output Expander
that is programmed is beyond the maximum number of
Standard 16 PGM Output Expander that are allowed to
connect to the system controller. You may also be able to
adjust the controller profile to increase the Standard 16
PGM Output Expander module capacity.
4 Duplicate Device Address
The address of the Standard 16 PGM Output Expander is
already programmed in to the address location.
5 Security Violation
The system controller has security enabled and no devices
can be added to the system.
6 Invalid Serial Number
The Standard 16 PGM Output Expander has an invalid
serial number programmed and can not be registered on
the system. Return the Standard 16 PGM Output Expander
to your distributor.
10. Technical Specifications
Operating Voltage 11.5VDC to 14.25VDC
Operating Current 47mA (83mA, Max)
Communication (Serial) Communication Interface Port
Zone Inputs 16x Standard Zones Dual EOL Resistor
PGM Outputs 1x 50mA (Max) Open Collector Output for
Operating Temperature 5˚ to 55˚C (41˚ to 131˚F)
Storage Temperature -10˚ to 85˚C (14˚ to 185˚F)
Humidity 0% to 85% (Non Condensing)
Dimensions (H x W x D) 93 x 130 x 12mm (3.66 x 5.11 x 0.47”)
Weight 165g (5.82oz)
The size of conductor used for the supply of power to the Protege
Intelligent 5 Amp Power Supply should be adequate in size to prevent
voltage drop at the terminals of no more than 5% of the rated supply
voltage.
Specifications are subject to change without notice, please visit
www.incontrol.co.nz for updated information.
11 Canaveral Drive, Albany, North Shore City 0632, Auckland, New Zealand
P.O. Box 302-340, North Harbour, Auckland, New Zealand
Designers and manufacturers of integrated electronic access control, security and building
Designed and manufactured by Integrated Control Technology Limited.
© Copyright Integrated Control Technology Limited 2003-2011. All rights reserved.
(1K+1K) or No Resistor per Zone
General Functions
Integrated Control Technology Limited
Phone: +64 (9) 476 7124
Fax: +64 (9) 476 7128
Email: support@incontrol.co.nz
www.incontrol.co.nz
automation products.
227-4095-002