INSTALLATION INSTRUCTION
Evore Fire Rated Downlight
Generic Installation Details
1. Ensure the mains power is turned OFF and cannot be unexpectedly reconnected.
2. For new installations use cutting tools suitable for the material and carefully cut the
required hole. Refer to box packaging for cut-out dimension.
3. For refurbishment / retrot installations, ensure that existing hole is suitable and
strong enough to hold the new downlight. Support the surrounding area if required.
If the existing hole is larger than the prescribed cut-out, an additional adapter is
available.
4. Connect the AC/mains cable. Where a terminal block is provided, incoming cable
connections are; L = Live power conductor (brown wire), N = Neutral power conductor
(blue wire), Earth green/yellow wire).
• UK design and engineered for LED lamps only.
• Completely open construction to allow for good air circulation for improved lifetime
and the highest output possible for LED lamps.
• Fire rated for 30 minutes, 60 minutes and 90 minutes ceilings to BS 476: Part 21:1987
by UKAS approved Exova Warringtonre when installed in ceilings of approved
construction.
• Patent pending construction.
• IP65 dust and moisture sealed from the front when installed correctly.
• Models supplied with ‘Insulation Guard’ are suitable for coverage by thermal and
acoustic insulation e.g. loft insulation. Not suitable for blown insulation.
• Compliant with Part B (Fire), Part C (Condensation), Part E (Acoustic), Part L
(Conservation and Fuel and Power, when used with high quality LED lamps such as
Integral).
• Compliant with BS EN ISO 140-3:1995, BS EN ISO 140-6:1998, BS EN ISO 717-1:1997,
BS EN ISO 717-2:1997.
Important Details – Please read prior to installation
1. Ensure the AC/Mains power is NOT connected and cannot be unexpectedly
reconnected during installation.
2. This product must be installed by a qualied electrician in accordance with
instructions provided and in compliance with recognised electrical and safety
regulations relevant to the country it is being installed.
3. This product must not be used with non-LED lamps.
4. This downlight range is designed to be installed in a ceiling tile / plasterboard / solid
material, with a thickness of 3mm (minimum) to 30mm (maximum).
5. This product is for indoor use only.
6. The product should NOT be covered with insulation material at any time. Unless
using a model with an insulation guard.
7. Minimum clearance is 50mm above the installed tting and should NOT be installed
within 50mm of any joist.
8. Earth wire is provided if required.
Generic Installation Details
Refer to the correct instruction pages for your product.
Full part number
ILDLFR70D001
ILDLFR70D001-4
ILDLFR70D002
ILDLFR70D002-4
ILDLFR70D003*
ILDLFR70D003-3*
ILDLFR70D004*
ILDLFR70D004-3*
ILDLFR70D005
ILDLFR70D006
ILDLFR70D007
ILDLFR70D008
ILDLFR70D009*
ILDLFR70D010*
ILDLFR70D011
ILDLFR70D012*
ILDLFR70E001
ILDLFR70E002
ILDLFR60F001
ILDLFR60F002
*Models with Insulation Guard
**Models not supplied with GU10 lamp holder or junction box
EAN barcode
5055788228325
5055788228356
5055788228387
5055788228417
5055788228448
5055788228479
5055788228509
5055788228530
5055788228561
5055788228592
5055788228622
5055788228653
5055788228684
5055788228714
**
5055788228905
/
**
5055788228943
5055788228745
5055788228776
5055788228806
5055788228837
EVOFRDLINSTR04
IP65
Warranty/Technical and contact
information are all available at
www.integral-led.com
London NW10 0UF

A1
A2
Loop-In-Loop-Out
Neutral(blue)
Live(brown)
Earth(green/yellow)
**Where supplied
To down light
A3
A4
A5
A6
A8A7
2
NL
1 1
1 2
GU10 LED ONLY
MAXIMUM 10W
B1
C1
D1
B2
C2
1
Adapter availableHole > Cut-out?
A2-A8
C3
2
C4
GU10 LED ONLY
MAXIMUM 10W
1
C5
1
x4
Loop-In-Loop-Out
Neutral(blue)
Live(brown)
Earth(green/yellow)
To down light
3.5mm
D4D3D2
72 hours
72 horas
72 heures
72 der dienststuden
72 godzin
2
D6D5
16 hours
16 horas
16 heures
16 der dienststuden
16 godzin
D7
Loop-In-Loop-Out
Neutral(blue)
Live(brown)
Earth(green/yellow)
To down light
D8
GU10 LED ONLY
MAXIMUM 10W
1
2
E1
E2