Integral LED Technology LLP ILDLFR70D002 Installation Instructions

W
10
MAX
LED Only
INSTALLATION INSTRUCTION
Evore Fire Rated Downlight
Generic Installation Details
1. Ensure the mains power is turned OFF and cannot be unexpectedly reconnected.
2. For new installations use cutting tools suitable for the material and carefully cut the required hole. Refer to box packaging for cut-out dimension.
3. For refurbishment / retrot installations, ensure that existing hole is suitable and strong enough to hold the new downlight. Support the surrounding area if required. If the existing hole is larger than the prescribed cut-out, an additional adapter is available.
4. Connect the AC/mains cable. Where a terminal block is provided, incoming cable connections are; L = Live power conductor (brown wire), N = Neutral power conductor (blue wire), Earth green/yellow wire).
UK design and engineered for LED lamps only.
Fire rated for 30 minutes, 60 minutes and 90 minutes ceilings to BS 476: Part 21:1987
by UKAS approved Exova Warringtonre when installed in ceilings of approved
construction.
Patent pending construction.
IP65 dust and moisture sealed from the front when installed correctly.
Models supplied with ‘Insulation Guard’ are suitable for coverage by thermal and acoustic insulation e.g. loft insulation. Not suitable for blown insulation.
Compliant with Part B (Fire), Part C (Condensation), Part E (Acoustic), Part L (Conservation and Fuel and Power, when used with high quality LED lamps such as Integral).
Compliant with BS EN ISO 140-3:1995, BS EN ISO 140-6:1998, BS EN ISO 717-1:1997, BS EN ISO 717-2:1997.
Important Details – Please read prior to installation
1. Ensure the AC/Mains power is NOT connected and cannot be unexpectedly reconnected during installation.
2. This product must be installed by a qualied electrician in accordance with instructions provided and in compliance with recognised electrical and safety regulations relevant to the country it is being installed.
3. This product must not be used with non-LED lamps.
4. This downlight range is designed to be installed in a ceiling tile / plasterboard / solid material, with a thickness of 3mm (minimum) to 30mm (maximum).
5. This product is for indoor use only.
6. The product should NOT be covered with insulation material at any time. Unless using a model with an insulation guard.
7. Minimum clearance is 50mm above the installed tting and should NOT be installed within 50mm of any joist.
8. Earth wire is provided if required.
Generic Installation Details
Refer to the correct instruction pages for your product.
Full part number ILDLFR70D001 ILDLFR70D001-4 ILDLFR70D002 ILDLFR70D002-4 ILDLFR70D003* ILDLFR70D003-3* ILDLFR70D004* ILDLFR70D004-3* ILDLFR70D005 ILDLFR70D006 ILDLFR70D007 ILDLFR70D008 ILDLFR70D009* ILDLFR70D010* ILDLFR70D011 ILDLFR70D012* ILDLFR70E001 ILDLFR70E002 ILDLFR60F001 ILDLFR60F002
*Models with Insulation Guard **Models not supplied with GU10 lamp holder or junction box
EAN barcode 5055788228325 5055788228356 5055788228387 5055788228417 5055788228448 5055788228479 5055788228509 5055788228530 5055788228561 5055788228592 5055788228622 5055788228653 5055788228684 5055788228714
**
5055788228905
/
**
5055788228943 5055788228745 5055788228776 5055788228806 5055788228837
EVOFRDLINSTR04
IP65
Warranty/Technical and contact
information are all available at
www.integral-led.com
London NW10 0UF
A1
A2
Loop-In-Loop-Out
Neutral(blue)
Live(brown)
Earth(green/yellow)
**Where supplied
To down light
A3
A4
A5
A6
A8A7
2
NL
1 1
1 2
GU10 LED ONLY
MAXIMUM 10W
B1
C1
D1
B2
C2
1
Adapter availableHole > Cut-out?
A2-A8
C3
2
C4
GU10 LED ONLY
MAXIMUM 10W
1
C5
1
x4
Loop-In-Loop-Out
Neutral(blue)
Live(brown)
Earth(green/yellow)
To down light
3.5mm
D4D3D2
72 hours 72 horas 72 heures 72 der dienststuden 72 godzin
2
D6D5
16 hours 16 horas 16 heures 16 der dienststuden 16 godzin
D7
Loop-In-Loop-Out
Neutral(blue)
Live(brown)
Earth(green/yellow)
To down light
D8
GU10 LED ONLY
MAXIMUM 10W
1
2
E1
E2