MLX 300 WATT XENON LIGHT SOURCE

Operation and Service Manual ENGLISH

99 Hartwell Street

West Boylston, MA 01583 USA Tel: +1-508-835-9700

US Toll Free: 1-800-325-8966 Fax: +1-508-835-9976

Website: http://www.integra-surgical.com E-mail: custsvcluxtec@integra-surgical.com

M L X 3 0 0 w a t t x e n o n l i g h t s o u r c e

Table of Contents

Page

Description

2

Indication For Use

3

Symbols

4

General Warnings

4

Precautions

5

Overview

5-6

Operation

6-7

Xenon Lamp Module Replacement

8

Fuse Replacement

9

Optional Floor Stand Assembly

10

Replacement Parts and Accessories

10Maintenance and Cleaning

11Troubleshooting

12Specifications

13-15

Electromagnetic Compatibility (EMC)User Information

16Block Diagram

17Repair and Return

17

Limited Warranty

1

M L X 3 0 0 w a t t x e n o n l i g h t s o u r c e

indication for use

The Luxtec MLX light source is designed to supply high-intensity white light to a fiber optic cable for illumination of a surgical field during a surgical and/or medical procedure.

2

M L X 3 0 0 w a t t x e n o n l i g h t s o u r c e

SYMBOLS

TABLE OF SYMBOLS

Found on a medical grade light source,other illumination related equipment,fiber optic cables and corresponding packaging.

 

 

 

 

Attention; Consult Accompanying Documents

Fuse

 

 

 

 

Caution: High Voltage

Type CF Equipment

 

 

 

 

Equipotentiality

Type BF Equipment

 

 

 

 

Protective Earth

High Temperature

 

 

 

 

On / Off

Brightness

 

 

 

 

Stand-by

Motor

 

 

 

 

System Status Display

Fan

 

 

 

 

System

CE

 

 

 

 

Do Not Dispose

Listed by ETL

 

 

 

 

 

 

 

 

Push

Listed by CSA

 

 

 

 

Hours

Part Number

 

 

 

 

Over Temperature

Batch Code

 

 

 

 

Intensity

Serial Number

or

 

 

 

 

 

 

Authorized Representative in the

 

 

 

 

Lamp

European Community

 

 

 

 

 

Manufacturer

 

 

 

 

Keep dry

 

3

M L X 3 0 0 w a t t x e n o n l i g h t s o u r c e

GENERAL WARNINGS

The user should carefully study the Operation and Service Manual before using the equipment in a clinical environment. Instructions should be followed, with special attention given to warnings,

controls and user specifications.The Manual should be available to the appropriate personnel.

•This Manual contains information about the proper procedures for preparing this product for its use and care.

Before every procedure,carefully inspect the light source to ensure it has been properly maintained and cleaned, and that it is fully functional. DO NOT use if inspection reveals any damage such as case damage or loose connectors.

Follow the instructions of other manufacturer’s equipment when used in conjunction with this product.

To reduce the risk of fire and electric shock,do not expose electrical equipment to moisture.When cleaning, do not immerse any electrical device in liquid.

•Do not use or store liquids on or above the light source.

SAFETY PRECAUTIONS MUSTALWAYS BE

EXERCISED WHEN USING ELECTRICAL EQUIPMENT TO PREVENT OPERATOR/PATIENT SHOCK, FIRE HAZARD OR EQUIPMENT DAMAGE.

Electric shock hazard.If unit is not functioning properly, DO NOT OPEN. Please refer to the Repair and Return Section of this Manual.

All electrical equipment must be used with approved hospital grade power cords and power plugs inserted properly into grounded AC power outlets.

The light source should never be used in ocular surgery or in a surgical procedure requiring direct illumination of the eye.

Use care not to point any fiber optic cable directly at the eye while operating the light source.

The light source produces high intensity light.

Thermal burns can result from improper use of the light source or from the light output of the fiber optic cable.

Explosion Hazard.Do not use in the presence of flammable anesthetics,liquids,vapors,gases or dusts.

Keep cooling vent and fans free of obstructions.

FIRE HAZARD:DO NOT DRAPE OR COVERTHE

LIGHT SOURCE WHILE IT IS OPERATING.

When light source is not in use,turn off the power or put the unit in stand-by mode.

Ensure that the fiber optic cable matches the port type to prevent damaging the optical components of the light source. For user convenience, the light source has a turret with labeled selectable ports.

Do not use the headlight at distances of less than

10” (25cm).

precautions

Take precautions to verify that the fiber optic cable is appropriately suited for the light source. Xenon and other high illumination light sources. require premium fiber optic cables in order to achieve optimal performance and prevent damage to the fibers,thereby diminishing the quality of the light output or the useful life of fiber optic cable.

Take precautions not to touch or disconnect the cable end fitting from the turret until the Light

Source has been “shut down” for a period of time and allowed to cool. The cable end fitting will remain hot immediately following shut down, which can cause burns.

Take precautions to not place and rest a hot cable end fitting and/or head light on a patient or allow the system to come in contact with un-protected hands or tissue. The entire system should be allowed to cool following use. Failure to do so can cause burns and/or tissue damage.

4

M L X 3 0 0 w a t t x e n o n l i g h t s o u r c e

OVERVIEW

The MLX light source delivers 300 spare watts of cool white infrared (IR) filtered light.The lamp is housed in a lamp module that can be easily serviced without special tools.

Set Up and Inspection Before Use

The light source comes with the hospital grade power cord packaged separately. Verify that both components are in good condition.

Before turning power on to the light source, make sure the unit is plugged into any standard 100VAC to 240VAC 4763Hz (as appropriate) outlet. Grounding reliability is guaranteed only when connected to a “hospital grade” receptacle.

Allow a minimum of 2 inches (5.08 cm) clearance at the rear and sides of the unit for cooling air flow. Ensure that the unit is not near air exhaust or against other equipment.

WARNING:The MLX light source monitors air intake temperature and will turn off if ambient temperature is > 40O C

OPERATION

1. Insert a fiber optic cable in the proper port in the turret.The active port is indicated by a on the front panel (See Figure 1). Available ports are ACMI, Olympus, Storz and Wolf cable-compatible. All ports are identified appropriately.

2. Press the Power Switch in the upper left corner of the front panel (See Figure 2).

3.When the Power Switch is pressed the Stand-by Light (Figure 2) will blink and there will be a 3 – 4 second delay before the Xenon Lamp illuminates while the system does a self-diagnostic check.

4. Press the Stand-by Button.

Power Switch

Active Point

Stand-by Button

Figure 1

Figure 2

5