Thank you for choosing the Inta lever operated thermostatic wall mixer.
Subject Page
Introduction 2
Technical Data 2
Components - Wall Mounted 3
Components - Wall Mounted with Removable Spout 4
Components - Deck Mounted 5
Components - Deck Mounted with Removable Spout 6
Dimensions 7
Installation 8
Operation 9
Trouble Shooting 9
Re-calibration 10
Cartridge Removal 10
Aftercare 11
Removing Spout and Disinfection 12
System Flushing Procedure 13
Sterilization Process 14
TMV3 Installation Instructions 16
Guarantee 21
© Intatec Ltd 2016
1
Introduction
This installation guide has been produced for the wall and deck mounted sequential control mixer. These instructions cover the installation, operation and maintenance. Please read the enclosed instructions before commencing the installation of this product, please note;
We recommend that the installation is carried out by an approved installer.
The installation must be carried out strictly in accordance with the Water Supply (Water Fitting) Regulations 1999 and any local authority regulations.
If in doubt we recommend that you contact WRAS - Water Regulations Advisory Scheme on Tel: 0333 207 9030, your local water authority - details available on the WRAS website or the Chartered Institute of Plumbing and Heating Engineers on Tel: 01708 472 791.
All products MUST be re-commissioned to suit site conditions to ensure optimum performance levels of the product are obtained.
Check Content
Before commencing remove all components from packaging and check each component with the contents list.
Ensure all parts are present, before discarding any packaging. If any parts are missing, do not attempt to install your control mixer until the missing parts have been obtained.
Product Range
HTMWMCP - HTM safe touch thermostatic sequential wall mounted tap. HTMDMCP - HTM safe touch thermostatic sequential deck mounted tap. HTMWMRS - HTM safe touch thermostatic sequential wall mounted tap with removable spout. HTMDMRS - HTM safe touch thermostatic sequential deck mounted tap with removable spout.
Technical Data
This Inta thermostatic mixer is suitable for installations on all types of plumbing systems, including gravity supplies, fully pumped, modulating combination boiler, unvented water heater and unbalanced supplies i.e. Cold Mains & Tank Fed Hot.
Max Dynamic Pressure 5 bar Min Operating Pressure 1.0 bar Max Static Pressure 12 bar Min Inlet Temperature 10˚C Max Inlet Temperature 85˚C Temperature Stability ±2˚C Pre Set Factory Temp Setting 41˚C Min Temp Differential to Max Unbalanced Pressure Ratio ensure fail-safe between hot
Without Flow Regulator 5:1 and cold supplies 10˚C
Preparation for Installation
Before starting the installation, ensure that the site conditions are suitable - see Technical Data. The tap is supplied for wall or deck mounting as shown. Flush the water supply pipes thoroughly prior to installation - see page 13. Do not allow debris,
PTFE tape or any metal particles to enter the mixer.
© Intatec Ltd 2016
2
Components - Wall Mounted with Fixed Spout
1
2
3
4
5
6
5
7
8
9
11
13
14
15
15
10
12
Item Description Item Description
1 Body inc. Outlet Diffuser 10 Hot Water Insulator
2 Thermostatic Cartridge
3 Lever
4 Lever Retaining Screw
5 Concealing Plate
6 Cold Water Inlet Tail Assembly 13 Hot Water Port Blanking Assembly
7 Hot Water Inlet Tail Assembly 14 Cold Water Port Blanking Assembly
8 Sealing Washer 15 Backnut
9 Swivel Nut
Cold Water Inlet Assembly
11
including 5 l/m flow regulator
Hot Water Inlet Assembly
12
including 5 l/m flow regulator
© Intatec Ltd 2016
3
Components - Wall Mounted with Removable Spout
1
2
3
4
5
6
5
7
8
9
11
13
14
15
15
10
12
17
18
19
Additional Components - Removable Spout
Item Description Item Description
1 Body 18 Spout Retaining Screw
17 Spout 19 ‘O’ Ring
© Intatec Ltd 2016
4
Components - Deck Mounted with Fixed Spout
1
2
3
4
11
6
5
8
9
7
5
13
14
16 15
10
12
Item Description Item Description
1 Body inc. Outlet Diffuser 10 Hot Water Insulator
2 Thermostatic Cartridge
3 Lever
4 Lever Retaining Screw
5 Concealing Plate
6 Cold Water Inlet Tail Assembly 13 Hot Water Port Blanking Assembly
Cold Water Inlet Assembly
11
including 5 l/m flow regulator
Hot Water Inlet Assembly
12
including 5 l/m flow regulator
7 Hot Water Inlet Tail Assembly 14 Cold Water Port Blanking Assembly
8 Sealing Washer 15 Backnut
9 Swivel Nut 16 Washer - Chrome
© Intatec Ltd 2016
5
Components - Deck Mounted with Removable Spout
1
2
3
4
11
6
5
8
9
7
5
13
14
16 15
10
12
17
18
19
Additional Components - Removable Spout
Item Description Item Description
1 Body 18 Spout Retaining Screw
17 Spout 19 ‘O’ Ring
© Intatec Ltd 2016
6
Dimensions - Wall Mounted
37
G½B
12875 105
186.5
Ø45
266
116.5
Ø50 Ø33
75
187.5
200
G½B
Ø50
Ø33
100
Dimensions - Deck Mounted
© Intatec Ltd 2016
7