Quick Installation Guide
MRX LAN
www.insys-icom.com
These short operating instructions apply for the following devices of INSYS icom:
www.insys-icom.com/manual
It is intended for a quick commissioning by the operator. Refer to the associated manual for further information.
This and other associated manuals can be found on our website in the menu Support and Downloads >
Documentation. Scan the QR code above or enter the URL into your web browser.
Te c hnical Data
The product is only intended for the use within the permissible technical limits specified in the data sheets. These limits must be observed.
Operating voltage (redundant)
Real-time clock (RTC) buffer time
typ. 2.0 W, max. 3.0 W
fully equipped: max. 20 W
-30 °C … 70 °C
(75 °C extended)
HIGH level = 2 ... 24 V
LOW level = 0 ... 1 V
Contact open condition: HIGH
Maximum permissible humidity
95% non-condensing
Current consumption input IN1
at LOW potential
typ. 0.1 mA when connecting to
GND
HIGH level = 10 ... 24 V
LOW level = 0 ... 5 V
Contact open condition: LOW
Power consumption input IN2
at HIGH potential
Te c hnical Boundaries
Max. line length for antennas, power supplies, serial interfaces, inputs and outputs as well as other signals: 30 m
Max. line length of USB connection lines: 3 m
Cable cross-section: 0.25 … 1.5 (2.5) mm² (depending on terminal size), flexible lines require end sleeves
Su pport
If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e-mail
under support@insys-tec.de.
De fects liability terms
A use other than the intended use, an ignorance of the safety instructions and the documentation, the use of insufficiently q ualified
personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resulting from this. The liability of the
manufacturer ceases to exist.
In tended Use
The product may only be used for the purposes specified in the function overview of the manual. In addition, it may be used for the
following purposes:
▪ Usage and mounting in an industrial cabinet.
▪ Switching and data transmission functions in machines according to the machine directive 2006/42/EC.
▪ Usage as data transmission device, e.g. for a PLC.
The product may not be u sed for the following purposes and used or operated under the following conditions:
▪ Use, control, switching and data transmission in machines or systems in explosive atmospheres.
▪ Controlling, switching and data transmission of machines, which may involve risks to life and limb due to their functions or when a
breakdown occurs.
![](/html/81/819e/819efbed772751f385b2212df64f58b0c235196838c7e915f00210256ff31077/bg2.png)
ENGLISH
Quick Installation Guide
MRX LAN
www.insys-icom.com
Router connection
1. Connect supply voltage (12 V … 24 V DC (±20%))
to the terminals V+1 and GND
2. Connect router (ETH 1) to the configuration PC
via Ethernet cable
3. Connect router (ETH 2) to the network
in which your system is located
4. Connect router (ETH 5) to the network
that is used to establish the Internet connection
LAN settings of configurations PC (Windows 7)
If a DHCP client is active on the PC, proceed with step C. Otherwise, either enable the
DHCP client or configure a static IP address.
5. Open Network and Sharing Center (e.g. key and search for "sharing")
6. Select LAN connection and Properties
7. Select Internet Protocol Version 4 (TCP/IP) and Properties
Enable DHCP client
8. Obtain an IP address automatically
It is recommended to unplug the
network cable briefly and plug it
again upon activation of the DHCP
client.
Configure a static IP address
Use the following IP address (example):
IP address: 192 . 168 . 1 . 2
Subnet mask: 255 . 255 . 255 . 0
Standard gateway 192 . 168 . 1 . 1
Preferred DNS server: 192 . 168 . 1 . 1
Please note the previous values before
changing the TCP/IP settings to be able
to restore them later.
Web interface access
9. Enter IP address of the router in address bar of the browser
(default: 192.168.1.1)
If a proxy server is enabled in your browser, this must be disabled or the IP address of
the router must be added as exception.
10. Login with
Name
(default: insys) and
Password
(icom)
11. Open the Inline Help using the button (Display help text) in the header
The links in the Inline Help lead to the Online Help with further information.
All modified data will only be stored in the opened profile after clicking the
Save
settings
button and become effective upon clicking the (Activate profile) button.