InstruStar ISDS205 User Manual

InstruStar Electronic Technology http://www.instrustar.com/
ISDS205
1
InstruStar Electronic Technology
2019-02-25
InstruStar Electronic Technology http://www.instrustar.com/
ISDS205
2
contents
1.Introduction…………………………………………………………1
2.Feature Description…………………………………………………1
3.Software Installation…………………………………………………2
4.Interface………………………………………………………………3
5.Oscilloscope / Spectrum Analyzer/DDS……………………………5
6.Data Recorder…………………………………………………………5
7.Logic Analyzer………………………………………………………5
8.Saleae Logic Logic Analyzer…………………………………………6
InstruStar Electronic Technology http://www.instrustar.com/
ISDS205
3
PC SYSTEM REQUIREMENTS
Windows XPWin7Win8Win10 Pentium or higer processor USB2.0 High speed port. 512MB RAM
1GB hard disk space
InstruStar Electronic Technology http://www.instrustar.com/
ISDS205
4
1.Introduction
ISDS205 dual-channel digital oscilloscope, with "low-cost, high-performance" as the design goals. well-designed bandwidth of 16M, 48M sampling rate, 2 channels, alternating support X-T and XY alternating pattern of two-channel virtual oscilloscope, spectrum analyzer, data recorder.
205C and 205X support logic analyzer. Logic analyzer support our Logic software and Saleae Logic 2 kinds of software, Saleae Logic supports SPI, IIC, UART, etc. 17 kinds protocol analysis.
205B and 205X support DDS function. DDS support 5 kinds of waveform output,
Sine wave can output up to 20M.
2.Feature Description
Digital Oscilloscope
Channels
2
Impedance
1MΩ 25pF
Coupling
AC/DC
Vertical Resolution
8Bit
Gain Range
-5V ~ 5Vprobe X1
-50V ~ 50Vprobe X10
Vertical Accuracy
±3%
Time Base Range
10ns/div-100ms/div
Input Protection
Diode50Vpk
Auto Set
Yes(10Hz to 10MHz)
Trigger Mode
AutoNormal and Signal
Trigger Type
No、Rising edge、Falling edge
Rising edge or Falling edge
Trigger Level
Yes
Trigger Source
CH1, CH2
Buffer Size
1MB/CH
Bandwidth
16MHz(Max 20M)
Max Sample
48MS/s
Oscilloscope
Spectrum Analyzer
Data Recorder
Logic Analyzer
DDS
ISDS205A √ √ √
ISDS205B √ √ √
ISDS205C √ √ √ √
ISDS205X √ √ √ √
InstruStar Electronic Technology http://www.instrustar.com/
ISDS205
5
Vertical Mode
CH1, CH2, ADD, SUB, MUL
Display Mode
XY-T X-Y
Measurements
Yes
Wave Save
Osc(Private)Excel and Bmp
Spectrum Analyzers
Channels
2
Bandwidth
16MHz
Algorithm
FFT(18 windows)correlation
FFT Points
8-1048576/CHN
FFT Measure
Harmonic(1-7)、SNR、SINADENOBTHD、SFDR
Filter Process
FIR filter supports arbitrary range of frequency sampling method , and Rectangle, bartlett, triangular, cosine, hanning, bartlett_hanning, hamming, blackman, blackman_Harris, tukey, Nuttall, FlatTop, Bohman, Parzen, Lanczos, kaiser, gaussand dolph_chebyshev, window method design. IIR filter support "Butterworth", "Chebyshev I", "Chebyshev II", "Elliptic" type of filter design
Note: 1, The oscilloscope factory calibration, if you are not satisfied with the measurements, can manual calibration, the specific reference oscilloscope instructions. 2, Oscilloscope with probe: X1 can measure -5V to +5V voltage, X10 can measure
-50V to +50V. 3, The measurement of the electric supply 220V/110V is different from the normal waveform measurement and needs to be re-measured by an isolated transformer.
Data Recorder
Channel
2
Impedance
1MΩ 25pF
Coupling
AC/DC
Vertical Resolution
8Bit
Gain Range
-5V ~ 5Vprobe X1
-50V ~ 50Vprobe X10
Sample
1 channel : 1K~24M Hz 2 channel : 1K~16M Hz
Save File
The maximum 4G, recording time associated with the
sampling rate
InstruStar Electronic Technology http://www.instrustar.com/
ISDS205
6
Note: The specific speed recorder with computer processing speed, and if use high sampling rate, the situation may break.
Logic Analyzer(205C/205X)
Channel
16
Sample
8 channel: 250K~24M Hz
16 channel: 250K~16M Hz
Sample Points
1M-2GB
Saleae Logic Logic Analyzer (205C/205X)
Channel
8
Sample
25K~24M Hz
Protocol Analyzer
Atmel SWIBiSS CSPII2C、CAN、UART、
I2S/PCMDMX-512JTAGLINManchester
1-WIRE、UNI/OSimple ParallelMDIO、USB1.1
PS/2 Keyboard/Mouse
Sample Points
1MB~10TB
3.Software Installation
Please refer to the "Software and Driver Installation.pdf".
DDS(205B/205X)
Wave
Sine, Square(Duty circle variable),Triangle,Up
Sawtooth,Down Sawtooth
Amplitude
9Vp-p(no load)
Impedance
200Ω±10%
Offset
±2.5V
Frequency Range
1Hz ~ 20MHz(Sine), 1Hz ~ 2MHz(Others)
Frequency Resolution
1Hz
Frequency Steadiness
±1×10-3
Frequency Precision
±5×10-3
Triangular Wave Linearity
98% (1Hz~10kHz)
Sine Wave Distortion
0.8% (1kHz)
Square Wave Rising/Falling Time
≤100ns
Square Wave Duty Circle
1%~99%
Sweep
Sweep Range
Fs Fe
Sweep Time Range
0.1 ~10 s
Amplitude
0.5Vp-p ~ 10Vp-p
InstruStar Electronic Technology http://www.instrustar.com/
ISDS205
7
4.Interface
4.1 ISDS205A
Oscilloscope
CH1 channel
Oscilloscope
CH2 channel
Benchmark 1K
2Vpp square wave
Power Led USB
4.2 ISDS205B
Oscilloscope
CH1 channel
Oscilloscope
CH2 channel
Benchmark 1K
2Vpp square wave
DDS Output
Power Led
USB
DDS Amplitude adjust DDS Bias adjust
4.3 ISDS205C
InstruStar Electronic Technology http://www.instrustar.com/
ISDS205
8
Oscilloscope
CH1 channel
Oscilloscope
CH2 channel
Logic Analyzer interface
Benchmark 1K
2Vpp square wave
Power Led USB
Saleae Logic
Multi VirAnalyzer Switch
4.4 ISDS205X
Oscilloscope
CH1 channel
Oscilloscope
CH2 channel
Benchmark 1K
2Vpp square wave
DDS Output
Power Led USB
Saleae Logic
Multi VirAnalyzer Switch
Logic Analyzer interface
5.Oscilloscope / Spectrum analyzer/DDS
Please refer to the "Multi VirAnalyzer User Guide.pdf", "Digital storage oscilloscope
(Professional Version).pdf" and "Digital storage oscilloscope (Simplified Version).pdf".
6.Data Recorder
Please refer to the "Data Recorder.pdf".
7.Logic Analyzer
After the success of USB devices, data recoder, equipment
selection drop-downcombo box will appear ISDS205C/X(1.0) (N) option, choose a good future, the interface in Figure 7.1.
InstruStar Electronic Technology http://www.instrustar.com/
ISDS205
9
7.1 Basic control
7.1.1 Channel Control
Start or Stop Capture.
7.1.2 Channel Num
Set the num of the channels to be collected.
7.1.3 Sample Length
Set the length of the data to be collected.
7.1.4 Sample
Select the speed of data collection.
7.2 Record
Click the lower right corner "data record", the interface
appears in Figure 6.2. Can display the recorded file. Double click the corresponding file, you can
load, view the collected data.
8.Saleae Logic Logic Analyzer
The device to support Saleae Logic software, the development of the hardware above appropriated Saleae Logic position. Plugged into the USB, the software automatically recognizes and displays the Connected. Interface shown in Figure 8.1
More information, please view Saleae Logic software instructions, is located in "\Saleae
Logic\Logic Guide.pdf"
Figure 7.2 data record
Figure 7.1 properties
Figure 8.1 Saleae Logic interface
Loading...