Instrument Transformer, Div of GE JAK-0S RevenueSense Data Sheet

GE
Grid Solutions
Model JAK-0S RevenueSenseTM
Revenue Metering Current Transformer
Application
Features
Voltage Class: 0.6 kV
Frequency: 50-60 Hz
Window Size: 3.062”
Insulation Level: 10 kV BIL
Application: Indoor/Outdoor
Benefits
Maximize revenue metering accuracy with special high accuracy rating
extended beyond IEEE requirements
Simplify CT selection and billing multipliers, improving productivity and
minimizing risk of error
Reduce inventory and part number requirements, reducing asset and
operational costs
(1) Exceeds IEEE definition for special high accuracy. Maintains 0.15 Accuracy from1 % to Rating Factor. (2) Wide-base and secondary conduit box options available, upon request. Contact GE for more details. (3) Other designs available, upon request. Contact GE for more details.
JAK-0S
the bar; the other has a slot allowing it to be slipped over the bar where it
The case is molded with GE Valox thermoplastic polyester resin. This tough
The core is manufactured with high-efficiency material that reduces energy
Weight & Dimensions
Construction and Insulation
The core and coil assembly is encapsulated in resin within a molded case.
material has excellent electrical and mechanical properties over a wide temperature range, has low water absorption and is resistant to oil and a variety of chemicals. The polyurethane resin filling completely encapsulates the winding, leads and terminals to form a waterproof unit.
Core and Coils
losses, allowing for higher accuracy over a wider range. The secondary winding is made of heavy enameled copper wire evenly distributed around the core for maximum accuracy and resistance to stray fields from adjacent conductors.
Terminals
Secondary terminals are tin plated brass, compression type with a 0.275” diameter cross-hole for wiring and a 1/4-28 clamp screw. A shorting device is provided and interlocked to the terminal cover. The terminal cover is made of a clear plastic. Provision is made for sealing the cover.
Polarity
The H1 polarity mark is indented into the body, above the window at one end. The X1 polarity mark is also molded into the body adjacent to the secondary terminal. Both marks are white for visibility.
Nameplates
The nameplate is laser engraved aluminum. It is attached to the top of the unit and has provision for attaching the user’s identifying tag. The nominal current rating is marked on the side of the unit in large numerals.
Primary Bars (Optional)
Formed from flat copper bar, they are tin-plated. They can be supplied mounted to the transformer, or separately for assembly into window­type units; they can be rotated to bring the terminal pads into any orientation. The bar is supported and held in place by two end plates, which act as small animal barriers. One plate is permanently attached to
is held in place by two setscrews. Holes in the plate allow ventilation and drainage of any water which might accumulate in the window. A potential connector is provided, adjacent to the fixed end plate.
Baseplate and Mounting
The transformer can be mounted in any position and may be suspended from the bus-bar or cable. It has provision for attaching three optional bases. Bases are made from stainless steel. The high base increases the transformer height to provide interchangeability with 600 V bar-type current transformers.
Maintenance
These transformers require no maintenance, other than occasional cleaning, if installed where air contamination is severe.
ITI-Model-JAK-OS-RS-Spec-EN-2017-11-Grid-AIS-1390. © Copyright 2017. General Electric Company and Instrument Transformers LLC reserve the right to change specifications of described products at any time without notice and without obligation to notify any person of such changes.