Instrument Transformer, Div of GE JAH-0C Data Sheet

GE
Grid Solutions
Model JAH-0C 600 V
Indoor Current Transformer, 10 kV BIL, 200 - 4,000 A Window Diameter 4.00”/5.75”
Application
Designed for indoor service. Suitable for operating meters, relays and control devices, on circuits not exceeding 600 V line-to-line. It may be used on higher voltage circuits with an insulated conductor. Refer to the Applications Information section of catalog GEP-9186.
Regulatory Agency Approvals
UL Recognized File ........................E93779
Weight
(approximate)
Transformers with 4.00” window.........11 lbs
Transformers with 5.75” window........9.5 lbs
Reference Drawings
Outline ......0121C33700
Insulation Level
0.6 kV; BIL 10 kV full wave.
Frequency
50-60 Hz
JAH-0C Dimensions
compartments, which cannot be opened while the transformer is
Primary and secondary polarity marks H1 and X1 are molded into
Construction and Insulation
The core and coil are enclosed in a case molded with GE Valox thermoplastic polyester resin. This material has excellent electrical and mechanical properties over a wide temperature range, and is resistant to oil and a variety of chemicals.
Core and Coils
The core is made from high quality grain oriented silicon steel, annealed under rigidly controlled factory conditions. The secondary winding is made of heavy enameled copper wire. The secondary windings are evenly distributed around the core for maximum accuracy and resistance to stray fields from adjacent conductors.
Terminals
Secondary terminals are No. 8-32 brass studs with one flatwasher, one lockwasher and a regular nut. Because the transformer is used primarily in enclosed switchgear
energized, a secondary shorting device and terminal cover are not provided.
Polarity
the case.
Primary Conductor
A bus or insulated cable forms the primary winding.
Nameplates
The nameplate is a polyester label attached to the face of the transformer.
Mounting
The transformer can be mounted in any position. An optional mounting bracket kit (part number 0021B00185) is available. This kit must be ordered separatley if required.
Maintenance
These transformers require no maintenance, other than occasional cleaning, if installed where air contamination is severe.