Instrument Transformer, Div of GE JAD-AC 600V Data Sheet

GE
...............13
Type........17
Grid Solutions
Model JAD-AC 600V
High Accuracy Indoor/Outdoor Current Transformer 10 kV BIL, 800-4000 A Window Diameter 5.75”
Application
Designed for both indoor and outdoor service. Suitable for operating meters, instruments and control devices. For use on higher voltage circuits with an insulated primary conductor, please refer to the Applications Information section of catalog GEP-9186.
Regulatory Agency Approvals
UL Recognized ............File E93779
Weight (Approximate)
Transformer, Window Type
lbs Transformer, Primary-Bar lbs
Mounting Base, add ................................2 lbs
Insulation level
0.6 kV; BIL 10 kV full wave
Reference Drawings
Single Ratio Outline 0121C34994 Dual Ratio Outline 0121C35099
Bar Assembly 11 7/8”
1 Bar 0821C35021-1 2 Bar 0821C35021-2 3 Bar 0821C35021-3 4 Bar 0821C35021-4
Bar Assembly 14 1/2”
1 Bar 0821C35021-7 2 Bar 0821C35021-8 3 Bar 0821C35021-9 4 Bar 0821C35021-10 Base Assembly 0221A36647 Flushmount Bracket Kit 0221A38343
Frequency
50-60 Hz
water absorption and is resistant to oil and a variety of chemicals.
Secondary terminals are tin plated brass, compression type with a
0.275” diameter cross-hole for wiring and a 1/4-28 clamp screw. A
The terminal cover is made of a clear plastic. Provision is made for
A secondary conduit box, in place of the secondary terminal block,
These transformers require no maintenance, other than occasional
JAD-AC Dimensions
Construction and Insulation
The core and coil assembly is encapsulated in resin within a molded case. The case is molded with GE Valox thermo- plastic polyester resin. This tough material has excellent electrical and mechanical properties over a wide temperature range, has low
The polyurethane resin filling completely encapsulates the winding, leads and terminals to form a waterproof unit.
Core and Coils
The core is made from high quality grain oriented silicon steel, annealed under rigidly controlled factory conditions. The secondary windings are evenly distributed around the core for maximum accuracy and resistance to stray fields from adjacent conductors.
Terminals
shorting device is provided and interlocked to the terminal cover.
sealing the cover.
Conduit Attachment
is available. It is suitable for outdoor applications. Box and cover are made of aluminum with a black finish. The cover has a gasket and four sealable thumbscrews. Two boxes are required for dual ratio transformers.
Polarity
Primary and secondary marks H1 and X1 are molded into the case.
Primary Conductor
Removable primary bars are formed from 1/4” X 4” tin-plated, flat copper bar, with 1/4” spacing between bars on multiple bar assemblies. The bars are retained by insulated and ventilated end caps, which permit the bars to be rotated to any desired orientation and allow the transformer to be supported in a vertical primary arrangement. A potential connector is provided adjacent to one end cap. Primary bars are available in 11 7/8” and 14 1/4” lengths, each provided with four bolt holes at each end.
Nameplates
The nameplate is laser engraved aluminum. It is attached to the top of the unit and has provisions for attaching the user’s identifying tag. The nominal current rating is marked on the side of the unit in large numerals.
Baseplate and Mounting
The transformer can be mounted in any position. An optional baseplate is available, made of stainless steel plate. It is attached to the transformer with two bolts.
Maintenance
cleaning if installed where air contamination is severe.
Grid-AIS-L4-ITI_Model_JAD_AC-1386-2017_07-EN. General Electric Company and Instrument Transformers LLC reserve the right to change specifications of described products at any time without notice and without obligation to notify any person of such changes.