INSTEON 2633-432, 2633-442, 2633-422, 2633-522, 2633-452 User Manual

On/Off Module
2633-442
(UK)
2633-522
(Aus/NZ)
2633-422
(France)
2633-432 (Germany)
2633-452 (Chile)
Owner’s Manual
2633-422 (France) 2633-432 (Germany) 2633-442 (UK) 2633-452 (Chile) 2633-522 (AUS/NZ)
Page 1 of 14 Rev: 1/21/2014 7:47 AM
LED
Paddle top
Paddle bottom
(off)
Set button
TABLE OF CONTENTS
About On/Off Module .................................................................................................................................. 2
Features and Benefits ............................................................................................................................... 3
Installation ................................................................................................................................................... 3
Using On/Off Module Paddle...................................................................................................................... 4
Adjust Local Settings ................................................................................................................................. 4
Change LED Brightness (or turn it off) ...................................................................................................... 4
Error Blink .................................................................................................................................................. 4
Blink on Traffic ........................................................................................................................................... 4
Beep on Button Press ................................................................................................................................ 5
INSTEON Setup ........................................................................................................................................... 5
INSTEON Controllers, Responders and Links .......................................................................................... 5
Configure INSTEON Settings .................................................................................................................... 5
Make On/Off Module a Responder ............................................................................................................ 5
Make On/Off Module a Controller .............................................................................................................. 6
Groups ....................................................................................................................................................... 6
Scenes ....................................................................................................................................................... 6
Make On/Off Module a Controller of Multiple Responders ........................................................................ 7
Remove On/Off Module as a Controller .................................................................................................... 7
Remove On/Off Module as a Responder .................................................................................................. 7
Remove On/Off Module as a Controller of Multiple Responders .............................................................. 8
Factory Reset ............................................................................................................................................ 8
X10 Setup ..................................................................................................................................................... 8
Add X10 Address ....................................................................................................................................... 8
Remove X10 Address ................................................................................................................................ 8
Specifications .............................................................................................................................................. 9
All product specifications are subject to change. ................................................................................. 11
Troubleshooting ........................................................................................................................................ 11
Phase Bridge Detect Beacon/RF Range Test ......................................................................................... 12
Certification and Warranty ....................................................................................................................... 13
DECLARATION OF CONFORMITY ........................................................................................................ 13
Limited Warranty ..................................................................................................................................... 14

About On/Off Module

INSTEON On/Off Module makes adding customizable INSTEON (and X10) remote control to your lamps and appliances as easy as plug and play. It’s home automation at its simplest and most convenient.
(on)
Page 2 of 14 Rev: 1/21/2014 7:47 AM
In the Box
Tools Needed
Optional Accessories
On/Off Module
None
INSTEON Hub
Quick Start Guide
Mini Remote

Features and Benefits

- Integrated on/off relay
- Compatible with all INSTEON (and X10) controllers; can also act as an INSTEON (and X10) controller
- Super-easy setup with multi-color LED and beeper
- Dual-band communicates simultaneously over both RF and powerline
- Stores setup state in non-volatile memory so settings aren’t lost during power outages
- Two-year warranty

Installation

CAUTIONS AND WARNINGS
Read and understand these instructions before installing and retain them for future reference. This product is not designed or approved for use on powerlines other than 100-240VAC,50Hz or 60Hz, single phase. Attempting to
use this product on non-approved powerlines may have hazardous consequences.
- Use only indoors or in outdoor rated box
- This product may feel warm during operation. The amount of heat generated is within approved limits and poses no hazards. To minimize heat buildup, ensure the area surrounding this product is as clear of clutter as possible.
- Each INSTEON product is assigned a unique INSTEON I.D., which is printed on the product’s label.
- To reduce the risk of overheating and possible damage to other equipment, do not use this product to control loads in excess of the specified maximum(s) or, install in locations with electricity specifications which are outside of the product’s specifications. If this device supports dimming, please note that dimming an inductive load, such as a fan or transformer, could cause damage to the dimmer, the load bearing device, or both. If the manufacturer of the load device does not recommend dimming, use a non-dimming INSTEON on/off switch. USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD.
IMPORTANT! If you have any difficulties or questions, consult an electrician. If you are not knowledgeable about, and comfortable with, electric al circuitry, you should have a qualified electrician install the product for you.
1) Turn on lamp or appliance
2) Unplug lamp/appliance and plug it into On/Off Module receptacle
3) Plug On/Off Module into unswitched wall outlet
Load will turn on On/Off Module LED will turn green
Page 3 of 14 Rev: 1/21/2014 7:47 AM
On/Off Module Paddle
Tap
Press and hold
Double-tap
LED

Using On/Off Module Paddle

On/Off Module’s paddle will control the load and any additional linked responders with tap, double-tap and press and hold actions to initiate different behaviors.
Top
On
Brighten
until release or 100%
(dimmable responders only)
Instant full-on Green
Dim
Bottom
Off
until release or off
(dimmable responders only)
Instant full-off Red

Adjust Local Settings

Change LED Brightness (or turn it off)

Default = 50% brightness level
1) Press and hold On/Off Module set button until it beeps
LED will start blinking green
2) Press and hold On/Off Module set button until it beeps a second time
LED will start blinking red
3) Press and hold On/Off Module set button until it beeps a third time
LED will start blinking green
4) Tap On/Off Module set button once
LED starts double-blinking green
5) Press and hold On/Off Module set button until it beeps
LED will turn green (at brightness of connected load)
6) Use the On/Off Module’s paddle to brighten or dim LED to des ired br ig htn es s
7) Tap On/Off Module set button to accept
On/Off Module will double-beep and return to ready mode

Error Blink

Default = enabled This setting is only adjustable via software or a central controller. On/Off Module LED will blink red once if
one or more responders do not acknowledge a message and will blink green once if all responders are successful.

Blink on Traffic

Default = disabled This setting is only adjustable via software or a central controller. DIN Rail module LED will blink red if it
detects noise that could disrupt communication.
Page 4 of 14 Rev: 1/21/2014 7:47 AM
Controller
Responder
Link

Beep on Button Press

Default = disabled This setting is only adjustable via software or a central controller. On/Off Module will beep every time its
paddle is tapped.

INSTEON Setup

Some products have subtle differences in their setup procedures. Please refer to the other devices’ owner’s manuals for details.

INSTEON Controller s, R es pon der s and Li nk s

Let’s define a few terms.
The INSTEON “transmitter” is called a controller
The INSTEON “receiver” is called a responder
The association between the controller and responder is called a link
Note that a link is one way. If you wish to have control “the other way,” simply add a link “the other way.”

Configure INSTEON Settings

Most On/Off Module links and settings can be configured locally—during installation with the module’s set button or after installation using the switch connected to the module—or remotely via software (sold separately).
All On/Off Module settings can be managed remotely via software (sold separately).

Make On/Off Module a Responder

1) Press and hold controller set button until it beeps
Controller LED will start blinking green You will have four minutes to complete the next steps before linking mode times out
2) Turn on load connected to On/Off Module and adjust to desired le vel (on or off)
3) Press and hold On/Off Module set button until it double-beeps
Controller will double-beep and its LED will stop blinking
4) Test link by tapping controller button on and off or pressing and holding to brighten/dim
Load connected to On/O ff Modu le will respond appropriately
Note:
- The link just created is one way. See Make O n/O ff Modul e a Controller or Groups link to keep the two products in sync.
- If you wish the load to be off when link is activated—such as for an “all off” scene—turn off the load in step #2.
to add another
Page 5 of 14 Rev: 1/21/2014 7:47 AM