INSTEON® 240V 30 Amp Load Cont roller (Dual-Band)
2477SA2 (Normally Closed)

240V Load Controller Owner’s Manual
240V Load Controller Owner’s Manual
TABLE OF CONTENTS
ABOUT 240V LOAD CONTROLLER ........................................................................................................... 3
Key 240V Load Controller Features .......................................................................................................... 3
WHAT IS INSTEON? .................................................................................................................................... 4
INSTALLATION ............................................................................................................................................ 5
Tools You Will Need .................................................................................................................................. 5
Preparing to Install 240V Load Controller ................................................................................................. 5
Installing 240V Load Controller ................................................................................................................. 6
USING 240V LOAD CONTROLLER ............................................................................................................ 6
CONTROLLING 240V LOAD CONTROLLER FROM AN INSTEON CONTROLLER ................................ 7
Linking an INSTEON Controller to 240V Load Controller ......................................................................... 7
Unlinking 240V Load Controller from an INSTEON Controller .................................................................. 7
CONTROLLING INSTEON RESPONDERS FROM 240V LOAD CONTROLLER ...................................... 8
Linking 240V Load Controller to an INSTEON Responder ....................................................................... 8
Unlinking an INSTEON Responder from 240V Load Controller................................................................ 8
CREATING AN INSTEON SCENE ............................................................................................................... 9
ADVANCED FEATURES ............................................................................................................................. 9
Restoring Power to 240V Load Controller ................................................................................................. 9
Resetting 240V Load Controller to its Factory Default Settings ................................................................ 9
X10 PROGRAMMING OPTIONS ............................................................................................................... 10
Setting the X10 Address .......................................................................................................................... 10
Removing the X10 Address ..................................................................................................................... 10
ABOUT INSTEON ...................................................................................................................................... 10
Using Dual-Band INSTEON Devices to Upgrade Your Network ............................................................. 10
Important Note about INSTEON Networks; Split Single-Phase vs. 3-Phase Installation........................ 11
Further Enhancing Reliability .................................................................................................................. 11
ADDITIONAL RESOURCES ...................................................................................................................... 11
TROUBLESHOOTING ................................................................................................................................ 11
SPECIFICATIONS, CERTIFICATION, AND WARRANTY ........................................................................ 13
Specifications .......................................................................................................................................... 13
Certification .............................................................................................................................................. 13
FCC and Industry Canada Compliance Statement ................................................................................. 13
Limited Warranty ..................................................................................................................................... 14
Page 2 of 14

240V Load Controller Owner’s Manual
ABOUT 240V LOAD CONTROLLER
240V Load Controller lets you effic iently contro l the us e of heav y-duty appl iances to save energy and cut
down on utility costs. Remotely control your appliances that run on higher voltages, up to 30 Amps
(resistive loads only).
Key 240V Load Controller Features
• After installation, setup is easy – installs and links to other INSTEON devices in minutes
• Controls high-voltage appliances up to 240 Volts, 30 Amps, split-single phase (resistive loads only)
• Communicates simultaneously over both radio frequency (RF) and the power line
• Acts as an access point for RF-only devices
• Indicates INSTEON s etup mode activity and operatio nal states with a Load Active L ED, dual-color
Status LED and beeper
• Does not require a Neutral connection
• Set button functions as an On/Off toggle switch for the attached load
• Stores setup state in non-volatile memory so settings aren’t lost during power outages
• Two-year warranty
Page 3 of 14

240V Load Controller Owner’s Manual
WHAT IS INSTEON?
Since its inception in 2 005, INST EON has bec om e the in dustr y gold standar d in home-control networking
technology, offering more reliability and flexibility than any other home management system on the
market. INSTEON is simple, r eliab le and af f or dable.
• Simple: each device takes just minutes to install.
• Reliable: every INST EON device works as a network repeater, ens uring your com mands will not
be lost.
• Affordable: INST EON c an be i ntegra ted int o an y number of devices easil y and at a ver y low cost.
An INSTEON home grows in value with each added INSTEON device, making life more
convenient, safe and fun.
How Does INSTEON Work?
What make s INSTEON the most reliable home autom ation network is its dual-mesh network . INSTEON
devices use both radio frequenc y (RF) signals and the hom e’s existing wiring to talk to eac h other. In an
INSTEON network, every INSTEON device also acts as a repeater, receiving and sending every
message to all other devices in the network. So by integrating more INSTEON devices you will strengthen
the network and ensure no commands will be lost.
No central controller or networking setup is required with an INSTEON network. Simply install your
devices and then use a series of button presses or t aps to link your devices together. T hroughout this
Owner’s Manual, you may s ee the term s “controller” or “responder.” T hese gener ic INST EON term s refer
to the components of an INSTEON scene, and are used on a scene-by-scene basis.
• Controller – sends INSTEON commands to other devices
• Responder – reacts to commands sent out by another INSTEON device
An INSTEON device may act as a controller, responder or sometimes both.
INSTEON networks are also extr emely secure. Each INSTEON device is assig ned a unique INSTEON
I.D., so unless neighbors or would-be hackers have access to your particular device’s INSTEON I.D., they
won’t be able to control your home, even if they are using similar products.
Page 4 of 14

240V Load Controller Owner’s Manual
INSTALLATION
Tools You Will Need
• Screwdriver (to remove the cover of the junction box)
• Wire cutter/stripper
• Various tools to wall-mount 240V Load Controller
Preparing to Install 240V Load Controller
CAUTION
Read and understand these instructions before installing and retain them for future reference.
240V Load Controller is intended for installation in accordance with the National Electric Code and local regulations in
the United States or the Canadian Electrical Code and local regulations in Canada. Use indoors only. 240V Load
Controller is not designed nor approved for use on power lines other than 120V 60Hz, single phase. Attempting to
use 240V Load Controller on non-approved power lines may have hazardous consequences.
Prior to installing 240V Load Controller, please review the entire installation procedure and take the following
precautions:
• Because 240V Load Controller involves high voltage levels, it is recommended that installation be performed
only by a qualified electrician or by a homeowner who is extremely knowledgeable and familiar with
electrical circuitry. Please take an extra level of precaution when installing this device. If you have any
questions regarding installation, please consult an electrician.
• 240V Load Controller must be connected to a 2-pole tandem circuit breaker, rated for no more than 30
Amps. 240V Load Controller does not have over-current protection and therefore must be connected
through a circuit breaker.
• Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are installing
240V Load Controller in. Installing 240V Load Controller with the power on will expose you to dangerous
voltages.
• Connect only copper or copper-clad wire to 240V Load Controller
• 240V Load Controller may feel warm during operation. The amount of heat generated is within approved
limits and poses no hazards. To minimize heat buildup, ensure that the area surrounding the rear of 240V
Load Controller has adequate ventilation by clearing away excess insulation.
• Don’t use 240V Load Controller to control devices that preserve, maintain, or contribute to human or animal
safety or life support
• Don’t bury 240V Load Controller or any electrical cable or components connected to it. A buried power cord
may result in electrocution if improper cables are used or if digging occurs over the cable.
• Don’t allow vegetation to grow on or around 240V Load Controller
• Don’t install 240V Load Controller in a manner that allows water to accumulate around the unit
• Don’t attempt to open 240V Load Controller. The 240V Load Controller case is sealed and can’t be opened.
There are no user-serviceable parts inside.
• Each 240V Load Controller is assigned a unique INSTEON I.D., which is printed on the device’s lab el. It is
recommended that you prepare a list of all the devices you are installing, including their INSTEON I.D. and
their location (e.g., 01.F7.G5, Mike’s bedroom light). It is only necessary to know the INSTEON I.D.s if you
will be using optional automation software (such as Smarthome’s HouseLinc) to program and control your
devices. However, it will be helpful to have a list of your devices, should you choose to use automation
software later. Creating a list prior to installation will prevent you from needing to re-open all th e junction
boxes and fixtures to determine the INSTEON I.D.s.
IMPORTANT!
If you are not knowledgeable about and comfortable with electrical circuitry, you should have a qualified electrician
install 240V Load Controller for you. If you have any questions, please consult an electrician or call:
INSTEON Support Line
800-762-7845
Page 5 of 14