Device Overview
Buttons
Installation
Leave Your Lamp On
INSTEON Links
Understanding Linking 6
Links are One-Way
Links Remember a Device’s State
Controllers
Responders
Controller-Only 7
Responder-Only
Grouping Devices
Use Cross Linking
INSTEON Hub
Linking to the INSTEON Hub 9
Manual Linking
Linking with a Single-Button Controller 11
Linking with a Multi-Button Controller 12
Multi-Linking or Making a Scene 13
Unlinking from a Single-Button Controller 14
Unlinking from a Multi-Button Controller 15
Multi-Unlinking or Removing a Scene 16
Local Programming
About Local Programming 18
Local Programming Flow Chart 19
Software-Only Features
Beep on Button Press 21
Disable Local Programming
Blink on Trac
Error Blink
X10 Support
Setting the X10 Address 23
Removing the X10 Address 24
Appendix
Specications 27
Troubleshooting 30
Certications and Warnings 32
Product Warranty 33
Page 3
Getting Started
Getting Started
Everything you need to quickly get up and running.
Everything you need to quickly get up and running.
3
Page 4
O
INSTEON Dimmer Module
ButtonsDevice Overview
Status LEDOn
Tap to turn on
Double-tap to turn on instantly
Press and hold to brighten
Tap to turn o
Double-tap to turn o instantly
On
O
Set Button
®
Press and hold to dim
See sections on Basic Linking and
Local Programming for set button
functions
Plug your lamp into the bottom of the
Dimmer Module and plug the Dimmer Module
into an unswitched wall outlet.
®
Leave Your Lamp OnInstallation
If your lamp’s switch is OFF, the Dimmer Module
will be unable to remotely control your lamp.
ON
4
Page 5
INSTEON Links
INSTEON Links
INSTEON devices can stand alone and function as a local switch or
INSTEON devices can stand alone and function as a local switch or
dimmer, but their real power comes when they are connected together to
dimmer, but their real power comes when they are connected together to
form a control system. Most INSTEON devices can control one another
form a control system. Most INSTEON devices can control one another
and be the recipient of control. The process of associating multiple
and be the recipient of control. The process of associating multiple
INSTEON devices to one another is called Linking.
INSTEON devices to one another is called Linking.
5
Page 6
NEW
NEW
75%
NEW
NEW
Understanding Linking
Links Remember a Device’s StateLinks are One-Way
When linking INSTEON devices, the links that
are created are one-way.
ASwitchBDimmer Module
The current state of the controlled device is
stored in the link: on, o or dimmed.
®
Switch A will turn Switch B on and o but
Switch B cannot turn Switch A on or o.
INSTEON devices that can turn other devices
on or o are called controllers.
®
b
a
c
d
e
g
f
h
®
The switch will turn on the Dimmer Module
to 75% brightness.
RespondersControllers
INSTEON devices that receive the command of a
controller are called responders.
N
On
Neutral
Off
N
Set
Load L1
Line L
®
®
Sensors, Switches, Keypads and the
Hub are common controllers.
Switches, LED Bulbs, Plug-In Modules and
Micro Modules are common responders.
6
Page 7
NEW
X
NEW
X
Understanding Linking
NEW
NEW
Controller-Only
Some devices like sensors can only control
other devices.
®
Motion Sensor
The Motion Sensor will turn on the Switch
but the switch cannot control the Motion
Sensor.
Responder-Only
Some devices cannot control other devices;
these devices only receive INSTEON commands.
LED BulbDimmer SwitchDimmer Switch
Some devices can only link as
responders to devices and scenes.
Grouping DevicesUse Cross Linking
You may want to group together two
devices, for example, in a virtual-three way
conguration. For INSTEON, this is called
Cross Linking.
AABBLoad
To group Switch A and B so that they each
control one another and the connected
load, Cross Linking is necessary.
To Cross Link, simply turn on the devices and
perform the linking process twice, once in
each direction.
Link Switch A to Switch B and repeat to link
Switch B to Switch A.
7
Page 8
INSTEON Hub
INSTEON Hub
The INSTEON Hub allows you to congure your device, customize its
The INSTEON Hub allows you to congure your device, customize its
properties, create scenes and more, all from your smartphone or tablet.
properties, create scenes and more, all from your smartphone or tablet.
8
Page 9
Linking to the INSTEON Hub
From Rooms, navigate to All Devices.
1
Rooms
All Devices Check-InFavorites
BathroomBedroomHallway
Kitchen Living Room Outside
72º
Tap the Add button.
2
Back Door BathroomBedroom
Font Door Garage Door Garage Light
Motion Sensor Outside Lights
All Devices
Add
72º
Select Plug-In Module form the list of
3
devices.
Add Device
Plug-In ModuleWired In
LED BulbThermostat
When prompted, press and hold the
4
set button on your Dimmer Module
until the device double-beeps.
®
You can now control your Dimmer
Module from the INSTEON Hub.
9
Page 10
Manual Linking
Manual Linking
When not using a central controller like the INSTEON Hub, INSTEON
When not using a central controller like the INSTEON Hub, INSTEON
devices can be congured and linked manually on a device-to-device
devices can be congured and linked manually on a device-to-device
basis. It is strongly advised that you not perform manual linking when
basis. It is strongly advised that you not perform manual linking when
using a central controller. Instead, let your central controller handle the
using a central controller. Instead, let your central controller handle the
linking for you.
linking for you.
10
Page 11
Linking with a Single-Button Controller
Manual Linking Only
On your INSTEON controller, press
1
and hold the set button until the
device beeps.
Make sure the Dimmer Module is
2
On and then press and hold the
Dimmer Module’s set button until
the device double-beeps.
®
®
Your INSTEON controller will now
control your Dimmer Module.
11
Page 12
Linking with a Multi-Button Controller
Manual Linking Only
On your INSTEON controller, tap
1
the desired control button and
then press and hold the set button
until the device beeps.
B
Make sure the Dimmer Module is
2
On and then press and hold the
Dimmer Module’s set button until
the device double-beeps.
A
®
®
Your INSTEON controller will now
control your Dimmer Module.
12
Page 13
Multi-Linking or Making a Scene
Manual Linking Only
On your INSTEON controller, press
1
and hold the set button until the
device beeps, then tap the set
button.
A
B
Adjust your scene members to
2
their desired state: on, o, or
brightness level if dimming.
50%72%
Lamp 1
30%
Lamp 3
Lamp 2
ON
Appliance
One at a time, press and hold the
34
set button on each scene member
until it double-beeps.
®
Tap the set button on your
INSTEON controller to nish
building your scene.
Your INSTEON controller will
now control your scene.
13
Page 14
Unlinking from a Single-Button Controller
X
Manual Linking Only
On your INSTEON controller, press
1
and hold the set button until the
device beeps.
Press and hold the set button
2
again until the device beeps.
Press and hold the Dimmer
3
Module’s set button until the
device double-beeps.
®
®
Your INSTEON controller will no
longer control your Dimmer Module.
14
Page 15
Unlinking from a Multi-Button Controller
X
Manual Linking Only
On your INSTEON controller, tap
1
the desired control button and
then press and hold the set button
until the device beeps.
B
Press and hold the set button
2
again until the device beeps.
A
Press and hold the Dimmer
3
Module’s set button until the
device double-beeps.
®
®
Your INSTEON controller will no
longer control your Dimmer Module.
15
Page 16
Multi-Unlinking or Removing a Scene
X
Manual Linking Only
On your INSTEON controller, press
1
and hold the set button until the
device beeps. Press and hold the
set button again, then tap the set
button.
One at a time, press and hold the
2
set button on each scene member
until it double-beeps.
A
B
®
C
Tap the set button on your
3
INSTEON controller to exit MultiUnlinking mode.
®
®
®
Your INSTEON controller will no longer
control your INSTEON responders.
16
Page 17
Local Programming
Local Programming
Use the local programming to set local on-level, ramp rates and even
Use local programming to set local on-level, ramp rates and even perform
perform a factory reset.
a factory reset.
17
Page 18
About Local Programming
NEW
The Local Programming Flowchart is a visual
representation of the device’s settings. Many
device features can be congured using this
diagram. Some devices have more options
than others but the Local Programming
Flowchart presents even the most
complicated devices with a straightforward,
navigable path.
Using a Central Controller
If using the INSTEON Hub or any other
central controller, it is strongly advised that
you not use Local Programming. Your central
controller can manage the device properties
and links for you.
Navigation Local Programming
To move right, press and
hold the set button
To move down, tap the set
button
Status LED blinks green
Status LED double-blinks
green
Status LED blinks red
Status LED double-blinks
red
Local Programming Features
Linking ModeReadies the module for linking to another INSTEON device. As linking is directional, the rst device placed
into linking mode will become the controller in the controller/responder relationship. The second device will
become the responder. The device automatically exits linking mode after a link has been made with another
INSTEON device or four minutes have elapsed without linking.
Multi-Linking
Mode
Unlinking
Mode
Multi-
Unlinking
Mode
Brightness
RF BeaconPlaces the device in a mode that broadcasts a signal over INSTEON RF. Any devices beeping or displaying a
Factory ResetErases any user-customized programming from the device including all INSTEON device links, scenes, ramp
Readies the module for linking to multiple INSTEON devices. The module will remain in linking mode for 4
minutes or until the module’s set button is tapped. This mode is very usefully for manually creating scenes.
Allows the removal of links from the INSTEON device. The device will automatically exit unlinking mode after a
link has been removed from another INSTEON device or four minutes have elapsed without linking.
Allows the removal of multiple links from the INSTEON device. The device will stay in unlinking mode for 4
minutes or until the device’s set button is tapped.
LED
Allows adjusting the brightness level of the module’s status LED.
blinking LED are within range of the module’s RF signal.
rate, on-level, etc. A factory reset cannot be undone.
18
Page 19
®
Select
Select
Multi-Linking
Mode
Linking Mode
Tap
Press
Unlinking
Select
Multi-
Unlinking
Mode
Mode
Tap
ExitExit
PressPress
PressPress
Local Programming Flow Chart
Factory Reset
RF BeaconRF Beacon
Tap
PressPress
Select
LED
Brightness
PressPressPress
TapTap
CancelCancel
Toggle
Adjust
LED
Brightness
Press
TapTap
Reset
Uses the current
brightness
Resume Dim
Exit
Select
Press
SaveExitExit
TapTapTap
Ramp Rate
TapTap
Press
Save
Ramp Rate
Cycle through
four presets
Save
Tap
CancelSave
Uses the current
brightness
On Level
Tap
19
Page 20
Software-Only Features
Software-Only Features
Most INSTEON devices contain features that can only be enabled,
Most INSTEON devices contain features that can only be enabled,
disabled or modied using INSTEON control software such as HouseLinc
disabled or modied using INSTEON control software such as HouseLinc
and an INSTEON PowerLine Modem or the INSTEON Hub.
and an INSTEON PowerLine Modem or the INSTEON Hub.
20
Page 21
Software-Only Features
X
X
Beep on Button PressDisable Local Programming
The Dimmer Module will beep every time one
of its buttons are tapped. By default, this
feature is disabled.
Prevents changing any settings using the
set button or tap-and-hold programming. By
default, this feature is disabled.
®
Blink on TracError Blink
The Dimmer Module LED will blink if it detects
INSTEON communication. By default, this
feature is disabled.
®
The Dimmer Module LED will blink red once if
one or more responders do not acknowledge
a message and will blink green once if all
responders successfully acknowledge a
message. By default, this feature is enabled.
®®®
21
Page 22
X10 Support
X10 Support
Your INSTEON device features backwards compatibility with legacy X10
Your INSTEON device features backwards compatibility with legacy X10
devices and can respond to X10 powerline messages.
devices and can respond to X10 powerline messages.
22
Page 23
Setting the X10 Address
A1ONONON
Press and hold the set button
1
on your Dimmer Module until the
device beeps.
®
Using an X10 controller, send the
2
desired X10 address followed by
the On command three times.
®
Your Dimmer Module will now
respond to the set X10 address.
23
Page 24
Removing the X10 Address
X
A1ONONON
Press and hold the set button
1
on your Dimmer Module until the
device beeps.
®®
Press and hold the set button
2
again until the device beeps.
Using an X10 controller, send the
3
programmed X10 address followed
by the On command three times.
®
Your INSTEON controller will no
longer control your Dimmer Module.
24
Page 25
Appendix
Appendix
Everything else you might need to know about your INSTEON product.
Everything else you might need to know about your INSTEON product.
25
Page 26
INSTEON Glossary
ControllerThe INSTEON transmitter
ResponderThe INSTEON receiver
BlinkingLED turning on and o repeatedly
Dual-BandAn INSTEON device that can send and receive both INSTEON powerline signals and
INSTEON radio frequency signals
Ramp RateThe speed at which the load fades on or o
On-LevelThe preset brightness level a device will return to when turned on
INSTEONA dual-band, mesh networking technology developed by Smarthome/INSTEON. The world’s
most reliable, expandable and simple home automation and control technology.
LinkA one way association between a controller and responder
LinkingA method for associating INSTEON controller buttons with groups of INSTEON responders
such that the responders instantly return to a memorized state when the button is pushed.
Links can be made manually with the set button or using software.
UnlinkingThe process by which an INSTEON device can remove stored links. Just as with linking,
unlinking is a one-way process and should be performed in both directions for devices that
are both controllers and responders of each other, as in a 3-way switch scenario.
Multi-Linking
/ Unlinking
Factory ResetA process that erases all stored links and recongures the device to factory defaults.
LoadThe device that you are controlling (e.g. a light bulb, ceiling fan, etc.)
On/OA device that can control its connected load to turn on and o but cannot dim. Usually a
RetryA 2nd (or subsequent) attempt by a controller to send an INSTEON signal, usually after an
SceneMultiple devices respond to memorized states. For example, a dinner time scene turns
Set ButtonA button on an INSTEON device that is used for setting or changing its properties
SimulcastA method for increasing the reliability of message delivery in a network. When a node in
A special mode that allows more than one link to be either created or removed
simultaneously, without laborious set button presses. When in linking or unlinking mode, an
INSTEON device will continue to link to other devices until the set button is tapped or four
minutes have elapsed, whichever occurs rst.
relay-based device.
acknowledge is not received from the responder in the expected time-slot.
on the dining table light, dims the kitchen lights to 10%, backyard lights turn o and the
thermostat adjusts to 72º.
a network sends a message, every other node that hears the message retransmits it at
precisely the same time based on a global clock, provided that the message has not already
been retransmitted some maximum number of times. Message propagation is more robust
because each node adds its energy to the signal, much like voices in a choir. Simulcasting
is much simpler than message routing because there are no routing tables to maintain and
nodes can join the network without any installation procedure.
X10A legacy powerline networking technology. Many INSTEON devices are backwards
compatible with X10 devices by setting a house and unit code.
26
Page 27
General
Operation
Specications
Available ColorsWhite
Brand:INSTEON
FCC IDSBP2475D2A
Industry Canada5202A-2475D2A
Manufacturer Product No.:2475D2
Patent No.:Protected under US and Foreign Patents (see www.insteon.com/
patents)
UPC:813922010183
Warranty:2 years, limited
Audio AlertBeeper, can be enabled/disabled through software
Operation ModesINSTEON, X10
Load SensingNo
Local ControlYe s
Setup MemoryNon-volatile EEPROM
Status LEDRed/Green LED
INSTEON Features
INSTEON Device Category0x01 dimmable lighting control
Controlled OutletYes, ungrounded polarized. NEMA 1-15 type
Hardwired Remote ControlNo
Load TypesPlug-in incandescent lighting sources
Maximum Load300 Watts
Minimum Load5 Watts
Pass-through OutletNo
Power Consumption<0.75 Watts
Supply Voltage120 Volts AC ± 10%, 60 Hertz, single phase
Surge ResistanceSurges over 1,000 volts
X10 Features (Powerline Only)
X10 SupportYe s
29
Page 30
Troubleshooting
Dimmer Module LED does not turn on
It is possible your Dimmer Module is not receiving power. If the attached load can still be controlled, It is possible
that the status LED has been disabled.
Try this:
• Test Dimmer Module in a dierent power outlet. If the LED illuminates when using a dierent outlet, check
the original outlet for power. Some outlets are controlled by a switch elsewhere in the room. Avoid switched
outlets as they disable your INSTEON device when turned o.
• If the outlet works and the connected lamp can be toggled, use software or the Local Programming
Flowchart to change the behavior of the status LED. The status LED brightness can be dimmed to the
point that it appears o. The INSTEON Hub and other central controller software allow setting of this device
property.
Unable to add Dimmer module to a scene as a controller or a responder
If the device has power, something is likely interfering with the INSTEON signal. Large appliances, power strips
and some electronic devices may generate powerline noise.
Try this:
• Check to see if you have connected Dimmer Module to a power strip, surge suppressor, backup battery or
AC line lter. These devices often lter out the INSTEON powerline signal. Relocate the Dimmer Module to a
standard AC outlet.
• Large appliances like refrigerators or air conditioners may be generating powerline noise that is disrupting
the INSTEON signal. If the issue only appears to happen when one of these large appliances is running,
install a noise lter at that device. If you are uncertain of the device generating the noise, disconnect the
potentially oending devices from power and test your Dimmer Module again. If the issue is resolved, install
noise lters at each oending appliance.
• Some small electronics devices that include an AC/DC power supply can generate substantial electrical
noise, in some cases, enough to disrupt an entire house of INSTEON devices. Search your home for
speaker docks, small stereos, etc. and disconnect them from power to perform testing. If removing these
devices from your powerline resolves the INSTEON issue, install a noise lter at each oending small
electronic appliance.
• Your Dimmer Module may be too far from another INSTEON device to receive a signal. Try locating the
Dimmer Module closer to another INSTEON device and if the issue is resolved, install a Range Extender
or other Dual-Band INSTEON device between the intended location of your Dimmer Module and the next
nearest INSTEON device.
The Dimmer Module is slow to respond to commands from a controller
This issue most likely lies with the controller, not the Dimmer Module; the controller is most likely repeating
commands not acknowledged by an INSTEON device that has been removed from the network. The repeated
commands are slowing down the INSTEON network, resulting in a delayed response from the Dimmer Module.
Try this:
• Consider if you have removed any INSTEON devices from you network that were part of the slow-torespond scene. If so, the links to these devices need to be removed from the controller. Use software to
examine the database of the controller or if you know the modules that were removed, manually remove
their links using the standard unlinking procedure.
• If you are unable to identify the missing devices, perform a factory reset on the controller. This will remove
all links from the controller’s database but will also require that you recongure the device’s scenes and
properties.
30
Page 31
Troubleshooting
The connected lamp turned on by itself
There must be a device in your INSTEON network that is unexpectedly linked to the Dimmer Module. If you have
given your device an X10 address, powerline noise may be triggering the INSTEON device.
Try this:
• Use software to examine the Dimmer Module’s links. If you can identify the stray controller, remove the link.
• If you are unable to identify the unexpected controller, perform a factory reset on the Dimmer Module.
This will remove all links from the module’s database but will also require that you recongure the device’s
scenes and properties.
• If you have assigned your device an X10 address, try assigning a dierent X10 address or taking steps to
identify and isolate electronics that may be generating powerline noise.
Using a controller, Dimmer Module will turn o but not turn on
Most likely, the Dimmer Module was linked to the controller with the load set to O
Try this:
• Make sure the Dimmer Module’s connected load is on and then re-link the device to your INSTEON
controller. This link will overwrite the previous “o” link.
Dimmer Module does not respond to button taps or controller links
A power surge or excessive powerline noise may have caused the module to unexpectedly stop responding.
Try this:
• Unplug Dimmer Module for 10 seconds and then reconnect the device to power. Test the local buttons to
see if the load will turn on or o.
• While unusual, Dimmer Module may require a factory reset to restore normal operation. Follow the
procedure outlined in Local Programming to reset the device to factory settings. You will be required to
recongure the device’s scenes and properties after the reset.
When using the connected lamp’s switch, the load does not turn on
Your load may not be receiving power if the Dimmer Module is o.
Try this:
• Use the buttons on the side of the Dimmer Module to turn on the connected device. Remember, if the
connected lamp is turned o using its own switch, Dimmer Module is unable to control the device.
• Check the bulb in your lamp. It is possible that your light bulb needs to be replaced.
31
Page 32
Certications and Warnings
Read and understand these instructions before installing and retain them for future reference.
This product is not designed or approved for use on powerlines other than 120VAC, 50Hz or 60Hz, single
phase. Attempting to use this product on unapproved powerlines may have hazardous consequences.
• Use only indoors or in outdoor rated box
• This product may feel warm during operation. The amount of heat generated is within approved limits and
poses no hazards. To minimize heat buildup, ensure the area surrounding this product is as clear of clutter
as possible.
• Each INSTEON product is assigned a unique INSTEON I.D., which is printed on the product’s label.
• To reduce the risk of overheating and possible damage to other equipment, do not use this product to
control loads in excess of the specied maximum(s) or, install in locations with electricity specications
which are outside of the product’s specications. If this device supports dimming, please note that dimming
an inductive load, such as a fan or transformer, could cause damage to the dimmer, the load bearing
device, or both. If the manufacturer of the load device does not recommend dimming, use a non-dimming
INSTEON device. USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD.
This device complies with FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the device.
Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts
de licence. L’exploitation est autorise aux deux conditions suivantes: (1) l’appareil ne doit pas produire de
brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est
susceptible d’en compromettre le fonctionnement.
CAUTION - To reduce the risk of overheating and possible damage to other equipment do not install to control
a receptacle, a motor-operated appliance, a uorescent lighting xture, or a transformer-supplied appliance.
Gradateurs commandant une lampe a lament de tungstene – an de reduire le risqué de surchaue et la
possibilite d’endommagement a d’autres materiels, ne pas installer pour commader une prise, un appareil a
moteur, une lampe uorescente ou un appareil alimente par un transformateur.
32
Page 33
Product Warranty
Limited Warranty
Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date
of purchase, this product will be free from defects in material and workmanship and will perform in substantial
conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to defects or
errors caused by misuse or neglect. If the product is found to be defective in material or workmanship, or if the
product does not perform as warranted above during the warranty period, Seller will either repair it, replace it,
or refund the purchase price, at its option, upon receipt of the product at the address below, postage prepaid,
with proof of the date of purchase and an explanation of the defect or error. The repair, replacement, or refund
that is provided for above shall be the full extent of Seller’s liability with respect to this product. For repair or
replacement during the warranty period, call 866-243-8022 with the Model # and Revision # of the device to
receive an RMA# and send the product, along with all other required materials to:
INSTEON
ATTN: Receiving
16542 Millikan Ave.
Irvine, CA 92606-5027
Limitations
The above warranty is in lieu of and Seller disclaims all other warranties, whether oral or written, express or
implied, including any warranty or merchantability or tness for a particular purpose. Any implied warranty,
including any warranty of merchantability or tness for a particular purpose, which may not be disclaimed
or supplanted as provided above shall be limited to the two-year of the express warranty above. No other
representation or claim of any nature by any person shall be binding upon Seller or modify the terms of the
above warranty and disclaimer.
Home automation devices have the risk of failure to operate, incorrect operation, or electrical or mechanical
tampering. For optimal use, manually verify the device state. Any home automation device should be viewed as
a convenience, but not as a sole method for controlling your home.
In no event shall Seller be liable for special, incidental, consequential, or other damages resulting from
possession or use of this device, including without limitation damage to property and, to the extent permitted by
law, personal injury, even if Seller knew or should have known of the possibility of such damages. Some states
do not allow limitations on how long an implied warranty lasts and/or the exclusion or limitation of damages, in
which case the above limitations and/or exclusions may not apply to you. You may also have other legal rights
that may vary from state to state.