Quick Start Guide
INSTEON® Micro Open/Close (Shutter)
Model: 2444-222/2444-422/2444-522
What’s Needed
• Slotted #1 screwdriver • Voltage meter
• Philips screwdriver • Wire cutter/stripper
Installing Micro Module
Installation should only be performed by a qualified electrician or a homeowner
who is familiar and comfortable with electrical circuitry. If you have questions,
consult an electrician or call the INSTEON Support Line at 866-243-8022
1) Write down the INSTEON ID found on the back of the unit (XX.XX.XX)
2) Turn off breaker/fuse and verify that the power is off
3) Disconnect wires from existing switch, fixture or outlet and prep all wires to
be connected to Micro module, with 3/16” (5mm) of bare wire on the ends
4) Connect wires per diagram which corresponds to your installation
Note: sense lines carry very low current (~0.35mA 240V, ~0.17mA for 120V)
(down - purple)
(up - yellow)
5) After ensuring wires are firmly connected and that there is no exposed wire, turn on breaker/fuse
After a few seconds, Micro module LED will turn green
6) Test by tapping Micro module up/down buttons
Motor will respond accordingly
Micro Module LED will turn green when motor is moving up/o pen and stay green until the down button is pressed
Micro Module LED will turn red when motor is moving down/closed and stay red until the up button is pressed
7) If installing a single momentary or dual momentary switch
a) Press and hold set button until it beeps
LED will start blinking green
b) Press and hold set button until it beeps a second time
LED will start blinking red
2444-222, 2444-422, 2444-522 Rev. 2/24/2014 9:18 AM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see www.insteon.com/patents)
© Copyright 2013 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 866-243-8022
c) Press and hold set button until it beeps a third time
LED will start blinking green
d) Perform the step that applies
• For single momentary: slowly tap set button four times
LED will continue blinking green
• For dual momentary: slowly tap set button five times
LED will start double-blinking green
• To switch back to latching: slowly tap set button six times
LED will start blinking green
e) Once the mode is selected, press and hold set button until it doubl e-beeps
LED will stop blinking and t urn green if motor is up/open or red if motor is down/closed
Calibrate Micro Module
Once wired in, you need to calibrate Micro module for the time it takes for your application—shutters, blinds, projector screens, etc.—to fully
raise/lower or open/close. Do not walk away during the calibration process as your set button taps will determine the timing. These settings can
also be configured remotely via software (sold separately).
1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps again
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking green
4) Press and hold set button until it beeps a fourth time
LED will start blinking red
5) Slowly tap set button twice
LED will continue blinking red
6) Press and hold set button until it beeps
Motor will begin travelling one direction
7) As soon as motor is fully lowered (or raised), tap set button
Motor will begin travelling the opposite direction
8) As soon as motor is fully raised (or lowered), tap set button
Micro module will double-beep
Reverse Motor Direction
For some applications, such as a projector screen, you want the connected motor to lower or close your connected screen or blinds when you
press the up button or send an on command. Or you may have accidentally wired Micro module into the motor wrong. However, you don’t have to
rewire Micro module to fix it. Follow these steps to reverse the motor direction in response to commands (i.e., an on command will close/lower
while an off command will open/raise).
1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps again
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking green
4) Press and hold set button until it beeps a fourth time
LED will start blinking red
5) Slowly tap set button three times
LED will continue blinking red
6) Press and hold set button until it double-beeps
7) Test by tapping connected switch up and down
Motor will now operate in the reverse direction
Make Micro Module a Responder
1) Press and hold controller set button until it beeps
Controller LED will start blinking
2) You will have four minutes to complete the next steps before linking mode times out
Adjust motor connected to Micro module to desired level
3) Press and hold Micro module set button until it double-beeps
Controller will double-beep and its LED will stop blinking
4) Test link by tapping controller button on and off or pressing and holding to brighten/dim
The motor connected to Micro module will respond appro pria tely
2444-222, 2444-422, 2444-522 Rev. 2/24/2014 9:18 AM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see www.insteon.com/patents)
© Copyright 2013 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 866-243-8022
(Responder)