INSTEON 2442-422, 2442-522, 2442-222 User Manual

Page 1
Micro Dimmer
North America
EU/AUS/NZ
Owner’s Manual
2442-222 (US) 2442-422 (EU) 2442-522 (AUS/NZ)
Page 1 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 2
About Micro Dimmer ................................................................................................................................... 4
Features and Benefits ............................................................................................................................... 4
Before Installation ....................................................................................................................................... 4
Identifying the Electrical Wires in Your Home (North America only) ......................................................... 5
Identifying the Electrical Wires in Your Home (Europe/Australia/New Zealand) ....................................... 5
Identify Switch Type .................................................................................................................................. 5
Installation ................................................................................................................................................... 6
Switch Operation Mode .............................................................................................................................. 7
Change to Single Momentary Mode .......................................................................................................... 7
Change to Dual Momentary Mode ............................................................................................................ 7
Change to Latching Mode (default) ........................................................................................................... 8
3-Way Toggle Mode (Latching Switches Only, Default) .......................................................................... 8
Local Control Operation ............................................................................................................................. 9
Latching Switch (Default) ........................................................................................................................... 9
Single Momentary Switch .......................................................................................................................... 9
Dual Momentary Switch ............................................................................................................................. 9
Adjust Local Settings ............................................................................................................................... 10
Local On-Level ........................................................................................................................................ 10
Local Ramp Rate ..................................................................................................................................... 10
Resume Dim ............................................................................................................................................ 11
Change LED Brightness (or turn it off) .................................................................................................... 11
Error Blink ................................................................................................................................................ 12
Blink on Traffic ......................................................................................................................................... 12
Beep on Button Press .............................................................................................................................. 12
Programming Lock .................................................................................................................................. 12
INSTEON Setup ......................................................................................................................................... 12
INSTEON Controllers, Responders and Links ........................................................................................ 12
Configure INSTEON Settings .................................................................................................................. 13
Make Micro Module a Responder (Set butt on)........................................................................................ 13
Make Micro Module a Responder (Switc h) ............................................................................................. 13
Make Micro Module a Controller (Set butt on).......................................................................................... 13
Make Micro Module a Controller (Swit ch) ............................................................................................... 14
Groups ..................................................................................................................................................... 14
Scenes ..................................................................................................................................................... 14
Make Micro Module a Controller of Multip le Res po nder s ....................................................................... 15
Remove Micro Module as a Controller .................................................................................................... 15
Remove Micro Module as a Responder .................................................................................................. 15
Remove Micro Module as a Controller of Multiple Responders .............................................................. 15
Factory Reset .......................................................................................................................................... 16
X10 Setup ................................................................................................................................................... 16
Add X10 Address ..................................................................................................................................... 16
Remove X10 Address .............................................................................................................................. 16
Specifications ............................................................................................................................................ 17
Troubleshooting ........................................................................................................................................ 20
Stuck/Disabled Buttons ........................................................................................................................... 22
Phase Bridge Detect Beacon/RF Range Test ......................................................................................... 22
Certification and Warranty ....................................................................................................................... 23
Certification .............................................................................................................................................. 23
FCC and Industry Canada Compliance Statement ................................................................................. 23
Declaration of Conformity ........................................................................................................................ 23
ETL/UL Warning (Safety Warning) .......................................................................................................... 23
Page 2 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 3
Limited Warranty ..................................................................................................................................... 23
Limitations................................................................................................................................................ 24
Page 3 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 4

About Micro Dimmer

In the Box
Tools Needed
Optional Accessories
Micro Dimmer
Slotted screwdriver
Mini Remote
Quick Start Guide
Phillips screwdriver
INSTEON Hub
Wire cutter/stripper
Voltage meter
excess of the specified maximum(s) or, install in locations with electricity specifications which are outside of the product’s
Sense #1
Sense #2
LED
Antenna (secured for
shipping purposes)
(yellow)
(purple)

Features and Benefits

- Integrated dimmer featuring 32 dim levels and 32 ramp rates
- Wires in behind existing wall switch or in fixtur e box (requires neutral wire)
- Compatible with latching, single momentary and dual momentary switches
- Sense wires allow local control from any standard wall switch
- Can contain up to 400 controller/responder links
- X10 compatible
- All settings preserved in non-volatile memory, even through power failures
- Beeper for easy setup assistance; can also function as a chime module
- Local programming lockout available via software
- 2-year warranty

Before Installation

CAUTIONS AND WARNINGS
Read and understand these instructions before installing and retain them for future reference. This product is intended for installation in accordance with the National Electric Code and local regulations i n the United States or
the Canadian Electrical Code and local regulations in Canada. Use indoors only. This product is not designed or approved for use on power lines other than 100-240VAC,50Hz or 60Hz, single phase. Attempting
to use this product on non-approved power lines may have hazardous consequences.
- Use only indoors or in outdoor rated box
- Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are installing this product into. Installing this product with the power on will expose you to dangerous voltages.
- Connect using only copper or copper-clad wire
- This product may feel warm during operation. The amount of heat generated is within approved limits and poses no hazards. To minimize heat buildup, ensure the area surrounding this product is as clear of clutter as possible.
- Each INSTEON product is assigned a unique INSTEON I.D., which is printed on the product’s label.
- To reduce the risk of overheating and possible damage to other equipment, do not use this product to control loads in
Page 4 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 5
specifications. If this device supports dimming, please note that dimming an inductive load, such as a fan or transformer,
could cause damage to the dimmer, the load bearing device, or both. If the manufacturer of the load device does not
electrical circuitry, you should have a qualified electrician install the product for you.
recommend dimming, use a non-dimming INSTEON on/off switch. USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD.

Identifying the Electrical Wires in Your Home (North America only)

- Line: usually black (may also be called hot, live or power), carries 120VAC electricity into the wall box
- Neutral: usually white or white wire bundle, commonly daisy-chained from box to box
- Load: usually black, from a separate cable jacket
- Ground: bare copper wire or metal fixture (if grounded)

Identifying the Electrical Wires in Your Home (Europe/Australia/New Zealand)

- As wire colors vary from country to country, make sure you always check your electrical wires with a voltage meter to correctly identify line, load, neutral and ground wires
- If you have any questions, consult an electrician or your electricity supplier to learn more about your country’s wiring colors and labels
IMPORTANT! If you have any difficulties or questions, consult an electrician. If you are not knowledgeable about, and comfortable with,

Identify Switch Type

Before you insta ll Micro module behind a switch, you must determine which switch operation mode applies to your switch—latching, single momentary or dual momentary—as each is wired differently:
Latching (default mode): Switch has no central position. It can be tapped on both the top and bottom and remains in that state once released.
Single momentary: Switch can only be tapped in one location. It returns to central position once released.
Dual momentary: Switch can be tapped on both the top and bottom. It returns to central position once released.
Note: If you are installing Micro module in a fixture box, switch operation mode does not apply.
Page 5 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 6

Installation

1) Write down the INSTEON ID found on the back of the unit (XX.XX.XX)
2) Turn off breaker/fuse and verify that the power is off
3) Disconnect wires fr om existing switch, fixture or outl et and prep all wires to be connecte d to Micro
module, with 3/16” (5mm) of bare wire on the ends
4) Connect wires per diagram which corresponds to your installation
Note: sense lines carry very low current (~0.35mA 240V, ~0.17mA for 120V)
5) After ensuring wires are firmly connected and that there is no exposed wire, turn on breaker/fuse
After a few seconds, load will turn on (if wired into switch or fixture) and Micro module LED will turn green
6) Test by tapping Micro module on/off buttons
Load will turn on and off
Micro Module LED will turn green when load is on and red when load is off
7) If installing a single momentary or dual momentary switch a) Press and hold set button until it beeps
Page 6 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 7
LED will start blinking green
b) Press and hold set button until it beeps a second time
LED will start blinking red
c) Press and hold set button until it beeps a third time
LED will start blinking green
d) Perform the step that applies
For single momentary: slowly tap set button four times
LED will continue blinking green
For dual momentary: slowly tap set button five times
LED will start double-blinking green
To switch back to latching: slowly tap set button six times
LED will start blinking green
e) Once the mode is selected, press and hold set button until it double-beeps
LED will stop blinking and turn green if load is on or red if load is off

Switch Operation Mode

By default, Micro module is programmed for a latching switch. Program the switch operation for single momentary mode, dual momentary mode or back to latching mode according to your switch type. These settings can also be configured remotely via software (sold separately).
To determine Micro module’s current switch operation mode, simply tap set button:
If it beeps, Micro module is configured for a single momentary switch
If it double-beeps, Micro module is configured for a dual momentary switch
If it triple-beeps, Micro module is configured for a latching switch (default)

Change to Single Momentary Mode

1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking green
4) Slowly tap set button four times
LED will continue bl inki ng g r een
5) Press and hold set button until it double-beeps
LED will stop blinking
6) Test mode change by tapping switch on and off
Load will respond appropriately

Change to Dual Momentary Mode

1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking green
4) Slowly tap set button five times
LED will start dou bl e-blinking green
5) Press and hold set button until it double-beeps
LED will stop blinking
6) Test mode change by tapping switch top and bottom
Load will respond appropriately
Page 7 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 8

Change to Latching Mode (default)

1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking green
4) Slowly tap set button six times
LED will continue bl inki ng g r een
5) Press and hold set button until it double-beeps
LED will stop blinking
6) Test mode change by tapping switch on and off
Load will respond appropriately

3-Way Toggle Mode (Latching Switches O nly, Default)

Because Micro module comes programmed for latching switches, 3-way toggle mode is enabled by default. Normally, a latching switch reads the switch’s up position as on and down position as off. For example, if you turn Micro module on from the latching switch and off from another controller, the switch is still in the up (on) position; turning Micro module back on from the switch would require you to tap the switch down, then up again. The 3-way toggle mode overrides this sense feature, so in that same scenario—turning Micro module on at the switch and off from another controller, so switch is in up (on) position—you could then turn Micro module on at the switch by tapping it down.
If you are installing Micro module behind a single or dual momentary switch, 3-way toggle mode is ignored. If desired, you can disable (or re-enable) 3-way toggle mode by following thes e instr uct ions :
1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking green
4) Press and hold set button until it beeps a fourth time
LED will start blinking red
5) Slowly tap s et button 4 times
Micro module will beep LED will continue blinking red
6) Press and hold set button until it double-beeps
LED will stop blinking 3-way toggle mode is now disabled (or re-enabled)
Page 8 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 9
Connected load/responders
Latching switch
Tap
LED
Connected load/responders

Single momentary switch

Tap
Press and hold
Double-tap
LED
Connected load/responders

Dual momentary switch

Tap
Press and hold
Double-tap
LED

Local Control Operati on

Micro module’s switch operation mode affects how it responds to commands from the switch. This is why it’s important to program Micro module for the specific type of switch you are using. Micro module’s on/off buttons function exactly like the top and bottom of your wall switch.

Latching Switch (Default)

Note that this table refers to the latching switch operation if 3-way toggle mode is disabled (it is enabled by default).
Top
Bottom
On
(ramped)
Off
(ramped)
Green
Red
Single Momentary Switch
Switch
Dual Momentary Switch
Top
Bottom
On/Off
(ramped)
On
(ramped)
Off
(ramped)
Brighten/Dim
until release or full-on/off
(dimmable responders only)
Brighten
until release or 100%
(dimmable responders only)
Dim
until release or off
(dimmable responders only)
On/Off
(instant)
On
(instant)
Off
(instant)
Green/
Red
Green
Red
Page 9 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 10

Adjust Local Settings

Local On-Level

The local on-level is the brightness at which the connected load will come on when turned on at the switch wired into Micro module. The default on-level is 100% brig htn ess , but it can be set to any one of 32 fixed brightness levels (3% to 100%) or “resume dim” (brightness prior to last being turned off).
1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking green
4) Press and hold set button until it beeps a fourth time
LED will start blinking red
5) Tap set button
LED will start double-blinking red
6) Use Micro module on/off buttons to adjust loa d to des ir ed brightness
7) Press and hold set button until it double-beeps
LED will stop blinking and turn on green
8) Test by turning off and then back on via the paddle
Light will turn on at new local on-level

Local Ramp Rate

The local ramp rate is the time it takes for the connected light to reach 100% brightness from full-off. The default local ramp rate is 0.5 seconds, but it can be adjusted from instant-on to 5 seconds (using set button) or up to 8 minutes (with software).
Note: If your local on-level is set to a brightness level that is less than 100%, the ramp rate will be faster than programmed. For example, if your light has a 50% local on-level and a ramp rate of 2 seconds, it will take 1 second for it to ramp from full-off to the local on-level.
1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking green
4) Press and hold set button until it beeps a fourth time
LED will start blinking red
5) Slowly tap s et button 2 times
LED will continue blinking red
6) Press and hold set button to see the next selected ramp rate
Load will ramp from off to on at the next available ramp rate LED will continue blinking red
7) If this is the desired ramp rate, tap set button to accept
Micro module will doubl e beep and LE D will stop blinking
8) To see the next ramp rate, press and hold s et button again
Load will ramp from off to on at the next available ramp rate
Page 10 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 11
Ramp Rate Presets
“Instant”
0.5 seconds
(factory default)
2 seconds 5 seconds
9) Test by turning off and then back on via the local switch
Light will ramp off and back on at the new local ramp rate

Resume Dim

When resume dim is enabled, each time you turn on Micro module it will go t o the previously used dim level. By default, Micro module will come on at 100% brightness, but to change the desired level, simply follow the instructions below. The next time you turn Micro module off and on again, it will return to the last used dim level.
1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking green
4) Press and hold set button until it beeps a fourth time
LED will start blinking red
5) Slowly tap s et button three times
LED will start double-blinking red
6) Press and hold set button until it double-beeps
LED will stop blinking
7) Test by turning off and then back on via the local switch
Light will ramp off and back on to resume dim level.

Change LED Brightness (or turn it off)

Default = 50% brightness level
1) Press and hold set button until it beeps
LED will start blinking gree n
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinking gree n
4) Tap set button once
LED will start double-blinking green
5) Press and hold set button until it beeps
6) Press and hold Micro module on/off buttons to brighten or dim LED to desired brightness
7) Tap set button
Micro Module will double-beep and return to ready mode
Page 11 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
LED will turn green (at brightness of connected load)
Page 12
Controller
Responder
Link

Error Blink

Default = enabled This setting is only adjustable via software or a central controller. Micro module LED will blink red once for
a few seconds if one or more responders do not acknowledge a message and will blink green once if all responders are successful.

Blink on Traffic

Default = disabled This setting is only adjustable via software or a central controller. Micro module LED will blink red if it
detects noise that could disrupt communication.

Beep on Button Press

Default = disabled This setting is only adjustable via software or a central controller. Micro module will beep every time its
connected switch is tapped or a button is pressed.

Programming Lock

Default = disabled This setting is only adjustable via software or a central controller. When enabled, Programming Lock will
disable the set button so that a user can not adjust settings or modify links. This is typically used in commercial or installer applications.

INSTEON Setup

Some products have subtle differences in their setup procedures. Please refer to the other devices’ owner’s manuals for details.

INSTEON Controller s, R es pon der s and Li nk s

The INSTEON “transmitter” is called a controller
The INSTEON “receiver” is called a responder
The association between the controller and responder is called a link
Note that a link is one way. If you wish to have control “the other way,” simply add a link “the other way.”
Page 12 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 13

Configure INSTEON Settings

Most Micro module links and settings can be configured locally—during installation with the module’s set button or after installation using the switch connected to the module.
All Micro module settings can be managed remotely via software (sold separately).

Make Micro Module a Responder (Set button)

Note: you must perform these steps before reinstalling the wall switch or fixture.
1) Press and hold controller set button until it beeps
Controller LED will start blinking You will have four minutes to complete the next steps before linking mode times out
2) Adjust load connected to Micro module to desired brightness level (even off)
3) Press and hold Micro module set button until it double-beeps
Controller will double-beep and its LED will stop blinking
4) Test link by tapping controller button on and off or pressing and holding to brighten/dim
Load connected to Micro module will respond appropriately

Make Micro Module a Responder (Switch)

1) Press and hold controller set button until it beeps
Controller LED will start blinking You will have four minutes to complete the next steps before linking mode times out
2) Adjust load connected to Micro module to desired brightness level (on or off)
3) Quickly tap switch connected to Micro module exactly five times in less than four seconds. (If using a latching or dual momentary switch, alternate switch directions: up-down-up-down-up or down-up­down-up-down.) After tapping switch, wait two seconds.
Micro module will double-beep Controller will double-beep and its LED will stop blinking
4) Test link by tapping controller button on and off
Load connected to Micro module will turn on and off

Make Micro Module a Controller (Set but ton)

Note: you must perform these steps before reinstalling the wall switch or fixture.
1) Press and hold Micro module set button until it beeps
Micro module LED will start blinking green You will have four minutes to complete the next steps before linking mode times out
2) Adjust responder to desired state
3) Press and hold responder set button until it double-beeps
Micro module will double-beep and its LED will stop blinking
4) Test link by tapping or pressing and holding Micro module on/off buttons to turn on/off or brighten/dim
Responder will respond appropriately
1
If responder is a multi-scene device such as a KeypadLinc, tap scene button you wish to control until the LED is in the desired scene state (on or off).
2
If either controller or responder LED continues blinking, the addition failed. Tap device’s set button until LED stops blinking and try linking again.
Page 13 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
1
2
Page 14

Make Micro Module a Controller (Switch)

1) Quickly tap switch connected to Micro module exactly five times in less than four seconds. (If using a latching or dual momentary switch, alternate switch directions: up-down-up-down-up or down-up­down-up-down.) After tapping switch, wait two seconds.
Micro module will beep to indicate it has entered linking mode You will have four minutes to complete the next steps before linking mode times out
2) Adjust responder to desired state
1
3) Press and hold responder set button until it double-beeps
Micro module wi ll doubl e-beep and its LED will stop blinking
4) Test link by tapping switch connected to Micro module to turn on/off or brighten/dim
Responder will respond appropriately

Groups

Devices in a group share all the same settings (e.g., on-level, ramp rate). This keeps all group members synchronized. Every device in a group is both a controller of, and responder to, all the other devices. The most common example of a group is a 3-way lighting c ir c uit (2 switches). For simp licity, we will assu me that the desired group level is on.
The following steps will create a virtual 3-way circuit including device “A” and device “B”:
1) Turn A and B on
2) Press and hold A set button until it beeps
A status LED will start blinking green
3) Press and hold B set button until it double-beeps
A will double-beep and its LED will stop blinking
4) Press and hold B set button until it beeps
B LED will start blinking green
5) Press and hold A set button until it double-beeps
B will double-beep and its LED will stop blinking
6) Test by turning load on and off from A and then B
The load(s) and both A and B LEDs will remain in synch

Scenes

Devices in a scene can each have different settings. This provides for advanced scene creation. Software is recommended for scene management.
Example of a scene with 1 controller and Micro module as a member:
1) Press and hold controller button until it beeps
Controller LED will start blinking green
2) Tap controller set button
Controller LED will start double-blinking green
3) Adjust load connected to Micro module to desired brightness level
4) Press and hold Micro module set butt on until it double-beeps
5) For each additional scene member:
a. Adjust member to desired scene state b. Press and hold set button until it double-beeps
6) Tap controller set button
Controller will beep and LED will stop blinking
7) Test by tapping controller button on and off
Micro module and other scene responders will all respond appro priat ely
1
If responder is a multi-scene device such as a KeypadLinc, tap scene button you wish to control until the LED is in the desired scene state (on or off)
Page 14 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 15

Make Micro Module a Controller of Multiple Responders

1) Press and hold Micro module set button until it beeps
LED will start blinking green
2) Tap Micro module set butt o n
LED will start double-blinking green
3) For each responder you are adding:
a. Adjust responder to desired scene brightness/state b. Press and hold set button until it double-beeps
4) Tap Micro module set butt o n
Micro module will beep and LED will stop blinking
5) Test by tapping switch wired into Micro module on and off
All the responders will turn on and off

Remove Micro Module as a Controller

If you no longer want Micro module to control another device (or are removing Micro module from your network) it is important that you follow the instructions below for each responder.
1) Press and hold Micro module set button until it beeps
LED will start blinking gree n
2) Press and hold Micro module set button until it beeps a second time
LED will start blinking red
3) Press and hold responder set button until it double-beeps
Micro module will double-beep and LED will stop blinking
4) Test by tapping Micro module on and off
Former responder will not respond

Remove Micro Module as a Responder

If you no longer want a controller button to control Micro module, follow these directions.
Note: If you ever wish to uninstall Micro module, it is important that you remove all Micro module responder links. Otherwise, controllers will repetitively retry commands, creating network delays.
1) Press and hold controller button until it beeps
LED will start blinking green
2) Press and hold controller button until it beeps a second time
LED will start blinking red
3) Press and hold Micro module set butt on until it double-beeps
Controller LED will stop blinking
4) Test by tapping controller button on and off
Micro module will no longer respond

Remove Micro Module as a Controller of Multiple Responders

1) Press and hold Micro module set button until it beeps
LED will start blinking green
2) Press and hold Micro module set button until it beeps a second time
LED will start blinking red
3) Tap Micro module set butt o n
LED will start double-blinking red
4) For each responder you are removing:
a. Press and hold set button until it double-beeps
5) Tap Micro module set butt o n
Page 15 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 16
Micro module will beep and LED will stop blinking
6) Test by tapping the switch wired into Micro module on and of f
None of the former responders will respond

Factory Reset

All settings and scenes will be erased and return to factory default settings.
1) Press and hold Micro module set butt on until it beeps
LED will start blinking green
2) Press and hold Micro module set button until it beeps a second time
LED will start blinking red
3) Press and hold Micro module set butt on until it beeps a third time
LED will start blinki ng gr ee n
4) Slowly tap Micro module set button 3 times
LED will start doubl e-blinking green
5) Press and hold Micro module set button. Do not let go.
Micro module will begin to emit a long beep
6) After beep stops, release Micro module set button
After a few seconds, the LED will flash white Micro module will double-beep and the load will turn on

X10 Setup

Micro module ships with no X10 address assigned.

Add X10 Address

1) Press and hold set button until it beeps
LED will start blinking green
2) Send the X10 address 3 times (with or without commands)
Example: A1-AON-A1-AON-A1-AON or A1-A1-A1-AON Micro module will double-beep and LED will stop blinking
3) Test by sending X10 on and off commands
Load will turn on and off

Remove X10 Address

1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Send the X10 address 3 times (with or without commands)
Example: A1-AOFF-A1-AOFF-A1-AOFF or A1-A1-A1-AOFF Micro module will double-beep and LED will stop blinking
4) Test by sending X10 on and off commands
Micro module will not respond
Page 16 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 17

Specifications

General
Product name
Brand/manufacturer
Warranty
2 years, limited
INSTEON
INSTEON
Maximum links/scenes
Load brightness levels
LED brightness
Local on-level
Local control
Yes
Software Configurable
Manufacturer product number
UPC
Status LED
Beep on button press
Micro Dimmer INSTEON US 2442-222 EU 2442-422 AUS/NZ 2442-522 US 813922012705 EU 813922012712 AUS/NZ 813922012729
Controller and responder 400 32 locally (256 with software) Green when load is on, red when load is off Blinks red once when resp onder does not ac knowledge/blinks
green once if all responders acknowledge (can be disabled via software)
Blinks red or green during setup Blinks to indicate traffic (must be enabled via software) Beeps when button is pressed or connected switch is tapped
(must be enabled via software)
Local ramp-rate
Commands supported as controller
Commands Supported as responder
Adjustable, from off to bright Adjustable, 32 fixed brightness levels or resume dim Adjustable from 0.1 seconds to 5 seconds locally
(0.1 seconds to 8 minutes via software)
On Off Fast-on Fast-off Begin brighten Begin dim End brighten End dim On Off Fast-on Fast-off Begin brighten Begin dim End brighten End dim Incremental brighten Incremental dim Beep Yes
Page 17 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 18
RF Range
Phase detect beacon
INSTEON Device Category
X10
Mechanical
Behind switch or above light fixture in a single-gang electrical box
Sense 1 (yellow wire), 0.205m m2 / 24 AWG
Sense 2 (purple wire), 0.205mm2 / 24 AWG
Max Cable Size
Min Cable Size
Screw Clamp Connections
Line
Load
Neutral 1
Neutral 2
Case Color
White
Set button
Yes
Plastic
UV stabilized ABS+PC
Beeper
Yes
LED
1, RGB
Dimensions
46.6mm H x 46.6mm W x 17.5mm D (1.8” H x 1.8” W x 0.7” D)
Weight
71.5g (2.5 oz)
Operating Environm ent
Indoors
Operating Humidity Range
0-90% relative humidity
Up to 50 meters (150 feet) open air*
*Range may vary due to local interference/building construction
Yes 0x01 Dimmable Lighting Control (All Frequencies) 2442-222 (915 MHz) 0x35
INSTEON Device Subcategory
2442-422 (869 MHz) 0x38 2442-522 (921 MHz) 0x39
X10 address 1 optional (comes unassigned) X10 transmitter Yes X10 receiver Yes X10 status response Supported X10 resume dim Supported (by setting local on-level to zero) X10 minimum transmit level 3.2 Vpp into 5 Ohms X10 minimum receive level 20mV into 5 Ohms X10 messages repeated No
Mounting Wires
4mm2 (2.72mm diameter) / 12 AWG
Operating Temperature Range
Page 18 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
1.5mm2 / 15 AWG
32o to 104 o F (0 o to 40 o C)
Page 19
Storage temperature range
Electrical
Voltage
100VAC to 240VAC
Frequency
50/60Hz auto-detected at power-up
200 Watts (@ 240VAC) Minimum load
5 Watts
Load type(s)
Incandescent
Hardwired remote control
Yes, either latching or momentary switches supported
Retains all settings without power
Yes, saved in non-volatil e EE P RO M
Standby power consumption
< 1 watt
Safety approved
ETL, CE, C-Tick
FCC 15.107, 15.109, 15.249
FCC ID
SBPMM01
-4 o to 158 o F (-20 o to 70 o C)
Maximum load
200 Watts (@ 120VAC)
RSS 210 EN 300 220-2, 301 489-3
Certifications
AS/NZS 4268, CISPR 22 UL 1472 IEC 60669-2-1
All product specifications are subject to change.
Page 19 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 20
Problem
Possible Cause
Solution
Make sure the circuit breaker is turned on
Check junction box wires to ensure all exposed
Check the light fixture to ensure all exposed
utral
Look in the rear of the junction box for a group are commonly neutral wires.
Plug other modules into a signal filter or move the modules or controller to another outlet
INSTEON devices act as network repeaters. and retest.
Install a power line signal blocker in your home
module in X10 mode.
Micro module may have an membership
Use software to remove membership or module
The controlled light does off right away
reception of
Install an inline signal filter between the load and Micro module
I can’t turn Micro module brighten and dim it)
When I try to turn on my
Micro module may be set up
Remove the X10 address from Micro module

Troubleshooting

The LEDs on Micro module are not turning on at all
The switch I’m replacing only has two wires
Micro module is not receiving signals from INSTEON or X10 controllers
Micro module is not getting power
Micro module needs a ne wire in order to operate
The controller is plugged into a power strip
Other modules are attenuating the signal or causing noise on the line
Micro module and the controller are on opposite powerline phases
connections are tight and no bare wires are
connections are tight and no bare wires are
of wires tied together with a wire nut. Those
Pull a neutral from nearby junction box
Powerline signals can’t travel through some power filters. Plug controller into wall outlet.
Add new or move existing INSTEON devices
Make sure there are at least 2 dual-band INSTEON products are properly installed to bridge the phases
The light turned on by itself
not appear to turn on or
Micro module responds to on commands but not off commands
on (but I can turn it off,
Another controller, a timer, or stray X10 signals triggered Micro module
undesired responder
Responder’s scene ramp rate might be quite slow
Load connected to Micro module is producing electrical noise that is interfering with the Micro module powerline signal
The on-level may be set to fully-off or very dim
to keep X10 signals from neighboring homes from interfering. Consider not using Micro
perform a factory reset and re-setup Micro
Set a faster ramp rate and relink responder
Install additional INSTEON devices to boost the INSTEON signal
Set a brighter on-level. See Local On-Level
.
Page 20 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 21
light with another
controller, the light will
with an INSTEON on-level at
brightness
When I press a button on
controlling to respond
that is not
Connect power to the responder
If the INSTEON device is still available, remove it from Micro module and then re-add it
Perform a factory reset
The bulb filaments are vibrating. Use rough-
rade bulbs to reduce the
noise
Run Micro module in the “full-on” mode or switch to a non-dimming Micro On/Off module
Power cycle Micro module
Perform a factory reset
It is normal for dimmers to get
Micro module will dissipate abou t 1 watt per
lower the temperature.
Micro module blinks green
Micro module supports an
communicating properly
Micro module supports an
network
, but nothing
The responder’s link was not
half-link)
turn on, then back off
a high brightness and an X10 address on-level at a low
Remove the X10 address from INSTEON controller
Micro module, it takes a long time for other INSTEON device s it is
The load is buzzing when on or dim.
Micro module is locked up
Micro module is getting warm to the touch
one time after it is activated
Micro module is trying to control a responder responding and m a y have been removed
The dimming component inside Micro module “chops” the power line sine wave to reduce the power
A surge or excessive noise on the power line occurred
warm (Micro module conforms to safety standards)
error blink feature. A green blink indicates that all responders are
service, or appliance g
100 watts of load. Using metal junction boxes, removing insulation around the outside of the box and controlling a smaller load wil l all help
You may disable error blink via software if desired
Micro module blinks red one time after it is activated
Micro module can turn off my responder happens when I send an on
Micro module still controls devices even after factory reset
error blink to let you know that a responder did not acknowledge the command and that there is a lot of unacknowledged communications on the
Responder’s scene level is off
removed prior to Micro module factory reset (called a
Confirm that the responder is powered and available. If you don’t want this device to be a responder you can unlink it if available or use software to remove the link. Once the issue is resolved, you may disable error blink via software if desired.
Add responder to scene again at desired scene on-level
Remove responder from Micro module
Page 21 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 22

Stuck/Disabled Buttons

If Micro module’s buttons are not responding, they may have been disabled due to a stuck button. If any button is pressed during power-up, or after power-up any Micro module button is pressed for about four minutes, Micro module engages stuck button mode and automatically disables all button actions. All buttons will remain disabled until next power cycle.
To re-enable buttons, ensure buttons are not being pressed, turn off breaker supplying power to Micro module and turn it back on. Micro module buttons should function again. Additionally, check Micro module’s installation location for any obstacles that could be pressing the buttons on Micro module’s face and causing stuck button mode.

Phase Bridge Detect Beacon/RF Range Test

Micro module automatically bridges the electrical phases in your home (via communications with other dual-band devices on the “other phase”). This is only important in 2-phase homes with powerline-only INSTEON products or buildings with both 2- and 3- phase circuits. The phase bridge detect beacon can also be used as an RF range test to see if your devices are within communication range. You will need at least one other INSTEON dual-band device installed.
1) Press and hold set button until it beeps
LED will start blinking gree n
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Press and hold set button until it beeps a third time
LED will start blinki ng gr ee n
4) Slowly tap set button 2 times
LED will continue bl ink ing green
5) Press and hold set button until it beeps
Micro module will start beeping once per second LED will turn solid green
6) Check the LED behavior of other dual-band devices
Phase Bridge Detect Beacon
If the other dual-band device is blinking green, it is on the other phase:
Device provides a phase bridge to Micro mod ul e
If the other dual-band device is blinking red, it is on the same phase:
Device does not provide a phase bridge to Micro module Relocate if necessary (and practical)
If the other dual-band device is not blinking:
Device is not within RF range of Micro module so it does not provide a phase bridge Relocate if necessary (and practical) or add an additional dual-band device
RF Range Test
If LED is blinking:
Device is within RF communication range
If LED is not blinking:
Device is not within RF communication range Relocate if necessary (and practical) or add an additional dual-band device
7) Tap set button
Micro module will stop beeping
Other device LEDs will stop blinking
If you have tried these solutions, reviewed the owner's manual, and still cannot resolve the issue you are having visit http://www.insteon.com/support
or call INSTEON Support Line at 866-243-8022.
Page 22 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM
Page 23

Certification and Warranty

Certification

This product has been thoro ughly tested b y ITS ETL SEMKO, a n ationally reco gnized independ ent third-party testi ng laborator y. The North America n ETL Listed mark signifies that t he device has bee n tested to and has m et the requireme nts of a widely reco gnized cons ensus of U.S. and C anadian devic e safety standar ds, that the manufac turing site has been audi ted, and that the manuf acturer has agreed to a p rogram of quarterly fa ctory follow-up inspections to verify continued conformance.

FCC and Industry Canada Compliance Statement

This device complies with FCC Rules Part 15 and Industry Canada RSS-210 (Rev. 7). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme au x CNR d'Industri e Canada appl icables au x appareils radio e xempts de lice nce. L'exploitat ion est autorise au x deux condit ions suivantes:
(1) l'appareil ne doit pas produi re de br ouill a ge, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. The digital circuitr y of this devic e has b een teste d and foun d to com ply with t h e l im i ts f or a C lass B digital devi c e, pursuant to P art 15 of the FC C R ul es. T he s e li m its are designed to provide reasonable protection against harmful interference in resid ential installations. This equipment generates, uses, and can radiate radio frequency energy and, if not ins tall e d a nd us e d in accordance with th e in s tr uct i ons, m a y c aus e harmful interfer enc e to radio and tel e vis io n r ec e ptio n. However, ther e is no guarantee t hat inter feren ce w ill n ot occu r i n a p articul ar i nst allati on. If thi s devic e does cause su ch i nterf erenc e, which c an b e v erified by turni ng th e d evice off and on, the user is encouraged to eliminate the interference by one or more of the following measures:
- Re-orient or relocate the receiving antenna of the device experiencing the interference
- Increase the distance between this device and the receiver
- Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver
- Consult the dealer or an experienced radio/TV technician WARNING: Changes or modi fications to t his device n ot expressl y approved b y the party respo nsible for c ompliance co uld void the user’s authori ty to operate t he equipment.

Declaration of Conformity

Hereby, INSTEON declares that this device is in compliance with the essential requir ements and other relevant pro v isions of the following Directi v es:
1) Low Voltage Equipment Directive 2006/95/EC
2) Electromagnetic Compatibility Directive 2004/108/EC
3) Hazardous Substance Directive 2005/95/EC Technical data and copies of the original Declaration of Conformity are available and can be obtained from INSTEON; 16542 Millikan Ave, Irvine, CA, USA. User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE) This document contains important information for users with regards to the proper disposal and recycling of INSTEON products. Consumers are required to comply with this notice for all electronic products bearing the following symbol:
Environmental Information for Customers in the European Union European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local autho rities, waste disposal service, or the shop where you purchased the product.
DECLARATION OF CONFORMITY TO R&TTE DIRECTIVE 1999/5/EC for the European Community, Switzerland, Norway, Iceland and Liechtenstein Product category: general consumer (category 3). English: This equipment is in compliance with the essential requirements and other relevant provisions of the European R&TTE Directi ve 19 99/5/EC Deutsch [German]: Dies es G e rät en tsp ri cht de n gru ndlegenden Anforder un ge n und den weiteren entsprec henden Vorgaben der Richtlinie 1999/5/EU. Nederlands [Dutch]: Dit apparaat voldoet aan de essentiele eisen en andere van toepassing zijnde bepalingen van de Richtlijn 1999/5/EC. Svenska [Swedish]: Denna utrustning står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Français [French]: Cet appareil est conforme aux exigences essentielles et aux autres dispositions pertinentes de la Directive 1999/5/EC Español [Spanish]: Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directiva 1999/5/CE. Português [Portuguese]: Este equipamento está em conformidade com os requisitos essenciais e outras provisões relevantes da Directiva 1999/5/EC. Italiano [Italian]: Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/CE. Norsk [Norwegian]: Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-direktiv 1999/5/EF. Suomi [Finnish]:Tämä laite tÿttää direktiivin 1999/5/EY olennaiset vaatimukset ja on siinä asetettujen muiden laitetta koskevien määräysten mukainen. Dansk [Danish]: Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Direktiv 1999/5/EF. Polski [Polish]: Urządzenie jest zgodne z ogólnymi wymaganiami oraz szczególnymi warunkami okreslonymi Dyrektywą UE: 1999/5/EC

ETL/UL Warning (Safety Warning)

CAUTION: To reduce the risk of overh eat i ng an d pos sible damage to ot he r e qui pm e nt, do not install this device to cont rol a rec eptacle, a motor-op er at e d a ppli a nce , a fluorescent lighting fixture, or a transformer-suppl i ed ap pl ian c e. Gradateurs comman dant une D IN Raile a filament d e tungs tene – afin de reduire le risqu é de su rchauf fe et la pos sibi lite d’e ndom magem ent a d’a utres m at eriels, ne pas installer pour commander une prise, un appareil a moteur, une DIN Raile fluorescente ou un appareil alimente par un transformateur.

Limited Warranty

Seller warrants to the original consum er purc haser of this product that, f or a period of two years from the d ate of p urchas e, this product will b e free f rom def ects in material and work m ans hip an d wil l p erf orm i n su bs ta ntial conformity t o the d es c ription of the pro duct i n this Owner’s Manual. This warrant y shall n ot ap ply to defects or errors caused b y misuse or neglect . If the product is foun d to be defective in m aterial or workm anship, or if the product does not perform as warranted above during the warrant y perio d, Sell er will either repai r it, r eplac e it, or refund the p urchas e pric e, at its o ptio n, upo n recei pt of t he pro duct at t he ad dres s belo w, post age prepaid, with proof of the dat e of purchase and an expl anation of the defec t or error. The repair, re placement, or re fund that is provi ded for ab ove shall be the full
Page 24
extent of Seller’s liabilit y with respect to this product. For repai r or replacement during the warrant y period, call INSTEON at 866-243-8022 with the Mod el # and Revision # of the device to receive an RMA# and send the product, along with all other required materials to:
INSTEON ATTN: Receiving 16542 Millikan Ave. Irvine, CA 92606-5027

Limitations

The above warranty is in l ieu of and Seller dis claims all other warr anties, whether or al or written, express o r implied, includin g any warranty or merchantability or fitness for a pa rticular pu rpose. An y implied warranty, in cluding an y warran ty of merch antabilit y or fitnes s for a pa rticular purpose, which may not be discl aimed or supplanted as p rovide d abov e s hall be lim ited t o the two-year of the express warran ty abo ve. No ot her r epres entati on o r clai m of an y nature by an y p erson shall be binding upon Seller or modify the terms of the above warranty and disclaimer. Home automation d evices have th e risk of fai lure to operate, in correct op eration, o r electrical or m echanical tam pering. F or optimal us e, manually v erify the devic e state. Any home automation device should be viewed as a convenience, but not as a sole method for controlling your home.
In no event shall S eller be l iable for speci al, incid ental, c onseque ntial, or other dam ages r esulting from pos sessi on or us e of this device, includin g witho ut lim itation damage to proper ty and, to the e xtent perm itted by law, personal i njury, ev en if S eller k new or sho uld hav e known o f the p ossibility of such damages. Som e states do not allow limitatio ns on how long an im plied warranty las ts and/or the exc lusion or limitatio n of damages, in w hich case the abov e limitations and/ or exclusions may not apply to you. You may also hav e othe r legal rig hts tha t ma y vary from state to state.
Protected under U.S and foreign patents (see www.insteon.com/patents © Copyright 2013 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 866-243-8022, www.insteon.com
)
Page 24 of 24 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM