INSTEON 2441 User Manual

Page 1
Thermostat Adapter
INSTEON® and Totaline/Venstar Compatible (Rev 2.0+)
Model :
2441
Page 2
Thermostat Adapter Owner’s Manual (Rev 2.0+)
TABLE OF CONTENTS
ABOUT THERMOSTAT ADAPTER ............................................................................................................. 3
Key Thermostat Adapter Features ............................................................................................................ 3
What is Included with Thermostat Adapter ................................................................................................ 3
WHAT IS INSTEON? .................................................................................................................................... 4
INSTALLATION ............................................................................................................................................ 4
Installing Thermostat Adapter.................................................................................................................... 4
Uninstalling Thermostat Adapter ............................................................................................................... 4
CONTROLLING THERMOSTAT ADAPTER FROM AN INSTEON CONTROLER .................................... 5
Linking an INSTEON Controller to Thermostat Adapter ........................................................................... 5
Unlinking Thermostat Adapter from an INSTEON Controller .................................................................... 6
Remotely Controlling your T hermostat ...................................................................................................... 6
CONTROLLING INSTEON RESPONDERS FROM THERMOSTAT ADAPTER ........................................ 7
Linking Thermostat Adapter to an INSTEON Responder ......................................................................... 7
Unlinking an INSTEON Responder from Thermostat Adapter .................................................................. 7
Reporting Changes to Compatible Automation Controller/Software ......................................................... 8
ADVANCED FEATURES ............................................................................................................................. 9
Restoring Power to Thermostat Adapter ................................................................................................... 9
Resetting Thermostat Adapter to its Factory Default Settings .................................................................. 9
ABOUT INSTEON ...................................................................................................................................... 10
Using Dual-Band INSTEON Devices to Upgrade Your Network ............................................................. 10
Important Note about INSTEON Networks; Split Single-Phase vs. 3-Phase Installation........................ 10
Further Enhancing Reliability .................................................................................................................. 10
ADDITIONAL RESOURCES ...................................................................................................................... 10
TROUBLESHOOTING ................................................................................................................................ 11
SPECIFICATIONS, CERTIFICATION, AND WARRANTY ........................................................................ 11
Specifications .......................................................................................................................................... 11
Certification .............................................................................................................................................. 11
FCC & Industry Canada Compliance Statement ..................................................................................... 12
Limited Warranty ..................................................................................................................................... 12
Page 3
Thermostat Adapter Owner’s Manual (Rev 2.0+)
Set button
Status LED

ABOUT THERMOSTAT ADAPTER

Thermostat Adapter a llows you to use th e power of INSTEON to c ontrol the temper ature of your home, from anywhere in t he house. R ecal l store d set points and m ode s ettings from any IN STEO N Contr oller to maintain comfort and save energy.

Key Thermostat Adapter Features

Installs and Links to other INSTEON devices in minutes
Saves energy and money on bills by remotely controlling your thermostat
Communicates wirelessly over radio frequency (RF)
Compatible with Totaline/Venstar T1700, T1800, and T1900 thermostats
Powered through your thermostat – no batteries needed
Automatically contro ls rem ote INST EON de vic es whe n the therm os tat switc hes A/C, heat , and f an on
or off
Reports changes in thermostat modes, temperature, and humidity to compatible automation controllers or software
Fine-tunes therm ostat set points by s ingle degrees from any I NSTEON contro ller with s pecific Bright and Dim buttons
Stores setup state in memory so settings aren’t lost during power outages
Two-year warranty

What is Included with Thermostat Adapter

Thermostat Adapter – INSTEON and Totaline/Venstar Compat ible
Quick-Start Guide
Page 3 of 13
Page 4
Thermostat Adapter Owner’s Manual (Rev 2.0+)

WHAT IS INSTEON?

Since its inception in 2005, INSTEON has become a best-selling home-control networking technology, offering more reliability and flexibility than any other home management system on the market. INSTEON systems are sim ple, reliable, a nd affor dable. Simple, because each device tak es mere minutes to install. Reliable, because ever y INST EON dev ice work s as a network repeater, e nsurin g your c omm ands will not be lost. Affordable, bec ause INST EON can be int egrated i nto any num ber of devic es easil y and at a very low cost. An INSTEON home grows in value with each added INSTEON device, making life more convenient, safe, and fun.
How Does INSTEON Work?
What makes INST EON the most reliable hom e automation network is its dual-mesh net work. INSTEON devices use both radio frequenc y (RF) signals and the hom e’s existing wiring to talk to eac h other. In an INSTEON network, every INSTEON device also acts as a repeater, receiving and sending every message to all other devices in the network. So by integrating more INSTEON devices you will strengthen the network and ensure no commands will be lost.
No central controller or networking setup is required with an INSTEON network. Simply install your devices and th en use a series of button presses or taps to Link your devices together. Throughout thi s Owner’s Manual, you may see the terms “Controller” or “Responder”. These generic INSTEON terms refer to the components of an INSTEON scene, and are used on a scene-by-scene basis.
Controller – sends INSTEON commands to other devices
Responder – reacts to commands sent out by another INSTEON device
An INSTEON device may act as a Controller, Responder, or sometimes both. INSTEON network s are also extremely secure. Each INSTEON device is assigned a unique INSTEON
ID, so unless neighbors or would-be hackers have acces s to your particular device’s INST EON ID, they won’t be able to control your home, even if they are using similar products.

INSTALLATION

Installing Thermostat Adapter

Before installing Thermostat Adapter, be sure that you have properly installed a compatible Totaline/Venstar thermostat.
1) RF-only devices require at leas t one dual-band INST EON device, such as an Access Point (#2443), for communication. F or the best IN STEON network perform ance, be sure you have properly installe d at least two dual-band devices.
2) Plug Thermostat Adapter into the jack on the bottom of your thermostat
The Thermostat Adapter Status LED will turn on solid green

Uninstalling Thermostat Adapter

1) Open the front cover of your thermostat by gently pulling the right edge of the cover towards you
2) While pressing firmly on the small round button (located on the bottom center of the thermostat), gently pull down on Thermostat Adapter
The Thermostat Adapter Status LED will turn off
Page 4 of 13
Page 5
Thermostat Adapter Owner’s Manual (Rev 2.0+)
1) Set the Controller to Linkin g Mode . ( For m os t Contr oller s, pr es s & hold an O n or Sc ene b utto n f or 10
2) To Link to an On button: Set your thermostat to the desired mode
(Manual/Program/Auto, Heat/Cool, Temperature, Fan
Tap the Set button on Thermostat Adapter
3) To Link to an Off button:
Set your thermostat to the desired mode (Manual/Program/Auto, Heat/Cool, Temperature, Fan
Double-tap the Set button on Thermostat Adapter
4) Test that Linking was succ essful by changin g the mode on your thermostat and tapp ing the buttons

CONTROLLING THERMOST AT ADAPTER FROM AN INSTEON CONTROLER

Linking an INSTEON Controller to Thermostat Adapter

Thermostat Adapter inc ludes a specia l feature th at all ows you to Link individua l com m ands to the On and Off buttons on your Contr oller. For example, you ca n Link the heat to turn on when you press the On button and Link the fan to turn on when you press the Off button on your Controller.
NOTE: Each of the buttons must be Linked separately. If you only Link to the On button, nothing will happen when you press the Off button, unless you specifically program an action to it.
The following will work for the most common INSTEON devices:
seconds or the Set button for 3 seconds.) You will have 4 minutes to complete steps 2 and 3 before Linking Mode automatically times out.
Auto/Fan On)
Press & hold the Set button on Thermostat Adapter for 3 seconds
The thermostat display will flas h all the LC D characters twice
NOTE: Not all INSTEON devices have the ab ility to be Linked to an Off button (see the device’s Owner’s Manual).
Auto/Fan On)
Press & hold the Set button on Thermostat Adapter for 3 seconds
The thermostat display will flas h all the LC D ch aracter s twice
you just Linked to on the Controller NOTE: Different set points can be Linked to different buttons should you need more flexibility.
5) If your Controller is a m ulti-s cene device, you can repeat s teps 1 thr ough 4 for a s man y scenes and set points on your Controller as you wish
Page 5 of 13
Page 6
Thermostat Adapter Owner’s Manual (Rev 2.0+)

Unlinking Thermostat Adapter from an INSTEON Controller

If you are going to discontinue usin g Thermostat Adapter , it is very important that you Unl ink it from any Linked Controllers. O th er wis e, the C on trol lers will retry any commands repetit ively, thus slowing down the system.
NOTE: If you Unlink Thermostat Adapter from a single button of an On/Off button pair, any Linked commands for the Co ntroller will be er ased, e ven if th e comm ands were Li nked t o separate buttons. You will have to re-Link the commands you wish to continue using on your Controller.
The following wil l work for the most common INSTEON devices:
1) Set the Controller to Unlinking Mo de. (For mos t Controllers, press & hold an O n or Scene butt on for 10 seconds twice or the Set button for 3 seconds twice.)
You will have 4 minutes to complete the steps 2 and 3 before Unlinking Mode automatically times out.
2) Tap the Set button on Thermostat Adapter
3) Press & hold the Set button on Thermostat Adapter for 3 seconds
The thermostat display will flash all the LCD characters twice
4) Confirm that Unlinking was successful by tapping the buttons you just Unlinked from on the Controller
5) If there are any comm ands you would lik e to continu e using with the C ontroller, r e-Link them with the prior settings. See L inki ng an IN STEON Controller to Thermostat Adapter.

Remotely Controlling your Thermostat

Recalling Mode / Set Points
Once you have L ink ed a Controller to Thermostat Ad a pter , you can recall the mode and set po int setti ngs programmed during Linking by tapping the On button on the Controller.
Temperature Set Point Adjustments
Some devices, such as R emoteLinc (#244 0), have spec ific Dim and Bright buttons which can be used to adjust the current thermostat set point up or down by a single degree.
1) Recall a mode/set point by tapping an On button from a Linked Controller
2) Tap the Bright but ton to incr ease or the D im button to decreas e the tem perature. Eac h butt on tap w ill adjust the temperature by a single degree.
NOTE: W hile pres sing & holding On or Off buttons does d im and brighten ot her INSTEON devices , Thermostat Adapter will ignore those types of dim/bright commands to prevent “runaway” temperature set points.
Page 6 of 13
Page 7
Thermostat Adapter Owner’s Manual (Rev 2.0+)

CONTROLLING INSTEON RES P O NDERS FROM THERMOSTAT ADAPTER

Linking Thermostat Adapter to an INSTEON Responder

Thermostat Adapter can tu rn INSTEON Responders on and off when the thermostat switches the A/C, heat, and/or fan on and off. T his feature is us eful for s ynchroni zing your ther mos tat with other IN STEON ­compatible thermostats or equipment, such as booster fans, dampers, etc.
A/C – Turns Respond ers o n whe n the ther mostat turns on the A/C a nd off when the A/C is turned
off
Heat - Turns Responders on when the therm ostat turns on the heater a nd off when the heater is
turned of
Fan – Turns Responders on when the fan is turned on manual or via thermostat timer and off
when the fan is turned off. NOTE: Although the f an is used d ur in g h eat and A /C modes, Responder s w ill onl y tur n o n a nd off
when the fan is controlled manually, by a Controller, or via thermostat timer.
The following will work for the most common INSTEON devices:
1) Set the thermostat to the d esired m ode (A/C, H eat, FanO n). If you are us ing the FanOn m ode, mak e sure to also set your thermostat to Off mode.
2) Press & hold the Set button on Thermostat Adapter for 3 seconds
The Thermostat Adapter Status LED will begin blinking The thermostat display will flash all the LCD characters once
3) Press & hold the Responder’s Set button for 3 seconds
The Thermostat Adapter Status LED will stop blinking The thermostat display will flash all th e LCD characters once
4) Confirm that Linking was successfully by manually changing the mode on the thermostat
The Responder will respond appropriately

Unlinking an INSTEON Responder from Thermostat Adapter

If you are no longer going to use an INSTEON Responder that has bee n Link ed to T herm ostat Adapter , it is very important that you Unlink it. Otherwise, Thermostat Adap ter will retry an y commands repetitively, thus slowing down the system.
The following will work for the most common INSTEON devices:
1) Press & hold the Set button on Thermostat Adapter for 3 seconds
The Thermostat Adapter Status LED will begin blinking The thermostat display will flash all the LCD characters once
2) Press & hold the Set button on Thermostat Adapter for 3 seconds again
The Thermostat Adapter Status LED will continue blinking
The thermostat display will flash all the LCD characters once
3) Press & hold the Responder’s Set button for 3 seconds
The Thermostat Adapter Status LED will stop blinking The thermostat display will flash all the LCD characters once
4) Confirm that Unlinking was successful by manually changing the mode on the thermostat
The Responder will no longer respond
Page 7 of 13
Page 8
Thermostat Adapter Owner’s Manual (Rev 2.0+)

Reporting Changes to Compatible Automation Controller/Softw are

Thermostat Adapter will report the following changes to an INSTEON-compatible home automation software once a change has been “stabilized” for at least 2 minutes:
Temperature
Humidity
Thermostat mode
Fan mode
Set points
NOTE: Thermostat Adapter will only report changes to the last device it was Linked to, using the instructions below. To change the interface to which you’d like the changes to be reported, follow the “Enable” instructions with the new interface as the Responder.
While Thermos tat Adapt er wil l rep ort t o a n y aut omation controller or int er f ace you Link to via the fol lo win g instructions, check the software’s documentation about compatibility with this feature.
Enabling Change Reports
1) Set the thermostat to Off mode
2) Press & hold the Set button on Thermostat Adapter for 3 seconds
The Thermostat Adapter Status LED will begin blinking The thermostat display will flash all the LCD characters once
3) Press & hold the Responder’s Set button for 3 seconds
The Thermostat Adapter Status LED will stop blinking The thermostat display will flash all the LCD characters once
Disabling Change Reports
1) Set the thermostat to Off mode
2) Press & hold the Set button Thermostat Adapter for 3 seconds
The Thermostat Adapter Status LED will begin blinking The thermostat display will flash all the LCD characters once
3) Press & hold the Set button on Thermostat Adapter for 3 seconds again
The Thermostat Adapter Status LED will continue blinking The thermostat display will flash all the LCD characters once
4) Press & hold the Responder’s Set button for 3 seconds
The Thermostat Adapter Status LED will stop blinking The thermostat display will flash all the LCD characters once
Page 8 of 13
Page 9
Thermostat Adapter Owner’s Manual (Rev 2.0+)

ADVANCED FEATURES

Restoring Power to Thermostat Adapter

Thermostat Adapter s tores all of its settings, such as Link s to other INSTEON devices, with non-volatile memory. Because set tings are saved in this non-volatile memor y, they will not be lost in the event of a power failure.
In the event of a power loss Thermostat Adapter will automatically return the load to the state it had before power was interrupted.

Resetting Thermostat Adapter to its Factory Default Settings

The factory reset proc edure can b e used to c lear the Therm ostat Adapter memory of all I NSTEO N Link s, set points, etc.
1) If you are using a Controller to control Thermostat Adapter, be s ure to Unlink it from the Controller. See Unlinking Therm os tat Ada pter from an INSTEON Controller.
2) If you are using Thermostat Adapter to control any Responders, Unlink them from Thermostat Adapter. See Unlinking an IN STEON Res po nder from Thermostat Adapter.
3) Unplug Thermostat Adapter from your thermostat
Open the cover of the thermostat
While pressing & holding the small round button (located on the bottom center of the
thermostat), gently pull down on Thermostat Adapter
The Thermostat Adapter Status LED will turn off
4) Wait 10 seconds
5) While pressing & ho lding the Set button on Thermostat Adap ter, plug it back into your therm ostat, making sure not to let go of the Set button
6) Continue to hold the Set button for 3 seconds and then release
The Thermostat Adapter Status LED will stay off for about 20 seconds and then turn on The thermostat display will flash all the LCD characters three times and then return to normal
operation The Thermostat Adapter Status LED will flicker for a few moments and then turn on solid
Page 9 of 13
Page 10
Thermostat Adapter Owner’s Manual (Rev 2.0+)

ABOUT INSTEON

Using Dual-Band INSTEON Devices to Upgrade Your Network

What are phases?
The majority of single-family homes in North America have two phases (or “legs”) of 110 Volts coming into their electricity panels. From the panel, they are distributed throughout the home, providing power to outlets and wall switches. These phases come together in some parts of the home to provide 220 Volts of power to large appliances, such as an electric oven or pool pump.
Why do I need to bridge these phases?
Single-band power line devices send commands via the home’s electricity, but only on a single phase. If the command is intended for a device on the opposite phase, there is a good chance the command will go unnoticed. Installing dual-band INSTEON devices, such as Access Points (#2443), on each phase will allow for devices to communicate between the two phases via RF.
Dual-band INSTEON devices embody the full potential of a true INSTEON mesh network. Taking the power line band signal and working in conjunction with the RF band signal, its dual-band function plays out in two ways:
Phase bridger – a receiver of commands, reacting to and translating signals sent from one power
phase to the opposite via RF
Signal repeater – a participant in an INSTEON network, repeating commands intended for other
devices whether those commands are generated from RF or power line-only devices. To ensure reliability, every INSTEON device confirms that it has received a command. If a Controll er does not receive this confirmation, it will automatically retransmit the command up to five times.
While using at least one dual-band device is required when using an RF-only device, at least two dual-band devices are recommended in any INSTEON network to ensure reliable communication across two-phase home wiring systems. For larger applications, it is recommended to install at least one dual-band device for every 750 – 1,000 square feet.
Search for dual-band INSTEON devices at: www.smarthome.com/dualband

Important Note about INSTEON Networks; Split Single-Phase vs. 3-Phase Installation

For the best INSTEON network performance, be sure you have properly installed at least two dual-band INSTEON devices. INSTEON has only been officially tested in a split single-phase residential environment but has been known to work in many 3-phase systems, where three dual-band devices are used (one on each phase). However, due to the potential complexity of its troubleshooting, the INSTEON Gold Support Line is unable to support INSTEON in 3-phase environments.

Further Enhancing Reliability

As signals travel via the power line or RF throughout the home, they naturally beco me weaker the farther they travel. The best way to overcome weakened signals is to increase the coverage of the mesh network by introducing more INSTEON devices.
It is possible that some audio-video devices, computers, power strips, or other electrical equipment may attenuate INSTEON signals on the power line. You can temporarily unplug suspected devic es to test whether the INSTEON signal improves. If it does, then you can plug in filters that will permanently fix the problem.

ADDITIONAL RESOURCES

Find home automation solutions, helpful tips, interactive demos, videos, user forums, and more at the Smarthome Learning Center: www.smarthome.com/learningcenter.html
Page 10 of 13
Page 11
Thermostat Adapter Owner’s Manual (Rev 2.0+)
Problem
Possible Cause
Solution
Make sure that Thermostat Adapter is properly installed.
Add additional INSTEON devices or move around as INSTEON network repeaters.
Thermostat Adapter may command.
Be sure you have properly installed at least one dual­between the units.

TROUBLESHOOTING

The Status LED on Thermostat Adapter is not turning on at all.
Thermostat Adapter won’t Link or work with a Controller.
If you have tried these solutions, reviewed this Owner’s Manual, and still cannot resolve an issue you are having with Thermostat Adapter, please call:
Thermostat Adapter may not be getting power.
The Controller might have been reset without Unlinking Thermostat Adapter from it.
The INSTEON signal may be too weak.
not be receiving the RF
INSTEON Gold Support Line
800-762-7845
Make sure your thermostat is working properly.
Re-Link Thermostat Adapter to the Controller.
existing INSTEON devices. All INSTEON devices act
band INSTEON device to ensure communication

SPECIFICATIONS, CERTIFICATION, AND WARRANTY

Specifications

View specifications for Thermostat Adapter at: www.smarthome.com/2441V.html

Certification

This product has been thoroughly tested by ITS ETL SEMKO, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S. and Canadian device safety standards, that the manufacturing site has been audited, and that the manufacturer has agreed to a program of quarterly factory follow-up inspections to verify continued conformance.
Page 11 of 13
Page 12
Thermostat Adapter Owner’s Manual (Rev 2.0+)

FCC & Industry Canada Compliance Statement

This device complies with FCC Rules Part 15 and Industry Canada RSS-210 (Rev. 7). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference, including interference that may cause undesired operation of
the device.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est
susceptible d'en compromettre le fonctionnement.
The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures:
Re-orient or relocate the receiving antenna of the device experiencing the interference
Increase the distance between this device and the receiver
Connect the device to an AC outlet on a circuit different from the one that supplies power to the
receiver
Consult the dealer or an experienced radio/TV technician
WARNING: Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Limited Warranty

Seller warrants to the original consumer purchaser of this product that, for a period of two years f rom the date of purchase, this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to def ects or errors caused by misuse or neglect. If the product is found to be def ective in material or wo rkmanship, or if the product does not perform as warranted above during the warranty period, Seller will either repair it, replace it, or refund the purchase price, at its option, upon receipt of the product at the address below, postage prepaid, with proof of the date of purchase and an explanation of the defect or error. The repair, replacement, or refund that is provided for above shall be the full extent of Seller’s liability with respect to this product. For repair or replacement during the warranty period, call the INSTEON Gold Support Line at 800-762-7845 with the Model # and Revision # of the device to receive an RMA# and send the product, along with all other required materials to:
Smarthome, Inc. ATTN: Receiving Dept. 16542 Millikan Ave. Irvine, CA 92606-5027
Page 12 of 13
Page 13
Thermostat Adapter Owner’s Manual (Rev 2.0+)

Limitations

The above warranty is in lieu of and Seller disclaims all other warranties, whether oral or written, express or implied, including any warranty or merchantability or fitness for a particular purpose. Any implied warranty, including any warranty of merchantability or fitness for a particular purpose, which may not be disclaimed or supplanted as provided above shall be limited to the two-year of the express warranty above. No other representation or claim of any nature by any person shall be binding upon Sell er or modify the terms of the above warranty and disclaimer.
Home automation devices have the risk of failure to operate, incorrect operation, or electrical or mechanical tampering. For optimal use, manually verify the device state. Any home automation device should be viewed as a convenience, but not as a sole method for controlling your home.
In no event shall Seller be liable for special, incidental, consequential, or other damages resulting from possession or use of this device, including without limitation damage to property and, to the extent permitted by law, personal injury, even if Seller knew or should have known of the possibility of such damages. Some states do not allow limitations on how long an implied warranty las ts and/or the exclusion or limitation of damages, in which case the above limitations and/or exclusions may not apply to you. You may also have other legal rights that may vary from state to state.

INSTEON Technology Patent

U.S Patent No. 7,345,998, International patents pending
© Copyright 2011 Smarthome, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845, www.smarthome.com
Rev 04-12-2011
Page 13 of 13
Loading...