
GW INSTEK PART NO. 82EL-31110MD1
ISO-9001 CERTIFIED MANUFACTURER
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Visit us at www.TestEquipmentDepot.com
Toll Free 1-800-517-8431

This manual contains proprietary information, which is
protected by copyright. All rights are reserved. No part
of this manual may be photocopied, reproduced or
translated to another language without prior written
consent of Good Will Corporation.
The information in this manual was correct at the time
of printing. However, Good Will continues to improve
its products and therefore reserves the right to change
the specifications, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng
Dist., New Taipei City 236, Taiwan.

SAFETY INSTRUCTIONS
Warning: Identifies conditions or
practices that could result in injury or
loss of life.
Caution: Identifies conditions or
practices that could result in damage
to the instrument or to other
properties.
Attention Refer to the Manual
Protective Conductor Terminal
Do not dispose electronic equipment
as unsorted municipal waste. Please
use a separate collection facility or
contact the supplier from which this
instrument was purchased.
This section contains the basic safety symbols that may
appear on the accompanying User Manual CD or on the
instrument. For detailed safety instructions and
precautions, please see the Safety Instructions chapter
in the user manual CD.
Safety Symbols
These safety symbols may appear in the user manual or
on the instrument.

Power Cord for the United Kingdom
When using the instrument in the United Kingdom,
make sure the power cord meets the following safety
instructions.
NOTE: This lead/appliance must only be wired by
competent persons.
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in
accordance with the following code:
As the colours of the wires in main leads may not correspond with
the coloured marking identified in your plug/appliance, proceed as
follows:
The wire which is coloured Green & Yellow must be connected to
the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal
marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or
contact the supplier.
This cable/appliance should be protected by a suitably rated and
approved HBC mains fuse: refer to the rating information on the
equipment and/or user instructions for details. As a guide, a cable of
0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors
would normally require 13A types, depending on the connection
method used.
Any exposed wiring from a cable, plug or connection that is engaged
in a live socket is extremely hazardous. If a cable or plug is deemed
hazardous, turn off the mains power and remove the cable, any
fuses and fuse assemblies. All hazardous wiring must be
immediately destroyed and replaced in accordance to the above
standard.

GETTING STARTED
• High slew rates of up to
16A/μS(PEL-3111),0.8A/μS(PEL3111H) for a fast response speed
The Getting Started chapter introduces the instrument’s
main features, appearance, and set up procedure.
Overview
The PEL-3000(H) Series is a family of high performance
DC electronic loads positioned to test a wide range of
different power sources. The DC electronic loads are
fully programmable to simulate anything from basic
static loads to complex dynamic loads. With the ability
to operate independently or in parallel, the PEL-3000(H)
Series is extremely robust and capable of molding to
any test environment.
Model Line Up
Main Features

• High capacity when used in
parallel:
5250W, 1050A(262.5A),
PEL-3111(H) x 5)
9450W, 1890A(472.5A),
PEL-3111(H) + PEL-3211(H) x 4)
• High resolution – 16 bit
• 7 operating modes: CC, CV, CR,
CP, CC+CV, CR+CV, CP+CV
• Independent and parallel
operation
• Fully programmable with normal
and fast sequences
• Soft start
• Dynamic mode
• OCP, OVP and other protection
features
• Remote sense
• Integrated meter
• Rack-mountable
• Load booster
• USB, RS232 and GPIB
• External voltage or resistance
control
• Front panel trigger out BNC
• Front panel current (voltage)
monitoring BNC
• Analog external control

Package Contents and Accessories
User /Programming Manual CD
Quick Start Guide (this document)
Load input terminal Cover, M3
screw x1
Terminal fittings: 2 sets of
bolts/nuts/springs/washers (type:
M8), terminal cover x1 (for PEL3000H series only), monitor out
cover x 1(for PEL-3021H, PEL3041H, PEL-3111H only)
Flexible terminal cover: 2x rubber
sheeting, 4x Velcro fasteners.(for
PEL-3211(H)only)
PEL-013
J1/J2 Protection plug x2 (It is
installed on the device)
PEL-014
Front terminal washers (M6) x2
300mm Frame Link Cable (for
linking units that are stacked).
Note that this accessories is
optional for the PEL-3021(H)/
3041(H)
Rack mount bracket for booster
PEL-3211(H) (EIA + JIS)
Rack mount frame for PEL3021(H), PEL-3041(H), PEL3111(H)/EIA

Rack mount frame for PEL3021(H), PEL-3041(H), PEL3111(H)/JIS
USB cable. Type A - Type B
CR123A 3V lithium battery for
clock.
3813-030D0501
Connect Cu Plate

PEL-3111
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/
Off
Main
Help
FUNC
Short
TRIG
OUT
I MON
OUT
1.5 - 150V
1050W
0 - 70A
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/
Off
Main
Help
FUNC
Short
TRIG OUT
I
MON OUT
5 - 800V
1050W
0 – 52.5A
V
MON OUT
A/B
11. Number pad, Clear/
Lock and Enter keys
12. USB port, Preset and
Shift keys
13. I MON OUT and TRIG
OUT(for PEL-3000
series)
I MON OUT, V MON
OUT, TRIG OUT(for
PEL-3000H series)
PEL-3111H
PEL-3211(H) Booster Pack

Rear Panel
47 - 63 Hz
90 VA MAX.
AC
100 - 120 VAC
200 - 240 VAC
FRAME CONT
J 1
J 2
SER. NO. LB
RS232C
GPIB
WARNING
TO AVOID ELECTRIC SHOCK THE POWER CORD
DO NOT REMOVE COVERS.
NO OPERATOR SERVICEABLE COMPONENTS INSIDE.
PROTECTIVE GROUNDING CONDUCTOR MUST BE
REFER SERVICING TO QUALIFIED PERSONNEL.
CONNECTED TO GROUND.
47 - 63 Hz
90 VA MAX.
AC
100 -120 VAC
200 -240 VAC
FRAME CONT
J 1
J 2
RS232C
GPIB
VR1 VR2 VR3 VR4
V/I MON OUT
1
1 2
3
9
8
7
6
5
4
10
11
PEL-3021 and PEL-3041
PEL-3021H and PEL-3041H

PEL-3111
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/
Off
Main
Help
FUNC
Short
TRIG
OUT
I MON
OUT
1.5 - 150V
1050W
0 - 70A
1. Frame control ports, J1, J2
5. Power socket and switch
PEL-3111H
PEL-3211 Booster Pack
PEL-3211H Booster Pack

Display Overview
ModeCVI Range
H 35A
V Range
L 15V
Function
Static
Configure
0.000
V
0.000A
0.00w
SlewRate 2500.00
CC B Value 0.000
CC A Value 0.000
LOADRS232
A Value
Fine
03/Sep/2012
mA/us
A
A
2. Main frame status panel
3. Operation status panel
Use the following procedures when first using the
PEL-3000(H) to power up the instrument, set the
internal clock, restore the factory default settings and
check the firmware version. Lastly, the Conventions
section will introduce you to the basic operating
conventions used throughout the user manual.
1. Insert the AC power cord into the power socket.
2. Turn the power switch on
from the rear panel.
(O → —)
First Time Use Instructions
Power Up

3. If the unit doesn’t turn on, press the ON/STBY key
on the front panel.
The ON/STBY key will go from standby (red)
to ON (green).
4. The unit will show the splash screen and then load
the settings from when the unit was last powered
down.
Load Default Settings
When first using the PEL-3000(H), recall the factory
default settings to ensure the unit is in a known state.
See the user manual for a list of the default settings.
.
2. Select Media/Default [F1].
3. Select Factory Default [F2].
4. Press Factory Default [F2] again to confirm.
The date and time settings are used to time-stamp files
when saving files.
> Time Set[F4] to set the
date and time.
Settings: Month, Day, Year, Hour, Minute
Setting the Date and Time

Updating the Firmware
The PEL-3000(H) allows the firmware to be updated by
end-users. Before using the PEL-3000(H), please check
the GW Instek website or ask your local distributor for
the latest firmware. Before updating the firmware,
please check the firmware version.
.
2. Select System/Info[F1].
3. The system information is listed in the display.
Model: PEL-3000(H) model number.
Serial Number: XXXXXXXX
Firmware Ver.: Firmware version number.
Website address.
1. Insert a USB drive into the USB port. Ensure the
USB drive has the firmware file located in the root
directory.
2. Press
.
3. Select USB with the Media [F1] soft-key.
4. Press the File Utility [F5] soft-key.
5. Select the *.UPG upgrade file and press Select[F1]
twice. Once to select the file and once to confirm.
6. Wait for the update to complete and reset the
power.

Do not turn the load generator off or
remove the USB memory when the
firmware is being read or upgraded.
Conventions
The following conventions are used throughout the
user manual. Read the conventions below for a basic
grasp of how to operate the PEL-3000(H) menu system
using the front panel keys.
The F1 to F5 function keys at the bottom of the
display correspond directly to the soft-menu keys
on top.
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/
Off
Main
Help
FUNC
Short
F1 ~ F5
function keys
Soft-menu
keys
ModeCVI Range
H 35A
V Range
L 15V
Function
Static
Configure
0.000
V
0.000A
0.00w
SlewRate 2500.00
CC B Value 0.000
CC A Value 0.000
LOADRS232
A Value
Fine
03/Sep/2012
mA/us
A
A
Pressing this type of soft-menu key will enter a
submenu.

Toggle Parameter or State
Mode
CC
Function/Item
Parameter or State
This type of soft-menu icon has the function/item
on the top of the label and the selected setting or
mode on the bottom of the label.
Repeatedly press the associated function key
(F1~F5) to cycle through each setting.
For some parameters, a popup window will also
appear. Selection of the setting is the same.
Repeatedly pressing the relevant function key
(F1~F5) will cycle through each setting.
The scroll wheel, Enter key and number pad can be
used to edit parameter values.
1. Use the scroll wheel to move the cursor to the
desired parameter.
A scroll bar is shown when there are additional
parameters off-screen.
ModeCPI Range
H 35A
V Range
L 15V
Function
Dynamic
Configure
0.000
V
0.000A
0.00w
Timer1 0.025
Level2 0.00
Level1 0.00
LOADRS232
Fine
03/Sep/2012
ms
W
W
key to select the parameter.
3. Then use umber pad* or scroll wheel** to edit the
parameter value.

ModeCCI Range
H 35A
V Range
L 15V
Function
Static
Configure
0.000
V
0.000A
0.00w
SlewRate 2500.00
CC B Value
CC A Value 0.000
LOADRS232
A Value
Fine
03/Sep/2012
mA/us
A
A
1.000
4. Press the Enter key again to finish editing the
parameter value.
*When editing a parameter with the number pad,
pressing the
key will restore the parameter
to the previous value.
**When a parameter is highlighted (step 3 above)
pressing the scroll wheel will toggle the scroll wheel
resolution between fine and coarse.
ModeCCI Range
H 35A
V Range
L 15V
Function
Static
Configure
0.000
V
0.000A
0.00w
SlewRate 2500.00
CC B Value
CC A Value 0.000
LOADRS232
A Value
Fine
03/09/12
mA/uS
A
A
1.000
+
Coarse/Fine
adjustment
Higlighted
parameter
Note: There is a second method of fine adjustment
that allows you to edit parameters one digit value at
a time using the scroll wheel. This is called
Cursor mode. Please see the user manual for more
information.

Entering Alphanumeric Characters
When renaming files, creating memos or notes,
you will be required to enter alphanumeric
characters when the character entry screen
appears.
Only alphanumeric characters as well as
space [ ], underscore [_] and minus [-]
characters are allowed.
1. Use the scroll wheel to move the cursor to the
desired character.
A B C D E F G H I J K L M
N O P Q R S T U V W X Y Z
1 2 3 4 5 6 7 8 9 0 _ 1
Rename:
Filename
Cursor
key or Enter Character[F1] to
select a character.
3. To delete a character, press Back Space[F2].
4. To save the file name or memo, press Save[F3].

SPECIFICATIONS
1.5V at 35A
(5V at 8.75A)
1.5V at 70A
(5V at 17.5A)
1.5V at 210A
(5V at 52.5A)
23.3336S-400μS
(42.857mΩ-
2.5kΩ)/(H)
1.75S-30μS
(571mΩ-33.3kΩ)
46.6672S-800μS
(21.428mΩ
-1.25kΩ)/(H)
3.5S-60μS
(285mΩ-16.6kΩ)
140.0016S~2.4mS
(7.1427mΩ-
416.6667Ω)/(H)
10.5S-200μS
(95.2mΩ-5kΩ)
2.33336S-40μS
(428.566mΩ
-25kΩ)/(H)
175mS-3μS
(5.71mΩ-333MΩ)
4.6667S-80μS
(214.28mΩ
-12.5kΩ)/(H)
35mS-6μS
(2.85mΩ-166kΩ)
14.0001S-242.4μS
(71.427mΩ
-4.16667kΩ)/(H)
1.05S-20μS
(952mΩ-50kΩ)
The following are the basic specifications for the PEL3000(H) series. For detailed specifications, please see
the user manual
Rating
CC Mode Operating Range
CR Mode Operating Range

0.233336S-4μS
(4.28566Ω
-250kΩ) /(H)
17.5mS-0.3μS
(57.1Ω-3.33MΩ)
0.46667S-8μS
(2.1428Ω
-125kΩ) /(H)
35mS-0.6μS
(28.5Ω-1.66kΩ)
1.40001S-24.24μS
(714.27mΩ
-41.6667kΩ) /(H)
105mS-2μS
(9.52Ω-500kΩ)
CV Mode Operating Range
2.5mA/μs
-2.5A/μs(H)
0.1400mA/μs-
140.0mA/μs
5mA/μs
-5A/μs(H)
0.280mA/μs-
280.0mA/μs
16.02mA/μs
-16.002A/μs
(H)0.840mA/μs-
840.0mA/μs
250uA/μs250mA/μs(H)
0.01400mA/μs-
14.000mA/μs
500uA/μs500mA/μs(H)
0.0280mA/μs-
28.00mA/μs
1.602mA/μs
-1.6002A/μs(H)
0.0840mA/μs-
84.00mA/μs
25uA/μs
-25mA/μs(H)
1.400μA/μs-
1400.0μA/μs
50uA/μs
-50mA/μs(H)
2.80μA/μs-
2800μA/μs
160.2uA/μs
-160.02mA/μs
(H)0.00840mA/
μs-8.400mA/μs
CP Mode Operating Range
Slew Rate CC Mode Setting Range

Slew Rate CR Mode Setting Range
250uA/μs
-250mA/μs(H)
0.01400mA/μs
-14.000mA/μs
500uA/μs
-500mA/μs(H)
0.0280mA/μs-
28.00mA/μs
1.602mA/μs
-1.6002A/μs(H)
0.0840mA/μs-
84.00mA/μs
25uA/μs
-25mA/μs(H)
0.001400mA/μ
s-1.4000mA/μs
50uA/μs
-50mA/μs(H)
0.00280mA/μs-
2.800mA/μs
160.2uA/μs
~160.02mA/μs
(H)0.0840mA/μ
s-8.400mA/μs
2.5uA/μs
-2.5mA/μs(H)
0.1400μA/μs-
140.00μA/μs
5uA/μs
-5mA/μs(H)
0.280μA/μs-
280.0μA/μs
16.02uA/μs
-16.002mA/μs
(H)0.00840mA/
μs-0.8400mA/μs

EC Declaration of Conformity (PEL-3000 series)
GOOD WILL INSTRUMENT CO., LTD.
No.7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan
PEL-3021, PEL-3041, PEL-3111
satisfies all the technical relations application to the product within
the scope of council:
Directive: 2014/30/EU; 2014/35/EU; 2011/65/EU; 2012/19/EU
The above product is in conformity with the following standards or
other normative documents:
EN 61326-1 :
EN 61326-2-1:
EN 61326-2-2:
Electrical equipment for measurement, control and
laboratory use –– EMC requirements (2006)
Conducted and Radiated Emissions
EN 55011: 2009+A1: 2010
Electrical Fast Transients
EN 61000-4-4: 2012
Current Harmonic
EN 61000-3-2: 2014
Surge Immunity
EN 61000-4-5: 2006
Voltage Fluctuation
EN 61000-3-3: 2013
Conducted Susceptibility
EN 61000-4-6: 2014
Electrostatic Discharge
EN 61000-4-2: 2009
Power Frequency Magnetic Field
EN 61000-4-8: 2010
Radiated Immunity
EN 61000-4-3: 2006 +A1: 2008+A2: 2010
Voltage Dips/ Interrupts
EN 61000-4-11: 2004
Low Voltage Equipment Directive 2006/95/EC
Safety Requirements: EN 61010-1: 2010; EN 61010-2-030: 2010

EC Declaration of Conformity (PEL-3000H series)
GOOD WILL INSTRUMENT CO., LTD.
No.7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan
PEL-3021H, PEL-3041H, PEL-3111H
satisfies all the technical relations application to the product within
the scope of council:
Directive: 2014/30/EU; 2014/35/EU; 2011/65/EU; 2012/19/EU
The above product is in conformity with the following standards or
other normative documents:
EN 61326-1 :
EN 61326-2-1:
EN 61326-2-2:
Electrical equipment for measurement, control and
laboratory use –– EMC requirements (2006)
Conducted and Radiated Emissions
EN 55011: 2009+A1: 2017 ClassA
Electrical Fast Transients
EN 61000-4-4: 2012
Current Harmonic
EN 61000-3-2: 2014
Surge Immunity
EN 61000-4-5: 2006
Voltage Fluctuation
EN 61000-3-3: 2013
Conducted Susceptibility
EN 61000-4-6: 2014
Electrostatic Discharge
EN 61000-4-2: 2008
Power Frequency Magnetic Field
EN 61000-4-8: 2010
Radiated Immunity
EN 61000-4-3: 2006 +AMD2: 2010
Voltage Dips/ Interrupts
EN 61000-4-11: 2004
Low Voltage Equipment Directive 2006/95/EC
Safety Requirements: EN 61010-1: 2010; EN 61010-2-030: 2010
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com