Instek Instek PEL-3021H Quickstart

DC Electronic Load
PEL-3000(H) Series
QUICK START GUIDE
GW INSTEK PART NO. 82EL-31110MD1
ISO-9001 CERTIFIED MANUFACTURER
99 Washington Street Melrose, MA 02176
Phone 781-665-1400
Visit us at www.TestEquipmentDepot.com
Toll Free 1-800-517-8431
This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will Corporation.
The information in this manual was correct at the time of printing. However, Good Will continues to improve its products and therefore reserves the right to change the specifications, equipment, and maintenance procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.
SAFETY INSTRUCTIONS
Warning
Warning: Identifies conditions or practices that could result in injury or loss of life.
Caution
Caution: Identifies conditions or practices that could result in damage to the instrument or to other properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal
Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased.
This section contains the basic safety symbols that may appear on the accompanying User Manual CD or on the instrument. For detailed safety instructions and precautions, please see the Safety Instructions chapter in the user manual CD.
Safety Symbols
These safety symbols may appear in the user manual or on the instrument.
Power Cord for the United Kingdom
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
When using the instrument in the United Kingdom, make sure the power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons.
WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code:
As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug/appliance, proceed as follows: The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black. The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red. If in doubt, consult the instructions provided with the equipment or contact the supplier. This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of
0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used. Any exposed wiring from a cable, plug or connection that is engaged in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any fuses and fuse assemblies. All hazardous wiring must be immediately destroyed and replaced in accordance to the above standard.
GETTING STARTED
Model
Voltage (DC)
Current
Power
PEL-3021(H)
0V~150V/0V-800V
35A/8.75A
175W
PEL-3041(H)
0V~150V/0V-800V
70A/17.5A
350W
PEL-3111(H)
0V~150V/0V-800V
210A/52.5A
1050W
PEL-3211(H) (Booster)
0V~150V/0V-800V
420A/105A
2100W
Performance
High slew rates of up to
16A/μS(PEL-3111),0.8A/μS(PEL­3111H) for a fast response speed
The Getting Started chapter introduces the instrument’s main features, appearance, and set up procedure.
Overview
The PEL-3000(H) Series is a family of high performance DC electronic loads positioned to test a wide range of different power sources. The DC electronic loads are fully programmable to simulate anything from basic static loads to complex dynamic loads. With the ability to operate independently or in parallel, the PEL-3000(H) Series is extremely robust and capable of molding to any test environment.
Model Line Up
Main Features
High capacity when used in parallel: 5250W, 1050A(262.5A), PEL-3111(H) x 5) 9450W, 1890A(472.5A), PEL-3111(H) + PEL-3211(H) x 4)
High resolution – 16 bit
Features
7 operating modes: CC, CV, CR,
CP, CC+CV, CR+CV, CP+CV
Independent and parallel
operation
Fully programmable with normal
and fast sequences
Soft start
Dynamic mode
OCP, OVP and other protection
features
Remote sense
Integrated meter
Rack-mountable
Load booster
Interface
USB, RS232 and GPIB
External voltage or resistance
control
Front panel trigger out BNC
Front panel current (voltage)
monitoring BNC
Analog external control
Package Contents and Accessories
Standard Accessories
Item
Part Number
User /Programming Manual CD
Quick Start Guide (this document)
Load input terminal Cover, M3 screw x1
PEL-011
Terminal fittings: 2 sets of bolts/nuts/springs/washers (type: M8), terminal cover x1 (for PEL­3000H series only), monitor out cover x 1(for PEL-3021H, PEL­3041H, PEL-3111H only)
PEL-012
Flexible terminal cover: 2x rubber sheeting, 4x Velcro fasteners.(for PEL-3211(H)only)
PEL-013 J1/J2 Protection plug x2 (It is installed on the device)
PEL-014 Front terminal washers (M6) x2
61SF-062104N1
Power Cord x1
Region Dependent
300mm Frame Link Cable (for linking units that are stacked). Note that this accessories is optional for the PEL-3021(H)/ 3041(H)
GTL-255
Optional Accessories
Item
Part Number
Rack mount bracket for booster PEL-3211(H) (EIA + JIS)
GRA-413
Rack mount frame for PEL­3021(H), PEL-3041(H), PEL­3111(H)/EIA
GRA-414-E
Rack mount frame for PEL­3021(H), PEL-3041(H), PEL­3111(H)/JIS
GRA-414-J
GPIB cable, 2.0m
GTL-248
USB cable. Type A - Type B
GTL-246
Dust filter
PEL-010
CR123A 3V lithium battery for clock.
3813-030D0501 Connect Cu Plate
PEL-005
Connect Cu Plate
PEL-006
Connect Cu Plate
PEL-005
Connect Cu Plate
PEL-005
Connect Cu Plate
PEL-005
Front Panel
I MON OUT TRIG OUT
1.5 - 150V
175W
0 - 35A
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/ Off
Main
Help
FUNC
Short
1 2 3
4
5
6
7
8
9
10
11
12
1314
V MON OUT
TRIG OUT
5 -800V
350W
0 -8.75A
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/ Off
Main
Help
FUNC
Short
I MON OUT
A/ B
1 2
3
4
5
6
7
8
9
10
11
12
1314
PEL-3021 and PEL-3041
PEL-3021H and PEL-3041H
PEL-3111
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/ Off
Main
Help
FUNC
Short
TRIG OUT
I MON OUT
1.5 - 150V
1050W
0 - 70A
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/ Off
Main
Help
FUNC
Short
TRIG OUT
I MON OUT
5 - 800V
1050W
0 – 52.5A
V MON OUT
A/B
LINK STBY
Description
1. Air inlet
2. LCD Display
3. Function keys
4. Power key
5. Main/Local key
6. FUNC/File key
7. Help/Utility key
8. Short key
9. Load On/Off
10. Scroll wheel
11. Number pad, Clear/
Lock and Enter keys
12. USB port, Preset and
Shift keys
13. I MON OUT and TRIG
OUT(for PEL-3000 series) I MON OUT, V MON OUT, TRIG OUT(for PEL-3000H series)
14. Input terminals
PEL-3111H
PEL-3211(H) Booster Pack
Rear Panel
47 - 63 Hz
90 VA MAX.
AC
100 - 120 VAC 200 - 240 VAC
FRAME CONT
J 1
J 2
SER. NO. LB
RS232C
GPIB
WARNING
TO AVOID ELECTRIC SHOCK THE POWER CORD
DO NOT REMOVE COVERS.
NO OPERATOR SERVICEABLE COMPONENTS INSIDE.
PROTECTIVE GROUNDING CONDUCTOR MUST BE
REFER SERVICING TO QUALIFIED PERSONNEL.
CONNECTED TO GROUND.
1
2
3
456
7
8
9
47 - 63 Hz
90 VA MAX.
AC
100 -120 VAC 200 -240 VAC
FRAME CONT
J 1
J 2
RS232C
GPIB
VR1 VR2 VR3 VR4
V/I MON OUT
1
1 2
3
9
8
7
6
5
4
10
11
PEL-3021 and PEL-3041
PEL-3021H and PEL-3041H
PEL-3111
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/ Off
Main
Help
FUNC
Short
TRIG OUT
I MON OUT
1.5 - 150V
1050W
0 - 70A
Description
1. Frame control ports, J1, J2
2. Remote sense inputs
3. Rear panel inputs
4. Exhaust fan
5. Power socket and switch
6. GPIB (optional)
7. USB device port
8. USB port
9. RS232C port
10. Variable Resistor
11. Monitor Out ports J3
PEL-3111H
PEL-3211 Booster Pack
PEL-3211H Booster Pack
Display Overview
1 2
3
4
5
6
ModeCVI Range
H 35A
V Range
L 15V
Function
Static
Configure
0.000
V
0.000A
0.00w
SlewRate 2500.00
CC B Value 0.000
CC A Value 0.000
LOADRS232
A Value
Fine
03/Sep/2012
mA/us
A
A
Description
1. Date and time
2. Main frame status panel
3. Operation status panel
4. Soft keys
5. Setting area
6. Measurement area
Use the following procedures when first using the PEL-3000(H) to power up the instrument, set the internal clock, restore the factory default settings and check the firmware version. Lastly, the Conventions section will introduce you to the basic operating conventions used throughout the user manual.
1. Insert the AC power cord into the power socket.
2. Turn the power switch on from the rear panel. (O )
First Time Use Instructions
Power Up
3. If the unit doesn’t turn on, press the ON/STBY key on the front panel.
The ON/STBY key will go from standby (red)
to ON (green).
4. The unit will show the splash screen and then load the settings from when the unit was last powered down.
Load Default Settings
When first using the PEL-3000(H), recall the factory default settings to ensure the unit is in a known state. See the user manual for a list of the default settings.
1. Press
Shift
+
File
FUNC
.
2. Select Media/Default [F1].
3. Select Factory Default [F2].
4. Press Factory Default [F2] again to confirm.
The date and time settings are used to time-stamp files when saving files.
1. Press
Shift
+
Utility
Help
> Time Set[F4] to set the
date and time.
Settings: Month, Day, Year, Hour, Minute
Setting the Date and Time
Updating the Firmware
The PEL-3000(H) allows the firmware to be updated by end-users. Before using the PEL-3000(H), please check the GW Instek website or ask your local distributor for the latest firmware. Before updating the firmware, please check the firmware version.
View Firmware Version
1. Press
Shift
+
Utility
Help
.
2. Select System/Info[F1].
3. The system information is listed in the display.
Model: PEL-3000(H) model number.
Serial Number: XXXXXXXX
Firmware Ver.: Firmware version number.
Website address.
Firmware update
1. Insert a USB drive into the USB port. Ensure the
USB drive has the firmware file located in the root directory.
2. Press
Shift
+
File
FUNC
.
3. Select USB with the Media [F1] soft-key.
4. Press the File Utility [F5] soft-key.
5. Select the *.UPG upgrade file and press Select[F1]
twice. Once to select the file and once to confirm.
6. Wait for the update to complete and reset the
power.
Warning
Do not turn the load generator off or remove the USB memory when the firmware is being read or upgraded.
Conventions
The following conventions are used throughout the user manual. Read the conventions below for a basic grasp of how to operate the PEL-3000(H) menu system using the front panel keys.
Soft-menu keys
The F1 to F5 function keys at the bottom of the display correspond directly to the soft-menu keys on top.
P0
P1
P4
P7
CAL.
P2
P5
P8
Lock
P3
P6
P9
Utility
Local
File
0
1
4
7
2
5
8
3
6
9
EnterClear
Shift
Preset
Load
On/
Off
Main
Help
FUNC
Short
F1 ~ F5
function keys
Soft-menu keys
ModeCVI Range
H 35A
V Range
L 15V
Function
Static
Configure
0.000
V
0.000A
0.00w
SlewRate 2500.00
CC B Value 0.000
CC A Value 0.000
LOADRS232
A Value
Fine
03/Sep/2012
mA/us
A
A
Select Sub Menu
Configure
Pressing this type of soft-menu key will enter a submenu.
Toggle Parameter or State
Mode
CC
Function/Item Parameter or State
This type of soft-menu icon has the function/item on the top of the label and the selected setting or mode on the bottom of the label.
Repeatedly press the associated function key (F1~F5) to cycle through each setting.
For some parameters, a popup window will also appear. Selection of the setting is the same. Repeatedly pressing the relevant function key (F1~F5) will cycle through each setting.
Parameter Input
The scroll wheel, Enter key and number pad can be used to edit parameter values.
1. Use the scroll wheel to move the cursor to the
desired parameter.
A scroll bar is shown when there are additional
parameters off-screen.
ModeCPI Range
H 35A
V Range
L 15V
Function Dynamic
Configure
0.000
V
0.000A
0.00w
Timer1 0.025
Level2 0.00
Level1 0.00
LOADRS232
Fine
03/Sep/2012
ms
W
W
Scroll bar
Cursor
2. Press the
Enter
key to select the parameter.
3. Then use umber pad* or scroll wheel** to edit the
parameter value.
ModeCCI Range
H 35A
V Range
L 15V
Function
Static
Configure
0.000
V
0.000A
0.00w
SlewRate 2500.00
CC B Value
CC A Value 0.000
LOADRS232
A Value
Fine
03/Sep/2012
mA/us
A
A
1.000
Parameter
4. Press the Enter key again to finish editing the
parameter value.
Clearing a Value
*When editing a parameter with the number pad, pressing the
Clear
key will restore the parameter
to the previous value.
Coarse/Fine Adjustment
**When a parameter is highlighted (step 3 above) pressing the scroll wheel will toggle the scroll wheel resolution between fine and coarse.
ModeCCI Range
H 35A
V Range
L 15V
Function
Static
Configure
0.000
V
0.000A
0.00w
SlewRate 2500.00
CC B Value
CC A Value 0.000
LOADRS232
A Value
Fine
03/09/12
mA/uS
A
A
1.000
+
Coarse/Fine adjustment
Higlighted parameter
Note: There is a second method of fine adjustment that allows you to edit parameters one digit value at a time using the scroll wheel. This is called Cursor mode. Please see the user manual for more information.
Entering Alphanumeric Characters
When renaming files, creating memos or notes, you will be required to enter alphanumeric characters when the character entry screen appears.
Only alphanumeric characters as well as
space [ ], underscore [_] and minus [-] characters are allowed.
1. Use the scroll wheel to move the cursor to the
desired character.
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9 0 _ 1
Rename:
Filename
Cursor
2. Press the
Enter
key or Enter Character[F1] to
select a character.
3. To delete a character, press Back Space[F2].
4. To save the file name or memo, press Save[F3].
SPECIFICATIONS
Model
PEL-3021(H)
PEL-3041(H)
PEL-3111(H)
Voltage
0V-150V(0V/800V)
Current
35A(8.75A)
70A(17.5A)
210A(52.5A)
Min. Operating Voltage
1.5V at 35A
(5V at 8.75A)
1.5V at 70A
(5V at 17.5A)
1.5V at 210A
(5V at 52.5A)
Power
175W
350W
1050W
Model
PEL-3021(H)
PEL-3041(H)
PEL-3111(H)
H Range
0A-35A (0-8.75A)
0A-70A (0-17.5A)
0A-210A (0-52.5A)
M Range
0A-3.5A (0-875mA)
0A-7A (0-1.75A)
0A-21A (0-5.25A)
L Range
0A-0.35A (0-87.5mA)
0A-0.7A (0-175mA)
0A-2.1A (0-525mA)
Model
PEL-3021(H)
PEL-3041(H)
PEL-3111(H)
H Range
23.3336S-400μS
(42.857m-
2.5k)/(H)
1.75S-30μS
(571mΩ-33.3kΩ)
46.6672S-800μS
(21.428m
-1.25k)/(H)
3.5S-60μS
(285mΩ-16.6kΩ)
140.0016S~2.4mS
(7.1427m-
416.6667)/(H)
10.5S-200μS
(95.2mΩ-5kΩ)
M Range
2.33336S-40μS
(428.566m
-25k)/(H)
175mS-3μS (5.71mΩ-333MΩ)
4.6667S-80μS
(214.28m
-12.5k)/(H)
35mS-6μS (2.85mΩ-166kΩ)
14.0001S-242.4μS
(71.427m
-4.16667k)/(H)
1.05S-20μS
(952mΩ-50kΩ)
The following are the basic specifications for the PEL­3000(H) series. For detailed specifications, please see the user manual
Rating
CC Mode Operating Range
CR Mode Operating Range
L Range
0.233336S-4μS
(4.28566
-250k) /(H)
17.5mS-0.3μS
(57.1Ω-3.33MΩ)
0.46667S-8μS
(2.1428
-125k) /(H)
35mS-0.6μS (28.5Ω-1.66kΩ)
1.40001S-24.24μS
(714.27m
-41.6667k) /(H)
105mS-2μS (9.52Ω-500kΩ)
CV Mode Operating Range
Model
PEL-3021(H)
PEL-3041(H)
PEL-3111(H)
H Range
1.5V-150V
(5V-800V)
1.5V-150V
(5V-800V)
1.5V-150V
(5V-800V)
M Range
1.5V-15V
(5V-80V)
1.5V-15V
(5V-80V)
1.5V-15V
(5V-80V)
Model
PEL-3021(H)
PEL-3041(H)
PEL-3111(H)
H Range
17.5W ~175W
35W~350W
105W ~1050W
M Range
1.75W ~17.5W
3.5W~35W
10.5W ~105W
L Range
0.175W~1.75W
0.35W~3.5W
1.05W ~10.5W
Model
PEL-3021(H)
PEL-3041(H)
PEL-3111(H)
H Range
2.5mA/μs
-2.5A/μs(H)
0.1400mA/μs-
140.0mA/μs
5mA/μs
-5A/μs(H)
0.280mA/μs-
280.0mA/μs
16.02mA/μs
-16.002A/μs
(H)0.840mA/μs-
840.0mA/μs
M Range
250uA/μs­250mA/μs(H)
0.01400mA/μs-
14.000mA/μs
500uA/μs­500mA/μs(H)
0.0280mA/μs-
28.00mA/μs
1.602mA/μs
-1.6002A/μs(H)
0.0840mA/μs-
84.00mA/μs
L Range
25uA/μs
-25mA/μs(H)
1.400μA/μs-
1400.0μA/μs
50uA/μs
-50mA/μs(H)
2.80μA/μs-
2800μA/μs
160.2uA/μs
-160.02mA/μs
(H)0.00840mA/ μs-8.400mA/μs
CP Mode Operating Range
Slew Rate CC Mode Setting Range
Slew Rate CR Mode Setting Range
Model
PEL-3021(H)
PEL-3041(H)
PEL-3111(H)
H Range
250uA/μs
-250mA/μs(H)
0.01400mA/μs
-14.000mA/μs
500uA/μs
-500mA/μs(H)
0.0280mA/μs-
28.00mA/μs
1.602mA/μs
-1.6002A/μs(H)
0.0840mA/μs-
84.00mA/μs
M Range
25uA/μs
-25mA/μs(H)
0.001400mA/μ
s-1.4000mA/μs
50uA/μs
-50mA/μs(H)
0.00280mA/μs-
2.800mA/μs
160.2uA/μs
~160.02mA/μs (H)0.0840mA/μ s-8.400mA/μs
L Range
2.5uA/μs
-2.5mA/μs(H)
0.1400μA/μs-
140.00μA/μs
5uA/μs
-5mA/μs(H)
0.280μA/μs-
280.0μA/μs
16.02uA/μs
-16.002mA/μs
(H)0.00840mA/ μs-0.8400mA/μs
EC Declaration of Conformity (PEL-3000 series)
We
GOOD WILL INSTRUMENT CO., LTD.
No.7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan
PEL-3021, PEL-3041, PEL-3111
satisfies all the technical relations application to the product within the scope of council: Directive: 2014/30/EU; 2014/35/EU; 2011/65/EU; 2012/19/EU The above product is in conformity with the following standards or other normative documents:
EMC
EN 61326-1 : EN 61326-2-1: EN 61326-2-2:
Electrical equipment for measurement, control and laboratory use –– EMC requirements (2006)
Conducted and Radiated Emissions EN 55011: 2009+A1: 2010
Electrical Fast Transients EN 61000-4-4: 2012
Current Harmonic EN 61000-3-2: 2014
Surge Immunity EN 61000-4-5: 2006
Voltage Fluctuation EN 61000-3-3: 2013
Conducted Susceptibility EN 61000-4-6: 2014
Electrostatic Discharge EN 61000-4-2: 2009
Power Frequency Magnetic Field EN 61000-4-8: 2010
Radiated Immunity EN 61000-4-3: 2006 +A1: 2008+A2: 2010
Voltage Dips/ Interrupts EN 61000-4-11: 2004
Safety
Low Voltage Equipment Directive 2006/95/EC
Safety Requirements: EN 61010-1: 2010; EN 61010-2-030: 2010
EC Declaration of Conformity (PEL-3000H series)
We
GOOD WILL INSTRUMENT CO., LTD.
No.7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan
PEL-3021H, PEL-3041H, PEL-3111H
satisfies all the technical relations application to the product within the scope of council: Directive: 2014/30/EU; 2014/35/EU; 2011/65/EU; 2012/19/EU The above product is in conformity with the following standards or other normative documents:
EMC
EN 61326-1 : EN 61326-2-1: EN 61326-2-2:
Electrical equipment for measurement, control and laboratory use –– EMC requirements (2006)
Conducted and Radiated Emissions EN 55011: 2009+A1: 2017 ClassA
Electrical Fast Transients EN 61000-4-4: 2012
Current Harmonic EN 61000-3-2: 2014
Surge Immunity EN 61000-4-5: 2006
Voltage Fluctuation EN 61000-3-3: 2013
Conducted Susceptibility EN 61000-4-6: 2014
Electrostatic Discharge EN 61000-4-2: 2008
Power Frequency Magnetic Field EN 61000-4-8: 2010
Radiated Immunity EN 61000-4-3: 2006 +AMD2: 2010
Voltage Dips/ Interrupts EN 61000-4-11: 2004
Safety
Low Voltage Equipment Directive 2006/95/EC
Safety Requirements: EN 61010-1: 2010; EN 61010-2-030: 2010
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com
Loading...