AEL-5000 Series LAN Instruction ........................... 255
3
AEL-5000 User Manual
WARNING
Warning: Identifies conditions or practices that
could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that
could result in damage to the instrument or to
other properties.
DANGER High Voltage
Attention Refer to the Manual
Earth (ground) Terminal
Frame or Chassis Terminal
Do not dispose electronic equipment as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased.
SAFETY INSTRUCTIONS
This chapter contains important safety instructions that you must
follow during operation and storage. Read the following before any
operation to insure your safety and to keep the instrument in the
best possible condition.
Safety Symbols
These safety symbols may appear in this manual or on the
instrument.
4
SAFETY INSTRUCTIONS
General
Guideline
CAUTION
Do not place any heavy object on the
instrument. Note: Only 2 units can be stacked
vertically.
Avoid severe impact or rough handling that
leads to damaging the instrument.
Do not discharge static electricity to the
instrument.
Use only crimped wires, not bare wires, for the
terminals.
Do not block the cooling fan opening.
Do not disassemble the instrument unless you
are qualified.
The equipment is not for measurements
performed for CAT II, III and IV.
(Measurement categories) EN 61010-1:2010 specifies the
measurement categories and their requirements as follows.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in
the building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
0 is for measurements performed on circuits not directly
connected to Mains.
Do NOT position the equipment so that it is difficult to disconnect
the appliance inlet or the power plug.
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be
impaired.
Safety Guidelines
5
AEL-5000 User Manual
Power Supply
WARNING
AC Input voltage range: 100Vac~240Vac ± 10%
Frequency: 47-63Hz
Power for every model
To avoid electrical shock connect the protective
grounding conductor of the AC power cord to
an earth ground.
To avoid electric shock, the power cord
protective grounding conductor must be
connected to ground. No operator serviceable
components inside. Do not remove covers.
Refer servicing to qualified personnel.
6
SAFETY INSTRUCTIONS
Cleaning
Disconnect the power cord before cleaning.
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid.
Do not use chemicals containing harsh material
such as benzene, toluene, xylene, and acetone.
Operation
Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
Temperature: 0°C to 40°C
Humidity: 0 to 85% RH
Altitude: <2000m
Overvoltage category II
(Pollution Degree) EN 61010-1:2010 specifies the pollution degrees
and their requirements as follows. The instrument falls under
degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric
strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity
caused by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to
condensation which is expected. In such conditions,
equipment is normally protected against exposure to direct
sunlight, precipitation, and full wind pressure, but neither
temperature nor humidity is controlled.
Do not dispose this instrument as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased. Please make sure
discarded electrical waste is properly recycled to
reduce environmental impact.
7
AEL-5000 User Manual
AEL-5000 LOAD
Operating mode
AEL-5000 Ser ies Op erating Mo des
daoLCDdaoLCA
Sine Wave
Voltage Source
Constant Current
Mode
Linear Constant
Current Mode
Constant Resistance
Mode
Linear Constant
Current Mode
Constant Resistance
Mode
Constant Power
Mode
Constant Voltage
Mode
Rectifier Load
Non-linear Mode
Rectifier Load
Non-linear Mode
Constant Current
Mode
Linear Constant
Current Mode
Constant Resistance
Mode
Constant Power
Mode
Constant Voltage
Mode
Rectifier Load
Non-linear Mode
+
Constant Resistance
Rectifier Load
Non-linear Mode
+
Constant Resistance
PWM, Step, SquareWave
Voltage Source
GETTING STARTED
AEL-5000 Series is suitable for the step, square and sine wave of the
AC Power device test. Especially for the uninterruptible power
supply UPS, Inverter, fuses, circuit breakers, power regulator AVR,
Battery, AC/ DC power supply/ components ... and so on,
absolutely is the best test solution in the market.
8
GETTING STARTED
AEL-5000 test
mode
Fuse / Br eaker Trip /
Non -trip Time Test
AC Power Sour ce Sh ort
Circ uit / OPP / OCP Test
DC P ower Sourc e Sh ort
Cir cuit / OPP / OC P Test
AEL-5000 Load Variou s Test Mo des
UPS
Eff icie ncy Test
PV Inverter Eff iciency Test
UPS Trans fer T ime Test
UPS Back-up Time Test
daoLCDdaoLCA
Battery Discharge Time Test
Fuse / Br eaker Trip /
Non -trip Time Test
Fuse / Br eaker Trip /
Non -trip Time Test
AC Power Sour ce Sh ort
Circ uit / OPP / OCP Test
Turbo Mode
(Cu rrent / Pow er 2 Times)
Fuse / Br eaker Trip /
Non -trip Time Test
Bat tery D ischa rge
Capa city Test
AC Pow er Sou rce S hort
Circ uit / OPP / OCP Test
Turbo Mode
(Cu rrent / Pow er 2 Time s)
The most complete measurement function
AEL-5000 Series AC/ DC electronic load has built-in 16-bit
precision measurement circuit, providing accurate measurement
values, measuring items include voltage rms (Vrms), current rms
(Arms), watts (Watt), volt ampere (VA), crest factor (CF), power
factor (PF), voltage total harmonic distortion (VTHD), voltage
harmonics (VH), current total harmonic distortion (ITHD), current
Harmonics (IH), peak current (Ipeak), maximum ampere (Amax),
minimum ampere (Amin), maximum voltage (Vmax), and
minimum voltage (Vmin).
In addition to these measurement functions, it also provides time
measurement, such as UPS back up time, fuses and circuit breakers’
trip or blow time and Off-line UPS transfer time.
Note*1:ms= milli - siemens = 1/kΩ
Note*2:The operating temperature range is 0 ~ 40° C,accuracy of
this specification is 25 ° C ± 5° C
9
AEL-5000 User Manual
AEL-5000 Series Introduction................................... 11
Model Line Up ................................................................................ 11
Main Features .................................................................................. 12
Protection features .......................................................................... 14
display the Voltage (Vrms, Vpeak, Vmax.,
Vmin), Current (Irms, I Peak, Imax. Imin.)
Watt, Voltampere (VA), Frequency, Crest
Factor, Power Factor, Total Harmonic
Distortion of Voltage (VTHD), Voltage
Harmonic (VH), Total Harmonic Distortion of
Current (ITHD), Current Harmonic (IH)
Remote Control via a choice of Computer
interfaces.
Support on-load boot; at first set Load ON to
support on-load boot, inverter or
uninterruptible power supply is turned on
directly with the set load current, used to
verify whether the starter is stable when the
Inverter is connected.
Supports the loading and unloading angle
control; the loading and unloading angle
control, the full range of 0-359 degrees can be
set to verify whether the Inverter output
voltage transient response is stable when the
actual electrical plugging and unplugging, and
whether Overshoot/Undershoot is within the
Main Features
12
GETTING STARTED
allowable range.
Support positive half-cycle or negative half-
cycle loading; used to verify whether the
inverter output voltage remains stable when
the actual appliance has only positive halfcycle or negative half-cycle load current.
Supports SCR/TRIAC current phase
modulation waveforms, 90 degree Trailing
edge and Leading Edge.
Supports the Inrush Current of the power
supply at startup and the Surge Current test
when the load is suddenly plugged in (Hot
Plug-in).
Features
AC / DC load with CC, Linear CC, CR, CV, CP
and Rectifier Load mode
Frequency Range : DC, 40~440Hz
Crest factor adjustable range : 1.4~5.0
Power factor (PF) adjustable range: 0~1 lead or
(~1~0)lag
Built-in test modes include UPS Efficiency, PV
Inverter Efficiency, UPS Back-up time, Battery
Discharge time, UPS transfer time, Fuse/
Breaker Trip / Non-Trip, short circuit
simulation, OCP, OPP, etc.
Turbo mode, which can withstand up to twice
the current (225A) and power (45KW)
electronic load in a short time, the most
suitable for Fuse / Breaker and AC power
short circuit, OCP, OPP test.
Up to three parallel up to 22500W and three-
phase △ or Y load synchronization control.
Maximum power of single-phase can up to
180KW, 3-phase total power up to 540KW 3phase △ or Y connection parallel connection
can be controlled by external voltage for CC,
Linear CC, CR, CP, CV mode (Option)
Measure the fuse and circuit breaker trip or
13
AEL-5000 User Manual
blow time
Measure the UPS OFF- line transfer time
(Transfer time)
Perform short circuit simulation(can set the
short circuit time), OCP, OPP test
Over voltage warning, over current, over
power, over temperature protection.
150 set Store/Recall memory.
Interface
Optional interface: GPIB, RS232, USB, LAN.
Overvoltage
protection
The Electronic Load input will turn OFF if the
overvoltage circuit is tripped. The message OVP
will be displayed on the LCD. When the OVP
fault has been removed the load can be set to sink
power again. While the unit will attempt to
protect itself given an OVP state it is strongly
advised to guard against any potential OVP fault
state by using external protection and the
correctly rated electronic load.
The Overvoltage protection circuit is set at a
predetermined voltage and cannot be adjusted.
The OVP level is 105% of the AEL-5000 Series
nominal voltage rating.
Caution
Never apply an AC voltage to the input of the
AEL-5000 Series Load. Do not apply a DC voltage
that is higher than AEL-5000 Series Load rating. If
this advice is ignored it is likely that damage will
be caused to the electronic load module. This
damage will not be covered by the warranty.
Over current
protection (OCP)
The OCP protection will engage if the current
being taken by the load reaches 105% of the load
module’s maximum current. The message OCP
Protection features
The protection features of the AEL-5000 series electronic load
modules are as follows:
14
GETTING STARTED
will be displayed on the front panel and the unit
will switch to its LOAD OFF state. Once the
source of the over current has been removed the
load can be switched on again.
Over power
protection (OPP)
The AEL-5000 Series Electronic Load monitors the
power dissipation level. The input to the load is
automatically switched to LOAD OFF if the power
dissipation is greater than 105% of the rated
power input. If an over power condition occurs
the display will show OPP
Over temperature
protection
The load internal temperature at the heat sink is
monitored. If the temperature reaches
approximately 100°C the OTP message will be
displayed and the unit will automatically switch
to the LOAD OFF state. If an OTP error occurs
please check the ambient temperature is between
0 to 40°C. Also ensure that the front and rear air
vents of the mainframe are not obstructed. The air
flow is taken from the front of the mainframe and
exhausted from the rear. Therefore a suitable gap
needs to be left at the rear of the mainframe. A
minimum of 15cm is recommended. After a
suitable cooling period the load can be switched.
USB interface + USB driver(The
driver can be downloaded from
GW instek website)
PEL-025
1
LAN interface + LAN driver (The
driver can be downloaded from
GW instek website)
PEL-024
1
GPIB cable
GTL-250 GPIB Cable,0.6m
1
GPIB cable
GTL-248 GPIB Cable,2m
1
USB cable
GTL-246 USB Cable,1.2m
1
AEL-5000, AEL-5006, AEL-5008,
AEL-5012 and AEL-5015 handle
PEL-028
1
AEL-5002, AEL-5003 and AEL-5004
handle
PEL-029
1
AEL-5000, AEL-5000 GPIB and RS232 interface
PEL-030
1
17
AEL-5000 User Manual
CC Mode
With the operating mode of Constant Current, the
AEL-5000 Series electronic load will sink a current
in accordance with the programmed value
regardless of the input voltage
Current
Setting
Linear C.C. Mode
During Linear C.C. mode, the load current input
into AEL-5000 Series High Power Electronic Load
depends on the current setting regardless of the
input voltage, e.g., the current setting remains
unchanged. Please refer to Fig.1-8. The load input
current signal will follow input voltage signal that
is useful for step wave-form and square waveform device.
Current
Setting
CR Mode
At Constant Resistance mode, the AEL-5000 Series
Electronic Load will sink a current linearly
proportional to the load input voltage in
accordance with the programmed resistance
setting
Operating Mode Description
AC load mode
18
GETTING STARTED
Resistance
Setting
CP Mode
At Constant Power mode, the AEL-5000 Series
Electronic Load will attempt to sink load
power (load voltage * load current) in
accordance with the programmed power.
Power Setting
CV Mode
At Constant Voltage mode, the AEL-5000 Series
Electronic Load will attempt to sink enough
current until the load input voltage reaches the
programmed value.
Voltage Setting
19
DC load mode
CC Mode
With the operating mode of Constant Current, the
AEL-5000 Series electronic load will sink a current
in accordance with the programmed value
regardless of the input voltage
Current
Setting
CR Mode
At Constant Resistance mode, the AEL-5000 Series
Electronic Load will sink a current linearly
proportional to the load input voltage in
accordance with the programmed resistance
setting
Resistance
Setting
CP Mode
At Constant Power mode, the AEL-5000 Series
Electronic Load will attempt to sink load
power (load voltage * load current) in
accordance with the programmed power.
AEL-5000 User Manual
20
GETTING STARTED
Power Setting
CV Mode
At Constant Voltage mode, the AEL-5000 Series
Electronic Load will attempt to sink enough
current until the load input voltage reaches the
programmed value.
Voltage Setting
21
AEL-5000 User Manual
AEL-5002-350-18.75
350V
10V
18.75A6.25A
1875W
Power Curve
Voltage
Current
100V
50V
12.5A18.5A
20V
30V
5.35A
AEL-5003-350-28
350V
10V
28A8A
2800W
Power Curv
Voltage
Current
100V
50V
18.75A27.75A
20V
30V
9.375A
AEL-5004-350-37.5
350V
10V
37.5A
12.5A
3750W
Power Curve
Voltage
Current
100V
50V
25A37A
20V
30V
10.7A
AEL-5002-425-18.75
425V
10V
18.75A6.25A
1875W
Power Curve
Voltage
Current
100V
50V
12.5A18.5A
20V
30V
4.4A
Operating Area
AEL-5000 Series AC/DC electronic load can be used to work with
GPIB, RS232, USB or LAN interface and panel manual operation
can be made available.
The electronic load operating environment temperature is 0 ° C ~
40 ° C, full power operation for a period of time may produce OTP.
22
GETTING STARTED
AEL-5003-425-28
425V
10V
28A
6.58A
2800W
Power Curv
Voltage
Current
100V
50V
18.75A27.75A
20V
30V
9.375A
AEL-5004-425-37.5
425V
10V
37.5A
12.5A
3750W
Power Curve
Voltage
Current
100V
50V
25A37A
20V
30V
8.8A
AEL-5006-350-56
350V
10V
56A
18.75A
5600W
Power Curve
Voltage
Current
100V
50V
37.5A55A
20V
30V
16A
AEL-5008-350-75
350V
10V
75A
25A
7500W
Power Curve
Voltage
Current
100V
50V
50A74A
20V
30V
21.4A
AEL-5012-350-112.5
350V
10V
112.5A32.1A
11250W
Power Curve
Voltage
Current
100V
50V
75A111A
20V
30V
37.5A
23
AEL-5000 User Manual
AEL-5015-350-112.5
350V
112.5A
15000W
Power Curve
Voltage
Current
133.3V
50V
75A111A
20V
30V
42.8A
AEL-5019-350-112.5
350V
112.5A
18750W
Power Curve
Voltage
Current
166.6V
50V
75A
111A
20V
30V
53.5A
AEL-5023-350-112.5
350V
112.5A
22500W
Power Curve
Voltage
Current
200V
50V
75A111A
20V
30V
64.2A
AEL-5006-425-56
425V
10V
56A
18.75A
5600W
Power Curve
Voltage
Current
100V
50V
37.5A55A
20V
30V
13.1A
AEL-5008-425-75
425V
10V
75A
25A
7500W
Power Curve
Voltage
Current
100V
50V
50A74A
20V
30V
17.6A
24
GETTING STARTED
AEL-5012-425-112.5
425V
10V
112.5A26.4A
11250W
Power Curve
Voltage
Current
100V
50V
75A111A
20V
30V
37.5A
AEL-5015-425-112.5
425V
112.5A
15000W
Power Curve
Voltage
Current
133.3V
50V
75A111A
20V
30V
35.2A
AEL-5019-425-112.5
425V
112.5A
18750W
Power Curve
Voltage
Current
166.6V
50V
75A
111A
20V
30V
44.1A
AEL-5023-425-112.5
425V
112.5A
22500W
Power Curve
Voltage
Current
200V
50V
75A111A
20V
30V
52.9A
AEL-5003-480-18.75
480V
18.75A5.8A
2800W
Power Curve
Voltage
Current
149V
50V
12.5A
20V
25
AEL-5000 User Manual
AEL-5004-480-28
480V
28A
3750W
Power Curve
Voltage
Current
133V
50V
18.6A
20V
7.8A
26
GETTING STARTED
1
LCD Multifunction
display
Four meters can display the voltage value at the
same time Voltage(Vrms, Vpeak, Vmax, Vmin),
Current (Irms, Ipeak, Imax, Imin.) , Watt,
Voltampere (VA), Frequency, Crest Factor,
Power Factor, Total Harmonic Distortion of
Voltage(VTHD), Voltage Harmonic (VH), Total
Harmonic Distortion of Current (ITHD),
Current Harmonic (IH)
2
Meter Switch
button
V/AW keys can set the display
Rms/Peak/Max/Min, Meter key can select
PF/CF/FREQ, switchable display
WATT/VA/VAR keys, THD keys choose to
display THD.
3
Operate
function keys
Mode, Preset ON/OFF, Load ON/OFF, Sense
ON/OFF, Level A/B, Config, Limit, Recall,
Store, SET, Local, System operate keys.
4
Waveform
library keys
These keys can be quickly set CF /2/2.5/3/3.5,
PF0.6/0.7/0.8/0.9/1.0, FREQ
Auto/50Hz/60Hz/400Hz
Appearance
Front Panel
27
AEL-5000 User Manual
5
Test function
keys
These keys can select Short/OPP/OCP/NonL/NL-CR/Fuse/Batt(Battery
Discharge)Trans(UPS transfer time) test
functions.
6
Number keypad
7
Knob setting
8