Instanta DB500, DB1000 Installation And User Instructions Manual

SureFlow Touch DB500 & DB1000
Auto-Fill Catering Water Boilers with Push Button Dispense
Installation And User Instructions
INSTANTA LIMITED Canning Road, Southport, Merseyside, PR9 7SN Tel: (01704) 501114 Fax: (01704) 501115 IB90 - ISS: 01
The Professional’s Choice
CONTENTS
CONTENTS, INTRODUCTION & SAFETY INFORMATION 2
ENVIRONMENTAL INFORMATION & DELIVERY CHECK-LIST 3
TECHNICAL SPECIFICATION 3
INSTALLATION 3
OPERATION 4
OPTIONAL TIMED DISPENSE (with Top-up facility) 5
REGULAR DAILY USE 5
OPTIONAL FILTER MONITOR 5
PREVENTATIVE MAINTENANCE & CLEANING 6
MAINTENANCE, SPARES & SERVICE INFORMATION 6
SERVICE WARNINGS & FAULT DIAGNOSTICS 7
GUARANTEE 8
Introduction
Dear Customer,
Thank you for purchasing this Instanta product.
Your new water boiler is designed to give you years of trouble-free service provided that the instructions contained in this manual are followed.
All new series Instanta products are energy
ecient, simple to operate and easy to service.
Find out more about Instanta products at
www.instanta.com
Safety Information
Please read the following carefully before starting work on this equipment.
A competent person should install this appliance in accordance with the installation instructions for this appliance and all relevant local and national standards including:
Health & Safety at Work Act
IEE Regulations
Local & national Building Regulations
BS Codes of practice
Water Supply Regulations
VERY HOT WATER – Your new SureFlow Touch dispense boiler is designed to provide a constant source of near boiling water, which can be dispensed for the preparation of hot drinks.
The SureFlow Touch appliances are ideal for self-service however, they are not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance.
Care should be taken to avoid potential injury from burns and scalding whilst operating this appliance. The LCD display on the front of the appliance shows the message “CAUTION HOT WATER” reminding users to exercise care when dispensing drinks.
In-line with Health & Safety requirements, we recommend a risk assessment be carried out after the boiler has been installed.
Always disconnect the unit from the power supply before servicing.
The appliance must be earthed.
Keep these instructions in a safe place near
the unit for future reference.
2
Environmental (Information On Disposal For Users Of Waste Electrical & Electronic Equipment)
The “crossed out wheelie bin” symbol on this product means that discarded electrical and electronic products should not be mixed with general waste. Disposing of the product correctly will help to save valuable resources
and prevent any potential negative eects
on human health and the environment which could otherwise arise from inappropriate waste handling. For proper treatment, recovery and recycling of end-of-life products, please contact your dealer or supplier for further information, or local authority for details of your nearest designated collection point.
Delivery Checklist
Before starting installation, check that you have the following parts;
Catering Water Boiler
Drip-tray
Drip-tray drain tting
(optional - for connecting front drip-tray to a permanent waste/drain)
Tapered rubber bung (optional - for blanking o front outlet if rear-overow outlet is preferred)
White water inlet hose (3/4”BSP connection)
User instructions
Technical Specification
Installation
The boiler must be installed on a horizontal
work surface with sucient strength to support
its weight.
Locate in an area where there is adequate space to use the boiler safely (e.g. free from risk of congestion and tripping hazards).
Do not block ventilation holes in boiler case.
Connection to Mains Water Supply:
Connect the WRAS approved water lling hose
supplied (¾” BSP) to the inlet connection point on the underside of the boiler and the other end to the mains water supply, via an accessible isolating tap with a ¾”BSP thread.
IMPORTANT: If micro-bore pipe is used instead of the inlet hose supplied, the size must be
minimum OD ⅜”(10mm).
The water supply must have a pressure not exceeding 7bar (96psi), and no lower than 2bar (28psi) NOTE: If your water pressure exceeds
7bar, t a suitable pressure reduction valve.
We regret that Instanta cannot be held responsible for any machine malfunctions if the water pressure exceeds that stated. If in doubt, consult your water supply company.
Electrical Connection:
The boiler must be Earthed.
Your machine is supplied with a standard 13amp bonded plug with a 13amp fuse.
3
Model DB500 DB1000
Width 240mm 240mm
Depth 522mm 522mm
Height 445mm 545mm
Power Rating 3.0kW 3.0kW
Weight (Empty) 10.9kg 12.3kg
Weight (Full) 19.8kg 26.5kg
Water Inlet Pressure: 2 to 7 Bar 2 to 7 Bar
Loading...